Batch Controller Batch Controller: Features
Batch Controller Batch Controller: Features
Model 414
Features
y Dual relay outputs
y Overrun compensation
y Remote start/stop
y No-signal alarm
y Ticket printing with time and
date
y Displays batch total, preset
quantity, flow rate, and
accumulated total
A C C U R A C Y w Q U A L I T Y w P E R F O R M A N C E
EMS P/L
CONTREC SYST
001
120.4
l Ltrs
Delivery Tota 533.2
Model 414 Accum. Total
Ltrs
Computer/Printer Interface
Models Available Operation
An RS232 and RS422/485 option is
Model 414A Four key switches on the front facia, available for interfacing to computers
enable the batch quantity to be set, and and printers. The interface allows the
Analog input version with both linear batch operations to be started, stopped
and square law input relationships. Batch Controller to be fully controlled
or reset. from a computer via an ASCII protocol.
Model 414B To set a batch quantity, the BATCH Software drivers are included for a
Frequency input version that will accept SET key is pressed, and then the number of printers and can print a ticket
pulse and open collector inputs from ¨ and ± keys can be used to change with time and date, a sequential
opto-sensors or Hall effect devices. and increment digits. Once set, the delivery/batch number and the batch
BATCH SET key is again pressed to and accumulated totals. An optional
Model 414D return to Run mode. header for the ticket can also be
Frequency input version with an input Keypad operations are straight forward printed.
conditioning card capable of accepting and four LED's indicate the operational
mV signals from coils, 2-wire proximity status at all times. One or two stage valve control
sensors, reed switch inputs and most In Run mode, the DISPLAY key can be Two output relays provide control for
other pulse type signals. used to display flow rate, batch and single or dual stage valve operation.
accumulated total. The first relay will energise at the start
Model 414H
The unique four key function simplifies of the batch, and de-energise when the
For applications where batches are batch is complete.
operation, making the instrument suited
very short (<15 seconds) the 414H
to use by operators with minimal The second relay can be programmed
features a response time of less than
training. to energise at a set time after the start,
20ms.
and to de-energise at a set quantity
The input is identical to the 414D but Versatile performance options prior to completion of the batch. This
the scaling factor is limited to 4000 and The instrument will operate from 12 to feature enables a slow startup and slow
the input frequency range is limited to 28V dc or from 100/110/220V ac mains. shutdown of the flow.
8kHz.
The facia is fully watertight to IP65 The Batch Controller can also be
Model 414Q (Nema 4X) and is resistant to most programmed to count up from zero or
chemicals. down from the Batch quantity.
Quadrature input version where the
flowmeter produces two pulse or The standard instrument is supplied as
square wave signals 90° out of phase. panel mount. Field enclosures and
Through the phasing of signals, explosionproof enclosures are
forward and reverse flow can be optionally available.
detected.
Batch
Model 414LA Quantity
4-20mA temperature input version with Run Stop Run Reached Run
temperature correction for general
chemicals, petroleums to API tables Count Down
and LPG (see separate data sheet).
Count Up
Model 414LR
RTD temperature input version with
temperature correction for general Relay 1
chemicals, petroleums to API tables
and LPG (see separate data sheet).
Relay 2
A C C U R A C Y w Q U A L I T Y w P E R F O R M A N C E
General Frequency Input Models
Specifications
Dimension Drawings
18mm 10mm
144mm 151mm 138mm
72 mm
66 mm
20 36
+0.6
Terminals 20-36 67 0
Min.
1 14 N A +1.0
77mm 139 0
Terminals 1-14
Top View
d.c. Volts a.c. Mains
Out (Adjust) Rear Panel Terminals Panel Cut-Out
Specifications Terminal Descriptions
14 Flow Signal (Volts) Not Used Not Used Flow Input (4-20mA) PT100 (-) Not Used 14
Ordering Information
When specifying please indicate model(s) required using the following method.
414 D . 1 0 E 0
Basic Model Special Options
0 - No option
Type of Input B - Backlighting
Analog Input - A C - Conformal Coating
Power Supply
Pulse Input - B
E - 220-240V ac
Pulse or frequency input A - 110-120V ac
with signal conditioner - D D - 12-28V dc
High speed response J - 100V ac
(pulse or frequency) - H Communications
Quadrature pulse - Q 0 - No option
2 - RS232/422
Temperature
Compensation (4-20mA) - LA Mounting Options
1 - Panel mount
Temperature N - Field mount enclosure
Compensation (RTD) - LR 3- Explosionproof enclosure