Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

HEAT LOAD SUMMARY Date : 04-06-18

PROJECT : Mr.Bala Appartment Rev - R0


Deh.Air Tonnage
Carpet Carpet Tonnage Deh.Air Quantity
Fresh Air Quantity As per Unit
Sl/No Space Area Area Design Temperature Occupancy As per HAP in CFM Electrical Requirement Remarks
CFM in CFM Selection
in Sqmt. in Sqft. in TR As per Unit Selection
As per HAP in TR
Lower Floor
1 Bedroom - 02 24.4 262.6 23±10C 2 26 1.2 585 1.6 582 6amp Socket near indoor unit
2 Master Suite 01 52.8 568.3 23±10C 2 44 1.9 896 2.6 883 6amp Socket near indoor unit
3 Kitchen 26.4 284.2 23±10C 0.6 265 0.8 265 6amp Socket near indoor unit
4 Dining 36.7 395.0 23±10C 10 74 1.2 417 1.3 459 6amp Socket near indoor unit
5 Bedroom - 03 20.5 220.7 23±10C 2 23 0.9 387 1.3 459 6amp Socket near indoor unit
6 Living 68.4 736.3 23±10C 6 74 1.3 482 1.6 582 6amp Socket near indoor unit
Double Heght
7 41.2 443.5 23±10C 12 87 3 1344 4.5 1377 6amp Socket near indoor unit
Entrance
6 Server Room 0 0.0 23±10C 1 300 1 282 6amp Socket near indoor unit

Upper Floor
8 Bedroom - 05 24.4 262.6 23±10C 2 26 1.2 602 1.6 582 6amp Socket near indoor unit
9 Master Suite 02 52.8 568.3 23±10C 2 44 1.9 896 2.6 883 6amp Socket near indoor unit
10 Family Lounge 72.6 781.5 23±10C 7 82 1.3 466 1.3 459 6amp Socket near indoor unit
11 Bedroom - 04 33.1 356.3 23±10C 2 31 1 454 1.3 459 6amp Socket near indoor unit
12 Home Theater 61.4 660.9 23±10C 8 80 2.1 841 2.6 883 6amp Socket near indoor unit

Total 5540 19 7935 24 8155


Indoor Unit total capacity 24TR
Outdoor unit selection based on without Diversity 30 HP
Outdoor unit selection based on diversified load @80% 24HP 18 Kw

HL SUMMARY.xls /HLoad-Matrix