FS-T1 (P) /T2 (P) /T0: One-Touch Calibration Fiberoptic Sensor
FS-T1 (P) /T2 (P) /T0: One-Touch Calibration Fiberoptic Sensor
FS-T1 (P) /T2 (P) /T0: One-Touch Calibration Fiberoptic Sensor
NPN / PNP
1. Fully-automatic calibration
• Easy calibration
You can complete calibration simply by
One-touch Calibration pressing a button as you pass a target SET
3. Simple wiring
• The expansion unit needs no power supply
cable.
• Up to 16 expansion units can be connected
to a single main unit.
WARNING
• The FS-T1(P)/T2(P) are intended for target detection. Do not use these
products in a safety circuit for protecting the human body.
• The FS-T1(P)/T2(P) are not explosion-proof. Do not use these products
A "P" following the model number indicates PNP-output type. in an atmosphere where inflammable gas, liquid or powder is present.
SPECIFICATIONS CONNECTIONS
Model NPN output FS-T1 FS-T2 FS-T0 1. The response speed var- NPN Brown
1.
ies depending on the Black 100 mA max.
PNP output FS-T1P FS-T2P — number of units con- Load
Light source Red LED nected. 50 mA max. 12 to 24 VDC
Orange
Response time 250 µs 410 µs to1 ms 1. 2. There is no control Load
output cable for the FS-
Operation mode LIGHT ON/DARK ON (switch-selectable) Blue
T0. Control output for the
Indicators Output indicator: Red LED, Stable operation indicator: Green LED, FS-T0 is sent from the Pink External calibration
Calibration indicator: Yellow LED FS-R0. input
3. Stability output is only • To connect the FS-T1 to a voltage input device, provide a 4.7 kΩ resistor
Timer function ON-delay: 40 ms, OFF-delay: 40 ms, Timer OFF (switch-selectable)
provided by the FS-T1(P). between the brown and black cables.
External calibration Non-voltage input (contact, solid-state) Stability output for the FS- • When the external calibration input is not used, cut the pink cable at the
input signal T2(P)/T0 is sent from the root, or connect this cable to the positive terminal of the power supply.
Control output NPN or PNP open-collector 100 mA max. (40 V max.) FS-T1(P)/R0. • When the stability output is not used, cut the orange cable at the root, or
4. Power for the FS-T2(P)/
Output
Residual voltage: 1 V max. 2. connect this cable to the 0 V terminal of the power supply.
T0 is supplied through the 1. The FS-T2 has the black cable only.
Stability output NPN or PNP open-collector 50 mA max. (40 V max.) 3. FS-T1(P)/R0.
Residual voltage: 1 V max. 5. When several units are Brown
connected, the ambient PNP 1.
Protection circuit Reverse polarity protection, Over-current protection, Serge absorber Black 100 mA max.
temperature requirement
Power supply voltage 12 to 24 VDC ±10%, Ripple (P-P) 10% max.4. varies depending on the
Load
50 mA max. 12 to 24 VDC
Current consumption 35 mA max. total number of units con- Orange
nected. Load
Ambient illumination Candescent lamp: 10,000 lx max. Sunlight: 20,000 lx max.
When 3 to 10 units are Blue
Ambient temperature -10 to +55°C 5. connected: -10 to +50°C
Relative humidity 35 to 85% When 11 to 16 units are Pink External calibration
connected: -10 to +45°C input
Vibration 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z • To connect the FS-T1P to a voltage input device, provide a 4.7 kΩ resistor
directions for two hours When connecting several
units, be sure to mount between the blue and black or orange cables.
Shock immunity 500 m/s2 {Approx. 50 G} in X, Y and Z directions, three times each the units to a metallic DIN • When the external calibration input is not used, cut the pink cable at the
Housing material Body/Cover: Polycarbonate rail. Make sure that the root, or connect this cable to the 0 V terminal of the power supply.
output current does not • When the stability output is not used, cut the orange cable at the root, or
Weight Approx. 75 g Approx. 40 g Approx. 20 g connect this cable to the positive terminal of the power supply.
exceed 20 mA.
(including 2 m cable) 1. The FS-T2P has the black cable only.
SETTING SENSITIVITY
Select the sensitivity setting procedure according to the
target condition.
For sensitivity adjustment using a moving target For sensitivity adjustment using an external signal
● Fully-automatic Calibration ● External Calibration Function [For FS-T1(P)/T2(P) only]
1. Pass a target through the optical 1. Set the key-protection switch to LOCK. [Setting this switch to LOCK
axis while pressing the SET disables sensitivity adjustment with the SET button. (Key-protection)]
button.
2. Connect the pink cable to a switch or PLC.
Pass 2. Confirm that the calibration
target
indicator (yellow LED) flashes. NPN PNP
Blue 0V Blue 0V
Pink
To detect a minute difference Pink
Contact or
solid-state input Contact or solid state input
● Two-point Calibration
1. With a target in place, press the
The minimum input time is 20 ms.
SET button and release it.
The calibration indicator (yellow
3. Activate the external calibration input using the SET button.
LED) lights.
(You can perform all the setting procedures described on the left.)
2. With the target removed, press
While the external calibration input is activated, the stability output
the SET button and release it.
remains on.
The calibration indicator (yellow
LED) goes off.
CUE: Calibration input during detection
You can re-adjust sensitivity during detection without stopping the
line operation.
For target positioning The sensor continues operation with the previous sensitivity setting
● Positioning Calibration until sensitivity readjustment is completed.
1. With no target, press the SET
button and release it.
The calibration indicator (yellow CUE: External calibration with several units
LED) lights. When several units are connected, the sensitivity of all the FS-T2(P)
expansion units can be simultaneously set using the external
2. Place a target in the position calibration input through the FS-T1(P) main unit.
where it is to be stopped. SET
You can select a unit to be externally calibrated by setting its key-
At least protection switch to the LOCK position.
3 seconds
3. Press the SET button and wait for
the calibration indicator to flash.
CUE: When the sensitivity difference is insufficient:
4. Release the SET button. After calibration is completed, the stable operation indicator (green
LED) flashes if the sensitivity difference is insufficient. (When the
external calibration function is used, the stability output remains on
For stable detection unaffected by dust for another 3 seconds after the calibration input is turned off.)
● Maximum Sensitivity Setting Sensitivity is set and registered even when the sensitivity
1. Under the following conditions Note difference is insufficient. Be sure to confirm that detection
press the SET button until the is properly performed.
SET
calibration indicator (yellow LED)
At least flashes.
3 seconds
2
MOUNTING AMPLIFIER
■ Mounting/Detaching the amplifier to/from a DIN rail or the ■ Side mounting
mounting bracket. Using the side holes of the supplied mounting bracket, fix the amplifier
Hook the claw located at the amplifier cable side onto the DIN rail, and with the screws. [For FS-T1(P) only]
then hook the front side claw to the rail while pressing the amplifier
forward. To detach the amplifier, unhook the front claw by lifting the
amplifier front side while pressing it forward. M3 screw
Mounting Detaching
Align the front claws of the amplifiers and Main unit 1. Expansion End unit
unit 2. (Included with
push the amplifiers together until they expansion unit)
click.
Adaptor A
FU-32/35FA/4F/43/63/63T/66/78/91/93
(OP26500)
For 1.3 mm diameter
• To connect a fiber unit with a small diameter, use the adaptor Adaptor B
FU-31/37/38/38V/48/59/68/75F/79/95
included with the FU series. (OP26501)
For 1 mm diameter
1
Attach the adaptor to the fiber unit,
• To connect the coaxial reflective type fiber unit to the amplifier,
fully insert the adaptor into the
connect the single-core fiber to the transmitter side, and connect the
mounting holes of the amplifier, and
multiple-core fiber to the receiver side.
then lift the quick-release lever.
(Connect the fibers according to the marking on the amplifier lateral
2 side.)
If the fiber unit is improperly
Note
connected, the sensor cannot Transmitter
meet the specifications. Receiver
Multiple-core Single-core
When several units are connected, the FS-T series alternates the light
emission timing with up to four sensors so that the adjacent sensors’
light beams do not affect detection.
• The FS-T series can be used together with the FS-M series (manual-
calibration type).
3
HINTS ON CORRECT USE I/O CIRCUIT
• To extend the cable length, use a cable with at least a NPN PNP
0.3 mm2 cross-section area. Limit the length of cable FS-T1 FS-T1P
extension to no more than 100 m. (To connect several Brown Brown
units, contact Keyence for further information.) 100 mA max.
Photoelectric sensor
Photoelectric sensor
protection circuit
Black
protection circuit
Overcurrent
Load
Overcurrent
(Control output)
main circuit
main circuit
50 mA max. Black 12 to 24
1. Load
Orange 12 to 24 VDC
• If the amplifier cable is placed together with power lines (Stability output)
Load
VDC Orange
1.
Load
or high-voltage lines in the same conduit, detection error Blue Blue
may occur due to noise interference, or the sensor may Input circuit
Pink Input circuit
Pink
be damaged. Isolate the amplifier cable from these lines. (External calibration) (External calibration)
1. When the stability output is not used, cut the orange 1. When the stability output is not used, cut the orange cable
• When using a commercially available switching regulator, cable at the base, or connect this cable to the 0 V at the base, or connect this cable to the positive terminal
terminal of the power supply. of the power supply.
ground the F.G. terminal and ground terminal.
FS-T2 FS-T2P
• Do not use the FS-T series outdoors, or in a place where
12 to 24 VDC
extraneous light can enter the light receiving surface
Photoelectric sensor
Photoelectric sensor
100mA max.
protection circuit
protection circuit
directly.
Overcurrent
main circuit
Overcurrent
main circuit
Load 5 to
Black
40 VDC
(Control output)
11 kΩ Pink
0V
Contact or 0V
solid-state input
DIMENSIONS
FS-T1(P) When the mounting bracket End unit
[included in the FS-T1(P)] is attached: [Included in the FS-T2(P)]
1.1
Brown/Blue: 0.34 mm2
*ø3.9 5-core x
Black/Orange/Pink: 0.18 mm2
Cable length: 2 m 6
9 36.5
(Maximum 3.8 16
when the DIN-rail mounting 135° 8
cover is
1.1 6 max. DIN-rail mounting
opened) 10.5
78 12
min.
4
13.3 25.4
(33) 28.5 18.5 2 x ø3.4 (22.6) 20.8
Spot facing: ø6,
(12.5) 2.7 (d)
6.7 2 x (4.4 x 3.4)
Spot facing: ø7, 4 (d) 9.2 35.4
8.4 35.4 12 53.8
min. 9
53.5
15
31
FS-T2(P) ø2.6 single-core FS-T0
x 0.34 mm2
Cable length: 2 m
9 9
(33)28.5 (33)28.5
(12.5)
6.7 6.7
8.4 35.4 11 8.4 35.4 Worldwide Headquarters
53.5
min.
53.5 3.6
KEYENCE CORPORATION
1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku,
Osaka, 533, Japan
When several units are connected: PHONE: 81-6-379-2211 FAX: 81-6-379-2131