1 PARTS DESCRIPTION

Connection
Terminal
Wire Hole ② Monitor Jack
(Only for Receiver)

DIGITAL ACTIVE INFRARED SENSOR ① LED


③ Obscuration Time
Adjustment
(Only for Receiver)

INSTRUCTION MANUAL
Tamper
SBT - 30S
Vertical
SBT - 40S Adjustment
Screw Viewfinder
SBT - 60S
LENS
SBT - 80S Horizontal Angle
Adjustment Dial
SBT-100S Cover Lock
Screw
COVER MAIN BODY

2 SUGGESTIONS FOR INSTALLATION 1 ① LED

GOOD LEVEL ALARM POWER

RECEIVER TRANSMITTER
●GOOD ( Green ) ●POWER ( Green )
On when optically aligned
Off when optically not aligned
●LEVEL ( Red )
Intensity varies with signal
●ALARM
Ensure the sensors line of sight is Ensure the sensors are Ensure strong sunlight or car Alarm indication lamp
free from any false alarm sources mounted on a stable and headlights do not shine directly ② Monitor jack: Should be used for making the optimum optical axis adjustment
such as bushes, trees, etc. ( Pay firm fixing. on to the receiver. (Within ±2°
attention to these as they may ( Refer to ' how to use the monitor jack' )
from the optical axis is not
change seasonally.) recommended.) ③ Obscuration time adjustment: To be used for setting the obscuration time
( Refer to ' adjustment of obscuration time ' )

3 SUGGESTIONS FOR INSTALLATION 2

Transmitter Receiver
Note that here the protection distances Height of installation and Direction of installation
refers to the sheet below. protection distance Receiver
Vertically 20°

Transmitter
Protection Spread of
Spread of Beam

Model
Distance Beam 33mm In case of jump phenomenon, as shown ×
14mm
SBT-30S 30m 0.9m section in the above, change the disposition
of transmitter and receiver to the following
SBT-40S 40m 1.2m manner shown ◎ section.
SBT-60S 60m 1.8m Horizontally 180° Transmitter Transmitter
0.7 33mm
SBT-80S 80m 2.4m ~
1.0m Receiver
SBT-100S 100m 3.0m Protection Distance Because angle of reflection mirror is adjustable
in ± 90°horizontally and ± 10°vertically, the
unit can be installed in various directions. Receiver

4 INSTALLATION
WALL MOUNT POLE MOUNT

1. Loosen screw holding cover and 2. Attach the mounting pattern 3. Break knock-out and pull wire
1. Pull the wire through the
remove the cover. paper to the wall, mark the through.
wire hole of the pole.
installation holes, and make
guide holes.
knock-out

φ 38mm ~φ 50mm

2. Attach the bracket to the pole with the pole holder.

Bracket Pole holder Pole cover

4. Attach the unit to the wall. 5. Connect wires to the terminal. 6. Make the optimum optical adjustment
as per section 5 and confirm system
operation before replacing covers.

TERMINAL CONFIGURATION Pole mount back-to-back


Each bracket to be reversely attached.
POWER ALARM TAMPER

1 2 3 4 5 6 7
Wiring distance
RECEIVER
Model SBT-30S SBT-40S SBT-60S SBT-80/100S
Voltage POWER FREE TAMPER
Wire 12V 24V 12V 24V 12V 24V 12V 24V
diameter
0.3mm (φ
f
2
0.6) 280m 2400m 270m 2300m 250m 2100m 190m 1600m
0.5mm (φ
2
f0.8) 500m 4400m 477m 4200m 430m 3800m 350m 3000m
0.75mm (φ
2
f1.0) 780m 7000m 747m 6700m 680m 6100m 546m 4900m 1 2 3 4 5 6 7

1.25mm (φ
2
f1.2) 1120m 10000m 1074m 9570m 980m 8700m 784m 7000m TRANSMITTER
5 ADJUSTMENT OF OPTICAL AXIS
It is important to ensure correct optical alignment between the
transmitter and receiver for proper operation.
HOW TO USE THE MONITOR JACK

The best adjustment of optical axis can be done by reading the


1. Turn on the power supply after uninstallation. 3. Adjust the angle of the lens via the Horizontal angle
output voltage of the monitor jack.
Place the viewfinder on either right or left adjustment and the Vertical adjustment screw so that
hand side of the lens whichever makes the sensor can be seen in the center of the Viewfinder.
easier viewing. This adjustment is carried out on both the Transmitter
Viewfinder and Receiver. Confirm after adjustment that the green
GOOD LED is on, otherwise alignment should be
readjusted. The red LEVEL LED lamp will be brighter
dependent on higher signal levels.

Vertical adjustment

Monitor Jack
to raise to lower
(loosen) (tighten) 1. Insert the meter pins into the monitor jack.
2. Look through the viewfinder as shown below.
(Pay attention to the polarity because of DC voltage)
2. a) Adjust the horizontal adjustment until the output is at a maximum.
b) Adjust the vertical adjustment screw to obtain best signal.
(Do not interrupt beam by hands during the adjustment)
NOTE: After completion of optical adjustment, ensure 3. The following minimum voltages should be obtained to ensure best performance.
that both filters on the receiver are replaced 2.3V for all of the SBT-XXS series. If this is not obtained then the transmitter and
to their original position behind the mirrors. receiver should be re-aligned.
1 0 cm NOTE: If the sensors are too close together then the signal level saturates and
the IR beam may be shut-down. This is normal and will only be achieved
during bench testing. Signal levels are restored under normal operation
distances.

6 ADJUSTMENT OF OBSCURATION

Set the obscuration time of the receiver by adjusting the obscuration time control
to the required setting according to the sketch beside. The obscuration time should
2
3
4
Scale 1 Scale 2 Scale 3 Scale 4

be set lower to detect faster moving targets, however care should be taken to note
the environmental conditions as the obscuration time should be set higher to ignore 1 5
conditions where there are a lot of birds or wind blown material.
Caution: Obscuration time settings exceeding 70msec (exceeding a setting of 1) do fast running at full walking with quick normal walking slow action
not comply with the requirements in UL639, Instrusion Detection Units. Obscuration time control
speed(6.9m/s) steps(1.2m/s) (0.7m/s) (0.3~0.5m/s)

7 CONFIRMATION OF OPERATION

After completion of the installation, confirm correct operation by suitable walk test. Refer to the following LED
indications during the walk test. Confirm tamper operation prior to replacing covers. Confirm system operation
Transmitter
Conditions
Transmitting
Watching
Indication
Green LED is on
Alarm indicator is off
with covers replaced. Receiver
Alarm Alarm indicator is on

NOTE: Conduct a Walk Test at least once a year

8 TROUBLE SHOOTING GUIDE

Q Symptom Possible cause A Remedy


9 SPECIFICATION

Indication lamp of Transmitter


Improper voltage of power supply Check power supply and wiring
does not light.
Power supply indication Lamp Model
Improper voltage of power supply Check power supply and wiring SBT-30S SBT-40S SBT-60S SBT-80S SBT-100S
of Receiver does not light.
Protection range(outdoor) 5-30m 30-40m 40-60m 60-80m 80-100m
① Infrared beam from Transmitter is ① Remove the reflecting object or
reflected on another object and change the place for installation Distance allowance 350m 450m 650m 900m 1100m
Alarm indication lamp does not sent into the Receiver. and the optical axis direction.
Infrared beam 2 beams
light even when the beams are ② Two beams are not intercepted at ② Check two beams to intercept
intercepted. the same time. at the same time. Detection system 2 beams simultaneous cut-off detection
③ Shorter o bscuration t ime t han t hat ③ Adjust obscuration time setting
set on the obscuration control. to be shorter. Light source Infrared LED

① Broken wires or short on the ① Check the wiring. Response time 50-700 msec
Although alarm LED lights signal wires. Alarm output Relay contact, form 'C' contact rating 30V AC, DC 0.5A Max.
when the beams are ② Melted bridge on the signal ② It needs to be repaired.
intercepted, alarm does
not ring. connection Power required DC 10.5-28V
(Wrong current on the signal wires)
Power consumption 40mA max 45mA max 55mA max 65mA max 65mA max
① Inadequate optical axis. ① Readjust the optical axis. DC12-28V DC12-28V DC12-28V DC12-28V DC12-28V
② Shading objects between the ② Remove the shading objects.
Alarm LED on the Receiver
Transmitter and the Receiver. Temperature range -25℃~+55℃
does not turn off.
③ Dirty cover or dirty reflection mirror ③ Clean optics with soft cloth.
of the T ransmitter and/or Receiver. Tamper output Normally closed voltage free contacts 30V DC, 0.5 A Max.
Optical axis horizontal adjust ±90°
① Bad wiring connection. ① Check the wiring connection.
② Change of supply voltage. ② Check the voltage (for stabilized Optical axis vertical adjust ±10°
supply voltage.)
Collimator Finder ( peep window )
③ Shading objects moving by wind ③ Remove the shading objects or
between the Transitter and the change the place for installation. Measure for moisture/frost Slit type cover, heater option
Intermittent alarm. Receiver.
④ Unstable installation of the sensor ④ Fix steadily. Other additional function Sensitivity monitoring output terminal. Ok monitoring
unit.
Place for installation Indoor or Outdoor
⑤ Incomplete optical axis adjustment. ⑤ Readjust the optical axis.
⑥ Birds and other large flying objects ⑥ Readjust the obscuration time Weight 600g ( Transmitter and Receiver )
intercept the beam. to be longer or reposition.

10
OUTLINE DIMENSION
2- 4.0mm
SHENZHEN SUNWAVE ELECTRONICS CO., LTD.
2- 5.0mm

No.21 Plant, Da Wei Industrial Zone, Huang Ge Keng,


171
146

Heng Gang Town, Shenzhen


CHINA
TEL: +86-755-8998-3101 FAX: +86-755-8998-3102
38~50mm http://www.sunwave.cc