Recommendation of Genuine Filter & Lubricants: Lubricant

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

PT HEXINDO ADIPERKASA Tbk

Technical Support

RECOMMENDATION OF GENUINE FILTER & LUBRICANTS

Model : ZX470LC-5G
LUBRICANT
Interval of Periodic Service ( liter )
COMPONENT PART NUMBER DESCRIPTION 250 500 1000 1500 2000 2500 3000 4000

1 Engine HTCDH1 Hitachi Diesel Engine Oil DH-1 15W40 0 55 55 55 55 55 55 55


2 Hydraulic HTC46TP Hitachi Hydraulic Oil 46HN 0 0 0 0 0 0 0 510
3 Pump Transmission HTCDH1 Hitachi Diesel Engine Oil DH-1 15W40 0 0 0 0 0 0 0 0
4 Swing Reduction Gear HTCGL490 Hitachi Gear Oil GL-4 90 0 0 13 0 13 0 13 13
5 Travell Reduction Gear HTCGL490 Hitachi Gear Oil GL-4 90 0 0 0 0 22 0 0 22
6 Coolant V74-15023 Hitachi long life Coolant 0 0 0 0 0 0 0 61
7 Grease Swing Internal Gear ( ** ) ( *** ) HTCEPNO2P Hitachi Grease EP No.2 See NOTES
8 Grease Front Joint Pins ( * ) HTCEPNO2P Hitachi Grease EP No.2 Sufficiently

Number of Engine Oil 0 55 55 55 55 55 55 55


Number of Hydraulic Oil 0 0 0 0 0 0 0 510
Number of Gear Ol 0 0 13 0 35 0 13 35
Number of Coolant 0 0 0 0 0 0 0 61
Number of Grease Sufficiently

NOTES:
- Maintenance interval stated above when machine operated using B20
-(*) Maintenance required when operating in water or mud and under extreamly severe condition.
- ( ** ) Maintenance required only during first time check.
- ( *** ) Check and add grease.
- Change travel reduction gear oil every 1000h if travel ratio more than 20%.
- Change hydraulic oil will be shorter if use Hydraulic breaker as attachment, refer to maintenance manual book.
- Change coolant twice a year if not use Hitachi long life coolant.

FILTER
Interval of Periodic Service ( Pcs )
COMPONENT Part Number 250 500 1000 1500 2000 2500 3000 4000

1 Engine Oil Filter 4658521 0 2 2 2 2 2 2 2


2 Primary Fuel Filter 4616864 1 1 1 1 1 1 1 1
3 Secondary Fuel Filter 4616544 2 2 2 2 2 2 2 2
4 Air Cleaner Element outer 4466269 Replace after 6 times cleaned / 1 year
5 Air Cleaner Element inner 4466268 Replace when Outer Element replaced
6 AC Filter Out side 4632689 / YA00032683 0 0 1 0 1 0 1 1
7 AC Filter In Side YA00001490 0 0 1 0 1 0 1 1
8 Hydraulic Return Filter 4654745 0 0 1 0 1 0 1 1
9 Hydraulic Pilot Filter 4630525 0 0 1 0 1 0 1 1
10 Drain Filter 4363399 0 0 1 0 1 0 1 1
11 Air Breather Element 4437838 0 0 0 0 0 0 0 1
12 Hydraulic Suction Strainer 4317008 Cleaned up

Number of Filter 3 5 12 5 12 5 12 13

IMPORTANT !
> The maintenance guide table is affixed to the reverse side of the tool box cover.
> Always use recommended Fuels and Lubricants.
> Drain fuel sump every day in the morning before start the machine
> Failure to do so will result in machine damage and loss of Hitachi Products Warranty.
> The Turbocharge may be damage if the engine is not proprly shut down.
> Grease bucket and link pivots every day until break-in operation (50 hours) is complete.
> When any bucket others than the one with adjustment devices provided exclusively for Zaxis series is used, grease the two bucket connecting pin every 250 hrs.

Jun-19