NAME :. YR & SEC.

: DATE : RATING______
Activity # 8
COMPARATIVE CHARTS FOR STEAM POWER CYCLES
JUST A REMINDER …… Can I now identify the concepts of the following:

 What is a Reheat, Reheat- Regenerative & Reheat-Regenerative Cycles?


 If geothermal power plant is included, will the process & values of thermodynamics at the TS
diagram different from the other cycle?
 How can relate the values from the comparative tables when preferred to be used as a steam
power cycle for the Power Generating Plant?
 If you are now ready, fill the value/s corresponding to the description in the comparative table
below based from the computed values for the analysis of other steam power cycles for steam
power generating plant?

Comparative Charts for Different Steam Power Cycle

1
No. DESCRIPTION REHEAT CYCLE REGENERATIVE CYCLE REHEAT-REGENERATIVE

1 THERMODYNAMICS PROPERTIES:

@ different state points in the cycle:

1 3578.6 kJ/kg 3578.6 kJ/kg 3578.6 kJ/kg

2 2904.5kJ/kg 2884.26 kJ/kg 2884.26 kJ/kg

2’ Not applicable Not applicable 3517.75 kJ/kg

3 3517.3 kJ/kg 2291.6 kj/kg 2657.396 kj/kg


4 2665.9 kJ/kg 417.46 kJ/kg 417.46 kJ/kg

5 417.46 kJ/kg 420.49 kJ/kg 420.49 kJ/kg

6 420.49kJ/kg 1008.4 kJ/kg 1008.4 kJ/kg

7 NA 1041.24 kJ/kg 1041.24 kJ/kg

8 NA N/A N/A

Others, if there is/are: N/A N/A

9 NA N/A N/A

10 NA N/A N/A

ANALYSIS OF THE CYCLE:

Heat added to the boiler 3158.11 kJ/kg 62,810.89 kW 62,810.89 kW

Turbine Work 38.522 MW 27.67 MW 32.82 MW

Heat Rejected @ Condenser 2248.44 kJ/kg 36.04 MW 43.07 MW

Pump Work: Wp 76.50 kW 887.48 kW 887.48 kW

Wp after the condenser NA NA NA

Wp before entering the boiler NA NA NA

Work Net 38.446 MW 26,783.52 kW 31,931,69kW

Thermal Efficiency 48% 42.6% 50.8%

Steam Rate 0.0936 kg steam/kW-hr 0.13 kg steam / kW - hr 0.11 kg steam / kW - hr

QUESTIONS: Write your answer below the questions & upload your answer in your individual goggle shared drive.

1. Based from the comparative charts with values at different state points and analysis of the steam power cycle, answer the following:
a. Which of the state points show changes in the values?

b. What contribute to the increase or decrease, or change in such specific thermodynamic properties?

2. If given an opportunity to calculate the performance of the steam generator and prime movers such as steam turbine & steam engine,
are computed values enough to compute such performances? Justify your answer.

3. Is the cycle for the geothermal power plant generation different from the above mentioned cycles? Explain.

4. Show the TS diagram of the different cycles for geothermal, rankine, reheat, regenerative & reheat-regenerative cycles.

5. Based from the cycle, write your observations or reactions for such cycle that will bbe used for a “ Power Plant Generation System”.

You might also like