OptiX OSN 3500/2500/1500

Hardware Description Manual Contents

Contents

3 Subrack.........................................................................................................................................3-1
3.1 Subrack for the OptiX OSN 3500 ............................................................................................... 3-1
3.1.1 Structure............................................................................................................................. 3-1
3.1.2 Slot Distribution................................................................................................................. 3-3
3.1.3 Boards and the Corresponding Slots.................................................................................. 3-4
3.1.4 Board and the Corresponding Slots for the External Subrack ........................................... 3-9
3.1.5 Technical Parameters ....................................................................................................... 3-10
3.2 Subrack for the OptiX OSN 2500 ............................................................................................. 3-10
3.2.1 Structure........................................................................................................................... 3-10
3.2.2 Slot Distribution............................................................................................................... 3-11
3.2.3 Boards and the Corresponding Slots................................................................................ 3-14
3.2.4 Technical Parameters ....................................................................................................... 3-18
3.3 Subrack for the OptiX OSN 2500 REG..................................................................................... 3-19
3.4 Subrack for the OptiX OSN 1500A........................................................................................... 3-20
3.4.1 Structure........................................................................................................................... 3-20
3.4.2 Slot Distribution............................................................................................................... 3-20
3.4.3 Boards and the Corresponding Slots................................................................................ 3-22
3.4.4 Technical Parameters ....................................................................................................... 3-24
3.5 Subrack for the OptiX OSN 1500B........................................................................................... 3-25
3.5.1 Structure........................................................................................................................... 3-25
3.5.2 Slot Distribution............................................................................................................... 3-26
3.5.3 Boards and the Corresponding Slots................................................................................ 3-28
3.5.4 Technical Parameters ....................................................................................................... 3-32

Issue 04 (2007-04-30) Huawei Technologies Proprietary i


OptiX OSN 3500/2500/1500
Hardware Description Manual Figures

Figures

Figure 3-1 Structure of the OptiX OSN 3500 subrack ..................................................................... 3-2
Figure 3-2 Slot distribution of the OptiX OSN 3500........................................................................ 3-3
Figure 3-3 Structure of the OptiX OSN 2500 subrack ................................................................... 3-11
Figure 3-4 Slot distribution of the OptiX OSN 2500 (before slot segmentation)........................... 3-12
Figure 3-5 Access capacity of the OptiX OSN 2500 (before slot segmentation) ........................... 3-12
Figure 3-6 Slot distribution of the OptiX OSN 2500 (after slot segmentation).............................. 3-13
Figure 3-7 Access capacity of the OptiX OSN 2500 (after slot segmentation) .............................. 3-13
Figure 3-8 Structure of the OptiX OSN 1500A.............................................................................. 3-20
Figure 3-9 Slot distribution of the OptiX OSN 1500A (before slot segmentation) ........................ 3-21
Figure 3-10 Slot distribution of the OptiX OSN 1500A (after slot segmentation) ......................... 3-21
Figure 3-11 Access capacity of the OptiX OSN 1500A ................................................................. 3-21
Figure 3-12 Structure of the OptiX OSN 1500B ............................................................................ 3-25
Figure 3-13 Slot distribution of the OptiX OSN 1500B (before slot segmentation) ...................... 3-26
Figure 3-14 Access capacity of the OptiX OSN 1500B (before slot segmentation)....................... 3-26
Figure 3-15 Slot distribution of the OptiX OSN 1500B (after slot segmentation) ......................... 3-27
Figure 3-16 Access capacity of the OptiX OSN 1500B (after slot segmentation) ......................... 3-27

Issue 04 (2007-04-30) Huawei Technologies Proprietary iii


OptiX OSN 3500/2500/1500
Hardware Description Manual Tables

Tables

Table 3-1 Slot mapping table for OptiX OSN 3500.......................................................................... 3-4
Table 3-2 The relation between processing boards and slots for the OptiX OSN 3500 (80 Gbit/s
cross-connect capacity) ..................................................................................................................... 3-4
Table 3-3 The relation between processing boards and slots for the OptiX OSN 3500 (40 Gbit/s
cross-connect capacity) ..................................................................................................................... 3-6
Table 3-4 The relation between interface boards and slots for the OptiX OSN 3500....................... 3-8
Table 3-5 The relation between other boards and slots for the OptiX OSN 3500 ............................ 3-9
Table 3-6 The relation between boards and slots for the OptiX OSN 3500 external subrack .......... 3-9
Table 3-7 Technical parameters of the OptiX OSN 3500 subrack .................................................. 3-10
Table 3-8 Slot mapping table for the OptiX OSN 2500.................................................................. 3-14
Table 3-9 The relation between processing boards and slots for the OptiX OSN 2500.................. 3-15
Table 3-10 The relation between interface boards and slots for the OptiX OSN 2500................... 3-17
Table 3-11 The relation between other boards and slots for the OptiX OSN 2500......................... 3-18
Table 3-12 Technical parameters of the OptiX OSN 2500 subrack ................................................ 3-18
Table 3-13 The relation between boards and slots for the OptiX OSN 2500 REG......................... 3-19
Table 3-14 The relation between processing boards and slots for the OptiX OSN 1500A............. 3-22
Table 3-15 The relation between other boards and slots for the OptiX OSN 1500A...................... 3-24
Table 3-16 Technical parameters of the OptiX OSN 1500A .......................................................... 3-24
Table 3-17 Slot mapping table for the OptiX OSN 1500B ............................................................. 3-28
Table 3-18 The relation between processing boards and slots for the OptiX OSN 1500B............. 3-29
Table 3-19 The relation between interface boards and slots for the OptiX OSN 1500B ................ 3-31
Table 3-20 The relation between other boards and slots for the OptiX OSN 1500B...................... 3-32
Table 3-21 Technical parameters of the OptiX OSN 1500B........................................................... 3-32

Issue 04 (2007-04-30) Huawei Technologies Proprietary v


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

3 Subrack

This chapter introduces the structure, slot distribution, and technical parameters of
the subrack of:
„ The OptiX OSN 3500
„ The OptiX OSN 2500
„ The OptiX OSN 2500 REG
„ The OptiX OSN 1500A
„ The OptiX OSN 1500B

3.1 Subrack for the OptiX OSN 3500


This section introduces the structure, slot distribution, and technical parameters of
the OptiX OSN 3500 subrack.

3.1.1 Structure
The subrack of the OptiX OSN 3500 adopts two-layer structure. It is divided into
board area, fan area, and fiber routing area, as shown in Figure 3-1.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-1


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

W D

1. Interface board area 2. Fan area 3. Processing board area 4. Fiber routing area
Figure 3-1 Structure of the OptiX OSN 3500 subrack

„ Interface board area: housing all interface boards of the OptiX OSN 3500
„ Fan area: housing three fan modules, enabling heat dissipation function
„ Processing board area: housing all processing boards of the OptiX OSN 3500
„ Fiber routing area: for fiber routing

3-2 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

3.1.2 Slot Distribution


The subrack of the OptiX OSN 3500 has two layers. The upper layer gives 16 slots
for interface boards. The lower layer gives 18 slots, 15 slots of them for processing
boards. Figure 3-2 shows the slot distribution.

S S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T T
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7

P P A
I I U
U U X

FAN 38 FAN 39 FAN 40

S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8

G G
X X S S
C C C C
S S C C

Fiber Routing

Figure 3-2 Slot distribution of the OptiX OSN 3500

Slots for Interface Boards


„ Service interface boards: slots 19–26, slots 29–36

Slots for Processing Boards


„ Service processing boards: slots 1–8 and slots 11–17

Slots for Other Boards


„ XCS boards: slots 9–10
„ GSCC boards: slots 17–18 (Slot 17 can also hold a service processing board)
„ Power interface boards: slot 27 and slot 28
„ Auxiliary interface boards: slot 37

Slot Mapping Table


Table 3-1 shows the slot mapping table which associates slots for processing boards
to the slots for its corresponding interface boards.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-3


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

Table 3-1 Slot mapping table for OptiX OSN 3500


Slot for processing Slots for corresponding Slot for processing Slots for corresponding
boards interface boards boards interface boards

Slot 2 Slots 19, 20 Slot 3 Slots 21, 22


Slot 4 Slots 23, 24 Slot 5 Slots 25, 26
Slot 13 Slots 29, 30 Slot 14 Slots 31, 32
Slot 15 Slots 33, 34 Slot 16 Slots 35, 36

3.1.3 Boards and the Corresponding Slots


Processing Boards
The OptiX OSN 3500 offers an 80 Gbit/s or 40 Gbit/s cross-connect capacity
depending on the type of cross-connect boards. Table 3-2 and Table 3-3 associate
processing boards to the corresponding slots under the two cross-connect
configurations.

Table 3-2 The relation between processing boards and slots for the OptiX OSN 3500 (80
Gbit/s cross-connect capacity)
Slot 13–slot 14 (2.5
Slot 11–slot 12 (10
Slot 2–slot 4 (1.25

Slot 2–slot 5, slot


Slots and capacity
Slot 5–slot 6 (2.5

Slot 7–slot 8 (10

Slot 15–slot 16
(1.25 Gbit/s )

(1.25 Gbit/s )

(1.25 Gbit/s )

13–slot 16
Gbit/s )

Gbit/s)

Gbit/s)

Gbit/s)

Gbit/s)

Slot 17
Slot 1

Boards

N2SL64 - - 9 9 - - - -
N1SF16, - - 9 9 9 9 - - -
N1/N2SL16(A)
N1/N2SLQ4 - - 9 9 9 9 - - -
N1/N2SLD4, 9 9 9 9 9 9 9 9 -
N1/N2SL4,
N1/N2SLQ1,
N1/N2SL1
N1SLT1 (Note 1) 9 9 9 9 9 9 9 - -
N1SEP (Note 2) - - - - - - - - 9
N1SEP1 (Note 2) 9 9 9 9 9
N1/N2SPQ4, N1PD3, - - - - - - - - 9
N1PL3
N1PL3A 9 9 9 9 9 9 9 9 -

3-4 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

Slot 13–slot 14 (2.5


Slot 11–slot 12 (10
Slot 2–slot 4 (1.25

Slot 2–slot 5, slot


Slots and capacity

Slot 5–slot 6 (2.5

Slot 7–slot 8 (10

Slot 15–slot 16
(1.25 Gbit/s )

(1.25 Gbit/s )

(1.25 Gbit/s )

13–slot 16
Gbit/s )

Gbit/s)

Gbit/s)

Gbit/s)

Gbit/s)

Slot 17
Slot 1
Boards

N1PQ1, N1PQM 9 - - - - - - - 9
N1EFS4 9 9 9 9 9 9 9 9 -
N1/N2EFS0 - - - - - - - - 9
N1EGS2 - - 9 9 9 9 - - -
N2EGS2, N1EGT2, 9 9 9 9 9 9 9 - -
N2EGR2
N1EFT8(work with - - - - - - - - 9
interface boards)
N1EFT8 (led out from 9 9 9 - - 9 9 - -
front panel)
N1/N2EMR0 (work - - - - - - - - 9
with interface boards)
N1/N2EMR0 (led out 9 9 9 - - 9 9 - -
from front panel)
N1ADL4, N1ADQ1, 9 9 9 9 9 9 9 9 -
N1IDQ1, N1IDL4 (Note
3)
N1MST4 9 9 9 9 9 9 9 - -
N1MR2A 9 9 9 9 9 9 9 9 -
N1MR2C (Note 4) - - - - - - - - -
N1LWX 9 9 9 9 9 9 9 9 -
N1/N2DCU, N1BA2, 9 9 9 9 9 9 9 9 -
N1BPA
Note 1: The SLT1 provides 1–8 optical interfaces when in slots 1–4 or slots 15–16. The SLT1 provides 1–12 optical interfaces when
in slots 5–8 or slot 11–14.
Note 2: On the T2000, the SEP1 is displayed as SEP1 when led out directly from the front panel, or displayed as SEP when working
with interface boards.
Note 3: The maximum bandwidth at SDH side for the N1ADL4, N1ADQ1, N1IDL4, and N1IDQ1 is 1.25 Gbit/s.
Note 4: The N1MR2C seats in any of slots 19–26 or slots 29–36.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-5


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

Table 3-3 The relation between processing boards and slots for the OptiX OSN 3500 (40
Gbit/s cross-connect capacity)
Slots and

Slot 14–slot 16 (622


Slot 12–slot 13 (2.5

Slot 2–slot 5, slot


Slot 2–slot 5 (622

Slot 6–slot 7 (2.5


capacity

(622 Mbit/s )

(622 Mbit/s )
(10 Gbit/s)

(10 Gbit/s)

13–slot6
Mbit/s )

Mbit/s )
Gbit/s)

Gbit/s)
Slot 11

Slot 17
Slot 1

Slot 8
Boards

N2SL64 - - - 9 9 - - - -
N1SF16, - - 9 9 9 9 - - -
N1/N2SL16(A)
N1/N2SLQ4, - - 9 9 9 9 - - -
N1/N2SLD4
N1/N2SL4, 9 9 9 9 9 9 9 - -
N1/N2SLQ1,
N1/N2SL1,
N1SLT1 (Note
1)
N1SEP (Note 2) - - - - - - - - 9
N1SEP1 (Note 9 9 only - - only 9 - -
2) slot slot 13
6
N1/N2SPQ4, - - - - - - - - 9
N1PD3, N1PL3
N1PL3A 9 9 9 9 9 9 9 - -
N1PQ1, 9 - - - - - - - 9
N1PQM
N1EFS4 9 9 9 9 9 9 9 - -
N1/N2EFS0 - - - - - - - - 9
N1EGS2 - - 9 9 9 9 - - -
N2EGS2, 9 9 9 9 9 9 9 - -
N1EGT2,
N2EGR2
N1EFT8 (work - - - - - - - - only slot
with interface 13
boards)
N1EFT8 (led 9 9 only - - only 9 - -
out from front slot slot 13
panel) 6

3-6 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

Slots and

Slot 14–slot 16 (622


Slot 12–slot 13 (2.5

Slot 2–slot 5, slot


Slot 2–slot 5 (622

Slot 6–slot 7 (2.5


capacity

(622 Mbit/s )

(622 Mbit/s )
(10 Gbit/s)

(10 Gbit/s)

13–slot6
Mbit/s )

Mbit/s )
Gbit/s)

Gbit/s)
Slot 11

Slot 17
Slot 1

Slot 8
Boards

N1/N2EMR0 - - - - - - - - 9
(work with
interface
boards)
N1/N2EMR0 9 9 only - - only 9 - -
(led out from slot slot 13
front panel) 6
N1ADL4, - - 9 9 9 9 - - -
N1ADQ1 (Note
3)
N1IDQ1, 9 9 9 9 9 9 9 - -
N1IDL4 (Note
3)
N1MST4 9 9 9 9 9 9 9 - -
N1MR2A 9 9 9 9 9 9 9 - -
N1MR2C (Note - -
4)
N1LWX 9 9 9 9 9 9 9 - -
N1/N2DCU, 9 9 9 9 9 9 9 - -
N1BA2,
N1BPA
Note 1: The SLT1 provides 1–4 optical interfaces when in slots 1–5 or slots 14–16. The SLT1 provides 1–12 optical interfaces when
in slots 6–8 or slot 11–13.
Note 2: The N1SEP1 and N1SEP are the same physically. They are used with the interface board when they are configured as
"N1SEP" on the T2000, or the signal is directly led out from the front panel when they are configured as "N1SEP1".
Note 3: The maximum bandwidth at SDH side for the N1ADL4, N1ADQ1 is 1.25 Gbit/s. The maximum bandwidth at SDH side for
the N1IDL4 and N1IDQ1 is 622Mbit/s when in slots 1~5 or slots 14~16. The maximum bandwidth at SDH side for the N1IDL4 and
N1IDQ1 is 1.25 Gbit/s when in slots 6~8 or slots 11~13.
Note 4: The N1MR2C seats in any of slots 19–26 or slots 29–36.

Interface Boards
Table 3-4 associates interface boards to the corresponding slots.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-7


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

Table 3-4 The relation between interface boards and slots for the OptiX OSN 3500
Slots

Slot 19

Slot 20

Slot 21

Slot 22

Slot 23

Slot 24

Slot 25

Slot 26

Slot 29

Slot 30

Slot 31

Slot 32

Slot 33

Slot 34

Slot 35

Slot 36
Boards

N1EU08 (Note) 9 - 9 - 9 - 9 - 9 - 9 - 9 - 9 -
N1OU08 9 - 9 - 9 - 9 - 9 - 9 - 9 - 9 -
(LC interface)
(Note)
N2OU08 9 - 9 - 9 - 9 - 9 - 9 - 9 - 9 -
(SC interface)
(Note)
N1EU04 9 - 9 - 9 - 9 - 9 - 9 - 9 - 9 -
N1MU04 9 - 9 - 9 - 9 - 9 - 9 - 9 - 9 -
N1C34S 9 - 9 - 9 - 9 - 9 - 9 - 9 - 9 -
N1D34S 9 - 9 - 9 - 9 - 9 - 9 - 9 - 9 -
N1D75S 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9
N1D12S 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9
N1D12B 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9
N1ETF8 9 - 9 - 9 - 9 - 9 - 9 - 9 - 9 -
N1EFF8 9 - 9 - 9 - 9 - 9 - 9 - 9 - 9 -
N1ETS8 9 - 9 - 9 - 9 - 9 - 9 - 9 - 9 -
N1TSB8 9 - - - - - - - - - - - - - 9 -
N1TSB4 9 - - - - - - - - - - - - - 9 -
Note 1: The OptiX OSN 3500 does not support the N1EU08, N1OU08, and N2OU08 board when the cross-connect capacity is 40
Gbit/s.

Other Boards
Table 3-5 associates cross-connect boards, SCC boards, and auxiliary interface
boards to the corresponding slots.

3-8 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

Table 3-5 The relation between other boards and slots for the OptiX OSN 3500
Slots

Slot 101–slot 102


Slot 17–slot 18

Slot 27–slot 28

Slot 38–slot 40

Slot 59–slot 60
Slot 9–slot 10

Slot 37
Boards

N1GXCSA 9 - - - - - -
N1EXCSA 9 - - - - - -
N1UXCSA 9 - - - - - -
N1UXCSB 9 - - - - - -
N1XCE - - - - - 9 -
(Note 1)
N1GSCC - 9 - - - - -
N1PIU - - 9 - - - -
N1AUX - - - 9 - - -
N1FAN - - - - 9 - -
N1FANA - - - - 9 - -
N1COA, - - - - - - 9
61COA,
62COA
(Note 2)
Note 1: The N1XCE can only seat in the extended subrack of the OptiX OSN 3500. Slots for the N1XCE are
slot 59 and slot 60.
Note 2: The corresponding slots for the N1COA, 61COA, and 62COA are logical slots, not physical slots.

3.1.4 Board and the Corresponding Slots for the External Subrack
Table 3-6 associates boards supported by the external subrack to the corresponding
slots.

Table 3-6 The relation between boards and slots for the OptiX OSN 3500 external subrack
Slots slot 51~slot 55 slot 63~slot 66 slot 69~slot 76 slot 79~slot 86
Board

N1PQ1, 9 9 - -
N1PQM
N1MR2A 9 9 - -
N1D75S - - 9 9

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-9


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

Slots slot 51~slot 55 slot 63~slot 66 slot 69~slot 76 slot 79~slot 86


Board

N1D12S - - 9 9
N1D12B - - 9 9
N1MR2C - - 9 9

3.1.5 Technical Parameters


Table 3-7 lists the technical parameters of the subrack of the OptiX OSN 3500.

Table 3-7 Technical parameters of the OptiX OSN 3500 subrack


Dimensions 722 mm (H) x 497 mm (W) x 295 mm (D)
Weight 23 kg (net weight of the subrack, not including boards and fans)

3.2 Subrack for the OptiX OSN 2500


This section introduces the structure, slot distribution, and technical parameters of
the OptiX OSN 2500 subrack.

3.2.1 Structure
The subrack of the OptiX OSN 2500 adopts one-layer structure. It is divided into
processing board area, interface board area, auxiliary interface area, fan area, and
fiber routing area, as shown in Figure 3-1.

3-10 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

2 1

W
D

1. Auxiliary interface area 2. Interface board area 3. Processing board area


4. PIU area 5. Fan area
Figure 3-3 Structure of the OptiX OSN 2500 subrack

„ Auxiliary interface area: including alarm interfaces, orderwire interface, clock


interfaces, operation and maintenance interfaces, F1 port, serial ports and so
on
„ Interface board area: housing the interface boards of the OptiX OSN 2500
„ Processing board area: housing the processing boards of the OptiX OSN 2500
and cross-connect and timing board.
„ PIU area: housing two PIU modules, providing power for the OptiX OSN
2500
„ Fan area: housing two fan modules, enabling heat dissipation function

3.2.2 Slot Distribution


The subrack of the OptiX OSN 2500 has eight slots for interface boards and ten
slots for processing boards. Figure 3-4 shows the slot distribution. Figure 3-5 shows
the access capacity for the subrack.
The OptiX OSN 2500 subrack supports slot segmentation. Slots 5, 6, and 7 can be
segmented into two half-height slots respectively.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-11


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Processing board
Processing board
Processing board
Processing board

Processing board
Processing board
Processing board
Interface board
Interface board
Interface board
Interface board

Interface board
Interface board
Interface board
Interface board
CXL16/4/1
CXL16/4/1

SAP
Fiber routing
PIU FAN FAN PIU
(Slot 22) (Slot 24) (Slot 25) (Slot 23)

Figure 3-4 Slot distribution of the OptiX OSN 2500 (before slot segmentation)

S S
S S S S S S S S
L L
L L L L L L L L
O O S S S S
S S S S O O O O O O O O
T T L L L L
L L L L T T T T T T T T
9 10 O O O O
O O O O 5 6 7 8 11 12 13 14
T T T T
T T T T
1 1 1 1
1 2 3 4 S
CXL16/4/1
CXL16/4/1

1.25Gbit/s

5 6 7 8
622Mbit/s
622Mbit/s
2.5Gbit/s
2.5Gbit/s

2.5Gbit/s
2.5Gbit/s

A
P

Fiber Routing
PIU FAN FAN PIU
SLOT22 SLOT24 SLOT25 SLOT23

Figure 3-5 Access capacity of the OptiX OSN 2500 (before slot segmentation)

After segmentation, the slot distribution is shown in Figure 3-6, and the access
capacity is shown in Figure 3-7.

3-12 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T
1 2 3 4 19 20 21 8 9 10 11 12 13 14 15 16 17 18

Interface board
Interface board
Interface board
Interface board
Interface board
Interface board
Interface board
Interface board

CXL16/4/1
CXL16/4/1
S S S
L L L

SAP
O O O
T T T
5 6 7

Fiber routing
PIU FAN FAN PIU
(Slot 22) (Slot 24) (Slot 25) (Slot 23)

Figure 3-6 Slot distribution of the OptiX OSN 2500 (after slot segmentation)

S S S
L L L
O O O S S
T T T S L L S S S S
19 20 21 L O O L L L L
S S S S
1.25 Gbit/s
622 Mbit/s

622 Mbit/s

S S S S O O O O O
T T L L L L
L L L L T T T T T
9 10 O O O O
O O O O 8 11 12 13 14
T T T T
T T T T S S S
C C 1 1 1 1
1 2 3 4 L L L S
O O O X X 5 6 7 8
1.25 Gbit/s

A
2.5 Gbit/s

2.5 Gbit/s

2.5 Gbit/s

T T T L L
16 P
5 6 7 16
622 Mbit/s

622 Mbit/s

1.25 Gbit/s

/4 /4
/1 /1
Fiber routing
PIU FAN FAN PIU
(Slot 22) (Slot 24) (Slot 25) (Slot 23)

Figure 3-7 Access capacity of the OptiX OSN 2500 (after slot segmentation)

Slots for Interface Boards


„ Service interface boards: slots 1-4, slots 15-18

Slots for Processing Boards


„ Service processing boards: slots 5-8 and slots 11-13 (before slot
segmentation)

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-13


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

„ Service processing boards: slots 5-8, slots 11-13, and slots 19-21 (after slot
segmentation)
„ CXL boards: slots 9-10
„ SAP boards: slot 14

Slots for Other Boards


„ SEI auxiliary interface boards: auxiliary interface area
„ Power interface boards: slots 22-23
„ Fan units: slots 24-25

Slot Mapping Table


Table 3-8 shows the slot mapping table which associates slots for processing boards
to the slots for its corresponding interface boards.

Table 3-8 Slot mapping table for the OptiX OSN 2500
Slot for processing Slots for corresponding Slot for processing Slots for corresponding
boards interface boards boards interface boards

Slot 6 Slots 1, 2 Slot 7 Slots 3, 4


Slot 12 Slots 15, 16 Slot 13 Slots 17, 18
Slot 6 (Note) Slots 2 Slot 20 (Note) Slots 1
Slot 7 (Note) Slots 4 Slot 21 (Note) Slots 3
Note: The slot is half-height slot after slot segmentation.

3.2.3 Boards and the Corresponding Slots


Processing Boards
Table 3-9 associates processing boards to the corresponding slots.

3-14 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

Table 3-9 The relation between processing boards and slots for the OptiX OSN 2500
Slots and Before slot segmentation After slot
capacity segmentation

Slot 7, Slot 21 (1.25


Slot 5–Slot 6 , Slot
(1.25 Gbit/s )
(622 Mbit/s )

(622 Mbit/s )

(622 Mbit/s )
(2.5 Gbit/s)

(2.5 Gbit/s)

(2.5 Gbit/s)

(2.5 Gbit/s)

19–Slot 20

Gbit/s )
Slot 11

Slot 12

Slot 13
Slot 5

Slot 6

Slot 7

Slot 8
Boards

N1SF16, - - 9 9 9 9 - - -
N1/N2SL16(A),
N1/N2SLQ4
N1/N2SLD4 - - 9 9 9 9 9 - -
N1/N2SL4, 9 9 9 9 9 9 9 - -
N1/N2SLQ1,
N1/N2SL1,
N1SLT1 (Note 1)
R1SLD4 - - - - - - - - 9
R1SL4, R1SLQ1, - - - - - - - 9 9
R1SL1
N1SEP (work - 9 9 9 9 - -
with interface
boards) (Note 2)
N1SEP1 (led out 9 9 9 9 9 9 9 - -
from front panel)
(Note 2)
N1/N2SPQ4, - 9 9 - - 9 9 - -
N1PD3, N1PL3
N1PL3A 9 9 9 9 9 9 9 - -
N1PQ1, N1PQM 9 9 9 - - 9 9 - -
R1PD1 - - - - - - - 9 9
R1EFT4 - - - - - - - 9 9
N1EFS4 9 9 9 9 9 9 9 - -
N1/N2EFS0 - 9 9 - - 9 9 - -
N2EGS2, 9 9 9 9 9 9 9 - -
N1EGT2,
N2EGR2
N1EGS2 - - 9 9 9 9 - - -

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-15


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

Slots and Before slot segmentation After slot


capacity segmentation

Slot 7, Slot 21 (1.25


Slot 5–Slot 6 , Slot
(1.25 Gbit/s )
(622 Mbit/s )

(622 Mbit/s )

(622 Mbit/s )
(2.5 Gbit/s)

(2.5 Gbit/s)

(2.5 Gbit/s)

(2.5 Gbit/s)

19–Slot 20

Gbit/s )
Slot 11

Slot 12

Slot 13
Slot 5

Slot 6

Slot 7

Slot 8
Boards

N1EFT8 (work - - 9 - - 9 9 - -
with interface
boards)
N1EFT8 (led out 9 9 9 9 9 9 9 - -
from front panel)
N1/N2EMR0 - 9 9 - - 9 9 - -
(work with
interface boards)
N1/N2EMR0 (led 9 9 9 9 9 9 9 - -
out from front
panel)
N1ADL4, - - 9 9 9 9 9 - -
N1ADQ1
N1IDQ1, 9 9 9 9 9 9 9 - -
N1IDL4 (Note 3)
N1MST4 9 9 9 9 9 9 9 - -
N1MR2A 9 9 9 9 9 9 9 - -
N1MR2B - - - - - - - 9 9
N1MR2C (Note - - - - - - - - -
4)
N1LWX 9 9 9 9 9 9 9 - -
N1BA2, N1BPA 9 9 9 9 9 9 9 - -
Note 1: The SLT1 provides 1–4 optical interfaces when in slots 5–6. The SLT1 provides 1–12 optical interfaces when in slots 7–8 or
slots 11–12. The SLT1 provides 1–8 optical interfaces when in slot 13.
Note 2: On the T2000, the SEP1 is displayed as SEP1 when led out directly from the front panel, or displayed as SEP when working
with interface boards.
Note 3: The maximum bandwidth at SDH side for the N1ADL4 and N1ADQ1 is 1.25 Gbit/s. The maximum bandwidth at SDH side
for the N1IDL4 and N1IDQ1 is 622Mbit/s when in slots 5~6. The maximum bandwidth at SDH side for the N1IDL4 and N1IDQ1 is
1.25 Gbit/s when in slots 7~8 or slots 11~13.
Note 4: The N1MR2C seats in any of slots 1–4 or slots 15–18.

3-16 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

Interface Boards
Table 3-10 associates interface boards to the corresponding slots.

Table 3-10 The relation between interface boards and slots for the OptiX OSN 2500
Slots

Slot 15

Slot 16

Slot 17

Slot 18
Slot 1

Slot 2

Slot 3

Slot 4
Boards

N1EU08 - - 9 - 9 - 9 -
N1OU08 - - 9 - 9 - 9 -
(LC type)
N2OU08 - - 9 - 9 - 9 -
(SC type)
N1EU04 9 - 9 - 9 - 9 -
N1MU04 9 - 9 - 9 - 9 -
N1C34S 9 - 9 - 9 - 9 -
N1D34S 9 - 9 - 9 - 9 -
N1D75S 9 9 9 9 9 9 9 9
N1D12S 9 9 9 9 9 9 9 9
N1D12B 9 9 9 9 9 9 9 9
N1ETF8 9 - 9 - 9 - 9 -
N1EFF8 9 - 9 - 9 - 9 -
N1ETS8 9 - 9 - 9 - 9 -
N1TSB8 9 - - - - - 9 -
N1TSB4 9 - - - - - 9 -

Other Boards
Table 3-11 associates cross-connect boards, SCC boards, and auxiliary interface
boards to the corresponding slots.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-17


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

Table 3-11 The relation between other boards and slots for the OptiX OSN 2500
Slots

Slot 101–slot 102


Slot 22–slot 23

Slot 24–slot 25
Slot 9–slot 10

SEI area
Slot 14

Slot 50
Boards

Q1CXL1/4/16, 9 - - - - - -
Q2CXL1/4/16
(physical board)
GSCC, SCC slot 82–slot - - - - - -
(logical board) 83
CXL, ECXL slot 80–slot - - - - - -
(logical board) 81
(Note 1)
Q1SL1/4/16 9 - - - - - -
(logical board)
Q1SAP - 9 - - - - -
Q1PIU - - 9 - - - -
Q1SEI - - - - - 9 -
N1FAN - - - 9 - - -
N1COA, - - - - - - 9
61COA,
62COA (Note 2)
CAU (Note 2) - - - - 9 - -
Note 1: The CXL is a line, system control, cross-connect and timing board of the OptiX OSN 2500. It seats in
slot 9 and slot 10. On the T2000, it is displayed as three board types: CXL, SCC and SL1/4/16, respectively
occupying the logic slots 80–81, 82–83 and 9–10.
Note 2: The corresponding slots for the CAU, N1COA, 61COA and 62COA are logical slots, not physical
slots.

3.2.4 Technical Parameters


Table 3-12 lists the technical parameters of the subrack of the OptiX OSN 2500.

Table 3-12 Technical parameters of the OptiX OSN 2500 subrack


Dimensions 472 mm (H) x 447 mm (W) x 295 mm (D)
Weight 17 kg (net weight of the subrack, not including boards and fans)

3-18 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

3.3 Subrack for the OptiX OSN 2500 REG


The OptiX OSN 2500 REG is used to regenerate STM-16 and STM-64 signals.
The OptiX OSN 2500 REG subrack is similar with the OptiX OSN 2500 subrack.
The subrack structure and slot assignment are the same as those of the OptiX OSN
2500. This section mainly describes the basic configuration of the REG.
Table 3-13 associates OptiX OSN 2500 REG boards to the corresponding slots.

Table 3-13 The relation between boards and slots for the OptiX OSN 2500 REG
Slots

Slot 22 –slot 23

Slot 24–slot 25

SEI area
Slot 10

Slot 11

Slot 12

Slot 13

Slot 14
Slot 5

Slot 6

Slot 7

Slot 8

Slot 9

Boards

N2SL16 9 9 9 9 - - 9 9 9 - - - -
N2SL64 9 9 9 9 - - 9 9 9 - - - -
N1SF16 9 9 9 9 - - 9 9 9 - - - -
Q1CRG - - - 9 9 - - - - - - -
Q1SAP - - - - - - - - - 9 - -
Q1PIU - - - - - - - - - - 9 - -
N1FAN - - - - - - - - - - - 9 -
Q1SEI - - - - - - - - - - - - 9
N1BA2 9 9 9 9 - - 9 9 9 - - - -
N1BPA 9 9 9 9 - - 9 9 9 - - - -
N1/N2DCU 9 9 9 9 - - 9 9 9 - - - -

The OptiX OSN 2500 REG can also be configured with UPM and COA as required
for their specific slots. The configuration boards outside are same to those of the
OptiX OSN 2500.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-19


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

3.4 Subrack for the OptiX OSN 1500A


This section introduces the structure, slot distribution, and technical parameters of
the OptiX OSN 1500A subrack.

3.4.1 Structure
The OptiX OSN 1500A adopts one-layer structure. It is divided into board area, fan
area, PIU area and fiber routing area, as shown in Figure 3-8.

2 H

3 W
D
4
6

1. Fan area 2. Board area 3. PIU area


4. Interface Board 5. Fiber routing area 6. Mounting ear
Figure 3-8 Structure of the OptiX OSN 1500A

„ Board area: for holding the boards of the OptiX OSN 1500A
„ Fan area: housing one fan tray assembly, enabling heat dissipation function
„ PIU area: housing two PIU boards, providing power for the OptiX OSN
1500A
„ Fiber routing area: for fiber routing

3.4.2 Slot Distribution


The OptiX OSN 1500A has 12 slots before slot segmentation. Figure 3-9 shows the
slot distribution.

3-20 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

Slot 1 Slot 11 Slot 6

Slot 20 Slot 12 Slot 7


Slot 13 Slot 8
FAN Slot 4 CXL16/4/1 Slot 9 EOW
Slot 5 CXL16/4/1 Slot 10 AUX

Figure 3-9 Slot distribution of the OptiX OSN 1500A (before slot segmentation)

The OptiX OSN 1500A supports slot segmentation. Slots 12 and 13 can be
segmented into two half-height slots respectively. After segmentation, the slot
distribution is shown in Figure 3-10.
Slot 1 Slot 11 Slot 6

Slot 20 Slot 2 Slot 12 Slot 7


Slot 3 Slot 13 Slot 8
FAN Slot 4 CXL16/4/1 Slot 9 EOW
Slot 5 CXL16/4/1 Slot 10 AUX

Figure 3-10 Slot distribution of the OptiX OSN 1500A (after slot segmentation)

Figure 3-11 shows the access capacity for the OptiX OSN 1500A.

Slot
XCS A 1 XCS B
Slot 11 Slot 6 1.25 Gbit/s

Slot 2/12 2.5 Gbit/s Slot 7 1.25 Gbit/s


Slot20
Slot 3/13 2.5 Gbit/s Slot 8 1.25 Gbit/s

Slot 4 2.5 Gbit/s Slot 9 1.25 Gbit/s

Slot 5 2.5 Gbit/s Slot 10

Figure 3-11 Access capacity of the OptiX OSN 1500A

The access capacity for slot 12 or slot 13 is 2.5 Gbit/s before slot segmentation.
After slot segmentation, the access capacity for half-height slot 2, slot 3, slot 12 or
slot 13 is 1.25 Gbit/s.

Slots for Processing Boards


„ Service processing boards: slots 6–9 and slots 12–13 (before slot
segmentation)
„ Service processing boards: slots 6–9, slots 12–13, slots 2–3 (after slot
segmentation)
„ CXL boards: slots 4–5
„ EOW boards: slot 9(also for the processing boards)

Slots for Other Boards


„ Auxiliary interface boards: slot 10
„ Power interface boards: slot 1 and slot 11

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-21


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

„ Fan units: slot 20

3.4.3 Boards and the Corresponding Slots


Processing Boards
Table 3-14 associates processing boards to the corresponding slots.

Table 3-14 The relation between processing boards and slots for the OptiX OSN 1500A
Slots and Before slot segmentation After slot segmentation
capacity

Slot 12–slot 13 (2.5


(1.25 Gbit/s )

(1.25 Gbit/s )

(1.25 Gbit/s )
(1.25 Gbit/s)

(1.25 Gbit/s)

(1.25 Gbit/s)

(1.25 Gbit/s)

(1.25 Gbit/s)
Gbit/s)

Slot 12

Slot 13
Slot 6

Slot 7

Slot 8

Slot 9

Slot 2

Slot 3
Boards

N1SF16, - - - - 9 - - - -
N1/N2SL16(A),
N1/N2SLQ4,
N1/N2SLD4,
N1/N2SL4,
N1/N2SLQ1,
N1/N2SL1,
N1SLT1 (Note
1)
N1SEP1 (led - - - - 9 - - - -
out from front
panel)
R1SLD4, 9 9 9 9 - 9 9 9 9
R1SL4,
R1SLQ1,
R1SL1
R1PD1A, - - - - - 9 - 9 -
R1PD1B
R1PL1A, 9 9 9 9 - - - - -
R1PL1B
N1PL3A - - - - 9 - - - -
R1L75S, 9 9 - - - - - - -
R1L12S
N1EFS4 - - - - 9 - - - -
R1EFT4 9 9 9 9 - 9 9 9 9

3-22 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

Slots and Before slot segmentation After slot segmentation


capacity

Slot 12–slot 13 (2.5


(1.25 Gbit/s )

(1.25 Gbit/s )

(1.25 Gbit/s )
(1.25 Gbit/s)

(1.25 Gbit/s)

(1.25 Gbit/s)

(1.25 Gbit/s)

(1.25 Gbit/s)
Gbit/s)

Slot 12

Slot 13
Slot 6

Slot 7

Slot 8

Slot 9

Slot 2

Slot 3
Boards

N1/N2EGS2, - - - - 9 - - - -
N1EGT2,
N2EGR2
N1EFT8 (led - - - - 9 - - - -
out from front
panel)
N1/N2EMR0 - - - - 9 - - - -
(led out from
front panel)
N1MST4 - - - - 9 - - - -
N1ADL4(Note - - - - 9 - - - -
2),
N1ADQ1(Note
2)
N1IDQ1(Note - - - - 9 - - - -
2),
N1IDL4(Note
2)
N1MR2A - - - - 9 - - - -
N1MR2B 9 9 9 9 - 9 9 9 9
N1LWX - - - - 9 - - - -
N1BA2, - - - - 9 - - - -
N1BPA
Note 1: The SLT1 in the OptiX OSN 1500A provides 1–12 optical interfaces.
Note 2: The maximum bandwidth at SDH side for the N1ADL4, N1ADQ1, N1IDL4, and N1IDQ1 is 1.25 Gbit/s.

Other Boards
Table 3-15 associates cross-connect boards, SCC boards, and auxiliary interface
boards to the corresponding slots.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-23


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

Table 3-15 The relation between other boards and slots for the OptiX OSN 1500A
Boards

Slot 101–slot 102


Slot 1, slot 11
Slot 4–slot 5

Slot 10

Slot 20

Slot 50
Slot 9
Slots

Q1CXL1/4/16, 9 - - - - - -
Q2CXL1/4/16
(physical board)
(Note 1)
GSCC, SCC Slots 82, - - - - - -
(logical board) 83
CXL, ECXL Slots 80, - - - - - -
(logical board) 81
Q1SL1/4/16 9 - - - - - -
(logical board)
R1EOW - 9 - - - - -
R1AUX, R2AUX - - 9 - - - -
R1PIUA - - - 9 - - -
R1FAN - - - - 9 - -
N1COA, 61COA, - - - - - - 9
62COA (Note 2)
CAU (Note 2) - - - - - 9 -
Note 1: The CXL is a line, system control, cross-connect and timing board of the OptiX OSN 1500. It seats in
slot 4 and slot 5. On the T2000, it is displayed as three board types: CXL, SCC and SL1/4/16, respectively
occupying the logic slots 80–81, 82–83 and 4–5.
Note 2: The corresponding slots for the N1COA, 61COA, 62COA, and CAU are logical slots, not physical
slots.

3.4.4 Technical Parameters


Table 3-16 lists the technical parameters of the OptiX OSN 1500A equipment.

Table 3-16 Technical parameters of the OptiX OSN 1500A


Dimensions 131mm mm (H) x 444 mm (W) x 262 mm (D)
Weight 8 kg (including backboard, 2 pieces PIU and fan)

3-24 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

3.5 Subrack for the OptiX OSN 1500B


This section introduces the structure, slot distribution, and technical parameters of
the OptiX OSN 1500B subrack.

3.5.1 Structure
The OptiX OSN 1500B adopts two-layer structure. It is divided into processing
board area, interface board area, auxiliary interface area, fan area, and PIU area, as
shown in Figure 3-12.

2
3

4
4

5 7 W
D
6

1. Interface board area 2. PIU area 3. Fan area


4. Processing board area 5. Auxiliary interface area 6. Fiber routing area
7. Mounting ear
Figure 3-12 Structure of the OptiX OSN 1500B

„ Processing board area: for holding the processing boards of the OptiX OSN
1500B
„ Interface board area: for holding the interface boards of the OptiX OSN
1500B
„ Auxiliary interface area: including alarm interfaces, orderwire interface, clock
interfaces, operation and maintenance interfaces, F1 port, serial ports and so
on
„ Fan area: housing one fan module, enabling heat dissipation function

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-25


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

„ PIU area: housing PIU modules, providing power for equipment


„ Fiber routing area: for fiber routing

3.5.2 Slot Distribution


The OptiX OSN 1500B has four slots for interface boards on the upper layer and
ten slots (including slot 4 and slot 5) for processing boards before slot segmentation.
Figure 3-13 shows the slot distribution. Figure 3-14 shows the access capacity for
the OptiX OSN 1500B.
Slot 14
Slot 18 PIU
Slot 15

Slot 16
Slot 19 PIU
Slot 17

Slot 11 Slot 6

Slot 20 Slot 12 Slot 7

Slot 13 Slot 8
FAN Slot 4 CXL16/4/1 Slot 9 EOW
Slot 5 CXL16/4/1 Slot 10 AUX

Figure 3-13 Slot distribution of the OptiX OSN 1500B (before slot segmentation)

Slot 14
Slot 18 PIU
Slot 15
Slot 16
Slot 19 PIU
Slot 17
Slot 11 2.5 Gbit/s Slot 6 622 Mbit/s

Slot 20 Slot 12 2.5 Gbit/s Slot 7 622 Mbit/s


Slot 13 2.5 Gbit/s Slot 8 622 Mbit/s
FAN Slot 4 2.5 Gbit/s Slot 9 622 Mbit/s
Slot 5 2.5 Gbit/s Slot 10 AUX

Figure 3-14 Access capacity of the OptiX OSN 1500B (before slot segmentation)

The OptiX OSN 1500B supports slot segmentation. Slots 11, 12, and13 can be
segmented into two half-height slots respectively. After segmentation, the slot
distribution is shown in Figure 3-15, and the access capacity is shown in Figure
3-16.

3-26 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

Slot 14
Slot 18 PIU
Slot 15

Slot 16
Slot 19 PIU
Slot 17
Slot 1 Slot 11 Slot 6

Slot 20 Slot 2 Slot 12 Slot 7

Slot 3 Slot 13 Slot 8


FAN Slot 4 CXL16/4/1 Slot 9 EOW
Slot 5 CXL16/4/1 Slot 10 AUX

Figure 3-15 Slot distribution of the OptiX OSN 1500B (after slot segmentation)

Slot 14
Slot 18 PIU
Slot 15
Slot 16
Slot 19 PIU
Slot 17
Slot 1 1.25 Gbit/s Slot 11 1.25 Gbit/s Slot 6 622 Mbit/s

Slot 20 Slot 2 1.25 Gbit/s Slot 12 1.25 Gbit/s Slot 7 622 Mbit/s
Slot 3 1.25 Gbit/s Slot 13 1.25 Gbit/s Slot 8 622 Mbit/s
FAN Slot 4 2.5 Gbit/s Slot 9 622 Mbit/s
Slot 5 2.5 Gbit/s Slot 10 AUX

Figure 3-16 Access capacity of the OptiX OSN 1500B (after slot segmentation)

Slots for Interface Boards


„ Service interface boards: slots 14–17

Slots for Processing Boards


„ Service processing board: slots 4–9 and slots 11–13 (before slot
segmentation)
„ Service processing board: slots 1–9 and slots 11–13 (after slot segmentation)
„ CXL board: slots 4–5

Slots for Other Boards


„ Auxiliary interface boards: slot 10
„ Orderwire boards: slot 9 (also for the processing boards)
„ Fan units: slot 20
„ Power interface boards: slots 18–19

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-27


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

Slot Mapping Table


Table 3-17 shows the slot mapping table which associates slots for processing
boards to the slots for its corresponding interface boards.

Table 3-17 Slot mapping table for the OptiX OSN 1500B
Slot for processing boards Slot for corresponding interface boards

Slot 2 Slot 14
Slot 3 Slot 16
Slot 7 Slot 15
Slot 8 Slot 17
Slot 12 Slots 14, 15
Slot 13 Slots 16, 17
Note: The interface boards of the PD3, PL3, SEP, and SPQ4 boards can only be inserted in corresponding
slots in even number.
Slot 12 and slot 7 share slot 15 for interface boards. When the R1PD1 is seated in slot12, the R1PL1 can not
be seated in slot7. On the other side, when the R1PD1 is seated in slot7, the R1PL1 can not be seated in slot12.
Slot 13 and slot 8 share slot 17 for interface boards. When R1PD1 is seated in slot13, R1PL1 can not seated in
slot8.

3.5.3 Boards and the Corresponding Slots


Processing Boards
Table 3-18 associates processing boards to the corresponding slots.

3-28 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

Table 3-18 The relation between processing boards and slots for the OptiX OSN 1500B
Slots and Before slot segmentation After slot
capacity segmentatio
n

Slot 11–slot 13
(1.25 Gbit/s )

(1.25 Gbit/s )
(622 Mbit/s )

(622 Mbit/s )

Slot 1–slot 3
(622 Mbit/s)

(622 Mbit/s)

(2.5 Gbit/s )
(2.5 Gbit/s)

(2.5 Gbit/s)
Slot 11

Slot 12

Slot 13
Slot 6

Slot 7

Slot 8

Slot 9
Boards

N1SF16, - - - - 9 9 9 - -
N1/N2SL16(A),
N1/N2SLQ4,
N1/N2SLD4,
N1/N2SL4,
N1/N2SLQ1,
N1/N2SL1,
N1SLT1 (Note
1)
R1SLD4 - - - - - - - 9 9
R1SL4, 9 9 9 9 - - - 9 9
R1SLQ1,
R1SL1
N1SEP (work - - - - - 9 9 - -
with interface
boards) (Note
2)
N1SEP1 (led - - - - 9 9 9 - -
out from front
panel) (Note 2)
N1/N2SPQ4, - - - - - 9 9 - -
N1PD3, N1PL3
N1PL3A - - - - 9 9 9 - -
N1PQ1, - - - - 9 9 9 - -
N1PQM
R1PD1 9 9 9 - - - - 9 9
R1PL1A, 9 9 9 9 - - - - -
R1PL1B
R1EFT4 9 9 9 9 - - - 9 9
N1EFS4 - - - - 9 9 9 - -
N1/N2EFS0 - - - - - 9 9 - -

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-29


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

Slots and Before slot segmentation After slot


capacity segmentatio
n

Slot 11–slot 13
(1.25 Gbit/s )

(1.25 Gbit/s )
(622 Mbit/s )

(622 Mbit/s )

Slot 1–slot 3
(622 Mbit/s)

(622 Mbit/s)

(2.5 Gbit/s )
(2.5 Gbit/s)

(2.5 Gbit/s)
Slot 11

Slot 12

Slot 13
Slot 6

Slot 7

Slot 8

Slot 9
Boards

N1/N2EGS2, - - - - 9 9 9 - -
N1EGT2,
N2EGR2
N1EFT8 (work - - - - - 9 9 - -
with interface
boards)
N1EFT8 (led - - - - 9 9 9 - -
out from front
panel)
N2EMR0 (work - - - - - 9 9 - -
with interface
boards)
N2EMR0 (led - - - - 9 9 9 - -
out from front
panel)
N1ADL4, - - - - 9 9 9 - -
N1ADQ1
N1IDQ1, - - - - 9 9 9 - -
N1IDL4 (Note
3)
N1MST4 - - - - 9 9 9 - -
N1MR2A - - - - 9 9 9 - -
N1MR2B 9 9 9 9 - - - 9 9
N1MR2C (Note - - - - - - - - -
4)
N1LWX - - - - 9 9 9 - -
N1BA2, - - - - 9 9 9 - -
N1BPA
Note 1: The SLT1 in the OptiX OSN 1500B provides 1–12 optical interfaces.
Note 2: On the T2000, the SEP1 is displayed as SEP1 when led out directly from the front panel, or displayed as SEP when working
with interface boards.
Note 3: The maximum bandwidth at SDH side for the N1ADL4, N1ADQ1, N1IDL4, and N1IDQ1 is 1.25 Gbit/s.
Note 4: The N1MR2C seats in any of slots 14–17.

3-30 Huawei Technologies Proprietary Issue 04 (2007-04-30)


OptiX OSN 3500/2500/1500
Hardware Description Manual 3 Subrack

Interface Boards
Table 3-19 associates interface boards to the corresponding slots.

Table 3-19 The relation between interface boards and slots for the OptiX OSN 1500B
Slots

Slot 14

Slot 15

Slot 16

Slot 17
Boards

N1EU08 9 - 9 -
N1OU08 (LC 9 - 9 -
type)
N2OU08 (SC 9 - 9 -
type)
N1EU04 9 - 9 -
N1MU04 9 - 9 -
N1C34S 9 - 9 -
N1D34S 9 - 9 -
N1D75S 9 9 9 9
N1D12S 9 9 9 9
N1D12B 9 9 9 9
N1ETF8 9 - 9 -
N1EFF8 9 - 9 -
N1ETS8 9 - - -
N1TSB8 9 - - -
N1TSB4 9 - - -

Other Boards
Table 3-20 associates cross-connect boards, SCC boards, and auxiliary interface
boards to the corresponding slots.

Issue 04 (2007-04-30) Huawei Technologies Proprietary 3-31


OptiX OSN 3500/2500/1500
3 Subrack Hardware Description Manual

Table 3-20 The relation between other boards and slots for the OptiX OSN 1500B
Slots

Slot 101–slot 102


Slot 18, slot 19
Slot 4–slot 5

Slot 10

Slot 20

Slot 50
Slot 9
Boards

Q1CXL1/4/16, 9 - - - - - -
Q2CXL1/4/16
(physical board)
(Note 1)
GSCC, SCC Slot 82, 83 - - - - - -
(logical board)
CXL, ECXL Slot 80, 81 - - - - - -
(Logical board)
Q1SL1/4/16 9 - - - - - -
(logical board)
R1EOW - 9 - - - - -
R1AUX, R2AUX - - 9 - - - -
R1PIU - - - 9 - - -
R1FAN - - - - 9 - -
N1COA, 61COA, - - - - - - 9
62COA (Note 2)
CAU - - - - - 9 -
Note 1: The CXL is a line, system control, cross-connect and timing board of the OptiX OSN 1500B. It seats
in slot 4 and slot 5. On the T2000, it is displayed as three board types: CXL, SCC and SL1/4/16, respectively
occupying the logic slots 80–81, 82–83 and 4–5.
Note 2: The corresponding slots for the N1COA, 61COA, and 62COA are logical slots, not physical slots.

3.5.4 Technical Parameters


Table 3-21 lists the technical parameters of the OptiX OSN 1500B.

Table 3-21 Technical parameters of the OptiX OSN 1500B


Dimensions 221 mm (H) x 444 mm (W) x 263 mm (D)
Weight 9 kg (including backboard, 2 pieces PIU and fan)

3-32 Huawei Technologies Proprietary Issue 04 (2007-04-30)