Customer Kelompok 1 & 2 PDD Sample Creation Date : 21/01/2021 Project Lab Beton
Test Machine : MTS Criterion C64_106
Sample ID P10 Method : MTS STH ISO 6892-1 Metal
Tension Round (Actuator).msm
Standard : SNI 2025-2017
Method Description: This method is designed according to ISO 6892-1 2009. It is intended for use of
performing a tension test without using an extensometer. To switch specimen geometry from one to
another:
(1) Select the area calculation for the specimen geometry in the Area Formula dropdown list.
(2) Select the specimen geometry, round or rectangular, from the Specimen Shape dropdown list in
the PanelInputs.
(3) In the Post-Specimen section of Test Flow, choose Final Diameter as post-test input if testing a
roundspecimen, and Final Width and Final Thickness if testing a rectangular specimen.
(4) In the result Review page, choose the Final Diameter as a result if testing a round specimen, and
FinalWidth and Final Thickness as results if testing a rectangular specimen.
Specimen Results:
PLP : Muhammad Rivai Ramli, S.T.
Makassar, 22/01/2021
LABORATORIUM PENGUJIAN STRUKTUR
JURUSAN TEKNIK SIPIL
POLITEKNIK NEGERI UJUNG PANDANG
Jl.Perintis Kemerdekaan KM.10 Tamalanrea Makassar 90245 Telp.(0411) 585365, 585367, 535368 Fax. (0411) 586043
---------------------------------------------------------------------------------------------------------------------------------------
-------------
Customer Kelompok 1 & 2 PDD Sample Creation Date : 21/01/2021 Project Lab Beton
Test Machine : MTS Criterion C64_106
Sample ID S13 Method : MTS STH ISO 6892-1 Metal
Tension Round (Actuator).msm
Standard : SNI 2025-2017
Method Description: This method is designed according to ISO 6892-1 2009. It is intended for use of
performing a tension test without using an extensometer. To switch specimen geometry from one to
another:
(1) Select the area calculation for the specimen geometry in the Area Formula dropdown list.
(2) Select the specimen geometry, round or rectangular, from the Specimen Shape dropdown list in
the PanelInputs.
(3) In the Post-Specimen section of Test Flow, choose Final Diameter as post-test input if testing a
roundspecimen, and Final Width and Final Thickness if testing a rectangular specimen.
(4) In the result Review page, choose the Final Diameter as a result if testing a round specimen, and
FinalWidth and Final Thickness as results if testing a rectangular specimen.
Specimen Results:
PLP : Muhammad Rivai Ramli, S.T.
Makassar, 22/01/2021