Hindustan Urvarak and Rasayan Limited

Barauni & Sindri

PROJECT REFERENCE
Originator
Project N° Unit Number Doc. Type Material Code Serial Number Revision Page
TP 077625 C41 DW 1514 0001 C Page 1 of 6
Cause and Effect Diagram - GTG-HRSG

Cause and Effect Diagram

GTG-HRSG

प्रोजेक एण् डेवलपम� ट इं�डया �ल�मटेड नोएडा


PROJECTS & DEVELOPMENT INDIA LTD. NOIDA DOCUMENT CATEGORY
Ref. / Order No. (संदभर/ आदे श संख्य)
INFORMATION – Class 1
CHECKED BY (जाँचकतार)
REVIEW – Class 2
REVIEWED : CODE-1 ( समीक्: कोड -1) ISSUED FOR
√ ( No Comments)
REVIEWED : CODE-2 ( समीक्: कोड -2) OWNER
(Accepted as Marked)
20.12.19
REVIEWED : CODE-3 ( समीक्: कोड -3)
INTERNAL - CONSORTIUM
( Not Accepted / New Drg. Reqd.)
INTERNAL - TECHNIPFMC
यह अनुमोदन आपू�तकतार / ठे केदार को उनके अनुबंध संबंधी दाियत्व/िजम्मेदा�रय से मु� नह� करता
है| INTERNAL - LTHE
This Approval does not absolve the Supplier / Contractor of their contractual
obligations / responsibilities

Any change shall be submitted for review.

Venkatesh.k P.O JAYAKUMAR.R S.Rajan


2019.11.20 15:14:57 +05'30' 2019.11.20 15:23:12 +05'30'
2019.11.20 14:59:41 +05'30'

C 20/11/19 IFD - ISSUED FOR DESIGN VENKATESH K JAYAKUMAR.R S.RAJAN


B 27/03/19 IFD - ISSUED FOR DESIGN UDU S. DURAIKANNU S.RAJAN
A 17/12/18 IFR - ISSUED FOR REVIEW PJA S. DURAIKANNU S. CIMAOMO
Date WRITTEN BY CHECKED BY APPROVED BY
Rev Revision Description
DD/MM/YY (name & visa) (name & visa) (name & visa)
DOCUMENT REVISIONS
CONFIDENTIAL INFORMATION – The information contained in this document belongs to TECHNIP. All IP rights relevant to this document are expressly reserved.
Hindustan Urvarak and Rasayan Limited

Barauni & Sindri

PROJECT REFERENCE
Originator
Project N° Unit Number Doc. Type Material Code Serial Number Revision Page
TP 077625 C41 DW 1514 0001 C Page 2 of 6
Cause and Effect Diagram - GTG-HRSG

HOLDs
HOLD n° REF. § DESCRIPTION
1
2

Sheet IS No. Description

3 01 Gas Turbine Shutdown


4 02 Gas Turbine Shutdown

5 03 HRSG Shutdown
6 04 HRSG Shutdown

CONFIDENTIAL INFORMATION – The information contains in this document belongs to TECHNIP. All IP rights relevant to this document are expressly reserved.
NOTE REV
CAUSE AND EFFECT CHART ABBREVIATIONS USED IN THE MATRIX :
A = Activate

1
UNIT or EQUIPMENT LOGIC IDENTIFICATION C= Close
O = Open

0001

0001
PID
S = Start
T = Trip
I = Inhibit
P = Permissive
R = Reset
V = oVerride

EFFECT
IS-01 Gas Turbine Shutdown

DESCRIPTION
SERVICE

Power Generation Package

Power Generation Package


NOTES :
1. Except otherwise indicated, all PIDs number
start by 077625-B41-PID-0021 for Barauni and
by 077625-S41-PID-0021 for Sindri.
2.Cause and Effect for the GTG-HRSG unit will
be further developed according to vendor
recommendations, if required.
3. For package equipments refer vendor Cause
and Effect Diagrams.

TAG No
4. GTG Emergency Shutdown

1 B41-PK-0001

4 B41-PK-0001
5. GTG Normal Shutdown
CAUSE
SERVICE PID OVERRIDE
REV NOTE TAG No.

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30
DESCRIPTION TAG No

9
C Deleted 1 1
2 2
3 3
4 4
5 5
1,4 GTG Emergency Conditions 0001 B41-HS-0501 6 T 6
7 7
8 8
9 9
10 10
1,5 MP Fuel Gas Temperature Low Low B45-IS-05 11 T 11
12 12
13 13
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
23 23
24 24
25 25
26 26
27 27
28 28
29 29
30 30
RESET
1 1
2 2
3 3
4 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 30

CAUSE AND EFFECT DIAGRAM Activity Unit Doc Type Mat. code Serial N° Page Rev.
077625 C41 DW 1514 0001 3 C

CONFIDENTIAL INFORMATION – The information contained in this document belongs to TECHNIP. All IP rights relevant to this document are expressly reserved.
NOTE REV
CAUSE AND EFFECT CHART ABBREVIATIONS USED IN THE MATRIX :
A = Activate

1
UNIT or EQUIPMENT LOGIC IDENTIFICATION C= Close
O = Open

0002
PID
S = Start
T = Trip
I = Inhibit
P = Permissive
R = Reset
V = oVerride

EFFECT
IS-02 HRSG Shutdown

Heat Recovery Steam Generator


DESCRIPTION
SERVICE
NOTES :
1 Except otherwise indicated, all PIDs number
start by 077625-B41-PID-0021 for Barauni and
by 077625-S41-PID-0021 for Sindri.
2.Cause and Effect for the GTG-HRSG unit will
be further developed according to vendor
recommendations, if required.
3. For package equipments refer vendor Cause
and Effect Diagrams.

TAG No

1 B41-H-0001
CAUSE
SERVICE PID OVERRIDE
REV NOTE TAG No.

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30
DESCRIPTION TAG No

9
C Deleted 1 1
2 2
3 3
4 4
5 5
1 HRSG Emergency Conditions 0002 B41-HS-0601 6 T 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
23 23
24 24
25 25
26 26
27 27
28 28
29 29
30 30
RESET
1 1
2 2
3 3
4 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 30

CAUSE AND EFFECT Activity Unit Doc Type Mat. code Serial N° Page Rev.
007625 C41 DW 1514 0001 4 C

CONFIDENTIAL INFORMATION – The information contained in this document belongs to TECHNIP. All IP rights relevant to this document are expressly reserved.
NOTE REV
CAUSE AND EFFECT CHART ABBREVIATIONS USED IN THE MATRIX :
A = Activate

1
UNIT or EQUIPMENT LOGIC IDENTIFICATION C= Close
O = Open

0003

0003
PID
S = Start
T = Trip
I = Inhibit
P = Permissive
R = Reset
V = oVerride

EFFECT
IS-03 Gas Turbine Shutdown

DESCRIPTION
SERVICE

Power Generation Package

Power Generation Package


NOTES :
1. Except otherwise indicated, all PIDs number
start by 077625-B41-PID-0021 for Barauni and
by 077625-S41-PID-0021 for Sindri.
2.Cause and Effect for the GTG-HRSG unit will
be further developed according to vendor
recommendations, if required.
3. For package equipments refer vendor Cause
and Effect Diagrams.

B41-PK-0002

B41-PK-0002
TAG No
4. GTG Emergency Shutdown
5.GTG Normal Shutdown
CAUSE
SERVICE PID OVERRIDE
REV NOTE TAG No.

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30
DESCRIPTION TAG No

9
C Deleted 1 1
2 2
3 3
4 4
5 5
1,4 GTG Emergency Conditions 0003 B41-HS-0701 6 T 6
7 7
8 8
9 9
10 10
1,5 MP Fuel Gas Temperature Low Low B45-IS-05 11 T 11
12 12
13 13
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
23 23
24 24
25 25
26 26
27 27
28 28
29 29
30 30
RESET
1 1
2 2
3 3
4 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 30

CAUSE AND EFFECT DIAGRAM Activity Unit Doc Type Mat. code Serial N° Page Rev.
077625 C41 DW 1514 0001 5 C

CONFIDENTIAL INFORMATION – The information contained in this document belongs to TECHNIP. All IP rights relevant to this document are expressly reserved.
NOTE REV
CAUSE AND EFFECT CHART ABBREVIATIONS USED IN THE MATRIX :
A = Activate

1
UNIT or EQUIPMENT LOGIC IDENTIFICATION C= Close
O = Open

0004
PID
S = Start
T = Trip
I = Inhibit
P = Permissive
R = Reset
V = oVerride

EFFECT
IS-04 HRSG Shutdown

Heat Recovery Steam Generator


DESCRIPTION
SERVICE
NOTES :
1 Except otherwise indicated, all PIDs number
start by 077625-B41-PID-0021 for Barauni and
by 077625-S41-PID-0021 for Sindri.
2.Cause and Effect for the GTG-HRSG unit will
be further developed according to vendor
recommendations, if required.
3. For package equipments refer vendor Cause
and Effect Diagrams.

TAG No

1 B41-H-0002
CAUSE
SERVICE PID OVERRIDE
REV NOTE TAG No.

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30
DESCRIPTION TAG No

9
C Deleted 1 1
2 2
3 3
4 4
5 5
1 HRSG Emergency Conditions 0004 B41-HS-0801 6 T 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
23 23
24 24
25 25
26 26
27 27
28 28
29 29
30 30
RESET
1 1
2 2
3 3
4 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 30

CAUSE AND EFFECT Activity Unit Doc Type Mat. code Serial N° Page Rev.
007625 C41 DW 1514 0001 6 C

CONFIDENTIAL INFORMATION – The information contained in this document belongs to TECHNIP. All IP rights relevant to this document are expressly reserved.

You might also like