Designation: F 922 – 95

Standard Test Method for


Motor Life Evaluation of an Electric Motorized Nozzle1
This standard is issued under the fixed designation F 922; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.

1. Scope 3. Terminology
1.1 This test method covers the motorized nozzle used with 3.1 Description of Term Specific to This Standard:
household or commercial vacuum cleaner systems, that is, 3.1.1 motor life—limited by failure of the motor. Failure is
combination cleaners. motor stoppage.
1.2 This test method provides a test for determining oper- 3.1.1.1 Discussion—Any failure integral with the motor
ating motor life in hours by an accelerated laboratory proce- such as armature assembly, field assembly, housing(s) bear-
dure. The motors are tested while mounted and operated in the ings, motor cooling fan, carbon brush assemblies, motor-
motorized nozzle. mounted non-resettable thermal protective devices, or any
1.3 This test method covers only the motorized nozzle. The other component judged to be integral with the motor shall be
system used to provide the airflow source is not under judged as motor stoppage.
consideration.
1.4 This test method is limited to the determination of motor 4. Significance and Use
life for an electrically powered household or commercial 4.1 The test results provide an indication of the motor life of
motorized nozzle. an electric motorized nozzle in operating life. End of motor life
1.5 The values stated in inch-pound units are to be regarded will be judged in accordance with Section 3.
as the standard. The values given in parentheses are for
information only. 5. Apparatus and Materials
1.6 This standard does not purport to address all of the 5.1 Voltage Regulator, capable of maintaining 120 6 2 V
safety concerns, if any, associated with its use. It is the rms or rated voltage of the motorized nozzle with a wave form
responsibility of the user of this standard to establish appro- that is essentially sinusoidal with 3 % maximum harmonic
priate safety and health practices and determine the applica- distortion for the duration of the test.
bility of regulatory limitations prior to use. 5.2 Voltmeter, to provide measurements accurate to within
6 1 %.
2. Referenced Documents 5.3 Timer and Switch, having the capacity to control the
2.1 ASTM Standards: off/on duty cycle of the nozzle and air flow source during the
D 75 Practices for Sampling Aggregates2 life test.
E 337 Test Method for Measuring Humidity with a Psy- 5.4 Wattmeter, to provide measurements accurate to within
chrometer (the Measurement of Wet- and Dry-Bulb Tem- 1 %.
peratures)3 5.5 Sharp-Edge Orifice Plate—The orifice, a 11⁄4-in. (32-
F 431 Specification for Air Performance Measurement Ple- mm) diameter, shall be in accordance with the orifice plate
num Chamber for Vacuum Cleaners4 illustrated in Specification F 431.
F 608 Laboratory Test Method for Evaluation of Carpet- 5.6 Plenum Chamber, conforming to the plenum chamber
Embedded Dirt Removal Effectiveness of Household specifications in Specification F 431.
Vacuum Cleaners4 5.7 Water Manometer, or equivalent instrument measuring
F 655 Specification for Test Carpets and Pads for Vacuum in increments of 0.1 in. (2.54 mm).
Cleaner Testing4 5.8 Barometer, with an accuracy of 6 0.05 in. Hg (1.27 mm
Hg), capable of measuring uncorrected barometric pressure
with scale divisions of 0.02 in. (0.51 mm) or finer.
1
This test method is under the jurisdiction of ASTM Committee F-11 on Vacuum 5.9 Thermometer, having a range of at least 18 to 80°F (−8
Cleaners and is the direct responsibility of Subcommittee F 11.30 on Durability and to +27°C) and graduated in 1°F (0.5°C) increments.
Reliability.
Current edition approved Sept. 10, 1995. Published November 1995. Originally 5.10 Psychrometer, meeting the requirements of Test
published as F 922 – 88. Last previous edition F 922 – 93. Method E 337 with thermometers graduated in increments of
2
Annual Book of ASTM Standards, Vol 04.03. 1°F (0.5°C).
3
Annual Book of ASTM Standards, Vol 11.03.
4
Annual Book of ASTM Standards, Vol 15.07.
5.11 Test Carpet, conforming to the specifications for level

Copyright © ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.

1
F 922
loop carpet as described in Specification F 655. A carpet that 7. Procedure
provides equivalent nozzle loading results may be used. 7.1 Determine initial performance. The suction of the
5.12 Carpet Padding, conforming to the padding described cleaner or airflow source with the motorized nozzle attached is
in Specification F 655. to be determined to ensure that no leaks develop to reduce load
5.13 Test Cleaner or Airflow Source—The motorized nozzle on the nozzle. For the test, the nozzle opening is to be sealed
motor life evaluation tests shall be conducted using the airflow to the ASTM plenum chamber with manometer (or equivalent)
source and voltage resulting from the components which connected to the chamber, and with the sharpedge orifice plate
compose the combination system with which the motorized in the holder. The motorized nozzle is to have the agitator drive
nozzle is to be used. If used with several systems, the one with belt connected and a new filter bag in the cleaner or airflow
the maximum airflow shall be used. source. The agitator shall be operating freely with the handle in
5.13.1 Option—A simulated airflow source and adjusted operating position as shown in Fig. 1.
voltage may be used if they are equal to or exceed the 7.1.1 With the motorized nozzle opening sealed to the
combination system with which the motorized nozzle is to be plenum chamber and without an orifice plate in the holder,
used. energize the cleaner and motorized nozzle at a regulated 120 6
5.14 Test Fixture—A moving surface, covered by the test 2 V rms, 60 Hz for 5 min to stabilize motor temperatures. If the
carpet supported on the test pad, which moves with a horizon- rated voltage of the motorized nozzle is other than 120 V, run
tal reciprocating motion, for a stroke distance of 27 in. (686 it at the voltage 6 1.7 %. See 5.13 if an optional airflow source
mm) in each direction at the average rate of 1.8 ft/s (0.55 mps) is used.
which results in 24 cpm (forward and back). This motion shall
7.1.2 With the motorized nozzle operating at a regulated
be generated by rotating a 13.5-in. (343-mm) radius arm which
voltage of 120 6 2 V rms, 60 Hz and the airflow source at the
shall be connected to the platform with an arm at least 24 in.
required voltage, insert the sharp-edge orifice plate into the
(610 mm) long or equivalent. This device shall provide means
holder on the orifice box, in accordance with 5.5 and 5.6.
to hold the motorized nozzle fixed by its handle stationary in
7.1.3 Record the manometer reading of the combined power
the operating position while it is in contact with the recipro-
nozzle and airflow source as soon as the reading stabilizes.
cating surface.
5.14.1 Option—The motorized nozzle can be moved 7.1.4 Record the wattage of the nozzle on the plenum
through the same cycle as stated in 5.14 while the carpeted chamber. The wattage reading is used to monitor the nozzle
platform is held stationary. See Fig. 1. For either option, the load.
reciprocating motion shall follow the same duty cycle as 7.1.5 Repeat the test, recording the manometer and wattage
specified for the vacuum cleaner or airflow source and motor- reading of the cleaner or airflow source connected only to the
ized nozzle in 7.7. For the optional test fixture of Fig. 1, the plenum chamber.
reciprocating arm must be at either end of its horizontal motion 7.1.6 The airflow and wattage reading shall be measured
at the start of each “on” portion of the cycle. The vacuum every 168 h to determine if some component has failed and
cleaner or airflow source shall be stationary and positioned so degraded performance, reducing the load on the nozzle during
that the hose will be submitted to minimum stresses. the life test. If degradation exceeds 40 % see 7.10.
5.15 Test Dirt, Wedron sand/talc mixture. See Annex A1. 7.1.7 Monitor the suction at the motorized nozzle daily
during the test, in addition to the weekly measurement on the
6. Sampling plenum chamber, to maintain loading and to ensure that no
6.1 Test a minimum of three units or a larger sample size if mechanical problems exist.
desired. Select all samples at random in accordance with good 7.2 Use a new section of carpet and padding in accordance
statistical practice. Results shall provide an 80 % confidence with 5.11 and 5.12 without holes, tears, or other signs of wear
level within 6 10 % of the mean value. If not, test additional when the test is started. Tautly secure the carpet. The lay of the
samples or reduce the results by the penalty factor as calculated carpet pile shall be such that during the forward stroke the
in 7.12. powered nozzle moves in the direction of the lay of the carpet

FIG. 1 Test Fixture

2
F 922
pile. See Fig. 1. Measure the carpet pile height to determine 7.10.1 Airflow Loss—In accordance with the procedure in
carpet wear in accordance with 7.5.1. Annex A2, the suction at the start of the test, 7.1.3, is to be used
7.3 Install the motorized nozzle on the test fixture, as shown as the base for determining the 40 % degradation of perfor-
in Fig. 1, with the nozzle connected to the airflow source. mance. Measure suction with and without the motorized nozzle
7.4 If various settings are provided, set the motor speed, to ensure degradation is in the motorized nozzle. If degradation
suction regulator, nozzle height, or a combination thereof, in is in the airflow source, replace or repair the airflow source and
accordance with the manufacturer’s specified setting for using continue test. If degradation is in the motorized nozzle,
the nozzle on the level loop test carpet and pad. The setting determine and correct the cause. Replace or repair any part,
shall be the same as that used for the Cleanability Embedded except the motor, to bring the system within performance limits
Dirt Carpet Test in Laboratory Test Method F 608. and continue the test.
7.5 Keep the load within limits by controlling changes in the 7.11 Judge the end of the test in conformance with Section
carpet, agitator brush, drive belt, or airflow source or replacing 3. Express life in terms of “on” time (hours) only.
components as determined in 7.5.1-7.5.4. 7.12 Calculate an estimate of the population mean in accor-
7.5.1 Replace the carpet when one fourth of the pile height dance with the following procedure:
is worn away, as measured in the center one third of the stroke,
7.12.1 Calculate the sample mean for units tested and the
except at the beginning and end of the stroke path.
confidence interval half-width:
7.5.2 During the life test, change the agitator brush every
n
168 h of cycling time.
7.5.3 Change drive belts every 168 h of cycling time or if
x̄ 5 ( xi
i51
(1)

they cease to drive the agitator on the test carpet prior to 168 ts
h5
h. Replace positive drive belts if they cease to function as =n
intended.
7.5.4 During the life test, change the disposable or clean the where:
reusable primary and secondary filter every 168 h of cycling x̄ 5 mean of sample,
time or when the airflow decreases 40 % due to filter clogging. n 5 sample size,
xi 5 life, in hours of “on” time, for each sample tested,
To determine if the filters must be changed or cleaned prior to
h 5 half-width of confidence interval,
the 168-h period, an initial dust clogging test shall be con- t 5 value from t distribution table for 80 % (t0.80) confi-
ducted in accordance with the procedure described in Annex dence level and degrees of freedom 5 n − 1 (see
A4. Laboratory Test Method F 608, Table A3.1), and
7.6 Perform all tests in a controlled ambient with a drybulb s 5 standard deviation of sample.
temperature of 68 to 81°F (20 to 27°C) and with a relative
humidity of 30 to 50 %. 7.12.2 Compare the sample mean and confidence interval
7.7 Operate the vacuum cleaner or airflow source (see 5.13) half-width to determine whether a penalty factor is required:
at a required voltage to obtain the desired airflow through the (1) If h # 0.1 x̄, use x̄ as the published value.
motorized nozzle. Operate the motorized nozzle at its regulated (2) If h > 0.1 x̄, test additional units to meet the confidence
and applicable voltage. Operate the vacuum cleaner or airflow level, or use the following penalty factor (D):
source and motorized nozzle from a remote on-off switch and
D 5 h 2 0.1 x̄ (2)
time with a duty cycle of 8 min of operation followed by 2 min
off following the cycle condition set forth in 5.14. Use x̄ − D as the published value.
7.8 Measure the suction of the motorized nozzle with the
airflow source initially and daily on the test fixture to provide 8. Precision and Bias
a base line for identifying if degradation has occurred. The unit 8.1 Precision—A meaningful statement cannot be made due
can then be removed and tested on the plenum chamber to to the number of components in the motor, each of which could
determine if it exceeds the degradation limitation in accordance constitute failure of the motor.
with 7.11.1 and 7.11.2.
8.2 Bias—A bias statement cannot be applied to this test
7.9 Spread 10 g of the standard dirt mixture (Annex A1) at
method as there is no standard reference for comparison.
the start of the test and once every 24 h of cycling time on the
test carpet. Spread evenly over the area traversed by the nozzle
opening. 9. Keywords
7.10 Test for degradation of performance every 168 h of 9.1 durability; electric motorized nozzle; standard test
cycling time. method; vacuum cleaner

3
F 922
ANNEXES

(Mandatory Information)

A1. DIRT MIXTURE

A1.1 Test Dirt 16.0 210 to 299


A1.1.1 Ten grams of the test dirt consists of the following: % µm

90 % (wt) 9 g of silica sand5 and 15.0 149 to 209


10 % (wt) 1 g of unscented commercial-grade talcum6 3.0 105 to 148
trace 74 to 104
A1.2 Analysis of Silica Sand A1.3 Analysis of Unscented Commercial-Grade Talcum
% µm
% µm
1.0 >420
0.5 >44
35.0 300 to 419
12.5 20 to 43.9
27 10 to 19.9
23 5 to 9.9
5 20 2 to 4.9
Wedron No. 504 Unground Silica Sand, or equivalent, has been found
8 1 to 1.9
satisfactory for this purpose. It is available from Wedron Silica Co., Customer 9 <0.9
Service Dept., P.O. Box 119, Wedron, IL 60557. The test dirt must be sieved to
ensure conformance with the analysis limits. Use Practices D 75. A1.4 Mixing
6
USP Grade Supreme Talc, or equivalent, has been found satisfactory for this
purpose. It is available from Luzenac America, Inc., 9000 E. Nichols Ave., Suite A1.4.1 Thoroughly mix the two dirt quantities in a suitable
200, Englewood, CO 80112. container-dispenser.

A2. METHOD FOR DETERMINING 40 % DEGRADATION OF PERFORMANCE

A2.1 One requirement for life test is to ensure that test requirement for airflow/suction load is maintained.
airflow/suction performance at the motorized nozzle has not
degraded below 40 % of original. This is to ensure suction A2.2 Derivation:
loading on the motor. This degradation can be based on a
Q1 5 21.844 D 2 · K · =h1 (A2.2)
reduction of initial suction since there is a direct relationship
between suction and airflow. The point at which steps must be Since D2 and K are constants, then Q1/Q2 5 =h1 / =h2
taken to correct the airflow loss, based on suction, is deter- and Q2 5 0.6 Q1 at the point when servicing may be required.
mined as follows: Therefore, Q2/0.6Q1 5 =h1 / =h2 or h2 5 0.6Q1, or
h2 5 0.36h1 (A2.1) h2 5 0.36, h1 at the servicing point.
where: A2.3 Terms:
h2 5 suction at monitoring point, in. (mm), and
h1 5 initial suction, in. (mm).
Therefore, instead of setting up the test unit on the orifice box Q1 5 initial airflow,
to determine airflow for calculating degradation of perfor- Q2 5 airflow at servicing point,
mance every 168 h during the test, all that is required is to h1 5 initial suction, and
D 5 orifice diameter.
measure the suction, correct it, and as long as h2 > 0.36h1, the

A3. CORRECTION OF DATA TO STANDARD CONDITIONS

A3.1 Air Density Ratio—The density ratio, Dr, is the ratio Dr 5 @17.68Bt 2 0.001978Tw2 1 0.1064Tw (A3.2)
of the air density at the time of test, rtest, to the standard air 1 0.0024575Bt ~Td 2 Tw! 2 2.741#/~Td 1 459.7! (A3.2)
density, rstd 5 0.0750lb/ft3(1.2014 kg/m3). It is used to correct
the vacuum and wattage readings to standard conditions. Find where:
r (lb/ft3 or kg/m3) from standard psychrometric charts or Bt 5 test station pressure at time of test, in. Hg,
ASHRAE tables and calculate Dr as follows: Td 5 dry-bulb temperature at time of test, °F, and
rtest
Tw 5 wet-bulb temperature at time of test, °F.
Dr 5 rstd (A3.1)
NOTE A3.1—This equation is intended for use in correcting for ambient
As an alternative, use the following equation:

4
F 922
conditions where the barometric pressure exceeds 27 in. Hg and the dry- h 5 manometer reading, and
and wet-bulb temperatures are less than 100°F (37.8°C). Cs 5 correction factor.
A3.2 Corrected Suction—Calculate the corrected suction, A3.2.1 Optional—For series universal motors, calculate the
hs, as follows: h times the correction factor, Cs, or: correction factor, Cs, as follows:
hs 5 h 3 C s (A3.3) Cs 5 1 1 0.667 ~1 2 Dr! (A3.4)

where:

A4. METHOD TO DETERMINE TIME TO CHANGE OR CLEAN PRIMARY FILTER

A4.1 First, determine the suction reading which relates to (Annex A1) at a rate of 10 g/min into the primary filter until 70
the 40 % airflow loss using the procedure in Annex A2. g of test dirt or the 40 % airflow point is reached. If less than
70 g is collected before the cutoff point, an approximate time
A4.2 Next, set up the test cleaner to the plenum chamber to change the filters can be determined, that
under the same conditions as used for the initial airflow
is, pickup⁄10 5 number of test days between filter changes.
performance check (7.1). Feed the standard dirt mixture

The American Society for Testing and Materials takes no position respecting the validity of any patent rights asserted in connection
with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such
patent rights, and the risk of infringement of such rights, are entirely their own responsibility.

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM Headquarters. Your comments will receive careful consideration at a meeting of the responsible
technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your
views known to the ASTM Committee on Standards, 100 Barr Harbor Drive, West Conshohocken, PA 19428.

This standard is copyrighted by ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States. Individual
reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at 610-832-9585