HDM HDS - 100 P 000040 e 02

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

Overview

Direct Operated Directional Control Valves


Monoblock and Sectional designs
Series HDM and HDS

motion and progress

1 / 10 Classification: 430.10.40.40
Reference: 100--P--000040--E--02 / 05.2005
Contents

1 General description 3

2 Directional valve HDM / HDS


2.1 Design features 3
2.2 Technical data 4
2.3 Configuratins available 4
2.4 Spool types 5
2.5 Spool control types 5
2.6 Hand lever 5
2.7 Ordering code 6

3 Sections with PQ flow control: HDS11 / HDS15


3.1 Design features 7
3.2 Technical data 7
3.3 Ordering code 7
3.4 Types available 8

4 Solenoid operation: HDS07 / HDS11 / HDS15


4.1 Design features 10
4.2 Technical data 10
4.3 Ordering code 10

100--P--000040--E--02 / 05.2005 2 / 10
1 General description
The HDM and HDS series of valves ma- In addition, the valves are used in ge- vings. The constly piping of individual
nufactured by Bucher Hydraulics are neral machine building and in many ty- components is eliminated.
direct operated directional valves with pes of special vehicles.
In addition to the directional valve sec-
a variety of actuator types.
The sectional versions of this range of tions that are needed, a complete valve
Due to their robust design and valves make possible the assembly of block normally also requires an inlet
compact build, they are particularly a customised valve block. Sections section to ’start’ the block and an end
suitable for use in all types of mobile containing pressure-- or flow regulating section to ’finish’ it.
hydraulic systems. Typical examples elements can be incorporated in the
The monoblock version of this valve se-
of their application are found in: valve block.
ries is a compact, well thought out solu-
S tractors and mini--tractors In this way, complex and feature--rich tion for many application areas. Nume-
S agricultural machinery control systems can be integrated into rous options are also available for the
S harvesters one block with significant space sa- monoblock version.
S construction machines
S sweepers
S fork lift trucks

2 Directional valve HDM / HDS

2.1 Design features

Auxiliary valves in the ports

Spoll control

Actuation

Spool

Directional valve sectional body

Check valve

100--P--000040--E--02 / 05.2005 3 / 10
2.2 Technical data

2.2.1 Monoblock HDM140 HDM11P HDM11S HDM18 HDM25


Nominal flow rate l/min 40 45 45 70 100
Operating pressure bar 250 250 350 350 250
Max. back pressure bar 30 30 30 30 30
Number of spool
1 1 to 6 1 to 6 1 to 4 1 to 2
sections

2.2.2 Sectional HDS11 HDS15 HDS20 HDS30 HDS07

Nominal flow rate l/min 45 60 80 120 25


Operating pressure bar 280 320 320 320 250
Max. back pressure bar 30 30 30 30 20
Number of spool
1 to 10 1 to 10 1 to 10 1 to 10 1 to 10
sections

2.3 Configurations available

Configurations
1 2 3 4 5 6 7 8 20 21 23 24 30 31 32 33 34 35 36
HDM140    
HDM11P      
HDM11S            
HDM18            
HDM25              

HDS11              
HDS15                  
HDS20               
HDS30               
HDS07        

2.3.1 Actuator types


1 = with hand lever 4 = hydraulic or pneumatic (on/off) 7 = hydraulic, proportional
2 = with 1 hand lever for 2 spools 5 = electro--hydraulic (on/off) 8 = electro--hydraulic, proportional
3 = for cable operation 6 = electrical (on/off)

2.3.2 Circuitry
20 = parallel--connected (standard) 23 = with high pressure carry--over
21 = series--connected 24 = load sensing

2.3.3 Auxiliary valves


30 = with inlet pressure relief valve 33 = with service line pressure relief 35 = with proportional pressure
31 = with service line pressure relief and anti--cavitation valve compensator
valve 34 = with pilot operated check valve 36 = with pressure--compensated
32 = with anti--cavitation valve flow control valve

100--P--000040--E--02 / 05.2005 4 / 10
2.4 Spool types
A C G
1 0 2 1 0 2 1 0 2
AB A B B

S Z
1 0 2 3 1 0 2
A A B

2.5 Spool control types


01/08 02/10 03/17
201 201 201

19/20 04/128/136
201 3201

2.6 Hand lever


L55 L100 L300

100--P--000040--E--02 / 05.2005 5 / 10
2.7 Ordering code
2.7.1 Monoblock valves, series HDM
Characteristcs of the body Characteristcs of the 1st spool
H DM 1 8 0 2 K 0 1 1 5 A 0 1 L 1 0 0 O A A 1 5 B 2 6 ...
Valve model 2nd spool
140 / 11P / 11S / 18 / 25

Number of spools

Thread type
Ex. K01 = M18x1,5 (standard)

PRV setting (0 to 400 bar)


Ex. 15 = 150 bar (standard)

Spool type (see 2.4)

Spool control type (see 2.5)

Hand lever (see 2.6)

Auxiliary valves
Service line relief and anti--cavitation valve = UC
Anti--cavitation valve = C
Service line relief valve = OA

Setting for the A--line valve

Setting for the B--line valve

2.7.2 Sectional valves, series HDS


Characteristcs of the body Characteristcs of the 1st spool
HD S 1 5 0 2 T 0 1 1 5 P 0 1 0 1 K 0 1 A 0 8 L 1 0 0 O A A 1 5 B 2 6 ...
Valve model 2nd spool
07 / 11 / 15 / 20 / 30

No. of intermediate sections

Inlet section
Ex. T01 = M18x1,5 With PRV

PRV setting (0 to 400 bar)


Ex. 15 = 150 bar (standard)

End section
Ex. P01 = with T -- M18x1,5

Position of the intermediate section in the block

Body style (standard)


HDS11 = K05 with M18x1
HDS15 and HDS20 = K01 with M18x1,5
HDS30 = K02 with 3/4” or 1”

Spool type (see 2.4)

Spool control type (siehe 2.5)

Hand lever (siehe 2.6)

Auxiliary valves
Service line relief and anti--cavitation valve = UC
Anti--cavitation valve = C
Service line relief valve = OA

Setting for the A--line valve

Setting for the B--line valve

100--P--000040--E--02 / 05.2005 6 / 10
3 Sections with PQ flow control HDS11 / HDS15

3.1 Design features

BP3/AE 13HC (12 VDC) BP3/CE 13HC (12 VDC) Ports Body
BP3/AE 23HC (24 VDC) BP3/CE 23HC (24 VDC)
M18X1.5 T/K***/1

1/2” BSP T/K***/3

00VC00 BP3/AE RV1 M22X1.5 T/K***/9

M P
VDP VDPF

T E
E

00EC T P

RV3 Pe P RV2 00VC00


00VC00

3.2 Technical data HDS11 HDS15


Operating pressure bar 320
Nominal flow rate l/min 50 60
Adjustment range l/min 0--6, 12, 40 0--6, 12, 25, 50
Pressure differential (∆p) bar max. 6

3.3 Ordering code


HD S 1 5 K * * / * R V 1 - * * R V 2 - * * R V 3 - * * B P 3 - * * V D P - * *

Series
HDS11/15

Intermediate section: K100--K88--K90


Inlet section: T100--T88--T90

Setting for pressure relief valve 1: RV1/06--15--26


Blanking plug: 00VC00

Setting for pressure relief valve 2: RV2/06--15--26


Blanking plug: 00VC00

Setting for pressure relief valve 3: RV3/06--15--26


Blanking plug: 00VC00

Solenoid bypass valve: BP3/AE 13 HC (12 V.D.C.)


BP3/CE 23 HC (24 V.D.C.)
Blanking plug 00EC

Adjustable flow control valve VDP 06--12--25--50


Non--adjustable flow control valve VDPF

100--P--000040--E--02 / 05.2005 7 / 10
3.4 Types available
3.4.1 Inlet sections

HPCO = high pressure carry--over port


(can be pressurised)
P M B1 A1 B2 A2

Constant flow

VDP

residual flow
HPCO
T100
BP3/AE

T
RV1 RV2 00VC00

T100 KSTD KSTD P100


1_ 2_

D = residual flow port


(can be pressurised)
T3
P M A1 B1 A2 B2

Constant flow

VDP
residual flow

T2
T88

BP3/AE RV2

RV3

D
T88 KSTD KSTD PSERIE
1_ 2_
R = tank port
(can not be pressurised)
T3
P M A1 B1

Constant flow
residual flow

VDP

T2
T90

BP3/AE
RV2

T90 KSTD PSERIE


1_

100--P--000040--E--02 / 05.2005 8 / 10
3.4.2 Intermediate sections

HPCO = high pressure carry--over port


(can be pressurised)

B1 A1 B2 A2 P M B4 A4
Constant flow

residual flow
VDP

HPCO T2
K100
BP3/AE

00VC00
RV1 RV2

PSERIE KSTD KSTD K100 KSTD P100


1_ 2_ 3_ 4_

D= residual flow port


(can be pressurised) M T3
A1 B1 A3 B3 A4 B4

Constant flow
residual flow

VDP

P T2
K88
BP3/AE
RV2

T RV1 RV3

TSERIE KSTD K88 KSTD KSTD PSERIE


1_ 2_ 3_ 4_

R= tank port
(must not be pressurised) T3
A1 B1 P2 M A3 B3

Constant flow
residual flow

VDP

P T2
K90

BP3/AE

RV2

RV1
T
R

TSERIE KSTD K90 KSTD PSERIE


1_ 2_ 3_

100--P--000040--E--02 / 05.2005 9 / 10
4 Solenoid operation HDS 11 / HDS 15

4.1 Design features

Manual override Manual override


40 / 48

268 / 300

4.2 Technical data HDS07 HDS11 HDS15


Operating pressure bar 250 300 280
Flow rate l/min max. 30 max. 40 max. 60

4.3 Ordering code


HD S 1 5 K 2 1 1 A E 0 1 E 2 3 O A A 1 5 B 2 6

Valve model HDS07/11/15

Body type
Ex. K211 = M18x1,5

Spool type

Solenoid control
01E = 2 solenoids
02E / 03E = 1 solenoids

Coil voltage
12 V = 13
24 V = 23

Auxiliary valves
Service line relief and anti--cavitation valve = UC
Anti--cavitation valve = C
Service line relief valve = OA

Setting for the A--line valve

Setting for the B--line valve

BUCHER HYDRAULICS www.bucherhydraulics.com


Germany France Netherlands UK USA
Phone +49 7742 85 20 Phone +33 389 64 22 44 Phone +31 79 34 26 24 4 Phone +44 24 76 35 35 61 Phone +1 262 605 82 80
Fax +49 7742 71 16 Fax +33 389 65 28 78 Fax +31 79 34 26 28 8 Fax +44 24 76 35 35 72 Fax +1 262 605 82 78
info.de@bucherhydraulics.com info.fr@bucherhydraulics.com info.nl@bucherhydraulics.com info.uk@bucherhydraulics.com info.wi@bucherhydraulics.com

Switzerland Italy Austria China Product Center (Elevator)


Phone +41 33 67 26 11 1 Phone +39 0522 92 84 11 Phone +43 6216 44 97 Phone +86 10 64 44 32 38 Phone +41 41 757 03 33
Fax +41 33 67 26 10 3 Fax +39 0522 51 32 11 Fax +43 6216 44 97 4 Fax +86 10 64 44 32 35 Fax +41 41 755 16 49
info.ch@bucherhydraulics.com info.it@bucherhydraulics.com info.at@bucherhydraulics.com info.bj@bucherhydraulics.com info.nh@bucherhydraulics.com

We reserve the right of modification without prior notice.

100--P--000040--E--02 / 05.2005 10 / 10