Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 6

VRV INDOOR UNIT SCHEDULE

Cooling Heating
Air Flow
Tmp C Rq TC Max TC Tevap Max SC Tmp H Max HC Rate
S. No LOCATION EQUIPMENT TAG EQUIPMENT MODEL
°C Sound MCA WxHxD Weight
Ton Ton °C Ton °C Ton cfm PS
(DBT/RH) dBA A mm kg
1 GR- PLAYROOM DFCU-01 FXSQ63A 24.0/50% 1.6 1.8 6 1.3 20 2.3 742 27 - 33 220V 1ph 1.6 1,000 x 245 x 800 36.5
2 GR-G BEDROOM DFCU-02 FXSQ100A 24.0/50% 2.7 2.8 6 2.1 20 3.6 1,130 31 - 36 220V 1ph 2.4 1,400 x 245 x 800 46
3 GR-IT ROOM SPLIT AC-01 FXAQ25PVE 24.0/50% 0.6 0.7 6 0.6 20 0.9 283 31 - 36 230V 1ph 0.4 795 x 290 x 238 11
4 GR-ELEC ROOM SPLIT AC-02 FXAQ25PVE 24.0/50% 0.6 0.7 6 0.6 20 0.9 283 31 - 36 230V 1ph 0.4 795 x 290 x 238 11
5 GR-OFFICE DFCU-03 FXSQ140A 24.0/50% 3.5 4 6 3 20 5.1 1,377 34 - 42 220V 1ph 3.1 1,550 x 245 x 800 51
6 GR-LAUNDERY DFCU-04 FXSQ63A 24.0/50% 1.7 1.8 6 1.3 20 2.3 742 27 - 33 220V 1ph 1.6 1,000 x 245 x 800 36.5
7 GR-BEDROOM DFCU-05 FXSQ40A 24.0/50% 1 1.1 6 0.8 20 1.4 530 29 - 35 220V 1ph 1.1 700 x 245 x 800 28.5
8 GR-LIVING DFCU-06 FXSQ80A 24.0/50% 1.9 2.2 6 1.6 20 2.8 812 29 - 35 220V 1ph 1.9 1,000 x 245 x 800 36.5
9 GR-STORE DFCU-07 FXSQ50A 24.0/50% 1.3 1.4 6 1 20 1.8 537 29 - 35 220V 1ph 1.1 700 x 245 x 800 29
10 GR-KITCHEN-1/2 DFCU-08 FXSQ140A 24.0/50% 3.8 4 6 3 20 5.1 1,377 34 - 42 220V 1ph 3.1 1,550 x 245 x 800 51
11 GR-KITCHEN-2/2 DFCU-09 FXSQ63A 24.0/50% 1.7 1.8 6 1.3 20 2.3 742 27 - 33 220V 1ph 1.6 1,000 x 245 x 800 36.5
12 MF- BEDROOM-1 DFCU-10 FXSQ50A 24.0/50% 1.3 1.4 6 1 20 1.8 537 29 - 35 220V 1ph 1.1 700 x 245 x 800 29
13 MF- BEDROOM-2 DFCU-11 FXSQ40A 24.0/50% 1.1 1.1 6 0.8 20 1.4 530 29 - 35 220V 1ph 1.1 700 x 245 x 800 28.5
22.8 24.8
14 1ST-KIDS ROOM DFCU-12 FXSQ80A 24.0/50% 2.2 2.2 6 1.6 20 2.8 812 29 - 35 220V 1ph 1.9 1,000 x 245 x 800 36.5
1ST-M.BEDROOM
15 DFCU-13 FXSQ140A 24.0/50% 3.9 4 6 3 20 5.1 1,377 34 - 42 220V 1ph 3.1 1,550 x 245 x 800 51
F-22
1ST-BEDROOM -
16 DFCU-14 FXSQ125A 24.0/50% 3.3 3.5 6 2.6 20 4.5 1,271 33 - 39 220V 1ph 2.6 1,400 x 245 x 800 47
F-19
1ST-BEDROOM - F
17 DFCU-15 FXSQ140A 24.0/50% 3.9 4 6 3 20 5.1 1,377 34 - 42 220V 1ph 3.1 1,550 x 245 x 800 51
- 10
1ST-BEDROOM - F
18 DFCU-16 FXSQ140A 24.0/50% 3.9 4 6 3 20 5.1 1,377 34 - 42 220V 1ph 3.1 1,550 x 245 x 800 51
- 3 & HALL
17.2 17.7

Abbreviation Description
Tmp C Indoor conditions in cooling
Rq TC Required total cooling capacity
Max TC Available total cooling capacity
Rq SC Required sensible cooling capacity
Tevap Evaporating temperature of indoor unit coil
Max SC Available sensible cooling capacity
Tmp H Indoor temperature in heating
Max HC Available heating capacity
Sound Sound pressure level low and high
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Weight Weight of the device
Air Flow Rate Air Flow Rate
VRV OUTDOOR UNIT SCHEDULE (FOR INDOOR VRV UNITS)
Cooling Heating
CR Piping
Tmp C CC Rq CC Tmp H HC Rq HC
Location Equip Tag Model
°C
% °C Ton Ton Ton Ton m
(DBT/RH)
ROOF GR-VRV-01 RXYTQ40UYF 87.8 46 23.4 22.8 0.0/86% 25.1 0 50
ROOF 1ST-VRV-02 RXYTQ32UYF 78.1 46 18.2 17.2 0.0/86% 19.9 0 50

MCA MOP RLA FLA WxHxD Weight


Equip Tag Sub Tag Model PS
A A A A mm kg

RXYTQ40UYF

GR-OU-VRV-01-A - RXYTQ14UYF 27 32 15.8 1,240 x 1,685 x 765 283


400V
GR-VRV-01 GR-OU-VRV-01-B - RXYTQ14UYF 27 32 15.8 1,240 x 1,685 x 765 283
3Nph
GR -OU-VRV-01-C - RXYTQ12UYF 24 32 12.7 1,240 x 1,685 x 765 234

RXYTQ32UYF

1ST-OU-VRV-01-A - RXYTQ16UYF 400V 31 40 19.3 1,240 x 1,685 x 765 283


1ST-VRV-01
3Nph
1ST-OU-VRV-01-B - RXYTQ16UYF 31 40 19.3 1,240 x 1,685 x 765 283

Abbreviation Description
CR Connection ratio
Tmp C Outdoor conditions in cooling
CC Available cooling capacity
Rq CC Required cooling capacity
Tmp H Outdoor conditions in heating (dry bulb temp. / RH)
HC Available heating capacity (integrated heating capacity)
Piping Largest distance from indoor unit to outdoor unit
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
MOP Maximum Overcurrent Protection
FLA Fan Motor Input
RLA Nominal Running Amps
WxHxD WidthxHeightxDepth
Weight Weight of the device
VRV OUTDOOR UNIT SCHEDULE (FOR INDOOR AHU UNITS)
Cooling Heating
CR Piping
Tmp C CC Rq CC Tmp H HC Rq HC
Location Equip Tag Model
°C
% °C Ton Ton Ton Ton m
(DBT/RH)
ROOF VRV-AHU-01 RXYTQ22UYF 85.6 46 15.5 15 0.0/86% 14.3 0 7.5
ROOF VRV-AHU-02 RXYTQ30UYF 84.9 46 19.8 19 0.0/86% 19.5 0 7.5
ROOF VRV-AHU-03 RXYTQ26UYF 82.1 46 17.8 17 0.0/86% 16.7 0 7.5
ROOF VRV-AHU-04 RXYTQ18UYF 90.7 46 13 13 0.0/86% 10.8 0 7.5
ROOF VRV-AHU-05 RXYTQ14UYF 76.3 46 9.4 8.5 0.0/86% 8.2 0 7.5
ROOF VRV-AHU-06 RXYTQ30UYF 84.9 46 19.8 19.5 0.0/86% 19.5 0 7.5

MCA MOP RLA FLA WxHxD Weight Abbreviation Description


Equip Tag Sub Tag Model PS
A A A A mm kg CR Connection ratio
RXYTQ22UYF Tmp C Outdoor conditions in cooling
OU-AHU-01-A - RXYTQ12UYF 24 32 12.7 1,240 x 1,685 x 765 234 CC Available cooling capacity
VRV-AHU-01 400V
3Nph
OU-AHU-01-B - RXYTQ10UYF 22 25 9.3 1,240 x 1,685 x 765 234 Rq CC Required cooling capacity

RXYTQ30UYF Tmp H Outdoor conditions in heating (dry bulb temp. / RH)

OU-AHU-02-A - RXYTQ16UYF 31 40 19.3 1,240 x 1,685 x 765 283 HC Available heating capacity (integrated heating capacity)
VRV-AHU-02 400V
3Nph
OU-AHU-02-B - RXYTQ14UYF 27 32 15.8 1,240 x 1,685 x 765 283 Piping Largest distance from indoor unit to outdoor unit

RXYTQ26UYF PS Power supply (voltage and phases)

OU-AHU-03-A - RXYTQ14UYF 27 32 15.8 1,240 x 1,685 x 765 283 MCA Minimum Circuit Amps
VRV-AHU-03 400V
3Nph
OU-AHU-03-B - RXYTQ12UYF 24 32 12.7 1,240 x 1,685 x 765 234 MOP Maximum Overcurrent Protection

RXYTQ18UYF FLA Fan Motor Input

OU-AHU-04-A - RXYTQ10UYF 22 25 9.3 1,240 x 1,685 x 765 234 RLA Nominal Running Amps
VRV-AHU-04 400V
3Nph
OU-AHU-04-B - RXYTQ8UYF 16.1 20 8 930 x 1,685 x 765 198 WxHxD WidthxHeightxDepth

RXYTQ14UYF Weight Weight of the device


400V
VRV-AHU-05 OU-AHU-05-A - RXYTQ14UYF 3Nph 27 32 15.8 1,240 x 1,685 x 765 283

RXYTQ30UYF

OU-AHU-06-A - RXYTQ16UYF 31 40 19.3 1,240 x 1,685 x 765 283


VRV-AHU-06 400V
3Nph
OU-AHU-06-B - RXYTQ14UYF 27 32 15.8 1,240 x 1,685 x 765 283
VRV AHU INDOOR UNIT SCHEDULE
DX COOLING SUPPLY FAN Unit Dimensions
Supply Air
EQUIP EQUIPMENT EQUIPMENT UNIT Total Circuits Coil Volume Total Fan System Electrical N Current
S. No LOCATION SERVICE AREA TAG MODEL WEIGHT Capacity Coil Layers per Coil Medium Flow Rate Pressure Input Supply (A) W (MM) L (MM) H (MM)
(Kg) (Ton) (Pa) Power
(CFM)

380-
1 ROOF GR- LIVING & DINNING AHU-01 DM2TB-0710 523 15 1 13 R410A 4230 922.51 3.98 415V/3Ph 8.3 1450 2650 1230
/ 50Hz

GR-HALLWAY,LOBBY & 380-


2 ROOF AHU-02 DM2TB-0713 672.8 19 1 20 R410A 5500 916.29 4.75 415V/3Ph 8.3 1750 2850 1230
ENTRANCE
/ 50Hz

380-
3 ROOF GR-FORMAL MAJLIS & AHU-03 DM2TB-0710 519.6 17 1 13 R410A 4660 957.56 4.69 415V/3Ph 8.3 1450 2650 1230
DINNING / 50Hz

380-
1ST-HIS BEDROOM&
4 ROOF LOUNGE AHU-04 DM2TB-0413 550.4 13 1 12 R410A 3600 902.1 3.23 415V/3Ph 6.4 1750 2750 930
/ 50Hz

380-
5 ROOF 1ST-HER BEDROOM AHU-05 DM2TB-0410 429.8 8.5 1 8 R410A 2330 809.2 1.93 415V/3Ph 3.5 1450 2650 930
/ 50Hz

1ST-BAR,LIVING,SITTING 380-
6 ROOF & STAIR LOBBY AHU-06 DM2TB-0713 713.5 19.5 1 20 R410A 5720 915.28 4.87 415V/3Ph 11 1750 2850 1230
/ 50Hz