Euro 4/5 SCR test and startup routine Wörth plant

start of SCR test routine

check of preconditions:
- SCR-system is assembled completely
- engine can be started

preconditions
achieved?

start communication with


MR-ECU and instrument cluster

read
- MW01 and MW02 vehicle air pressure
- MW33 AdBlue filling level

no
air pressure min. 9.5 bar?
AdBlue level min. 5%?

yes

open air pressure valve


read MW37 air pressure dosing unit

no
air pressure min. 1350 mbar?

yes

close airpressure valve


activate AdBlue pump in supply unit

deaeration of
AdBlue suction wait 10sec

and return line

deactivate AdBlue pump

1 4

TM/MEP 514267733.doc / Strobel Seite 1 von 4


Euro 4/5 SCR test and startup routine Wörth plant
1 4

open
- air pressure valve
- dosing valve

activate AdBlue pump

deaeration of
AdBlue pressure read MW32 AdBlue pressure

line

no
AdBlue pressure between
2200 to 6000mbar?

yes

close dosing valve


deactivate AdBlue pump

wait 5sec

close air pressure valve

2 5

TM/MEP 514267733.doc / Strobel Seite 2 von 4


Euro 4/5 SCR test and startup routine Wörth plant
2 5

open air pressure valve


activate AdBlue pump

read MW32 AdBlue pressure

no
AdBlue pressure between
4600 to 6000mbar?

yes

deactivate AdBlue pump

AdBlue pressure
line leakage test
wait 10sec

read MW32 AdBlue pressure

no
AdBlue pressure between
4000 to 6000mbar?

yes

close air pressure valve

read
- MW31 AdBlue temperature dosing unit
- MW34 AdBlue temperature tank
- MW35 temperature before catalyst
- MW36 temperature after catalyst
check of sensor
plausibility
no
each measured value in plausible
range?

yes

3 6

TM/MEP 514267733.doc / Strobel Seite 3 von 4


Euro 4/5 SCR test and startup routine Wörth plant

3 6

check result of test routine

no
test routine finished o.k.?

yes

activate SCR function

delete error memory

ignition off

SCR-system
wait 5sec
activation

ignition on

read error memory

no
no error code active?

yes

SCR test routine finished o.k. SCR test routine finished n.o.k.
SCR functionality activated SCR functionality not activated

TM/MEP 514267733.doc / Strobel Seite 4 von 4