Control Room at OHT
6.17 Cum
2 ISSR Vol- II Earthwork in excuvation by mechanical / manual
2.7 means over areas (exceeding 30 cm in depth , 1.5
Page 15 m in width as well as 10 sq.m on plan) including
disposal of excuvated earth lead upto 50m
disposal earth to be levelled and neatly dressed.
4.11 Cum
Ordinary rock 1.44 Cum
Hard rock (blasting prohibited) 2.67 Cum
3 ISSR Vol- I 15.18(a) Providing & laying mechanically mixed cement
Page 153 concrete 20mm maximum size graded crushed
stone including cost of centering & shuttering.
Over doors
D1 1 1.30 0.60 0.06 0.05 Cum
D2 1 1.05 0.60 0.06 0.04 Cum
Over window
W 2 1.80 0.60 0.06 0.13 Cum
W1 1 1.50 0.60 0.06 0.05 Cum
Total 0.27 Cum
H Steps 6 1.00 0.30 0.15 0.27 Cum
7 ISSR Vol- I Providing and laying Damp proof course 40mm
4.9 thick with Cement concrete M-15 (nominal mix)
Page 36 with 10/12 maximum size of stone aggregate.
Windows
W 2 1.50 - 1.20 3.60 sq.m
W1 1 1.20 - 1.20 1.44 sq.m
Ventilators v 1 0.60 - 0.75 0.45 sq.m
Total 5.49 sq.m
17 ISSR Vol- II Finishing walls with Acrylic smooth exterior paint
13.46 of required shade New work (two or more coat
Page 161 applied @ 1.67 litres /10 sqm over and including
base coat of water proofing cement paint applied
@2.0 kg/10sqm (including labour charges)
52.41 Sqm
18 ISSR Vol- II Painting with synthetic enamel paint of approved
13.61 brand and manufacture to give an even shade:2
Page 163 or more coats on new work
18.33 Sqm
19 ISSR Vol- I Providing and placing in position cold twisted or
15.22(A) un-coated HYSD steel bar and hot rolled deformed
Page 155 steel reinforcement for R.C.C. work i/c cutting,
bending, binding etc. complete i/c cost of binding 775.47 Kgs
wire and wastage.
16 amps 1 1 Nos
23 ISSR Vol- IV Supplying and drawing single core PVC insulated
4.3.1 cable FR with copper multi strand conductor ISI
Page 30 marked in existing rigid conduit in surface or
concealed as per specification
1 1 Each
Sl. Ref. Description No. L B D/H Qty. Unit
No
29 ISSR Vol- IV Add extra for using salt and charcoal/coke for pipe
11.2 earth electrode as reqired including excavation
Page 64 &refilling .
1 1.00 Each
37 ISSR Vol- II providing and fixing square mouth S.W gully trap
24.1 grade A complete with C.I grating brick masonry
Page 236 chamber with water tight C.I cover with frame of
300x300 mm size (inside the weight of cover to be
not less than 4.5 kg and frame to be not less than
2.7 kg as per standard design : with modular brick
class designation 40