Professional Documents
Culture Documents
New Modbus Type Added To KW4M Eco-POWER METER (AKW5) Lineup: WWW - Mew.co - Jp/ac/e
New Modbus Type Added To KW4M Eco-POWER METER (AKW5) Lineup: WWW - Mew.co - Jp/ac/e
● Network
● Network compatible
compatible
(1) RS485 comes standard
(2) Modbus (RTU) protocol
*Connectable to non-Panasonic PLCs.
(3) Pulse output comes standard
Modbus
compatible
devices of other
PLC with Modbus protocol companies
*Compatible with PLCs
of other companies. KW4M KT Series
Temperature Controller PLC with Modbus protocol
Product Types
Phase and wire system Rated input Current transformer Terminal type Communication protocol Model No.
MEWTOCOL AKW5111
Single-phase two-wire system • 100 to 120V/ Screw terminal
Dedicated CT type
200 to 240V AC Modbus (RTU) NEW AKW5112
(5 A/50 A/100 A/
Single-phase three-wire system • 100 to 120AC MEWTOCOL AKW5211
250 A/400 A) 11-pins
Three-phase three-wire system • 200 to 240V AC
Modbus (RTU) NEW AKW5212
*Modbus is a communication protocol developed for PLCs by Modicon Inc.
www.mew.co.jp/ac/e
■ Measurement items
Item Unit Data range
■ Input
<When using dedicated CT>
• 5A/50A/100A/250A/400A (Can be select in setting mode)
<When using secondary 5A CT>
Rating of primary side
• 1 to 999.9A (Can be select in setting mode) (MEWTOCOL type)
• 1 to 4000.0A (Can be select in setting mode) (Modbus type)
*Guarantee accuracy range: 10 to 100% of a rated current of each CT
Input current
• 1 to 999 (Can be select in setting mode) (MEWTOCOL type)
CT ratio • 1 to 4000 (Can be select in setting mode) (Modbus type)
*Used when measuring CT with secondary 5A rated current.
■ Communication protocol
Communication protocol MEWTOCOL/Modbus (RTU) (Depending on part number.)
KW4M
Power supply side K L K L Load side
Panasonic Eco- 2
POWER METER
MODE Lock
When RS485 Output Output When
1 2 OP CT1
3 4 CT2
using VT + - + - + - using VT
(䡺44.5)
Eco-POWER METER
56 7 6 7 8 9 10
(䡺1.752) 4 8 11
MODE TIME V kW/kWh 3 9
2 10 1 2 3 4 5
SET
COUNT CHARGE A 1 11
+ -
KW4M RS485
1 2
Screw terminal AKW5111 Electric power data collection and remote watching of plants and buildings
Single-phase three-wire system
100 to 120/
(5 A/50 A/100 A/ 100A AKW4802 Electric power watching in manufacturing lines
200 to 240V AC 11-pins AKW5211
Three-phase three-wire system 250 A/400 A) 250A AKW4803 Example Electric power watching using PLC with Eco-POWER METER Example Electric power watching using Web Datalogger Unit with Eco-POWER METER
400A AKW4804
● Choosing a CT E-mail function also included
Have your mobile phone notified by email if there
(5A/50A) (100A) (250A) (400A) is a significant increase in electric power usage. Gathering of logged data
AKW4801 AKW4802 AKW4803 AKW4804 • Power meter • Water meter
• Dynamometer • Gas meter
KW4S Dedicated CT A N/A N/A N/A
(AKW4111/4211) Commercial CT N/A Please refer to the types of commercial CTs we recommend Note 2).
KW4M Remotely manage collected data on the Web.
Dedicated CT A A A A Air
con
(AKW5111/5211) ditio
ner,
Ligh
ts, O
Notes 1: A: Available, N/A: Not available Web
Air
u tlets
Datalogger con
2: The commercial CT should have a secondary current rating of 1A. Unit
ditio
ner,
Ligh
ts, O
utle
ts
Air
KW4M 7 MODE key Used to move between different modes. Datalogger Datalogger
Unit
Unit Plant
8 8 SET key Used to make settings.
Food warehouse
9 9 Select key Changes the item displayed. Line graph
1 2
Screw terminal AKW5111 Electric power data collection and remote watching of plants and buildings
Single-phase three-wire system
100 to 120/
(5 A/50 A/100 A/ 100A AKW4802 Electric power watching in manufacturing lines
200 to 240V AC 11-pins AKW5211
Three-phase three-wire system 250 A/400 A) 250A AKW4803 Example Electric power watching using PLC with Eco-POWER METER Example Electric power watching using Web Datalogger Unit with Eco-POWER METER
400A AKW4804
● Choosing a CT E-mail function also included
Have your mobile phone notified by email if there
(5A/50A) (100A) (250A) (400A) is a significant increase in electric power usage. Gathering of logged data
AKW4801 AKW4802 AKW4803 AKW4804 • Power meter • Water meter
• Dynamometer • Gas meter
KW4S Dedicated CT A N/A N/A N/A
(AKW4111/4211) Commercial CT N/A Please refer to the types of commercial CTs we recommend Note 2).
KW4M Remotely manage collected data on the Web.
Dedicated CT A A A A Air
con
(AKW5111/5211) ditio
ner,
Ligh
ts, O
Notes 1: A: Available, N/A: Not available Web
Air
u tlets
Datalogger con
2: The commercial CT should have a secondary current rating of 1A. Unit
ditio
ner,
Ligh
ts, O
utle
ts
Air
KW4M 7 MODE key Used to move between different modes. Datalogger Datalogger
Unit
Unit Plant
8 8 SET key Used to make settings.
Food warehouse
9 9 Select key Changes the item displayed. Line graph
KW4M
Power supply side K L K L Load side
Panasonic Eco- 2
POWER METER
MODE Lock
When RS485 Output Output When
1 2 OP CT1
3 4 CT2
using VT + - + - + - using VT
(䡺44.5)
Eco-POWER METER
56 7 6 7 8 9 10
(䡺1.752) 4 8 11
MODE TIME V kW/kWh 3 9
2 10 1 2 3 4 5
SET
COUNT CHARGE A 1 11
+ -
KW4M RS485