STR 25
- PRILIKOM IZRADE PALIRSKIH NACRTA PODRUMA, KROVIŠTA I KARAKTERISTIČNOG PRESJEKA U SKLOPU PREDMETA ELEMENTI
ZGRADA 2, OBAVEZNO JE NA VJEŽBAMA IMATI FOTOKOPIJU TLOCRTA PRIZEMLJA M 1:50 IZRAĐENU U SKLOPU PREDMETA
ELEMENTI ZGRADA 1
TLOCRT PRIZEMLJA.
- TLOCRT PODRUMA CRTAMO U MJERILU 1:50 ŠTO ZNAČI DA JE JEDAN cm NA PAPIRU JEDNAK 50 cm U PRIRODI
2 SASTAVNICA
- SE NALAZI U DONJEM DESNOM UGLU PAPIRA
9 cm
1 cm 6 cm 2 cm
0,5 0,5
3 ZIDOVI
- PODRUMSKI ZIDOVI SU LIJEVANI, NEARMIRANI, BETONSKI ZIDOVI DEBLJINE: 40 cm UKOLIKO SU U PRIZEMLJU DEBLJINE 38 cm
- BETONSKI ZIDOVI OZNAČAVAJU SE, U TLOCRTU I POGLEDU, ŠRAFIRANJEM TANKOM LINIJOM POD KUTEM OD 45 STUPNJEVA
- ZIDOVI SE ZADEBLJAVAJU PREMA UNUTRAŠNJEM PROSTORU, ŠTO ZNAČI DA VANJSKA DIMENZIJA GABARITA ZGRADE
OSTAJE ISTA KAO U PRIZEMLJU, DOK JE DIMENZIJA UNUTRAŠNJEG PROSTORA PODRUMA NEŠTO MANJA.
STR 26
- POPREČNI PREGRADNI ZIDOVI MORAJU SE NALAZITI TOČNO ISPOD POPREČNIH PEGRADNIH ZIDOVA PRIZEMLJA
1 3
100
60 60
100
1/2 1/2
1/2 1/2
2 4
STR 27
12 14 12 14 12 14 12 14 12 12 14 12 14 12 14 12 14 12
14 14 12
12 14 12
35
40
38
3
5 VRATA I PROZORI
- PROZORI SE POSTAVLJAJU NA ISTE POZICIJE NA KOJIMA SE NALAZE U PRIZEMLJU, ILI PREMA DISPOZICIJI PROSTORA
VIDI Br. 3, UKUPNO 2-3 PROZORA. PROZORI SU BEZ ROLETA SA POLUPROVIDNIM STAKLOM.
- SVIJETLA ŠIRINA PROZORA JE 70 cm ILI 120 cm ZIDARSKA ŠIRINA PROZORA JE 90 cm ODNOSNO 140 cm
- PROZORI SU IZVANA POLUUKOPANI, DOK SU IZNUTRA SA VISOKIM PARAPETOM. TO ZNAČI DA IM JE GORNJI BRID
ZA PREDLOŠKE 2 i 4 2,60 m
STR 28
7 PODZIDANO STUBIŠTE
- JE SISTEM IZVEDBE STUBIŠTA KOJI SE DANAS VIŠE NE IZVODI. U PROJEKTU JE ZADAN U SVRHU VJEŽBANJA PERCEPCIJE
- RADI SE O STUBIŠTU KOJE JE NASTUPNIM PLOHAMA OSLONJENO NA BOČNE ZIDOVE IZ OPEKE, KOJI GA
KAKO U TLOCRTNOM PRIKAZU PRIKAZUJEMO ZGRADU PRESJEČENU ZAMIŠLJENOM RAVNINOM KOJA SE NALAZI
NA VISINI 100 cm OD PODA, TAKO SREDIŠNJU PREGRADU VIDIMO KAO ZID DEBLJINE 36 cm.
CRTKANOM LINIJOM OZNAČENA JE RAZLIKA U VISINI ZIDOVA, TE ODVAJANJE SREDIŠNJEG PREGRADNOG ZIDA
P P
PRESJEK P X
TLOCRT PODRUMA - IZVEDBENI PROJEKT
STR 29
8 ULAZNI PODEST
- U TLOCRTU PODRUMA VIDLJIVI SU TEMELJI ULAZNOG PODESTA
- TEREN OKO ZGRADE NALAZI SE NA KOTI -0,45 m ILI -0,60 m U ODNOSU NA POD PRIZEMLJA Tj. KOTU + 0,00
NA PODEST SE STOGA USPINJEMO PO STUBAMA VISINE 3 X 15 cm ILI 4 X 15 cm, DOK JE ŠIRINA STUBE 30 cm.
- TEMELJE ULAZNOG PODESTA CRTAMO KAO PRSTEN PO UBODU PODESTA I STUBA, DEBLJINE 30 cm, S TIM DA JE
PRSTEN OTVOREN PREMA ZGRADI, TE DA POSTOJI DILATACIJSKI PROSTOR IZMEĐU TEMELJA PODESTA
- NA TLOCRTU TEMELJA UCRTAVAMO PREVALJENE PRESJEKE SA SVE ČETIRI STRANE, NA KOJIMA MORAJU
BITI VIDLJIVE STUBE I OSLANJANJE PLOČE PODESTA NA TEMELJE, KAO I VISINSKE KOTE.
- TEMELJE U PREVALJENIM PRESJECIMA PRIKAZUJEMO U PRIKRATI (NIJE NACRTANA STVARNA VISINA TEMELJA I TEMELJNOG ZIDA)
- MINIMALNA DUBINA TEMELJA U ZONI U KOJOJ ŽIVIMO JE 80 cm ISPOD POVRŠINE ZEMLJE (UKOLIKO SE RADI O NORMALNOM,
ČVRSTOM TLU). S OBZIROM NA NAVEDENI PODATAK, DUBINE TEMELJA ULAZNOG PODESTA BITI ĆE:
TLOCRT POGLED
TLOCRT TEMELJA
- 0,05
- 1,30
- 1,30
5 cm DILATACIJA
TLOCRT PODRUMA - IZVEDBENI PROJEKT
STR 30
9 PREVALJENI PRESJECI
- PREVALJENE PRESJEKE POTREBNO JE PRIKAZATI NA ISTIM MJESTIMA KAO U PRIZEMLJU, I UGLAVNOM SU ISTI.
U PODRUMU NE POSTOJE PREVALJENI PRESJECI SA KUTIJOM ZA ROLETU, A NOVI SU PRESJECI DANI PRIMJEROM U NASTAVKU.
30
20
10
NEMA SUSJEDA
20
40
30
+ 0,10
- 0,10
KULIR PLOČE 4 cm
- 0,10
PIJESAK 5 cm
PE FOLIJA
BET. PODLOGA 10 cm
ŠLJUNAK 15 cm
NABIJENA ZEMLJA
- 1,30 - 1,30