Thermowell Calculation

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Thermowell Calculation Report according ASME-PTC-19.

3-2010

Tag N° TW-1 / TW-2 / TW-3


Drawings
Fluid Natural Gas
Fluide natual state Gas
Dynamic Viscosity μ 1.00E-02 [cP]
PROCESS DATA Operating Temperature T 60.00 [°C]
Operating Pressure P 85 [Bar]
Density ρ 59.92 [kg/m3]
Process Fluid Velocity V 14 [m/s]
Size
Pipe Inside diameter ID 146.36 [mm]
LINE DIMENSIONS Wall Thickness TPW 10.97 [mm]
Nozzle Inside diameter 'IDSupport' 34.02 [mm]
Height to Pipe OD 'HOD' 112 [mm]
Model Code
Mounting Configuration RF
Process Connection 1'' 1/2600# RF
Material SS 316
Unsupported Length'L' 200 [mm]
Protruding Length 'PL' 77.03 [mm]
THERMOWELL DIMENSIONS
Stem Root Diameter 'A' 22 [mm]
Reduced Diameter Length 'Ls' 0 [mm]
Tip Diameter 'B' 22 [mm]
Style 1-Piece Forged Flanged- Flanged- Flanged- Lap 1-Piece 0.6
Threade Welded
Frequency ratio 0.4
Bore Bore diameter 'd' 7 [mm] Partial Full Van Flange Forged d
0.80
Fillet Fillet Radius at Root 'b' 4 [mm]
0.60
Material Density ρm 8030 [kg/m3]
0.40
Mod of Elasticity at Op. Temp. E 1.98E+11 [Pa]
0.20
Material Properties Max Allowable Working Stress S 1.60E+08 [Pa]
Fatigue Endurance Limit Sf x FT 0.00
4.83E+07 [Pa]
0 5 10 15
Von Mises Stress Limit 2.40E+02 [Pa]
Reynolds Number 'Re' 1.85E+06 Velocity (m/s)
Non Dimensionals Numbers Strouhal Number 'Ns' 2.20E-01
Scruton Number 'Nsc' 5.94E-01 So,max
Dynamic Stress (Pa)
Insitu Natural Frequency fnc Allowable
3.60E+02 [Hz] 6.0E+07
Frequency Calculations Strouhal Frequency fs 1.40E+02 [Hz]
5.0E+07
Frequency Ratio fs/fnc 0.39 1
In-Line Resonance Velocity VIR 4.0E+07
6.67E+00 [m/s] Allowable
Check for inline Resonance Cyclic Stress at Support plane 'So,max' 9.03E+07 [Pa] 4.93E+07 [Pa] 3.0E+07 0
Cyclic Stress at Reduced Dia So,max (Stepped Only) 0.00E+00 [Pa] 0.00E+00 [Pa]
2.0E+07
Steady State Drag Stress at Support Plane 'Smax' 1.16E+07 [Pa] 2.40E+08 [Pa] 1
Steady State Stresses Steady State Drag Stress at Reduced Dia. Smax 1.0E+07
0.00E+00 [Pa] 0.00E+00 [Pa]
(Stepped Only)
Dynamic Stress at Support Plane So,max 4.80E+06 [Pa] 4.93E+07 [Pa] 0.0E+00 1
Dynamic Stresses Dynamic Stress at Reduced Dia. So,max (Stepped
0.00E+00 [Pa] 0.00E+00 [Pa] 0 2 4 6 8 10 12 14 16
Only) Velocity (m/s)
Pressure Check Max Stem Pressure Pc 8.50E+06 [Pa] 6.92E+07 [Pa] 1
Result Thermowell is acceptable for process conditions.
Comments Maximum velocity cosidered is 14 m/s.
No higher in-line resonance velocity is considered.
Thermowell is acceptable upto a service velocity of 14 m/s.

You might also like