Intelligent Key Lock Application System

Alarm event GUIDE

Version SN100K043

Copyright @ überGARD
Alarm event code manual

Alarm event (English) Alarm event (Chinese) Alarm event description SMS Email Alarm
console
1 Y Y --
Battery Connected 蓄电池恢复 SMART PSU detected battery connected
2 蓄电池丢失
Y Y Y
Battery Disconnected SMART PSU detected battery disconnected
3 蓄电池电量不足
Y Y Y
Battery Low SMART PSU detected battery low voltage
4 Y Y --
Battery Normal 蓄电池电量恢复正常 SMART PSU detected battery in optimum condition
5 Critical Key Expired Critical key has not return after the key duration. Y Y Y
(Key) 重要钥匙持有超时(钥匙) Critical key expired by key duration
6 Critical Key Expired Critical key has not return after the user duration. Y Y Y
(User) 重要钥匙持有超时(用户) Critical key expired by user duration
7 Y Y --
Critical Key Return 重要钥匙返还 Critical key has return
8 重要钥匙取用
Y Y Y
Critical Key Withdrawn Critical key has withdrawn
9 箱门开门超时
Y Y Y
Door Open Expire Door has left open for too long
10 Door Open Without Key Access to keybox and open the door, without Y Y --
Movement 开门无钥匙操作 withdraw or return key
11 取用钥匙超过限制 Y Y Y
Draw Key Excess User has withdrawn more key than the max key
12 User is being force to access key box to withdraw key Y Y Y
Duress Alarm 被强迫报警 (Access mode must be CID + PIN / UID + PIN)
13 Expired Critical Key Y Y --
Return 超时重要钥匙返还 Expired critical key has return
14 Y Y --
Expired Key Return 超时钥匙返还 Expired key has return
15 Expired Multi Access Y Y --
Key Return 超时多卡认证钥匙返还 Expired multi access key has return

Copyright @ überGARD P ag e |2
Alarm event code manual

Alarm event (English) Alarm event (Chinese) Alarm event description SMS Email Alarm
console
16 强制开门 Y Y Y
Force Open Door Unauthorized key press front door open
17 Unauthorized key press back door open Y Y Y
Force Open Door(Gate) 强制开门(后门) (for 24 keys keybox only iKLAS-R24)
18 RFID key tag not valid Y Y Y
Invalid RFID Tag 无效的RFID标签 (Unregistered or ID not readable)
19 Key already exceeded allowable usage time, define by Y Y Y
Key Expired (Key) 钥匙持有超时(钥匙) key duration
20 Key already exceeded allowable usage time, define by Y Y Y
Key Expired (User) 钥匙持有超时(用户) user duration
21 Faulty Position of keys Y Y Y
Key Pos Fault 钥匙位置错 (for mechanical key system only iKLAS-M)
22 Reminder message send to user/admin to return key Y Y --
Key Return Reminder 钥匙返还提醒 before expired
23 钥匙单元缺失 Y Y Y
Key Slot Lost Allotted key slot not found
24 钥匙箱故障 Y Y Y
Keybox Error Keybox error or lost communication with MCU
25 Keybox has recover from error, is now in normal Y Y --
Keybox Resume 钥匙箱恢复 condition
26 LAN 连接 Y N --
LAN Connected Site has connected through LAN port
27 LAN 断开 Y N Y
LAN Disconnected Site has disconnected from LAN port
28 Multi Access Key Multi access key already exceeded allowable usage Y Y Y
Expired (Key) 多卡认证钥匙超时(用户) time, define by key duration
29 Multi Access Key Multi access key already exceeded allowable usage Y Y Y
Expired (User) 多卡认证钥匙超时(钥匙) time, define by user duration

Copyright @ überGARD P ag e |3
Alarm event code manual

Alarm event (English) Alarm event (Chinese) Alarm event description SMS Email Alarm
console
30 市电停电 Y Y Y
Power Down System Power interruption / failure
31 Y Y --
Power Resume 市电恢复 System Power restored
32 Power Supply High Y Y Y
Temperature 电源高温 SMART PSU in high temperature
33 Power Supply Normal Y Y --
Temperature 电源温度正常 SMART PSU in normal temperature
34 Detected wrong key tag ID in key slot when the keybox Y Y Y
RFID Tag Wrong Slot RFID 标签位置错误 is in idle without any transaction
35 Remote Return Expired Expired key returned to key box through remote Y Y --
Key 远端超时钥匙返还 release
36 SD卡错误
Y Y Y
SD Card Error SD card not readable or accessible
37 未授权用户访问
Y Y Y
Unauth User Access Not registered user/admin access to key box
38 Unauthorized Key Y Y Y
Withdrawal 非法取出钥匙 User has withdrawn key from not assigned key group

Copyright @ überGARD P ag e |4
Alarm event code manual

NOTICE TO USERS

The iKLAS development team will constantly upgrade/improved our iKLAS system to maintain High Security Standards. We welcome feedbacks
from our customers on any improvements that can be made to our system. Therefore changes will be made to the manual as we continue to
improve our IKLAS system to better serve our customers and maintain High Security Standards. The IKLAS development team will inform our
highly valued customers of any changes to our manual.

Copyright @ überGARD P ag e |5
Alarm event code manual

Copyright @ überGARD P ag e |6

You might also like