BODY ELECTRICAL — AIR CONDITIONING BE-71

JMODE POSITION AND DAMPER OPERATION

" Front Air Conditioning (Models with the multi-zone automatic climate control) A
Center Defroster
Side Defroster Side Defroster

Fresh
Air Recirc. Air
Front Foot Well
Register Duct

Blower Motor
Evaporator
Heater PTC Heater
Radiator Unit Assembly

Side Register Rear Foot Well Rear Center Rear Foot Well Side
Register Duct Register Register Duct Register
Front Center
Register
080BE39S

" Function of Main Damper A


Control Damper BE
Operation Position Operation
Damper Position
Air Inlet FRESH A Brings in fresh air.
Control
Damper RECIRC B Recirculates internal air.
Air Mix Varies the mixture ratio of the cold air and the hot
MAX COLD to MAX HOT
Control K-L-M air in order to regulate the temperature
Temp. Setting
Damper continuously from HOT to COLD.
Cool air blows out from the front center register
Cool Air
MAX COLD to MAX HOT and side registers, in order to adjust the
Bypass H-I-J
Temp. Setting temperature around the heads of the occupants
Damper
during cooling or warming.
Defrosts the windshield through the center
DEF C
187BE28 defroster, and side defroster.
Defrosts the windshield through the center
defroster, side defroster, while air is also blown
FOOT / DEF D out from the front and rear footwell register
187BE27 ducts. In addition, air blows out slightly from
front and rear center registers and side register.
Mode Air blows out of the front and rear foot well
Control register duct, front and rear center register, and
Damper FOOT E side register. In addition, air blows out slightly
187BE26 from the center defroster, side defroster and side
register.
Air blows out of the front and rear center
BI-LEVEL F registers, side register, and front and rear
187BE25 footwell register ducts.
Air blows out of the front and rear center
FACE G
187BE24 registers, and side register.

NM
0810E
BE-72 BODY ELECTRICAL — AIR CONDITIONING

" Front Air Conditioning Unit (Models with left / right independent temperature control) A

Center Defroster

Side Defroster Side Defroster

Fresh
Air Recirc. Air
Front Foot Well
Register Duct

Blower Motor
Evaporator

Heater
Radiator Unit PTC Heater
Assembly
Side Register Rear Foot Well Rear Center Rear Foot Well Side
Register Duct Register Register Duct Register
Front Center
Register 081BE15S

" Function of Main Damper A

Control Damper
Operation Position Operation
Damper Position
Air Inlet FRESH A Brings in fresh air.
Control
Damper RECIRC B Recirculates internal air.
Air Mix Varies the mixture ratio of the cold air and the hot
MAX COLD to MAX HOT
Control K-L-M air in order to regulate the temperature
Temp. Setting
Damper continuously from HOT to COLD.
Cool air blows out from the front center register
Cool Air
MAX COLD to MAX HOT and side registers, in order to adjust the
Bypass H-I-J
Temp. Setting temperature around the heads of the occupants
Damper
during cooling or warming.
Defrosts the windshield through the center
DEF C
187BE28 defroster, and side defroster.
Defrosts the windshield through the center
defroster, side defroster, while air is also blown
FOOT / DEF D out from the front and rear footwell register
187BE27 ducts. In addition, air blows out slightly from
front and rear center registers and side register.
Mode Air blows out of the front and rear foot well
Control register duct, front and rear center register, and
Damper FOOT E side register. In addition, air blows out slightly
187BE26
from the center defroster, side defroster and side
register.
Air blows out of the front and rear center
BI-LEVEL F registers, side register, and front and rear
187BE25
footwell register ducts.
Air blows out of the front and rear center
FACE G
187BE24 registers, and side register.

NM
0810E
BODY ELECTRICAL — AIR CONDITIONING BE-73

" Rear Air Conditioning A

Heater
Radiator Unit Rear Footwell
Register
Rear Roof Side Register

Blower Motor

080BE50S

" Function of Main Damper A BE


Control Damper Operation Position Damper Position Operation
Air blows out of the rear roof
FACE A
187BE24 side register.
Air blows out of the rear roof
Mode Control BI-LEVEL B side register and the rear
Door 187BE25
footwell register.
Air blows out of the rear
FOOT C
187BE26 footwell register.
Varies the mixture ratio of the
cold air and the hot air in order
Air Mix Control MAX COLD to MAX HOT
D-E to regulate the temperature
Damper Temp. Setting
continuously from HOT to
COLD.

NM
0810E