Glazed Elements - Fenestration Performance Requirements 1-3-2014 v1

Thermal Bridges: for all new air conditioned buildings,


Plot No. IC3-R-35, INTERNATIONAL CITY 3, DUBAI - UAE.
Glazed Elements - Fenestration Performance Light Thermal Bridges, such as connection points between concrete
Thermal Shading or steel beams, external walls and columns and around doors
Project Proposed 2B+G+8F+RF RETAIL & RESIDENTIAL BUILDING Requirements as per Green Building Regulations & Transmittance -
Transmittance -U Coefficient - SC and windows, which enable the flow of heat from outide into the
Specifications LT
Consultant CAPITAL ENGINEERING CONSULTANCY W/m2 K building, must be eliminated or insulated to reduce the amount
of heat transfer
(1) If percentage of total area of external walls that let
Glazed Elements - Fenestration Percentage Orientation of Glazed Facades
lights to the external wall area is:
Wall Glazing Elements Percentage to the Glazing Portion of a Roof Percentage to the 1-1 Equal or less than 40% 2.10 (max) 0.40 (max) 0.25 (min) Perdominately North
External Wall Area Total Roof Area 1-2 Between 40% - 60% 1.90 (max) 0.32 (max) 0.10 (min) Orientation Percentage Is:
57%
Total Glass Area 1373.57 m2 Total Glass Area m2 1-3 Equal or greater than 60% 1.90 (max) 0.25 (max) 0.10 (min)
Total External wall (2) For shopfronts and showrooms, other than those at
5357.70 m2 Total Roof Area 532.00 m2 1.90 (max) 0.76 (max)
Area ground floor level:
(3) If percentage of glazing portion of a roof to the roof
26% area is: As Per Regulation (304.04)
3-1 Equal or less than 10% 1.90 (max) 0.32 (max) 0.40 (min)
3-2 Greater than 10% 1.90 (max) 0.25 (max) 0.30 (min)

Hide Empty Rows

No. of Windows on the Exposed Orientation


Glazed Elements Thermal Light
Height Width Item Area Shading
Perdominately North Orientation No. of Glass Layers Transmittance - U Transmittance - Color Type Note
SE S SW W H Coefficient - SC
LT
Reference Name/No. m m m2 NW N NE E Horizontal W/m2 K
W-01 1.10 2.30 2.53 1.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
W-02 1.10 1.10 1.21 24.00 7.00 1.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
W-04 1.20 0.60 0.72 14.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
W-05 1.10 1.70 1.87 7.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
W-06 1.20 1.00 1.20 8.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
CWG-1+SLD-1+GD-2 2.40 8.25 19.80 2.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
CWG-02 2.40 14.86 35.66 1.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
CWG-03 2.40 11.50 27.60 1.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
CWG-04 2.40 8.26 19.82 1.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
CWG-05 2.40 7.40 17.76 1.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
CWG-6+SLD-1+GD-2 2.40 8.90 21.36 1.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
CWG-07 2.40 2.80 6.72 7.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
CWG-08 2.40 1.58 3.79 7.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
CWG-09 2.40 2.80 6.72 2.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
CWG-10 2.40 17.00 40.80 1.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
CWG-11 2.40 18.60 44.64 6.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
SD-01 2.40 2.00 4.80 14.00 7.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
SD-02 2.40 2.40 5.76 21.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
SD-03 2.40 3.00 7.20 14.00 2.00 7.00 30.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
SD-04 2.40 5.70 13.68 7.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
SD-05 2.40 3.50 8.40 2.00 1.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
SD-06 2.40 7.40 17.76 1.00 2.00 2.10 0.28 0.25 M DOUBLE GLAZED THERMAL BREAK
Total Glazed Area at the Corresponding Orintation (m2): 373.95 217.27 186.18 322.08 274.09

Wall Consultant Comments:


Height Width Total Area Light Reflective
No.
Reference Name/No. m m m2 Value LRV (%)
Ground Floor 5.10 166.00 1.00 846.60 45.00 Light Colors on the Outside of Buildings: For all new buildings, at least 75% of the area
1st-7th Typical Floor 3.30 173.00 7.00 3996.30 45.00 of externally painted walls must have a minimum Light Reflective (LRV) Value of 45%
8th Floor 3.30 156.00 1.00 514.80 45.00

Roof
Length Width Total Area Roof Solar Reflective Urban Heat Island Effect: All opaque external roofing surfaces must comply with a
Type of Roof
Reference Name/No. m m m2 Index - SRI minimum Roof Solar Reflective Index (SRI) Value according to table below for a minimum
Roof 1.00 532.00 532.00 Flat & or Low 78.00 of 75% of the roof area:
Steep Sloped Enter SRI Value Type of Roof Min. Roof SRI
Steep Sloped Roofs (slopes steeper than
Steep Sloped Enter SRI Value ≥ 29.00
1:6)
Flat and Low Sloped Roofs ≥ 78.00