Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
*Supply Air Volume Flow 2.00 m³/s *Return Air Volume Flow 1.90 m³/s *Unit Type : DM2TB
Rate :
Rate : :Polyurethane-PU 40 kg/m³
*Insulation Mat. :Polyurethane-PU
*Inner Skin Thickness 0.5
::0.5 mm *Outer Skin Thickness : 0.8 mm *Delivery Mode : CBU
*Inner Skin Material GI
::GI *Outer Skin Material GI
::GI *Insulation Thickness:50
50 mm
*Inner Surface Painted : No *Outer Surface Painted : Yes Unit Orientation : Horizontal
*Painted Internal Metal No
::No :No
*SSTL Fastener at Frame :No Unit Height (Btm) : 1230 mm
*Painted Base Frame : No *Ceiling Hung Unit :No Unit Height (Top) : 0 mm
*Special Base Height : No *Rubber Cord at Frame No
::No Unit Width : 1450 mm
*All C-Channel Base : No Cross Section Air Velocity :1.41
1.41 m/s Unit Length : 2650 mm
Cross Section Air Velocity
*Floor Plate : No 0 m/s : 1050 x 1350 mm
Internal Dim. (HxW) :1050
(Upper) :
*Canopy : Yes Design outdoor
Internal Dim.
temperature 25.00 °C - mm
(HxW, Upper) :
:
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Application Type : Recirculation units or units with design inlet temperatures always > 9°C
CAL Class@ -400 Pa : L1 Ext.Leakage +ve. Pressure : 0.26 %
CAL Class@ +700 Pa : L2 Ext.Leakage -ve. Pressure : 0.04 %
ErP Identification Code : NRVU-UVU Internal Specific Fan Power : 4.84 W/(m³/s)
(SFPint)
Section No #1 #2 #3 #4 #5 #6 #7 #8
Depth mm 2650
Weight kg 523.0
Depth mm
Weight kg
*Frame Sliding
::Sliding Final Pressure Drop 123.71 Pa
Moisture resistant Beverage :Design Pressure
Casing Material :
*Quantity (24" x24 ") 2
: board Drop 82.47 Pa
:
*Quantity (12" x24 ") 2
: Non-woven cotton Synthetic Filter Energy Performance:-
Media :
*Spare Filter Qty (set) 0: Blend
*Model (15")Type
:DriPak 2000 80-85% (15")Type
:DriPak : Bag Filter Filter Face Velocity : 1.80 m/s
Initial or Clean
*Filter Media :Yes
Yes (Factory Supply) Grade/Class : F7 Pressure Drop : 56.72 Pa
*Frame Sliding
::Sliding Final Pressure Drop 156.72 Pa
:
Casing Material : Galvanized Steel Design Pressure
*Quantity (24" x24 ") 2
: Drop 106.72 Pa
:
*Quantity (12" x24 ") 2
: Filter Energy Performance:B
Media : Meltblown Synthetic
*Spare Filter Qty (set) 0:
2 EMPTY SECTION
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Drain Pan : No *Drain Pan Material : - Drain Pipe Location ::--
:-
*Top Opening (WxH) :- Opening(WxH):-
*Front Opening(WxH):- *Rear Opening(WxH):-
*Left Opening (WxH) : - Opening(WxH):-
*Right Opening(WxH):- No Panel
*Rear / Front Panel ::No
3 DX COOLING
4 SUPPLY FAN
Supply Air Volume 2.00 m³/s Brand : Yilida *Eff Type : IE1 (STD eff)
Flow Rate : *Model : SYQ315R *Brand : ALLIANCE/TEMA
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Altitude : 0.00 m Fan Size : 315 mm *Motor Output Power 4.00
: kW
Air Temperature : 20.00 °C Disch. Open (HxW) : 410x410 mm Frame Size : 112M-4
Air Density : 1.20 kg/m³ At Frequency : 50 Hz N Voltage : 400 V
Internal Static
319.42 Pa Max. Frequency : - Hz N Current : 8.3 A
Pressure :
External Static
500.00 Pa Total Efficiency : 68.7 % Efficiency : 84.2 %
Pressure :
Other Static
13.00 Pa Static Efficiency : 62.0 % Speed : 1430 RPM
Pressure :
Fan System Input
Velocity Pressure : 90.09 Pa 3.98 kW
Power :
*Total Pressure : 922.51 Pa Duct Velocity : 11.90 m/s Watt / CMH : 0.44
*VPT : No *Speed : 2738 RPM *Electrical Supply : 380-415V/3Ph/ 50Hz
*VFD : No *Shaft Diameter : 25 mm *Pole :4
*Shaft Power : 2.69 kW *Shaft Diameter : 28 mm
*Electrical Panel : Not Included
Shaft Power/mtr eff: 3.19 kW *Space Heater : No
*Standby Motor With Specific Fan Power (SFP) : 1.60 kW/(m³/s) *Thermistor : Yes
No
Heater :
# Design based on wet condition.
# The fan system effect is taken into account in the fan performance.
Sound
Sound Power 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Total (dBA)
In-duct Outdoor Air (Lw) dB 93 86 81 93 84 83 79 72 95
In-duct Supply Air (Lw) dB 95 96 94 99 88 87 81 74 99
Casing Sound Power Level (LwA) dB N/A 83 79 85 74 74 55 37 83
# The airborne total (dBA) is calculated for range 125Hz till 8kHz
DOOR LOCATION
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
ACCESSORIES
SPECIAL REMARK
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
*Supply Air Volume Flow 2.60 m³/s *Return Air Volume Flow 2.47 m³/s *Unit Type : DM2TB
Rate :
Rate : :Polyurethane-PU 40 kg/m³
*Insulation Mat. :Polyurethane-PU
*Inner Skin Thickness 0.5
::0.5 mm *Outer Skin Thickness : 0.8 mm *Delivery Mode : CBU
*Inner Skin Material GI
::GI *Outer Skin Material GI
::GI *Insulation Thickness:50
50 mm
*Inner Surface Painted : No *Outer Surface Painted : Yes Unit Orientation : Horizontal
*Painted Internal Metal No
::No :No
*SSTL Fastener at Frame :No Unit Height (Btm) : 1230 mm
*Painted Base Frame : No *Ceiling Hung Unit :No Unit Height (Top) : 0 mm
*Special Base Height : No *Rubber Cord at Frame No
::No Unit Width : 1750 mm
*All C-Channel Base : No Cross Section Air Velocity :1.5
1.5 m/s Unit Length : 2850 mm
Cross Section Air Velocity
*Floor Plate : No 0 m/s : 1050 x 1650 mm
Internal Dim. (HxW) :1050
(Upper) :
*Canopy : Yes Design outdoor
Internal Dim.
temperature 25.00 °C - mm
(HxW, Upper) :
:
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Application Type : Recirculation units or units with design inlet temperatures always > 9°C
CAL Class@ -400 Pa : L1 Ext.Leakage +ve. Pressure : 0.24 %
CAL Class@ +700 Pa : L2 Ext.Leakage -ve. Pressure : 0.04 %
ErP Identification Code : NRVU-UVU Internal Specific Fan Power : 4.78 W/(m³/s)
(SFPint)
Section No #1 #2 #3 #4 #5 #6 #7 #8
Depth mm 2850
Weight kg 672.8
Depth mm
Weight kg
*Frame Sliding
::Sliding Final Pressure Drop 141.22 Pa
Moisture resistant Beverage :Design Pressure
Casing Material :
*Quantity (24" x24 ") 2
: board Drop 94.14 Pa
:
*Quantity (12" x24 ") 3
: Non-woven cotton Synthetic Filter Energy Performance:-
Media :
*Spare Filter Qty (set) 0: Blend
*Model (15")Type
:DriPak 2000 80-85% (15")Type
:DriPak : Bag Filter Filter Face Velocity : 2.00 m/s
Initial or Clean
*Filter Media :Yes
Yes (Factory Supply) Grade/Class : F7 Pressure Drop : 63.18 Pa
*Frame Sliding
::Sliding Final Pressure Drop 163.18 Pa
:
Casing Material : Galvanized Steel Design Pressure
*Quantity (24" x24 ") 2
: Drop 113.18 Pa
:
*Quantity (12" x24 ") 3
: Filter Energy Performance:B
Media : Meltblown Synthetic
*Spare Filter Qty (set) 0:
2 EMPTY SECTION
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Drain Pan : No *Drain Pan Material : - Drain Pipe Location ::--
:-
*Top Opening (WxH) :- Opening(WxH):-
*Front Opening(WxH):- *Rear Opening(WxH):-
*Left Opening (WxH) : - Opening(WxH):-
*Right Opening(WxH):- No Panel
*Rear / Front Panel ::No
3 DX COOLING
4 SUPPLY FAN
Supply Air Volume 2.60 m³/s Brand : Yilida *Eff Type : IE1 (STD eff)
Flow Rate : *Model : SYQ400R *Brand : ALLIANCE/TEMA
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Altitude : 0.00 m Fan Size : 400 mm *Motor Output Power 4.00
: kW
Air Temperature : 20.00 °C Disch. Open (HxW) : 515x515 mm Frame Size : 112M-4
Air Density : 1.20 kg/m³ At Frequency : 50 Hz N Voltage : 400 V
Internal Static
342.90 Pa Max. Frequency : - Hz N Current : 8.3 A
Pressure :
External Static
500.00 Pa Total Efficiency : 74.3 % Efficiency : 84.2 %
Pressure :
Other Static
12.00 Pa Static Efficiency : 69.3 % Speed : 1430 RPM
Pressure :
Fan System Input
Velocity Pressure : 61.39 Pa 4.75 kW
Power :
*Total Pressure : 916.29 Pa Duct Velocity : 9.80 m/s Watt / CMH : 0.41
*VPT : No *Speed : 1974 RPM *Electrical Supply : 380-415V/3Ph/ 50Hz
*VFD : No *Shaft Diameter : 30 mm *Pole :4
*Shaft Power : 3.21 kW *Shaft Diameter : 28 mm
*Electrical Panel : Not Included
Shaft Power/mtr eff: 3.81 kW *Space Heater : No
*Standby Motor With Specific Fan Power (SFP) : 1.47 kW/(m³/s) *Thermistor : Yes
No
Heater :
# Design based on wet condition.
# The fan system effect is taken into account in the fan performance.
Sound
Sound Power 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Total (dBA)
In-duct Outdoor Air (Lw) dB 84 83 80 92 85 82 77 71 92
In-duct Supply Air (Lw) dB 85 91 84 98 88 85 78 72 97
Casing Sound Power Level (LwA) dB N/A 77 70 84 74 72 53 35 82
# The airborne total (dBA) is calculated for range 125Hz till 8kHz
DOOR LOCATION
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
ACCESSORIES
SPECIAL REMARK
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
*Supply Air Volume Flow 2.20 m³/s *Return Air Volume Flow 2.09 m³/s *Unit Type : DM2TB
Rate :
Rate : :Polyurethane-PU 40 kg/m³
*Insulation Mat. :Polyurethane-PU
*Inner Skin Thickness 0.5
::0.5 mm *Outer Skin Thickness : 0.8 mm *Delivery Mode : CBU
*Inner Skin Material GI
::GI *Outer Skin Material GI
::GI *Insulation Thickness:50
50 mm
*Inner Surface Painted : No *Outer Surface Painted : Yes Unit Orientation : Horizontal
*Painted Internal Metal No
::No :No
*SSTL Fastener at Frame :No Unit Height (Btm) : 1230 mm
*Painted Base Frame : No *Ceiling Hung Unit :No Unit Height (Top) : 0 mm
*Special Base Height : No *Rubber Cord at Frame No
::No Unit Width : 1450 mm
*All C-Channel Base : No Cross Section Air Velocity :1.55
1.55 m/s Unit Length : 2650 mm
Cross Section Air Velocity
*Floor Plate : No 0 m/s : 1050 x 1350 mm
Internal Dim. (HxW) :1050
(Upper) :
*Canopy : Yes Design outdoor
Internal Dim.
temperature 25.00 °C - mm
(HxW, Upper) :
:
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Application Type : Recirculation units or units with design inlet temperatures always > 9°C
CAL Class@ -400 Pa : L1 Ext.Leakage +ve. Pressure : 0.24 %
CAL Class@ +700 Pa : L2 Ext.Leakage -ve. Pressure : 0.04 %
ErP Identification Code : NRVU-UVU Internal Specific Fan Power : 5.23 W/(m³/s)
(SFPint)
Section No #1 #2 #3 #4 #5 #6 #7 #8
Depth mm 2650
Weight kg 519.6
Depth mm
Weight kg
*Frame Sliding
::Sliding Final Pressure Drop 139.53 Pa
Moisture resistant Beverage :Design Pressure
Casing Material :
*Quantity (24" x24 ") 2
: board Drop 93.02 Pa
:
*Quantity (12" x24 ") 2
: Non-woven cotton Synthetic Filter Energy Performance:-
Media :
*Spare Filter Qty (set) 0: Blend
*Model (15")Type
:DriPak 2000 80-85% (15")Type
:DriPak : Bag Filter Filter Face Velocity : 1.98 m/s
Initial or Clean
*Filter Media :Yes
Yes (Factory Supply) Grade/Class : F7 Pressure Drop : 62.56 Pa
*Frame Sliding
::Sliding Final Pressure Drop 162.56 Pa
:
Casing Material : Galvanized Steel Design Pressure
*Quantity (24" x24 ") 2
: Drop 112.56 Pa
:
*Quantity (12" x24 ") 2
: Filter Energy Performance:B
Media : Meltblown Synthetic
*Spare Filter Qty (set) 0:
2 EMPTY SECTION
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Drain Pan : No *Drain Pan Material : - Drain Pipe Location ::--
:-
*Top Opening (WxH) :- Opening(WxH):-
*Front Opening(WxH):- *Rear Opening(WxH):-
*Left Opening (WxH) : - Opening(WxH):-
*Right Opening(WxH):- No Panel
*Rear / Front Panel ::No
3 DX COOLING
4 SUPPLY FAN
Supply Air Volume 2.20 m³/s Brand : Yilida *Eff Type : IE1 (STD eff)
Flow Rate : *Model : SYQ315R *Brand : ALLIANCE/TEMA
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Altitude : 0.00 m Fan Size : 315 mm *Motor Output Power 4.00
: kW
Air Temperature : 20.00 °C Disch. Open (HxW) : 410x410 mm Frame Size : 112M-4
Air Density : 1.20 kg/m³ At Frequency : 50 Hz N Voltage : 400 V
Internal Static
335.55 Pa Max. Frequency : - Hz N Current : 8.3 A
Pressure :
External Static
500.00 Pa Total Efficiency : 66.6 % Efficiency : 84.2 %
Pressure :
Other Static
13.00 Pa Static Efficiency : 59.1 % Speed : 1430 RPM
Pressure :
Fan System Input
Velocity Pressure : 109.01 Pa 4.69 kW
Power :
*Total Pressure : 957.56 Pa Duct Velocity : 13.09 m/s Watt / CMH : 0.47
*VPT : No *Speed : 2886 RPM *Electrical Supply : 380-415V/3Ph/ 50Hz
*VFD : No *Shaft Diameter : 25 mm *Pole :4
*Shaft Power : 3.16 kW *Shaft Diameter : 28 mm
*Electrical Panel : Not Included
Shaft Power/mtr eff: 3.75 kW *Space Heater : No
*Standby Motor With Specific Fan Power (SFP) : 1.71 kW/(m³/s) *Thermistor : Yes
No
Heater :
# Design based on wet condition.
# The fan system effect is taken into account in the fan performance.
Sound
Sound Power 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Total (dBA)
In-duct Outdoor Air (Lw) dB 94 87 83 94 86 85 81 74 97
In-duct Supply Air (Lw) dB 96 97 96 100 91 89 83 76 101
Casing Sound Power Level (LwA) dB N/A 84 81 86 76 76 58 39 85
# The airborne total (dBA) is calculated for range 125Hz till 8kHz
DOOR LOCATION
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
ACCESSORIES
SPECIAL REMARK
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
*Supply Air Volume Flow 1.70 m³/s *Return Air Volume Flow 1.62 m³/s *Unit Type : DM2TB
Rate :
Rate : :Polyurethane-PU 40 kg/m³
*Insulation Mat. :Polyurethane-PU
*Inner Skin Thickness 0.5
::0.5 mm *Outer Skin Thickness : 0.8 mm *Delivery Mode : CBU
*Inner Skin Material GI
::GI *Outer Skin Material GI
::GI *Insulation Thickness:50
50 mm
*Inner Surface Painted : No *Outer Surface Painted : Yes Unit Orientation : Horizontal
*Painted Internal Metal No
::No :No
*SSTL Fastener at Frame :No Unit Height (Btm) : 930 mm
*Painted Base Frame : No *Ceiling Hung Unit :No Unit Height (Top) : 0 mm
*Special Base Height : No *Rubber Cord at Frame No
::No Unit Width : 1750 mm
*All C-Channel Base : No Cross Section Air Velocity :1.37
1.37 m/s Unit Length : 2750 mm
Cross Section Air Velocity
*Floor Plate : No 0 m/s : 750 x 1650
Internal Dim. (HxW) :750 mm
(Upper) :
*Canopy : Yes Design outdoor
Internal Dim.
temperature 25.00 °C - mm
(HxW, Upper) :
:
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Application Type : Recirculation units or units with design inlet temperatures always > 9°C
CAL Class@ -400 Pa : L1 Ext.Leakage +ve. Pressure : 0.31 %
CAL Class@ +700 Pa : L2 Ext.Leakage -ve. Pressure : 0.05 %
ErP Identification Code : NRVU-UVU Internal Specific Fan Power : 4.69 W/(m³/s)
(SFPint)
Section No #1 #2 #3 #4 #5 #6 #7 #8
Depth mm 2750
Weight kg 550.4
Depth mm
Weight kg
*Frame Sliding
::Sliding Final Pressure Drop 125.89 Pa
Moisture resistant Beverage :Design Pressure
Casing Material :
*Quantity (24" x24 ") 2
: board Drop 83.93 Pa
:
*Quantity (12" x24 ") 1
: Non-woven cotton Synthetic Filter Energy Performance:-
Media :
*Spare Filter Qty (set) 0: Blend
*Model (15")Type
:DriPak 2000 80-85% (15")Type
:DriPak : Bag Filter Filter Face Velocity : 1.83 m/s
Initial or Clean
*Filter Media :Yes
Yes (Factory Supply) Grade/Class : F7 Pressure Drop : 57.53 Pa
*Frame Sliding
::Sliding Final Pressure Drop 157.53 Pa
:
Casing Material : Galvanized Steel Design Pressure
*Quantity (24" x24 ") 2
: Drop 107.53 Pa
:
*Quantity (12" x24 ") 1
: Filter Energy Performance:B
Media : Meltblown Synthetic
*Spare Filter Qty (set) 0:
2 EMPTY SECTION
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Drain Pan : No *Drain Pan Material : - Drain Pipe Location ::--
:-
*Top Opening (WxH) :- Opening(WxH):-
*Front Opening(WxH):- *Rear Opening(WxH):-
*Left Opening (WxH) : - Opening(WxH):-
*Right Opening(WxH):- No Panel
*Rear / Front Panel ::No
3 DX COOLING
4 SUPPLY FAN
Supply Air Volume 1.70 m³/s Brand : Yilida *Eff Type : IE1 (STD eff)
Flow Rate : *Model : SYQ315R *Brand : ALLIANCE/TEMA
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Altitude : 0.00 m Fan Size : 315 mm *Motor Output Power 3.00
: kW
Air Temperature : 20.00 °C Disch. Open (HxW) : 410x410 mm Frame Size : 100L2-4
Air Density : 1.20 kg/m³ At Frequency : 50 Hz N Voltage : 400 V
Internal Static
333.01 Pa Max. Frequency : - Hz N Current : 6.4 A
Pressure :
External Static
500.00 Pa Total Efficiency : 71.8 % Efficiency : 82.6 %
Pressure :
Other Static
4.00 Pa Static Efficiency : 66.6 % Speed : 1410 RPM
Pressure :
Fan System Input
Velocity Pressure : 65.09 Pa 3.23 kW
Power :
*Total Pressure : 902.10 Pa Duct Velocity : 10.11 m/s Watt / CMH : 0.42
*VPT : No *Speed : 2553 RPM *Electrical Supply : 380-415V/3Ph/ 50Hz
*VFD : No *Shaft Diameter : 25 mm *Pole :4
*Shaft Power : 2.14 kW *Shaft Diameter : 28 mm
*Electrical Panel : Not Included
Shaft Power/mtr eff: 2.59 kW *Space Heater : No
*Standby Motor With Specific Fan Power (SFP) : 1.52 kW/(m³/s) *Thermistor : Yes
No
Heater :
# Design based on wet condition.
# The fan system effect is taken into account in the fan performance.
Sound
Sound Power 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Total (dBA)
In-duct Outdoor Air (Lw) dB 89 83 78 89 81 80 77 69 92
In-duct Supply Air (Lw) dB 91 92 93 95 86 84 78 71 96
Casing Sound Power Level (LwA) dB N/A 78 78 81 71 71 53 34 80
# The airborne total (dBA) is calculated for range 125Hz till 8kHz
DOOR LOCATION
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
ACCESSORIES
SPECIAL REMARK
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
*Supply Air Volume Flow 1.10 m³/s *Return Air Volume Flow 1.05 m³/s *Unit Type : DM2TB
Rate :
Rate : :Polyurethane-PU 40 kg/m³
*Insulation Mat. :Polyurethane-PU
*Inner Skin Thickness 0.5
::0.5 mm *Outer Skin Thickness : 0.8 mm *Delivery Mode : CBU
*Inner Skin Material GI
::GI *Outer Skin Material GI
::GI *Insulation Thickness:50
50 mm
*Inner Surface Painted : No *Outer Surface Painted : Yes Unit Orientation : Horizontal
*Painted Internal Metal No
::No :No
*SSTL Fastener at Frame :No Unit Height (Btm) : 930 mm
*Painted Base Frame : No *Ceiling Hung Unit :No Unit Height (Top) : 0 mm
*Special Base Height : No *Rubber Cord at Frame No
::No Unit Width : 1450 mm
*All C-Channel Base : No Cross Section Air Velocity :1.09
1.09 m/s Unit Length : 2650 mm
Cross Section Air Velocity
*Floor Plate : No 0 m/s : 750 x 1350
Internal Dim. (HxW) :750 mm
(Upper) :
*Canopy : Yes Design outdoor
Internal Dim.
temperature 25.00 °C - mm
(HxW, Upper) :
:
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Application Type : Recirculation units or units with design inlet temperatures always > 9°C
CAL Class@ -400 Pa : L1 Ext.Leakage +ve. Pressure : 0.41 %
CAL Class@ +700 Pa : L2 Ext.Leakage -ve. Pressure : 0.07 %
ErP Identification Code : NRVU-UVU Internal Specific Fan Power : 3.85 W/(m³/s)
(SFPint)
Section No #1 #2 #3 #4 #5 #6 #7 #8
Depth mm 2650
Weight kg 429.8
Depth mm
Weight kg
*Frame Sliding
::Sliding Final Pressure Drop 100.22 Pa
Moisture resistant Beverage :Design Pressure
Casing Material :
*Quantity (24" x24 ") 2
: board Drop 66.81 Pa
:
*Quantity (12" x24 ") 0
: Non-woven cotton Synthetic Filter Energy Performance:-
Media :
*Spare Filter Qty (set) 0: Blend
*Model (15")Type
:DriPak 2000 80-85% (15")Type
:DriPak : Bag Filter Filter Face Velocity : 1.49 m/s
Initial or Clean
*Filter Media :Yes
Yes (Factory Supply) Grade/Class : F7 Pressure Drop : 47.78 Pa
*Frame Sliding
::Sliding Final Pressure Drop 143.33 Pa
:
Casing Material : Galvanized Steel Design Pressure
*Quantity (24" x24 ") 2
: Drop 95.56 Pa
:
*Quantity (12" x24 ") 0
: Filter Energy Performance:B
Media : Meltblown Synthetic
*Spare Filter Qty (set) 0:
2 EMPTY SECTION
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Drain Pan : No *Drain Pan Material : - Drain Pipe Location ::--
:-
*Top Opening (WxH) :- Opening(WxH):-
*Front Opening(WxH):- *Rear Opening(WxH):-
*Left Opening (WxH) : - Opening(WxH):-
*Right Opening(WxH):- No Panel
*Rear / Front Panel ::No
3 DX COOLING
4 SUPPLY FAN
Supply Air Volume 1.10 m³/s Brand : Yilida *Eff Type : IE1 (STD eff)
Flow Rate : *Model : SYQ315R *Brand : ALLIANCE/TEMA
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Altitude : 0.00 m Fan Size : 315 mm *Motor Output Power 1.50
: kW
Air Temperature : 20.00 °C Disch. Open (HxW) : 410x410 mm Frame Size : 90L-4
Air Density : 1.20 kg/m³ At Frequency : 50 Hz N Voltage : 400 V
Internal Static
251.95 Pa Max. Frequency : - Hz N Current : 3.5 A
Pressure :
External Static
500.00 Pa Total Efficiency : 73.3 % Efficiency : 78.5 %
Pressure :
Other Static
30.00 Pa Static Efficiency : 70.9 % Speed : 1390 RPM
Pressure :
Fan System Input
Velocity Pressure : 27.25 Pa 1.93 kW
Power :
*Total Pressure : 809.20 Pa Duct Velocity : 6.54 m/s Watt / CMH : 0.39
*VPT : No *Speed : 2224 RPM *Electrical Supply : 380-415V/3Ph/ 50Hz
*VFD : No *Shaft Diameter : 25 mm *Pole :4
*Shaft Power : 1.21 kW *Shaft Diameter : 24 mm
*Electrical Panel : Not Included
Shaft Power/mtr eff: 1.54 kW *Space Heater : No
*Standby Motor With Specific Fan Power (SFP) : 1.40 kW/(m³/s) *Thermistor : Yes
No
Heater :
# Design based on wet condition.
# The fan system effect is taken into account in the fan performance.
Sound
Sound Power 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Total (dBA)
In-duct Outdoor Air (Lw) dB 86 78 73 86 75 74 70 64 88
In-duct Supply Air (Lw) dB 88 86 86 90 79 78 72 66 92
Casing Sound Power Level (LwA) dB N/A 73 71 77 65 65 46 29 75
# The airborne total (dBA) is calculated for range 125Hz till 8kHz
DOOR LOCATION
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
ACCESSORIES
SPECIAL REMARK
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
*Supply Air Volume Flow 2.70 m³/s *Return Air Volume Flow 2.57 m³/s *Unit Type : DM2TB
Rate :
Rate : :Polyurethane-PU 40 kg/m³
*Insulation Mat. :Polyurethane-PU
*Inner Skin Thickness 0.5
::0.5 mm *Outer Skin Thickness : 0.8 mm *Delivery Mode : CBU
*Inner Skin Material GI
::GI *Outer Skin Material GI
::GI *Insulation Thickness:50
50 mm
*Inner Surface Painted : No *Outer Surface Painted : Yes Unit Orientation : Horizontal
*Painted Internal Metal No
::No :No
*SSTL Fastener at Frame :No Unit Height (Btm) : 1230 mm
*Painted Base Frame : No *Ceiling Hung Unit :No Unit Height (Top) : 0 mm
*Special Base Height : No *Rubber Cord at Frame No
::No Unit Width : 1750 mm
*All C-Channel Base : No Cross Section Air Velocity :1.56
1.56 m/s Unit Length : 2850 mm
Cross Section Air Velocity
*Floor Plate : No 0 m/s : 1050 x 1650 mm
Internal Dim. (HxW) :1050
(Upper) :
*Canopy : Yes Design outdoor
Internal Dim.
temperature 25.00 °C - mm
(HxW, Upper) :
:
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Application Type : Recirculation units or units with design inlet temperatures always > 9°C
CAL Class@ -400 Pa : L1 Ext.Leakage +ve. Pressure : 0.23 %
CAL Class@ +700 Pa : L2 Ext.Leakage -ve. Pressure : 0.04 %
ErP Identification Code : NRVU-UVU Internal Specific Fan Power : 4.73 W/(m³/s)
(SFPint)
Section No #1 #2 #3 #4 #5 #6 #7 #8
Depth mm 2850
Weight kg 713.5
Depth mm
Weight kg
*Frame Sliding
::Sliding Final Pressure Drop 148.66 Pa
Moisture resistant Beverage :Design Pressure
Casing Material :
*Quantity (24" x24 ") 2
: board Drop 99.11 Pa
:
*Quantity (12" x24 ") 3
: Non-woven cotton Synthetic Filter Energy Performance:-
Media :
*Spare Filter Qty (set) 0: Blend
*Model (15")Type
:DriPak 2000 80-85% (15")Type
:DriPak : Bag Filter Filter Face Velocity : 2.08 m/s
Initial or Clean
*Filter Media :Yes
Yes (Factory Supply) Grade/Class : F7 Pressure Drop : 65.88 Pa
*Frame Sliding
::Sliding Final Pressure Drop 165.88 Pa
:
Casing Material : Galvanized Steel Design Pressure
*Quantity (24" x24 ") 2
: Drop 115.88 Pa
:
*Quantity (12" x24 ") 3
: Filter Energy Performance:B
Media : Meltblown Synthetic
*Spare Filter Qty (set) 0:
2 EMPTY SECTION
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Drain Pan : No *Drain Pan Material : - Drain Pipe Location ::--
:-
*Top Opening (WxH) :- Opening(WxH):-
*Front Opening(WxH):- *Rear Opening(WxH):-
*Left Opening (WxH) : - Opening(WxH):-
*Right Opening(WxH):- No Panel
*Rear / Front Panel ::No
3 DX COOLING
4 SUPPLY FAN
Supply Air Volume 2.70 m³/s Brand : Yilida *Eff Type : IE1 (STD eff)
Flow Rate : *Model : SYQ400R *Brand : ALLIANCE/TEMA
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
Altitude : 0.00 m Fan Size : 400 mm *Motor Output Power 5.50
: kW
Air Temperature : 20.00 °C Disch. Open (HxW) : 515x515 mm Frame Size : 132S-4
Air Density : 1.20 kg/m³ At Frequency : 50 Hz N Voltage : 400 V
Internal Static
337.08 Pa Max. Frequency : - Hz N Current : 11 A
Pressure :
External Static
500.00 Pa Total Efficiency : 73.8 % Efficiency : 85.7 %
Pressure :
Other Static
12.00 Pa Static Efficiency : 68.5 % Speed : 1440 RPM
Pressure :
Fan System Input
Velocity Pressure : 66.20 Pa 4.87 kW
Power :
*Total Pressure : 915.28 Pa Duct Velocity : 10.18 m/s Watt / CMH : 0.4
*VPT : No *Speed : 1997 RPM *Electrical Supply : 380-415V/3Ph/ 50Hz
*VFD : No *Shaft Diameter : 30 mm *Pole :4
*Shaft Power : 3.35 kW *Shaft Diameter : 38 mm
*Electrical Panel : Not Included
Shaft Power/mtr eff: 3.91 kW *Space Heater : No
*Standby Motor With Specific Fan Power (SFP) : 1.45 kW/(m³/s) *Thermistor : Yes
No
Heater :
# Design based on wet condition.
# The fan system effect is taken into account in the fan performance.
Sound
Sound Power 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz Total (dBA)
In-duct Outdoor Air (Lw) dB 84 83 81 93 85 83 77 71 93
In-duct Supply Air (Lw) dB 86 91 84 98 89 86 79 72 97
Casing Sound Power Level (LwA) dB N/A 78 71 84 75 73 53 36 83
# The airborne total (dBA) is calculated for range 125Hz till 8kHz
DOOR LOCATION
Database Version : 4.3.20190228 AHU Version : 4.3 Patch 26 Pricing Version : 4.3.20190325
Daikin Refrigeration Malaysia Sdn. Bhd is participating in the EUROVENT CERTIFICATION Programme for Air Handling Units. The range DM2 and DM2TB is certified under the
number 09.11.441 and presented on www.eurovent-certification.com.
AHU specified in this report are manufactured by Daikin Refrigeration Malaysia Sdn. Bhd.
Customer :
ACCESSORIES
SPECIAL REMARK