Service Data Sheet

Ref. No. PM-02-301-A


December 2008 Electrical Reliability Services

Partial Discharge Testing for Cables


Performed online without
disrupting plant or facilities,
or offline when required

Non-destructive, non-
invasive predictive
maintenance tool

Optimizes capital
expenditures and improves
system reliability

Helps eliminate unplanned


outages and lost profit as a
result of system downtime

Identifies and prioritizes


cable sections and
terminations for replacement

Focus on the right cables


for targeted investment -
minimizes unnecessary
spending
Condition Assessment of Discharge testing and monitoring
Cables can provide critical information
Partial Discharge can occur at regarding the quality of insulation
voids, gaps and similar defects in and its impact on cable system
medium and high voltage cable health. By detecting and trending
systems. If allowed to continue, partial discharge, it is possible to
partial discharge will erode the observe its development over time
insulation, usually forming a tree- in order to assist asset managers
shaped pattern of deterioration with strategic decisions regard-
(electrical tree) and eventually ing the repair or replacement of
result in complete breakdown the cable—prioritizing capital and
and failure of the cable or ac- MRO investments before an unex-
cessory. Such failures cause pected outage occurs.
unplanned power outages, loss
of plant production, equipment
damage, and/or personnel injury.
Data obtained through Partial

www.assetweb.com/ers
Service Data Sheet
December 2008

Integrated Partial Innovative Technology predictive maintenance tool


Discharge Solutions for Emerson’s innovative technology that assesses the condition of
Cables is the most advanced, flexible aging cable systems including
Emerson’s integrated Partial and robust technology on the splices and terminations. With
Discharge testing and monitoring market today, suitable for both Emerson’s innovative online
solutions include both online online and offline testing. PD technology, accuracy is improved
and offline testing, and periodic measurements are made using a through the use of the cable PD
and continuous monitoring of range of calibrated sensors that mapping software and by testing
your cables. Depending on your are either inductively, capacitively multiple points of attachments
specific operating requirements or acoustically coupled to the over shorter cable lengths—not a
and application, Emerson can cable. Signals are captured viable option with offline testing.
customize a program that best synchronously across the 60 Hz Another distinct advantage is its
fits your needs. Choose from the power cycle via our test application ability to test branched circuits on
following: enabling the test engineer to network feeders. And, the cost to
observe phase-related patterns perform online testing is relatively
• Online Partial Discharge Testing of discharge, online and in inexpensive compared with offline
- Handheld Survey real-time. Emerson’s analysis testing that requires interruption of
- Periodic Partial Discharge application provides an automatic service and production. For critical
Testing PD criticality level for the cable facilities that operate 24x7, this is
- Continuous Online Monitoring based on magnitude and number perhaps the single best option for
• Ultrasonics of PD pulses per power cycle. Our detecting insulation condition.
• Offline Partial Discharge Testing equipment also includes a built-
• Tan Delta in RF noise reduction function, Other online testing and monitoring
• Very Low Frequency Testing separates the pulses into PD solutions for cables include
(VLF) type (cable PD, switchgear PD, permanently mounted sensors
etc.) while automatically sorting for “hard to access areas” or
Problem Identification out electrical “noise” pulses areas that pose a safety concern,
Using our integrated Partial using a single frequency spectral short-term continuous monitoring
Discharge testing and monitoring subtraction to reduce RF noise. for those cables that require
solutions, our test engineers can The online cable PD mapping monitoring under load for an
identify: technology enables the accurate extended period of time, and
detection of PD location to an permanent continuous monitoring
• Defective Cable Insulation accuracy of less than 1% of the systems for the most critical cables
• Location of Defects cable length up to approximately in your system—including those
• Extent of Insulation Degradation 3 miles of cable. This mapping that are nearing the end of their
• Defective Splices technology applies the same Time- useful life, or have demonstrated
• Defective Terminations Of-Flight (TOF) analysis of PD high levels of partial discharge
signals as used in the offline cable through other testing methods.
Measuring Method PD location methods, with the
Performed on XLPE, EPR, PILC key advantage of being able to be Ultrasonics
and CLX Armored Cable, the conducted online. All electrical equipment produces
measuring method applied is a broad range of sound. The basic
capable of detecting and localizing Online Partial Discharge Testing electrical problems that produce
discharges in any cable lengths Performed without disrupting plant distinct ultrasound waves that
in medium and high voltage cable or facility operations, Emerson’s can be detected by Ultrasonic
circuits from 4kV up to 345kV. Online Partial Discharge testing Testing include partial discharge,
is a non-destructive, non-invasive corona and tracking. Ultrasonic
Electrical Reliability Services
measurement is most powerful
on a comparative basis and will
significantly increase the reliability
of correct detection of partial
discharge when used with other
Emerson online partial discharge
testing technologies.

Offline Partial Discharge Testing


Offline Partial Discharge Testing
offers a significant advantage
over other technologies because
of its ability to measure the cable
system’s response to a specific
stress level and predict its future
performance without creating
a fault. Offline testing is also
known for its ability to pinpoint the
exact defect location on field-
aged cables, enabling the asset
manager to accurately plan for
maintenance and/or repair. Offline trees, which are a major original and recorded in accordance
testing is also commonly used in source of insulation failures in with the test plan. Once all the
conducting acceptance testing on aged extruded cables. measurements have been taken,
newly installed equipment. For offsite data analysis is performed
systems already in service, the Very Low Frequency Hipot to correlate measurements to the
challenge is that the equipment Testing (VLF) single-line drawing and analyze
must be taken out of service for the VLF is primarily used to evaluate actual PD signatures.
test to be performed. When de- insulation deterioration in cables
energization is preferred, Emerson and is one of the least expensive Report of Findings
can conduct offline testing as part ways to check the AC integrity Upon completion of the site visit,
of your predictive maintenance of cables to determine pass or data collection and analysis, we will
program. fail which is often the first level provide a written engineering report
of testing asset managers do containing detailed information
Tan Delta to prioritize cable condition for about the test results, the condition
Another offline testing solution for maintenance decisions. of your cable and accessories,
cables includes Tan Delta testing recommendations for prioritizing
which is a diagnostic tool that can Site Visit replacement or corrective actions,
measure the level of deterioration The site visit is performed by and a proposed follow-up testing
of the cable and be able to predict our technical staff and includes schedule. Each cable tested will
the life expectancy. It is also useful a comprehensive review of an be rated green, yellow, orange, or
for rating your cables on a scale up-to-date electrical single line red and a recommended action will
from high quality to low to enable diagram and a physical check be provided. The measured PD
the asset manager to prioritize of your cable systems including magnitude will also be documented
cable repair and/or replacement. A splices and terminations. The for trending purposes.
significant advantage of Tan Delta actual characteristics and partial
testing is that it can detect Water discharge activities are monitored
Service Data Sheet
December 2008 Electrical Reliability Services

Discharge within acceptable


0 pC - 3,000 pC
limits
Some concern, monitoring
3,000 pC - 6,500 pC
PLIC recommended
Cables Some concern, regular moni-
6,500 pC - 10,00 0pC
toring recommended
Major concern, repair or re-
> 10,000 pC
place

Discharge within acceptable


0 pC - 250 pC
limits
Some concern, monitoring
250 pC - 350 pC
XLPE recommended
Cables Some concern, regular moni-
350 pC - 500 pC
toring recommended
Major concern, repair or re-
> 500 pC
place
PD Tolerance Levels for MV Cables

Maximize Uptime
Partial discharge testing plays a critical role in determining the health of your electrical assets and ensuring
maximum uptime. Partial discharge testing provides asset managers with the critical information to target
maintenance resources to the areas that require the most attention.

Depending on your specific operating requirements and application, Emerson can help you develop and
implement the right combination of technology, online or offline, to meet your maintenance requirements.
Improve operational efficiency and worker safety by working with the experts at Emerson.

Emerson–Your Partner in Reliability


From installation to operation, only Emerson has the knowledge and experience to seamlessly integrate
all the essential services to deliver “high nines” reliability required by today’s critical facilities. Look to
us as your partner. We’ll be with you every step of the way with the right combination of technology,
people, and services. Contact Emerson to realize the true potential of your assets.

Emerson Process Management ©2008, Emerson Process Management


Asset Optimization Division The contents of this publication are presented for informational purposes only, and while every effort has
8760 Orion Place, Suite 110 been made to ensure their accuracy they are not to be construed as warranties or guarantees, expressed
or implied, regarding the products or services described herein or their use or applicability. All sales are
Columbus, Ohio 43240 governed by our terms and conditions, which are available on request. We reserve the right to modify or
improve the designs or specifications of such products or services at any time without notice.
T 1 (877) 468-6384
The Emerson logo is a trade mark and service mark of Emerson Electric Co.

www.assetweb.com/ers

You might also like