Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

Analysis Report 17.00808.

02
Date 07-03-2017
Page 1/18

Maxter Glove Manufacturing Sdn Bhd


Mr. Pei Shan Tay
Lot 6070 Jalan Haji Abudl Manan 6th Mile
Off Jalan Meru
41050 KLANG - SELANGOR
Maleisië
Your notice of Your reference Date
08-02-2017 07-03-2017

Analysis Report 17.00808.02


Required tests :
EN 374-2 (2014) Determination of resistance of water leak and air leak
EN 388-6.3 (2016) Determination of tearing resistance - gloves
EN 388-6.1 (2016) Determination of the abrasion resistance on Martindale with
emery paper
EN 388-6.4 (2016) Determination of the puncture resistance
EN 388-6.2 (2016) Determination of the blade cut resistance
EN 420 6.1 (2003) + A1 (2009) Determination of the dimensions of gloves
ISO 3071 (2005) Determination of the pH of an aqueous extract
EN 16523-1 (2015) Permeation of liquid chemicals through a protective clothing
material
EN 374-4 (2013) Determination of resistance to degradation by chemicals –
perforation test
EN 14362-1 (2012) Arylamines coming from prohibited azo dyes in textiles

Identification Information given by the client Date of receipt


number
T1703001 Nitrile Examination Gloves (2.2Mil) 08-02-2017

Hilde Rubben

Order responsible
This report may be reproduced, as long as it is presented in its entire form, without written permission of Centexbel.
The results of the analysis cover the received samples. Centexbel is not responsible for the representativeness of the samples.
In assessing compliance with the specifications, we did not take into account the uncertainty on the test results.

CENTEXBEL • textile competence centre • www.centexbel.be • www.vkc.be


Inrichting erkend bij toepassing van de besluitwet van 30-01-1947 • Établissement reconnu par application de l'arrêté-loi du 30-01-1947
GENT • Technologiepark 7 • BE-9052 Zwijnaarde, Belgium • phone +32 9 220 41 51 • fax +32 9 220 49 55 • gent@centexbel.be
GRÂCE-HOLLOGNE • Rue du Travail 5 • BE-4460 Grâce-Hollogne, Belgium • phone +32 4 296 82 00 • g-h@centexbel.be
KORTRIJK • Etienne Sabbelaan 49 • BE-8500 Kortrijk, Belgium • phone +32 56 281828 • fax +32 56 281830 • info@vkc.be
VAT BE 0459.218.289 • IBAN BE44 2100 4729 6545 • BIC GEBABEBB
Analysis Report 17.00808.02
Date 07-03-2017
Page 2/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Determination of resistance of water leak and air leak
Date of ending the test 23-02-2017
Standard used EN 374-2 (2014)
Deviation from the standard -
Number of gloves 2x4
Visual inspection Pass
Water leak test
Does the glove do fulfil the requirements of the test ?
Size Immediately After 2 min.
#1 M ok ok
#2 M ok ok
#3 M ok ok
#4 M ok ok
Air leak test
Does the glove do fulfil the requirements of the test ?
Size Used pressure After 30 seconds
#1 M 3 kPa ok
#2 M 3 kPa ok
#3 M 3 kPa ok
#4 M 3 kPa ok

Performed in the physical lab Ghent under the responsibility of Filip Ghekiere
Analysis Report 17.00808.02
Date 07-03-2017
Page 3/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Determination of tearing resistance - gloves
Date of ending the test 07-03-2017
Standard used EN 388-6.3 (2016)
Product standard EN 388 (2016)
Deviation from the standard -
Conditioning 23°C, relative humidity 50%
Apparatus Instron, type CRE, class 0,5
Cell 100 N
Rate 100 mm/min
Number of test specimens 2 (Length direction)
2 (Width direction)
Calculation Automatic - the highest peak

One layer material


Tear resistance (N)
Length 0.320
Length 0.470
Width 0.300
Width 0.290
Minimum 0.290 N
Classification level

Level 1 Level 2 Level 3 Level 4 Level 5


10 N 25 N 50 N 75 N -

Performed under accreditation in the physical lab Ghent under the responsibility of Filip Ghekiere
Analysis Report 17.00808.02
Date 07-03-2017
Page 4/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Determination of the abrasion resistance on Martindale with emery paper
Date of ending the test 22-02-2017
Standard used EN 388-6.1 (2016)
Product standard EN 388 (2016)
Deviation from the standard -
Conditioning 23°C, relative humidity 50%
Apparatus Martindale Wear and Abrasion Tester
Used pressure 9 kPa
Abradant Klingspor PL31B Gritt 180
Number of test specimens 4
Specimens tested by 4

One layer material, measured at 60"


Number of cycles to
breakdown the specimen
#1 0 >< 100
#2 0 >< 100
#3 0 >< 100
#4 0 >< 100
Minimum 0 >< 100
Classification level

Level 1 Level 2 Level 3 Level 4 Level 5


100 cycli 500 cycli 2000 8000 -
cycli cycli

Performed under accreditation in the physical lab Ghent under the responsibility of Filip Ghekiere
Analysis Report 17.00808.02
Date 07-03-2017
Page 5/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Determination of the puncture resistance
Date of ending the test 07-03-2017
Standard used EN 388-6.4 (2016)
Product standard EN 388 (2016)
Deviation from the standard -
Conditioning 23°C, relative humidity 50%
Apparatus Instron, type CRE, class 0,5
Cell 100 N
Perforation speed 100 mm/min
Used spike Test spike of steel with rounded top
Maximum displacement 50 mm
Number of test specimens 4

One layer material, measured at 60"


Specimen Force (N)
#1 8.66
#2 8.22
#3 9.45
#4 10.1
Minimum 8.22 N
Classification level

Level 1 Level 2 Level 3 Level 4 Level 5


20 N 60 N 100 N 150 N -

Performed under accreditation in the physical lab Ghent under the responsibility of Filip Ghekiere
Analysis Report 17.00808.02
Date 07-03-2017
Page 6/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Determination of the blade cut resistance
Date of ending the test 06-03-2017
Standard used EN 388-6.2 (2016)
Product standard EN 388 (2016)
Deviation from the standard -
Conditioning 23°C, relative humidity 50%
Apparatus Coupetest
Number of test specimens 2
One layer material, measured at 60"
Direction /
Ref. fabric Test specimen 1 Ref. fabric Index
#1 1.0 0.1 1.2 1.09
#2 1.2 0.1 1.2 1.08
#3 1.2 0.1 1.0 1.09
#4 1.0 0.1 1.1 1.10
#5 1.1 0.1 1.2 1.09
Average 1.1 0.1 1.1 1.1
Direction \
Ref. fabric Test specimen 2 Ref. fabric Index
#1 1.2 0.1 1.1 1.09
#2 1.1 0.1 1.1 1.09
#3 1.1 0.1 1.3 1.08
#4 1.3 0.1 1.3 1.08
#5 1.3 0.1 1.3 1.08
Average 1.2 0.1 1.2 1.1
Classification level

Level 1 Level 2 Level 3 Level 4 Level 5


1.2 2.5 5.0 10.0 20.0

Performed under accreditation in the physical lab Ghent under the responsibility of Filip Ghekiere
Analysis Report 17.00808.02
Date 07-03-2017
Page 7/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Determination of the dimensions of gloves
Date of ending the test 23-02-2017
Standard used EN 420 6.1 (2003) + A1 (2009)
Product standard EN 420 (2003) + A1 (2009)
Deviation from the standard The circumference is measured on the outside of the glove
Number of gloves 2x2
Size Total length (mm) Length of the top of Circumference (mm)
the middle finger
until the wrist (mm)
#1 M - 245 185 180
#2 M - 245 190 194
#3 M - 250 190 190
#4 M - 248 194 194

Performed in the physical lab Ghent under the responsibility of Filip Ghekiere
Analysis Report 17.00808.02
Date 07-03-2017
Page 8/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Determination of the pH of an aqueous extract
Date of ending the test 22-02-2017
Standard used ISO 3071 (2005)
Product standard EN 420 (2003) + A1 (2009)
Deviation from the standard -
Electrode used Combined glass-electrode
Extraction liquid KCl
Results
pH of the extraction liquid 5.6
Temperature of the extract in °C 23
Tested colour(s) Blue
Extract pH
2 8.4
3 8.6
Average 8.5

Performed under accreditation in the chemical lab under the responsibility of Eddy Albrecht
Analysis Report 17.00808.02
Date 07-03-2017
Page 9/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Permeation of liquid chemicals through a protective clothing material
Date of ending the test 22-02-2017
Standard used EN 16523-1 (2015)
Product standard ISO 374-1 (2016)
Deviation from the standard
Method Each test cell consists of a two-chambered cell for contacting
the material with a hazardous liquid. One chamber cell is
designated to contain the hazardous liquid chemical and the
other cell to contain the collecting medium.
Permeation cell Internal diameter: 25 mm; sampling shell : 35 mm; shell for
testing article : 35 mm; volume: 17.2 cm³
Exposed area of the material 4.9 cm²
Sampling Continuous sampling of the collecting medium.
Analytical method Conductivity detector
Breakthrough time 1 µg/min cm²
Results
Test liquid K:NaOH, 40%
Calibration curve NaOH
Collection medium (Flow rate) Demineralised water (35 ml/min ± 4ml/min)
Temperature in °C 22
Lining Not applicable
Observations No visible changes

Performed under accreditation in the chemical lab under the responsibility of Silke Mussche
Analysis Report 17.00808.02
Date 07-03-2017
Page 10/18

Sample Thickness (mm) Breakthrough


time(min)
1 palm 0.07 > 480
2 palm 0.07 > 480
3 palm 0.07 > 480
Average 0.07
Minimum > 480

Performed under accreditation in the chemical lab under the responsibility of Silke Mussche
Analysis Report 17.00808.02
Date 07-03-2017
Page 11/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Permeation of liquid chemicals through a protective clothing material
Date of ending the test 24-02-2017
Standard used EN 16523-1 (2015)
Product standard ISO 374-1 (2016)
Deviation from the standard
Method Each test cell consists of a two-chambered cell for contacting
the material with a hazardous liquid. One chamber cell is
designated to contain the hazardous liquid chemical and the
other cell to contain the collecting medium.
Permeation cell Internal diameter: 25 mm; sampling shell : 35 mm; shell for
testing article : 35 mm; volume: 17.2 cm³
Exposed area of the material 4.9 cm²
Sampling Continuous sampling of the collecting medium.
Analytical method PID (Photo-ionisation Detector)
Breakthrough time 1 µg/min cm²
Results
Test liquid J:Heptane, n-
Calibration curve J:Heptane, n-
Collection medium (Flow rate) Dry air (500 ml/min ± 50 ml/min)
Temperature in °C 23
Lining Not applicable
Observations No visible changes

Performed in the chemical lab under the responsibility of Silke Mussche


Analysis Report 17.00808.02
Date 07-03-2017
Page 12/18

Sample Thickness (mm) Breakthrough


time(min)
1 palm 0.07 36
2 palm 0.07 34
3 palm 0.07 35
Average 0.07
Minimum 34

Performed in the chemical lab under the responsibility of Silke Mussche


Analysis Report 17.00808.02
Date 07-03-2017
Page 13/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Permeation of liquid chemicals through a protective clothing material
Date of ending the test 24-02-2017
Standard used EN 16523-1 (2015)
Product standard ISO 374-1 (2016)
Deviation from the standard
Method Each test cell consists of a two-chambered cell for contacting
the material with a hazardous liquid. One chamber cell is
designated to contain the hazardous liquid chemical and the
other cell to contain the collecting medium.
Permeation cell Internal diameter: 25 mm; sampling shell : 35 mm; shell for
testing article : 35 mm; volume: 17.2 cm³
Exposed area of the material 4.9 cm²
Sampling Continuous sampling of the collecting medium.
Analytical method FID (Flame Ionisation Detector)
Breakthrough time 1 µg/min cm²
Results
Test liquid A:Methanol
Calibration curve A:Methanol
Collection medium (Flow rate) Dry air (500 ml/min ± 50 ml/min)
Temperature in °C 23
Lining Not applicable
Observations No visible changes

Performed in the chemical lab under the responsibility of Silke Mussche


Analysis Report 17.00808.02
Date 07-03-2017
Page 14/18

Sample Thickness (mm) Breakthrough


time(min)
1 palm 0.07 <5
2 palm 0.06 <5
3 palm 0.07 <5
Average 0.07
Minimum <5

Performed in the chemical lab under the responsibility of Silke Mussche


Analysis Report 17.00808.02
Date 07-03-2017
Page 15/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Determination of resistance to degradation by chemicals – perforation test
Date of ending the test 23-02-2017
Standard used EN 374-4 (2013)
Product standard ISO 374-1 (2016)
Deviation from the standard
Method Sample is exposed to a chemical product for a certain time.
Afterwards, the perforation resistance is determined
relatively to non-exposed samples and expressed in terms of
% degradation.
Results
Test liquid A:Methanol
Lining Not applicable
Observations after exposure No visible changes
Sample % degradation
DR1 palm 64.9
DR2 palm 54.6
DR3 palm 56.0
Average 58.5
Std. Dev. 5.6

Performed in the chemical lab under the responsibility of Silke Mussche


Analysis Report 17.00808.02
Date 07-03-2017
Page 16/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Determination of resistance to degradation by chemicals – perforation test
Date of ending the test 23-02-2017
Standard used EN 374-4 (2013)
Product standard ISO 374-1 (2016)
Deviation from the standard
Method Sample is exposed to a chemical product for a certain time.
Afterwards, the perforation resistance is determined
relatively to non-exposed samples and expressed in terms of
% degradation.
Results
Test liquid J:Heptane, n-
Lining Not applicable
Observations after exposure No visible changes
Sample % degradation
DR1 palm 42.7
DR2 palm 61.0
DR3 palm 50.6
Average 51.4
Std. Dev. 9.2

Performed in the chemical lab under the responsibility of Silke Mussche


Analysis Report 17.00808.02
Date 07-03-2017
Page 17/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Determination of resistance to degradation by chemicals – perforation test
Date of ending the test 23-02-2017
Standard used EN 374-4 (2013)
Product standard ISO 374-1 (2016)
Deviation from the standard
Method Sample is exposed to a chemical product for a certain time.
Afterwards, the perforation resistance is determined
relatively to non-exposed samples and expressed in terms of
% degradation.
Results
Test liquid K:NaOH, 40%
Lining Not applicable
Observations after exposure No visible changes
Sample % degradation
DR1 palm -13.6
DR2 palm -38.3
DR3 palm -56.5
Average -36.1
Std. Dev. 21.5

Performed in the chemical lab under the responsibility of Silke Mussche


Analysis Report 17.00808.02
Date 07-03-2017
Page 18/18

Reference: T1703001 - Nitrile Examination Gloves (2.2Mil)


Arylamines coming from prohibited azo dyes in textiles
Date of ending the test 20-02-2017
Standard used EN 14362-1 (2012)
Product standard EN 420 (2003) + A1 (2009)
Preparation procedure Colorant extraction for disperse dyes and other dyes
Analysis HPLC with DAD, confirmation : APCI-LC/MS/MS
Compounds 2,4,5-Trimethylaniline, 2,4-Diaminoanisole, 2,4-
Toluylendiamine, 2-Amino-4-nitrotoluene, 2-
Naphthylamine, 3,3'-Dimethoxybenzidine, 3,3'-Dimethyl-
4,4'-diaminodiphenylmethane, 3,3'-Dimethylbenzidine,
3.3'-Dichlorobenzidine, 4,4'-Diaminobiphenylmethane,
4,4'-Methylene-bis-(2-chloroaniline), 4,4'-Oxydianiline,
4,4'-Thiodianiline, 4-Aminobiphenyl, 4-Chloro-o-
toluidine, Benzidine, o-Aminoazotoluene, o-Toluidine, p-
Chloroaniline, p-Cresidine, o-Anisidine
4-Aminoazobenzene (°)
(°) 4-aminoazobenzene degrades under the testing
conditions. When detecting possible degradation products,
the standard prescribes an additional test (EN 14362 -
accredited)
Additional EN 14362-3 test No need

Results
Tested colour(s) Blue
Tested part/parts Glove
Reporting limit 5 mg/kg
There are no carcinogenic aryl amines present in a concentration higher than the reporting
limit.

Performed under accreditation in the chemical lab under the responsibility of David Van de Vyver