Commercial Retail Shops: Beauty, Shoe Repair, Drug

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

Commercial

RETAIL SHOPS
Beauty, Shoe Repair, Drug

DRUGSTORE
PLAN DIMENSIONS
0. 8'-6" 111 . 21'-6"
b. 32'6" (wall g. 14'-6"
cases, counter, h. 6'-9" to T-0"
stepped count- I. 5'-9" to 8'-0"
SODA BOOTHS e r) I. 4'-6" to 5'-8"
C . 10'-6" (varies with
d. 9'-0" counter depth)
tr . 13' 0"

SODA BOOTHS
a. l'-4" C . 4'-8" min .
b. 2'-0" d. 3'-6" min .

Fig. 22 Drugstore.

DRUGSTORES

Today's drugstore is no longer the small neigh-


borhood pharmacy or "wet" store that included
a soda fountain with tables . It is now either a
small "dry" store, primarily handling prescrip-
tions, sundries, and cosmetics, or the large
variety type of store, very often part of a chain
operation with certain departments leased out .
In addition to the departments already men-
tioned for the small store, it may have a com-
plete luncheonette and departments for tobac-
co, film, greeting cards, books, and certain
household items typical of the variety store .
The larger store very often is part of a shopping
center complex .
Storefronts are simple, generally the open
or see-through type, with shallow display win-
dows with high platforms.
Interior must be well organized and grouped
or departmentalized . The prescription depart-
ment usually is in the rear of the store, with a
small seating or waiting area . This is similar
to typical department store selling, which
forces the prescription customer through the
entire store and past the impulse items . Very
often the tobacco section will also be located
in the rear, for the same reason, though some
operations prefer to handle tobacco at the
cashier along with film . The luncheonette nor-
mally is at the front, as is the cosmetics depart- Fig. 23 Pharmacy area of drugstore.
ment, with drugs and sundries centered, and
the book department and telephones again fav-
ored in the rear .
Large operations will have several controlled
check-out counters at the front, with separate
cash registers at the pharmacy and lunch-
eonette .

745
Commercial

RETAIL SHOPS
Drug ; Liquor
The only departments requiring or using zoned and cold well refrigeration . Appearance- Shopping Center
counter service are prescriptions, cosmetics, wise, the shelving will basically look as it does - Advantages Heavy traffic locations . Good
tobacco, film, and radios . All other selling is presently, but each shelf will have temperature parking facilities .
from open displays, gondolas, and wall shelv- control as required to hold each category of - Disadvantages Mostly female traffic. Dis-
ing, usually continuous for flexibility identical merchandise at a correct holding temperature. traction of other types of stores .
to that used for supermarkets and with a cur- Walk-in coolers will be eliminated as s means
tain wall and continuous light cornice et the top of refrigeration. Highway Location
of the shelving . One example of the usage of the cold-wall - Advantages Customer convenience . Heavy
If the prescription and pharmacy work area method is as follows : 99 percent of every liquor automobile traffic.
is elevated one or two steps above the main store in the United States today has a partition " Disadvantages Not easy to "stop" cus-
floor, it provides a better view and control of wall separating the back room from the sales tomers . Need for extensive parking facilities .
the entire store. The layout and operation of area, and in almost every case the cooler is As mentioned above, there are opportunities
the prescription department varies with the either in front of this partition or the partition is to do business regardless of the location .
individual pharmacist . The work area is divided built flush with the front of the cooler, with the
into a wet and dry ores with a worktable, stain. cold-wall idea, when the partition is built. Cold
Considerations in Liquor Store Design
less-steel sink with hot and cold water,and a re- panels will be built right into the well with up-
frigerator . In addition to bottle end container rights placed every four feet for adjustable Among the positive marketing trends that are
storage, generally under the workbench, space shelving . All the can beer and beverages can be affecting liquor store design today are the fol-
is required for prescription files, current and merchandised this way, for combination case lowing :
pest . Keeping good records is mandatory by beer, can beer, and beverage merchandising . 1 . The change in buying trends of the con-
law (Fig . 23). The zoned refrigeration idea will be used so sumer public
that case beer can be stacked 2 or 3 cases deep 2. The new drinking sophistication of con-
and with adjustable shelves for loose merchan- sumers
dise . This method can be applied to any length 3. The emergence of women as liquor store
and width of floor apace required, This same customers
idea will be used to encompass the wine wall 4. The home entertainment boom
shelving . The shelf merchandise will maintain 5 . The constant flow of new brands, new
By A. PETER FLORIO Designer-Consultant a temperature range of 37' to 61 ' which can be products, new sizes entering the market to
adjusted to hold et a preselected temperature, most the new demands of consumers
and percentage of humidity to properly contain There are also some negative trends, and
LIQUOR STORES the product.
The same method of zoned refrigeration will
stores must be designed to cope with them .
They are:
The liquor store will consist of many ideas such be used on all gondolas that will be used to 1 . The shortage of experienced personnel
as : merchandise estate end chateau bottling of 2. The high cost of overhead end daily opera-
1 . Zoned and cold wall refrigeration wine ; cordials and liqueurs (that can be held in tion
2. Perpetual inventory systems a frozen or refrigerated state, thereby offering 3. Extreme price competition in many sec-
3. Refrigerated gondolas more true flavor and taste than is now possi- tions of the country
4. Electronicair filter system to remove ble) ; gourmet foods and can beer . 4. Pilferage problems in some city areas
dust and dirt from sales area It will have an electronic pilferage detection 5. Regulations, regulations, regulations
5. Automatic check-out systems system such as the sensormatic detection sys- In order to properly lay out and design a
6. End of pilferage tem which uses a sensitized dot in the price tag liquor operation, the following points must be
7 . New approaches to exterior store design or sticker . It is almost impossible to find the covered in order to achieve the utmost efficien-
New product ideas such as : dot without special equipment. cy, flexibility, economy of operation, and profit :
1. Frozen and refrigerated cordials, liqueurs If the package or article is properly checked 1 . Location analysis
2 . Complete lines of powdered cocktails, out through a cashier, the dot is desensi- 2. Structural arrangement
mixed drinks tized by equipment under the counter. If the 3. Liquor merchandising "problem" areas
The rapidly growing "spendable income" of shoplifter conceals the package or article and 4 . Product placement
the American public is the single largest factor, gets by the cashier, the dot continues to give 5 . Check-out system
for the perpetual stream of new products and off electronic signals that are picked up by a 6. Traffic control
new packaging that enters the retail liquor in- sensitive detector at the exit, notifying security 7 . Financing
dustry constantly is slowly bringing about officers that a theft is taking place. 8 . Interior designing
new ideas in product development and prod- 9. Signs and display techniques
uct presentation which, in turn, create new 10 . Refrigeration requirements
Location Analysis 11 . Electrical requirements
demands and new requirements for equipment
manufacturers and store designers . Downtown City Location 12 . Plumbing requirements
All these new items create new problems of - Advantages Pedestrian traffic is principal 13 . Air conditioning requirements
merchandising techniques . In conjunction with advantage. Also availability of business mar- 14 . Heating requirements
these new products, the percentage of women ket. See Fig. 24 for some possible layouts .
customers is ever increasing . Within the next " Disadvantages High rentals, competition,
10 years, women will outnumber men custom- lack of parking facilities .
Interior Design
ers, as liquor in one form or another is becom-
ing more and more of a staple item in the aver- The basic plan and operation of a liquor store is
age American home . Suburban that of self-service, i .e ., open shelving, but with
Women shoppers are more demanding, more - Advantages Upper income customers . a sufficient number of clerks available to help
critical, and more susceptible to a properly Considerable home entertainment. Good gift customers. Women are doing more shopping
designed merchandising layout in an attractive market . in liquor stores, particularly the neighborhood
well-lighted store, and they are bigger impulse " Disadvantages Lack of street traffic. High store, and are impulse buyers-they need and
item buyers than men . (And they also control delivery costs . expect assistance in making selections .
most of the family money.) Storefronts are usually the completely open,
The selling area will either be covered with Industrial see-through type without any window backs
carpeting, which will be specially designed - Advantages Excellent customer pool . since many states require the entire interior
with a foam backing that will eliminate a large Both business and labor. of the store to be visible from the street . Be-
percentage of bottle breakage in the sales area, - Disadvantages Peak selling periods. Pay fore starting any plans or sketches, check
or floor tile that will never need polishing . days, after working hours . Need for lots of carefully with local and state liquor authori-
The merchandising layout will be completely small sizes. ties about any specific requirements or restric-
different than we know today, with the use of tions because they vary in each area . Merchan-
Residential dise in show windows may be protected by
-Advantages Regular customers . Oppor- grilles or similar devices. Often only one
tunity for promotion . entrance may be permitted, except when the
Liquor Store Management Manual, reprinted -Disadvantages Customers in mixed in- store is within a shopping center . A separate
from Liquor Store Magazine, March 1968 . Cc
1968 by Jobson Publishing Corp ., New York, come groups . Therefore, need to maintain delivery entrance is desirable, but must be well
N.Y- variety of services . controlled from the office and, if possible, from

746
Commercial

RETAIL SHOPS
Liquor

the cashier . Exterior hardware should be throughout the ceiling area to highlight dis-
omitted on this door. plays and accent downlights over the cash-
Show-window platforms should not be too ier.
deep, from 4 ft 0 in . to 5 ft 0 in . and should be For floor covering, carpet is preferred in the
on the low side, from 6 to 24 in . maximum selling areas, or perhaps wood, and hard floor
above the floor. On the exterior, provision must covering for the storage areas.
be made for protection when the store is closed If storage is on a level above or below the
by use of an overhead rolling grille or a folding selling floor, a belt conveyor should be in-
gate . This protection should be over all show stalled . To expedite the handling of the heavy
windows and the entrance door . The entire merchandise, portable roller conveyors should
premises including all wall and roof openings, be used where there are long stock aisles .
such as air intakes and exhausts, must be pro-
tected by a well-designed alarm system .
The interior will be departmentalized to the ex-
tent that hard liquors, wines, and beer are all
grouped and displayed differently. Hard liquors
are displayed and sold from shelving not unlike
that of a supermarket or super-drugstore, in-
cluding the typical price or label holder on the
shelf edge, and are well illuminated from a light
cone at the top of the shelving .
Domestic, inexpensive wines may be dis-
played and sold from shelving similar to that
for hard liquor . Generally wines are stored
lying down as in a wine rack except that several
bottles would be grouped in one opening and
directly under or over the opening would be an
upright bottle carefully displayed to give good
visibility for reading the label. Being able to
read the label on a wine bottle is a must for the
customer . Another method is to have sloping
shelves with the angle changing to give a better
view of the label . Again, all shelving is to be
well illuminated . An illuminated wine chiller,
with displays, is a must since many wines
must be served chilled and a good, steady
customer can be developed if he or she knows
that a chilled wine can be picked up for im-
mediate use. Pull-out shelves, which hold sev-
eral bottles, are also handy so a customer may
accumulate a selection or await a decision
on final selection .
Beer and mixers should be located at the rear
and to the side and, if possible, stored and
displayed in reach-in refrigeration. Where pos-
sible, build these accommodations into the
wall . Loading or refilling from the rear is highly
desirable for this bulky merchandise.
A gift, or specialty, section and impulse
items should be adjacent to or part of the cash-
ier or service counter . Other impulse items,
such as gourmet foods, bar accessories, and
giftware should be located so that they are easi-
ly visible from the exterior .
The cashier, or service counter, is generally
located toward the rear of the store, except for
very large operations where check-out counters
and service carts, as in supermarkets, are
sometimes used . When in the rear, the counter
should be large enough to accommodate at
least two customers at the same time . Discuss
with the operator of the store the special re-
quirements for the working side of the counter:
the various sizes of bags, wrapping materials,
receiving compartments for inventory tags,
handling of cash, and cash register security .
An office working area is required . If possible,
locate it so that from it deliveries can be con-
trolled and a view of the cashier and of the en-
tire store is possible . The entrance door must
be equipped to announce the entering or leav-
ing of any person . Liquor stores are prime tar-
gets for hold-ups and pilferage.
The center of the floor is generally kept free
of fixed fixtures ; use portable gondolas or
islands . Displays often are made up of mer-
chandise and containers and with material fur-
nished by the suppliers . By keeping the center
of the floor flexible, direction and location of
displays can be changed .
In addition to the general lighting and light-
ing over shelving, provide adjustable spotlights Fig. 24 Typical liquor store layouts. (a) Small, self-service . (b) Semi-self-service . (c) Large self-service .

747
Commercial

RETAIL SHOPS
Shoe

By MURRAY S. COHEN, AIA, Architect

SHOE STORES bar of seats allowing efficient circulation for workbench for minor repairs, and a desk
the salemen's traffic route from stock to cus- should be provided in the stock room, with
Diffèrent requirements and customer demands tomer and not crowding the fitting spaces in quick access to sales room . In certain men's
have generally required separate stores for men, front of customer's chairs . Chairs must be com- stores selling a better or higher-priced shoe
women, and children . A shoe store is a volume fortable and have arms to provide separation there will be a shoeshine stand serviced by the
trade operation and is highly competitive. between customers. Provide plenty of fixed or porter or handyman .
The storefront is the see-through type, with a portable shoe-level fitting mirrors as well as Floors in the selling area must be car-
large enclosed show window for display of the occasional full-length mirrors so that custom- peted. In enclosed shopping malls the car-
maximum number of shoes . Average depth of ers can get a full view of their entire figure . pet is often extended out into the vestibule .
the show window is from 4 ft 6 in . to 5 ft 0 in . The shoe shelving generally has some exposed Stock rooms can have hard floor covering .
with platforms 2 ft 0 in . above the floor. Dust space in the sales area and some concealed in Women's stores usually are more plush, have
on shoes shows up very quickly, downgrading rear or side stock rooms or areas. Exposed more of a salon setting, and have less exposed
the merchandise, thus show windows should shelving in sales areas should not be higher stock in the sales area . Seating is more infor-
be enclosed and have tight sliding or hinged ac- than can be reached without a step stool; con- mal, with love seats and groupings in addition
cess doors. A ceiling display grid facilitates the cealed or stock-room shelving can extend up to the individual well-upholstered seat .
handling of suspended items . In show win- to 10 ft 0 in . Where the height is available, two Adjacent to or part of the cashier counter
dows, lighting must be predominantly incan- levels, like library stacks, can be used . A cellar there is an extensive hosiery, glove, handbag,
descent; fluorescent lighting is used only to storeroom is required for reserves . (See Figs . and other matching accessories area . A slipper
provide general illumination . Provide an ex- E5 to 27 .) bar is usually a separate section .
haust to reduce the heat buildup from the Cashier counter should be centrally located In the area or store for children it is highly
lights . Floors will sometimes have removable for good control and accessibility. The hose desirable to have a raised platform, accessible
plywood panels to which changeable materials bar, accessories, and impulse items are general- by steps, so that the salesman can better ob-
are fastened by the window trimmer. ly located near or adjacent to the cashier . serve the fitting and walking without having to
The interior of this type of store must be If possible, arrange for rear delivery of mer- bend or lie down on the floor.
arranged to accommodate the maximum num- chandise . An employee toilet, a combination

Fig . 25 (a) Sock hat . (b( Shoeshine stand .

74 8
26 shoe store
FOR WIDE SHALLOW STORE MIRROR SHOPS

Commercial
RETAIL
Shoe

PLAN FOOT
Fig . Men's .

74 9
Commercial

RETAIL SHOPS
Shoe

Fig. 27 (a) Showcases : open stock shelves (h) Hose counter.

750
Commercial

SUPERMARKETS

By HERBERT ROSS

Architecturally, the supermarket is a large-


scale emporium of merchandise that doesn't
have to shout to be noticed .
Properly situated on its site, the supermarket
and any "satellite shops," attached or not
(shops which can be entered from the market
or from a separate outside entrance) offer a
perking ratio of 3 .6 sq ft to 1 sq ft of total store
area . To obtain the necessary parking area in
areas with high land costs, rooftop and base-
ment parking should be considered . The satel-
lite shops such as convenience grocery stores,
liquor and drugstores, and a carry-out food
shop remain open after the supermarket has
closed for the day .
New, free-standing supermarkets average
22,700 sq ft to 31,000 sq ft with 75 to 80 per-
cent of the total store devoted to selling space
and the remaining 20 to 25 percent of floor
space devoted to service areas such as storage
coolers, prepackaging areas, grocery storage,
etc . Weekly sales per square foot of selling
space vary from $3 .10/sq ft to $3 .75/sq ft
(Fig . 1) .
About 50 percent of the supermarkets total
equipment and fixture investment is in refrig-
eration equipment-meat, dairy, produce,
frozen food, delicatessen, and the storage
coolers necessary for each department . The
remaining 50 percent is devoted to grocery
items--half of which can be nonfood items,
such as housewares, soft goods, glassware,
health, and beauty aids . The most important
square footage is that required by the check-out
stands--one for each $10,000 .00 of projected
weekly volume plus an additional check-stand
for future expansion (this is only a rule of
TOTAL STORE AREA = 30,000 SO . FT .
thumb figure and varies with the region of the TOTAL SALES AREA ° 22,500 SO . FT .
country and the type of service the market SERVICE AREA = 7,500 SQ . FT .
TOTAL
provides the customer) . The accompanying TOTAL PARKING AREA = 108,000 SO . FT .
plan, adapted to the individual operation re- IRECOMENDEDI
quirements, provides a practical guide in the
layout of a supermarket .
TOTAL. ANTICIPATED
Assuming proper location of the store on WEEKLY SALES - $90 ,00000
the site, one which makes it most accessible .
(@ $3 .75 PER SQ . FT OF
to traffic and parking, the next step would be SALES AREA)
to decide on the configuration of the store . TOTALCHECKOUTS
Generally, free-standing markets tend to be (ONE FOR EACH $19r000 00
10
rectangular in shape, with the narrower portion OF SALES PLUS ONE
forming the front-to-rear dimension . Since FOR EXPANSION)
most often the deliveries are at the rear, the
various back room areas (preparation and Fig . 1 Typical free-standing supermarket.
storage) are located at the rear of the building,
leaving the selling space more or less square .
At this point, the method of construction
must be considered, particularly the location
of any columns . Ideally, these should be kept
would obstruct the overall view of the store . use of self-contained refrigerated cases (with
out of the shopping aisles . Assuming a 7 ft 0 in .
The refrigerated cases should be placed as a few exceptions) impractical . Therefore, some
aisle between 4 ft 0 in . wide shelving islands,
near as practicable to their associated work sort of centralized refrigeration system is
columns spaced in a multiple of 11 ft 0 in . will
rooms and storage coolers . This also applies employed . (All major refrigeration equipment
keep the columns out of the aisles . (Shelving
to the service departments such as the delica- manufacturers offer a form of centralized re-
can be cut to fit around columns, and this is
lessen,in-store bakery, and snack bar . frigeration system and all are basically alike .)
preferred to columns in the shopping aisles .)
Since all merchandise purchases must be Such a system utilizes a bank of compressors
Although refrigerated fixtures have been and
funneled through the check-out counters, they and condensers (air- or water-cooled) located
can be located almost anywhere on the sales
floor, most often they are located at the walls . are all located in one location (usually at the in one room with liquid refrigerant running to
front of the store near the exit door) . the individual cases and the heated gas being
They tend to be too large and bulky to be
placed in any central location, where they The size of today's supermarket makes the returned to the condensers .

75 1
Commercial
SUPERMARKETS

By EGMONT ARENS, Industrial Designer

Good vision are (drawing at left)


demands that top shelf be not over
5 ft . 3 in . high, permitting an angle
of view not more than 15° above
the horizontal . Easy-to-reach zone
starts at about 15 in . above the
floor, the minimum height for the
bottom shelf . Face of cans or . pack-
ages should be as nearly at right
angles to eye as practical . Cans for
bottom shelves are now designed
to be legible lying on their side .
Length of "super island" units
varies, 9 ft . being the longest in
common use . Distance between
shelf supports varies about a norm
of 2 ft . 6 in . Supports should be set
back to permit an appearance of
uninterrupted merchandise .

SUPER-SHELVING
NOTE - SHELVES MAY BE 1 %6"BOARDS. NOTE - PLAN MAY BE
SEMICIRCULAR OR RECTANGULAR .
NOTE -PLAN MAY BE CUSTOMERS ARE NOT APT TO DIS
SEMI-CIRCULAR OR RECTANGULAR TURB A SYMMETRICAL DISPLAY, NOTE - DOTTED LINE INDICATES
C() nrx)nt APF PI ArFn AT RAWDOKA IMPORTANT AREA FOR SMALL
ARTICLES OR FOR MERCHANDISE
SUBJECT TO 'IMPULSE BUYINO' .

ELEVATION ELEVATION SECTION


COUNTER
TU tit BLE DISPLAY END DISPLAY CHECK - OUT

SECTION SECTION

HALF - SECTION SECTION


CAKE SHELVES BREAD SHELVES
NOTE - SHELVES MAY BE NOTE- SHELVES MAY BE
U2' THICK PLYWOOD '/2" THICK PLYWOOD SUPER-ISLAND FRUIT $VEGETABLE BINS

75 2
Commercial

BANKS

second floor of a building, escala- f. Safety deposit vault, fireproof . This


New bank merchandising systems have been provides boxes for the storage and
followed by a new bank architecture which no tors are recommended for public
conveyance to the lobby. safekeeping of customers' valuables .
longer needs to follow the old idiom that a Coupon booths of minimal size and a
bank must retain its aloof dignity . Stability (2) Tellers should be located so that
they are easily accessible and so conference room large enough to hold
and strength are still to be preserved in the 10 to 20 people should be provided .
image of the bank, but not to extremes . that the spaces surrounding them
allow easy circulation of the g. General services . This includes
Bankers of today have recognized the toilets, employees' lounge, snack
increased mobility of the nation and the finan- public .
bar, mechanical equipment, mainte-
cial needs of the average homeowner, and in (3) Loan officers and others who have
direct contact with the customer nance, and PBX .
combining the two have arrived at a new Jr . Drive-in and walk-up tellers. These
expression and image for the bank . In projec- should be readily available.
(4) Check-writing desks should be teller windows are an essential part
tion of future trends, these bankers indicate of a bank . Their design should be
that the bank of the next decade will blend placed so as not to block circula-
tion, especially of the lineup carefully considered with regard to
excitement and attraction with dignity and a flow of traffic and security .
modern feeling of solidity . "The banks will be space in front of the tellers.
b. Tellers are usually located at one side i. Trust department . This is one of the
made more inviting through the further use of bank's major services to the public .
glass, color, and art; and by offering their of the bank to allow for expansion. This
is usually considered to be the most It is here that trusts, probates, ac-
services more conveniently ; and through counts, etc., are put in effect and
increased point of contact at the street and flexible of all schemes .
C. Officers' platform . This should pro- carried out . This area also needs a
through drive-in facilities ."' lawyers' department .
The innovation of the drive-in and walk-up vide open space for contact officers,
cubicles for collection officers, and j. Auditorium/meeting room able to seat
window recognizes today's informal, mobile 200 to 300. This room is mostly used
living and extends the bank's services to offices for the installment loan and
commercial loan officers . A conference by the public and is often loaned
make them more attractive and more conven- rent free . Rest room facilities, a
ient to the public . Elements that remain open room should be provided in this area
unless the need warrants more than stage, storage space, and coffee bar
after regular banking hours, such as a meeting should be included . This room should
room, savings department, and safety deposit one.
d. Access to the safety deposit vault be thought of as an all-purpose room .
vault, serve the needs not only of the customer In addition to serving as a meeting
of the bank but of the general public as well . should be provided for customers .
Access to the money vault for tellers room, it will facilitate the training of
Flexibility, then, becomes a key word in bank bank personnel .
design . The bank of today cannot subsist under should be provided .
2 . Operations . This is the department that 3. Executive suite. Usually includes offices
the old idea that a bank is for money only, for the senior vice-presidents, board
especially when its image is concerned with makes sure the bank is run on a steady,
professional basis. It takes care of all members, and president plus all the
public activities along with regular banking personnel they need to continue their
activities . the clerical work required to run the bank
and keep its records in order. business . A conference room and board
The place in which the bank's transactions of directors' meeting room are re-
take place should be attractive, friendly, and a. Bookkeeping department . This should
be in close proximity to tellers, since quired .
unimposing ; a minimum obstruction between 4 . Buildings. It is the duty of this depart-
the customer and the bank's representatives this is where the tellers receive and
give all the information they need . ment to maintain the physical building,
is a must . keep records, and collect rental fees for
However, before any design requirements 6. Proof department . This is not acces-
sible to the public . It can be separated all spaces in the building owned by the
can be made, the building requirements (both bank .
personnel and departmental) must be firmly from the other areas, but should be
fairly close to the data processing 5. Legal department . This department
established and the basic philosophy of bank- keeps the bank's legal business in order .
ing operations and building design agreed area .
c. Data processing area . Special air A library/conference room is usually
upon . included in this area .
conditioning is required here . False
floors are recommended to house 6 . Date processing . This department helps
the electric cables . to facilitate and process the bank's
DESCRIPTION OF SPACES
d. Clerical, mail, and other various checking, payroll, operations, and other
minor services as required by the procedures .
1 . Public spaces
individual situation. The mail room 7 . Mail room . The mail room usually con-
a. Lobby . This must be easily accessible microfilm
is usually located in close proximity tains the addressograph,
to the public 11 contains reception/ equipment, duplicating machines, and
information, loan officers, tellers, and to the proof department .
e. Fireproof records vault, to service other equipment necessary to run this
check-writing desks.
proof, trust, and bookkeeping depart- operation . This area should be located
(1) If located on the lower level or
ments. This does not have to be near a service yard or elevator and in
adjacent to all three, but access conjunction with the printing/purchasing
must be provided for all three. department .
' Banking, vol . 56, pp . 57-58, February, 1964 .

75 3
Commercial
BANK VAULTS

Fig . 1 The above plans are recommended for single-aisle vaults up to 14' inside clear widths . Interior
vault dimensions should be established in accordance with individual requirements and the emergency
vault ventilator should be located through a convenient wall area that is exposed inside the building .
Location of the vault alarm control cabinet is designed [sic] by "A" and should be recessed in the
vault wall when if interferes with the removal of the bond boxes . When the vault width is 14' or more,
refer to double- or multiple-aisle vault plans . (Mosler Safe Co .)

VAULT PLAN - D 114'W x 14'D x 8'H INSIDE) VAULT PLAN - E (14'W x 16'D x B' H INSIDE)
l . 196 sq, ft . Inside floor area . I 224 sq . ft . inside floor area .
2 . 26 lin . ft . for s . d . boxes . 2. 36 lin . ft for s d boxes .
3 . 12 lin . ft . for lockers_ 3. 12 lin ft for iodera

Fig. 2 The above plans are recommended for double-aisle vaults from 14' to 16' inside clear widths .
Interior vault dimensions should be established in accordance with individual requirements and the emer-
gency vault ventilator and emergency door should be located through a convenient wall area that is
exposed inside the building. Location of the vault alarm control cabinet is designed [sic] by "A ." When
planning vaults with three or more aisles, refer to the multiple-aisle bank vault plans . (Mosler Safe Co .)

754
Commercial

RESTAURANTS AND EATING PLACES

By LENDAL H. KOTSCHEVAR and MARGARET E. TERRELL

SPACE REQUIREMENTS Dining Area ages, ice, butter, and condiments may measure
20 to 24 in . square and 36 to 38 in . high . The
Adequacy of space will influence building and Space for dining areas is usually based on the size of central stations varies from that for a
operating costs and efficiency . When space is number of square feet per person seated times small enclosed room to that of a screened
too small, labor time end effort are likely to the number of persons seated at one time . section measuring approximately 8 to 10 ft
increase end the volume and quality of output long by 27 to 30 in . wide by 6 to 7 k high .
decrease. When it is too large, building and Spate Requirements The patron's size and the Table size will influence patron comfort and
maintenance costs are excessive. type and quality of service should be consid- efficient utilization of space. In a cafeteria,
Decisions pertaining to apace allowance ered . Small children may require only 8 sq ft for example, where patrons may dine an their
may be strongly affected by the limitations of for a type of service in which an adult would trays, it Is important that the table be of ade-
investment funds and available space. Ample need 12 sq ft for comfort. A banquet seating quate size to accommodate the number of
space is sometimes provided by means of low- allowance might be as little as 10 aq ft per trays likely to be there. Four trays 14 by 18
cost materials and equipment of such inferior seat and that for a deluxe restaurant as much in . fit better on a table 48 in . square than on
quality that they have short and unsatisfactory as 20 sq ft . The amount of serving equipment s table 36 or 42 in . square . Smell tables, such
service life . In other instances, space is in the dining area and lineup space will influ- as 24 or 30 in . square, are economical for seat-
restricted to a point where it prohibits profit- ence needs. Lost apace must be considered . ing but are uncomfortable for large people .
able volume or the best utilization of labor. The diner's comfort should govern allow- They are only suitable in crowded areas for
Space allowances in relation to investment ance. Crowding is distasteful to many people . fast turnover and light meals. Tables having
should be balanced in terms of (1) proposed It is likely to be tolerated more readily by common width and height allowing them to be
permanence of the facility, (2) acuteness of youngsters than by adults . It is more accept- fitted together will give flexibility in seating
need for the specific operation, (3) essentials able in low-cost, quick-service units than In arrangements. These are particularly good for
for operating efficiency, (4) desirable standards those featuring leisurely dining . Both young banquette or cocktail-type bench seating
in terms of appearance, sanitation, and good and old enjoy having sufficient elbow room along a wall . Tables for. booths are difficult
quality of production and service, and (5) and enough space so that dishes of food and for waitresses to serve if they are longer then
immediate and future costs, depreciation, beverage are not crowded. Place settings for 4 ft . The width of booths including seats and
upkeep, and maintenance . adults usually allow 24 in . and for children table is commonly 5h ft . A lunch counter
Facts peculiar to the particular establishment 18 to 20 in . (Table 1) . will have a minimum width of 16 in . and a
should be used as the basis for determining maximum width of 24 to 30 in . The linear feet
space needs. Requirements will vary for are calculated on the basis of 20 to 24 in . per
facilities of a given type and volume . Location ; TABLE t Square Feet per Seat Used for seat . The maximum area best served by one
type of operation ; clientele; frequency of Various Types of Food Operations waitress is generally 16 ft of counter. This
deliveries of supplies ; kind of food used, such Square loot per seat will give eight to tan seats. U-shaped counters
Type of operation
as fresh, frozen, or canned ; and the complete- make maximum use of space and reduce travel .
ness of processing to be done will cause Cafeteria, commercial . . . . . . . 18-18 Space in depth of 8'/r to 11 ft will be required
variation in production and storage require- for every linear foot of counter. This will pro-
Cafeteria, college and
ments. The policies of those in charge will 12-15 vide 3 to 4 ft of public aisle, 2j& ft for aisle
have an influence . Certain general information, industriel . . . . . . . . . . . . . space for employees . A width of 41h ft is desir-
Cafeteria, school lunchroom . . . . 9-12
such as numbers to be served, turnover, able where employees must pass .
arrival rate, and type of service, will be helpful College residence, Calculate aisle space between tables and
in deciding dining area needs. table service . . . . . . . . . . 12-15 chairs to include passage area and that occu-
Study is required to clarify immediate and Counter service . . . . . . . . . . . 18-20 pied by the person seated at the table. A
future needs in food production . Choices Table service, hotel, minimum passage area is 18 in . between chairs
should be made between meat cutting or club restaurant . . . . . . . . . . . 15-18 and, including chair area, tables should be
portion-ready meats, a baking section or use spaced 4 to 5 ft apart . Aisles on which bus
Table service,
of commercially bakea products, and the use of 11-14 carts or other mobile equipment is to be
unprocessed versus processed foods . If minimum eating . . . . . . . . . moved should be sized according to the width
enlargement is probable, studies made before Banquet, minimum . . . . . . . . 10-11 of such equipment.
the building is planned as to how space may The best utilization of space can often
be added and how the initial plan should be be arrived at through the use of templates
designed to minimize ultimate cost, will be All of the areas in a dining room used for or scaled models . Diagonal arrangement
helpful . purposes other than seating are a part of the of square tables utilizes space better then
It is well to block out space allowances square footage allowed for seating . This does square arrangement and yields a more trouble-
according to functions that the facility is to not include waiting areas, guest facilities, free traffic lone . Lanes that pass between
perform. Calculate area requirements in cloakrooms, and other similar areas. Excessive backs of chairs are likely to be blocked when
terms of : (1) volume and type of service, (2) loss or use of space for other than seating guests arise or are being seated.
amount and size of equipment to be used, (3) in the dining area will, however, increase Table heights in schools should be chosen
number of workers required, (4) space for needs. Structural features of the room should for the comfort of children . In units patronized
needed supplies, and (5) suitable traffic area . be considered . Width and length of the room, by many grades a compromise height will be
The dining area location and space allowance table and chair sizes, and seating arrangements needed between the 30 in . normally used for
are usually determined first, the production affect capacity . adults and the 24 in . suitable for children, or
areas next in terms of specific relationship Service stations may be estimated in the two sizes may be used in different sections of
to the dining area, and the other sections an proportion of one small one for every 20 seats the room . A table length to most four, six, or
required to these. Planners should be careful or a large central one for every 50 to 60 places . eight is preferable to longer ones .
in accepting general apace recommendations. The advisability of having a central serving
There are many variations . station will be influenced by the distance of Number of Persons Allowance The number of
the dining area from the serving area . It is of persons to be seated at one time is the second
special value when production and dining are point of information needed for calculation
on different floors . Plumbing and wiring and of the dining room size . The total number of
whether supplies are delivered mechanically seats required at one time, multiplied by the
will influence location of the stations . Small space required for each seat, will give the
Food Service Planning, John Wiley & Sons, total number of square feet needed in the
New York, 1967 . substations for silver, dishes, napery, bever-

75 5
Commercial

RESTAURANTS AND EATING PLACES

dining area . The number of times a seat is the price plan (on the basis of subsidy or prof- 600 men has an overflow room seating 100,
occupied during a given period is commonly it), patron's mealtime allowance, and conven- which it uses only at dinner . The night meal
referred to as "turnover." The turnover per ience of the location . is not only larger but the men dine in a more
hour, times the number of seats available, gives The patronage estimate for e college cafete- leisurely fashion . The room is available for
the total number of patrons who can be served ria should take into consideration the number serving other groups at breakfast and lunch.
in an hour . If peak loads, or number to be of students who live at home, are members of Commercial restaurants located in shopping
served at one time, are known, the number of a live-in group, such as an organized house, or office areas often have a heavier demand
seats required can be estimated. and the number of other dining facilities at noon than at the dinner hour . Rooms used
Turnover re tea tend to vary, for they are available on or near the campus . A college for general patronage at noon may be closed
influenced by such factors as the amount of residence providing table service may have at night or provide space for private dinner
food eaten, the elaborateness of the service, to allow a seating capacity that is 110 percent parties . Entrances to these rooms should not
and the diner's time allowance. A breakfast of occupancy if a policy exists for having require passage through the main dining
meal of few foods may be eaten more quickly "special guest" occasions and seating all at room . Convenience for special service is
than dinner, and a simple fare faster than e one time . important.
many-course meal . Turnover is quickest in An industrial lunchroom may serve as few
dining rooms where food has been prepared as 25 percent and as many as 90 percent of the
in advance for fast service and where patrons payroll . Clues to probable patronage may be
Production Areas
serve themselves and bus their soiled dishes . drawn from such factors as nearness to other A frequently used rule for allotting apace for
The turnover time is speeded up 10 percent eating facilities, wage rates, type of work, the kitchen is that it should be one-third to one-
by patrons removing their soiled dishes an that prices to be charged, convenience, quality, half the area of the dining room . It has been
tables are quickly available for other guests . and attractiveness . The attitude of manage- found unsatisfactory, however, to go by a set
Deluxe service for leisure dining, involving ment toward the lunchroom may affect patron- space allowance for this area . Detailed study
removal and placement of several courses, age also . Pride in providing a good service for of space allocations leads to the conclusion
takes the longest time . Although specific the industrial family as opposed to a take-it- that percentages in relation to the dining area
turnover may very from 10 minutes to 2 hours, or-leave-it attitude tends to win favorable are "completely unrealistic and unreliable ."
actual eating time is normally 10 to 15 minutes response . An analysis of specific needs is required . Many
for breakfast, 15 to 20 minutes for lunch, end The size of a dining room in a hospital factors influence space requirements, such as :
30 to 40 minutes for dinner . should be determined as to whether it is to be 1 . Type of preparation and service
The calculation of occupancy of seats in a used for employees, patients, or guests, or 2. Amount of the total production done in
dining room must take into consideration a any combination of these . The type of hospital the unit
certain percentage of vacancy, except where and the number of ambulatory patients should 3. Volume in terms of the number of meals
a given number are seated at one time accord- also be considered . The type of hospital will served
ing to assignment . In table-service dining also influence the number of personnel em- 4. Variety of foods offered in the menu
rooms this has been estimated as 20 percent ployed . The ratio of personnel to patients 5. Elaborateness of préparation and service
of total capacity, in cafeterias from 12 to 18 will very from 1 to 3, depending on how much 6. Amount of individual service given, as in
percent, and for counter operations 10 to special care is required or how much teaching a hospital trey service
12 percent. Many factors influence this per- end research are done . Good food and reason- 7. Seating and service plan, whether on one
centage, such as patrons arriving at different able prices will attract a high percentage of floor or many
times, irregular rate of turnover, and reluctance those eligible to set in the facility . The cost of providing space, equipment, and
to share a table with strangers. School lunch participation varies 25 to 75 labor is sufficient to merit careful calculation
The table sizes used in the dining room will percent and a good percentage for planning of the beat type of operation before planning .
affect occupancy . It is often desirable to is 60 to 75 percent of enrollment . Where New products on the market, new cooking
provide for groups varying from two to eight, prices are low, the food good, meal selections methods, and new equipment available should
with a predominance in most dining rooms appealing, and the food service carefully be evaluated. The use of preprocessed pro-
of those for two people . The "deuces" may be integrated with the educational program, the ducts in many metropolitan areas has made a
of a size and shape that can be put together to percentage will be high . pronounced change in the amount of space
form tables for larger groups . In metropolitan Banquet seating requires planning because allotted for bake shop, meat cutting, end vege-
areas where many tend to dine alone, wall maximum seating potential means maximum table preparation areas. Where portion-cut
bench-type seating and tables for two with a profits . Folding tables 30 in . wide are popular. meats are readily available, it is questionable
center ridge or line denoting space for one have These are obtained in varying lengths, but 72 whether even a large establishment can afford
been used successfully . Chairs with a "tablet- and 96 in . are commonly used . The spacing to equip and provide skilled labor for a butcher
arm" that will fold a tray have been used for for the legs should be such as to allow for shop . The use of large quantities of frozen
fast turnover in crowded areas. comfortable seating when the tables are joined foods affects storage needs . The cost end
The utilization of seating capacity tends to end to end and place settings are laid on quality of market products, their availability,
be greater for cafeterias than for table service . 24-in. centers. and the frequency of deliveries are all to be
The patron may spend 25 to 50 percent of the Restaurant operators should consider space considered .
time while seated at the table waiting for in relation to patronage volume essential for Variety in menu selection and elaboration of
service . The cafeteria diner may begin eating a profitable business . Labor, food, end operat- foods tend to increase space needs in work
es soon as he is seated . One cafeteria line ing costs must be met and a profit realized areas and storage. Small amounts of numer-
can serve four to eight patrons per minute that covers risk-bearing effort expanded and ous items do not permit stacking and bulk
depending on (1) the speed of the servers, return on investment . Essential income is packaging. Elaboration of food often involves
(2) the elaborateness of food selection, (3) weighed in the light of probable patronage and individual portion treatment, with individual
convenience of the layout, and (4) the type probable average check. The number of seats casseroles, for example, as compared to bulk
of patrons . At these rates, 240 to 480 patrons provided in planning must cover this need . steam table pans . A hospital food service
will need to be seated within an hour . If the Flexibility in seating capacity is often desir- requiring many special diets serves as a com-
turnover rate is two per hour, then from 120 able . People do not like to be crowded nor do mon example of menu variety end individual
to 240 seats will be used . However, if 15 they enjoy the lonely experience of being portion treatment imposing special space
percent of the total capacity at the peak period seated in a huge area occupied by only a few. requirements .
remains unfilled, then between 140 and 280 Sparse patronage creates an impression of The equipment provided will affect the space
seats will be required . An additional 14 to poor popularity . Separate rooms, folding needs. Garbage and refuse, for example, may
28 seats or 10 percent would be needed if the doors, screens, or other attractive devices can require a sizable area for storage awaiting
patrons do not bus their soiled dishes . be used to reduce size of an area during slack pickup . Disposal units for food garbage, incin-
Patronage estimates for facilities of different periods. Sections left open should be those erator for burnable refuse, and a crusher for
types may be guided by the number of persons easiest to serve. Balconies, back rooms, or tin cans will greatly reduce the amount to be
in residence, enrollments in a school, an other leas desirable space can often be used held . Frequency of garbage collection will mini-
industry's payroll, the membership of a club, for overflow numbers that occasionally require mize the space needs.
or the amount of traffic in an office or shop- service . Structural features of the building may
ping area . In each case a certain percentage A common experience in many dining room influence the utilization of space. The shape
may normally be expected to dine in the facility operations is the need for more seating at of the kitchen, location of ventilation and ele-
provided . The percentage will be influenced one meal than at others . This may be due vator shafts, support columns and partitions
by such factors as its location in relation to either to increased numbers or different should be considered in relation to an efficient
other facilities, the patron's buying power, turnover rates. A residence cafeteria serving layout for work . The location of entrances and

756
Commercial

RESTAURANTS AND EATING PLACES

exits for a good flow of traffic, window place- side by side . A height of 34 in ., commonly used in school lunchrooms average around 15 to 20
ment, suitable space, and relationship of sec- as a working height, should be evaluated in ft . Some commercial cafeteria counters may
tions need consideration . Eliminate partitions terms of specific work done and equipment be 70 to 80 ft long, but counters over 50 ft long
whenever possible ; this will reduce space used . are frequently considered inefficient. Twenty
needs and also permit easier supervision of Aisle space should permit free, easy move- feet is usually thought of as a minimum but,
production areas. ment of essential traffic. The minimum width under special conditions and where a limited
Kitchens serving a smaller number require for a lane between equipment where one per- menu is served, 6 to 8 ft may be sufficient .
son works alone is 36 and 42 in . where more The trend is toward shorter counters with
a larger square footage per meal than those
serving a larger number . The following date than one is employed and where workers must mobile serving units or dish holders set at right
used for industrial cafeterias show the rate at pass each other in the progress of work . Where angles to the counter . Smoother service and
mobile equipment is used, 48 to 54 in . are greater speed are achieved . Counter height
which space needs per meal tend to decrease
as the number served increases (Table 2) . recommended. At least 60 in . are needed for may be set at comfortable levels for workers
main traffic lanes where workers regularly and patrons . Schools may have lower counters
pass each other with mobile equipment . If so that children may see the food and push
TABLE 2 Variation in Space Needs in Relation their trays along a slide as they are served .
workers or equipment must stand in the lane
to Numbers Served while working, appropriate space should be For little folk, 28 to 30 in . i s desirable, with
allowed for this . Thought should be given to counters narrow so that servers may reach
Square feet Variation in over to assist a child. A solid tray slide tends
apace for doors opening into an aisle and for
Meal load per meal square feet handling large pieces of equipment, such as to result in fewer accidents than those made of
500-1,000 roasting pans, baking sheets, and stock pots . bars or tubing . Plastic treys measuring 9 by 12
100-200 5 .00
Main thoroughfares should not pass through in ., compartmented, and of pastel colors are
200-400 4 .00 800-1,600
work centers. Compactness is essential for popular .. Slides for these may be on the servers'
400-800 3 .50 1,400-2,800 side of the counter for ease of service and to
step-saving . It is well for the work centers to
800-1,300 3 .00 2,400-3,900 eliminate spillage or accidents . The child picks
be in close proximity to main traffic lanes, with
1,300-2,000 2 .50 3,250-5,000 easy access to them . It is important both to up the completed service at the end of the line .
2,000-3,000 2 .00 4,000-6 .000 avoid distraction from outsiders passing Some planners use, as a rough guide, one
3,000-5,000 1 .85 5,500-9,250 through work centers and to conserve space. counter or line for every 250 to 300 patrons
Work centers at right angles to traffic lanes served, but arrival rate, speed of service, and
are efficient (Fig . 1) . turnover are more reliable factors to consider
Planners are often asked to make estimates The percentage of floor area covered by in establishing the number of lines required .
of space needs before having an opportunity equipment varies according to production Hospital service space will depend upon
to make policies or detailed plans for opera- needs and the type of equipment used . A satis- whether central or floor service is used, trays
tions. Figures that will be found useful in factory layout may claim less than 30 percent are set up in serving pantries, and modified
making such estimates are given in Table 3 . of total space for equipment while work areas, diets are set up in line or in a diet kitchen.
These figures pertain to average kitchen areas traffic lanes, and space around equipment for Space must be allowed for bulk food trucks,
found in different types of food facilities . Their easy operation and cleaning may require 70 tray trucks, small tray carts, or special dis-
use is to be regarded as tentative and to be percent or more . pensing units used .
measured carefully in terms of specific needs. For hospital production and service areas, Short-order units where food moves directly
The square footage given is to be multiplied by 20 to 30 sq ft per bed is suggested. The need from production to the consumer require the
the maximum number of meals estimated per is reduced as the number of beds increases- least service space . The need for an inter-
hour of service, in order to find the total space approximately 30 sq ft per bed for a 50-bed, mediate station is eliminated . Step-saving com-
requirement . and 20 sq ft per bed for a 200-bed hospital . pactness saves space. The units requiring the
After production policies have been estab- This allowance does not include major storage most space are those furnishing elaborate or
lished, work areas may be blocked out in terms areas, dining rooms, employee facilities, or highly individualized service .
of the equipment needs and the number of floor serving pantries .
workers required to do the work in a section . Receiving and Storage Areas
Linear space, depths, and heights for work Serving Areas
centers should be controlled in terms of aver- Space allocation for receiving and storage must
be based on specific needs . The volume and
age human measurements . This will include the Space allowance of serving areas should be
reach to and grasp of materiel or equipment adapted to the needs of the specific facility . type of items received and stored should be
used in working. The length and width of the The menu, organization of work, and number considered . Although the average operation
work table is adjusted in terms of the amount served will influence size . The type of service may find a dock 8 ft deep and 12 ft long suffi-
will also be influential in dictating space cient for receiving items, this would not be
and size of equipment that will rest on it during
sufficient for a large one. The space require-
the progress of work . The linear measurement needed .
In cafeterias the counter length should be ment in square feet for food storage for 30 days
will very in terms of the number of workers
regulated by the variety and volume . Excess has been calculated by some as approximately
using it at one time .
space partially filled is unattractive, but crowd- one half the total served or, if 1,000 are served,
The width of the table may be 24 to 30 in .
ing is also undesirable. An estimate that may 500 sq ft may be used as a tentative figure for
unless dishes or food containers are to rest
be used for allotting width is 14 ft. This allows total food storage needs. Cases of 6/10's
at the back of the table. Tables 36 in . wide are
preferable when the back of the area is used for for 4 ft as patron lane space, 1 ft trey elide, 2 ft stacked 6 cases high on flat trucks will have e
such storage. Where two workers work oppo- counter width, 4'/r ft for workers, and 2'/r ft bearing weight of approximately 250 to 300 Ill
site each other, a table 42 in . wide may be used . for back bar . The size of the tray should dictate per sq ft . Skid sizes should be 3 by 2'/t ft by
A work area of 4 to 6 lin ft will be within con- the width of the tray slide. The average length 8 to 12 in . high . Where heavy items, such as
venient reach of the average person . Tables 8 of counters in college residence halls and 10-gal cans of milk, are stored, bearing weights
to 10 k long are used if two people are working hospitals is found to be 30 to 32 ft, while those may be increased. One case of 6/10's, 24/2'4's,
or 24/2's weighs approximately 50 Ill end
occupies 1 cu ft .
TABLE 3 Square Feet of Kitchen Space per Meal for Food Facilities of Different Type
and Size Common Storage The volume of canned food
needed to serve 100 persona three meals daily
Estimated maximum meals per hour for one month is estimated at approximately 45
Type of facility 200 or less 200-400 400-800 800-1,300 1,300-7,500 cases of 6/10's or equivalent . The maximum
stack height will be 8 or 9 cases or approxi-
Cafeterias . . . . . . . . . . . . 7 .5-5 .0 5 .0-4 .0 4 .0-3 .5 3 .5-3 .0 3 .0-1 .8 mately 72 in . Accessibility of items that differ,
Hospitals . . . . . . . . . . . . 18 .0-4 .5 12 .0-4 .5 11 .0-4 .5 10 .0-4 .0 8 .0-4 .0 as well as volume, will govern the number of
Hotels . . . . . . . . . . . . . . 18 .0-4 .0 7 .5-3 .0 6 .0-3 .0 4 .0-3 .0 4 .0-3 .0 stacks needed . A total of 3 cu . ft per stack
Industrial lunchrooms . . . . . 7 .5-5 .0 4 .0-3 .2 3 .5-2 .0 3 .0-2 .0 2 .5-1 .7 is estimated to include floor space covered by
Lunch counters . . . . . . . . . 7 .5-2 .0 2 .0-1 .5 a case of canned food, plus a share of aisle
space. One thousand cases piled eight high in
Railroad dining car . . . . . . 1 .6 125 stacks will require 375 sq ft or a storage
Restaurants (service) - 7 .0-4 .0 5 .0-3 .6 5 .0-3 .6 5 .0-3 .0 5 .0-3 .0 area approximately 20 by 20 ft . Storeroom
School lunchrooms . . . . . . . 4 .0-3 .3 3 .3-2 .2 3 .0-2 .0 2 .5-1 .6 2 .0-1 .6 aisles may be as narrow as 36 in ., but 42 or 48

757
Commercial

RESTAURANTS AND EATING PLACES

mated 0.1 to 0.3 cu ft per meal served . Addi-


tional low-ternperatu re or refrigerated space
in terms of reach-ins was not calculated . In
some climates, refrigerated space must be pro-
vided for dried fruits, nuts, cereals, and other
foods to prevent weevil and insect infestation .
A walk-in becomes feasible for an operation
serving 300 to 400 meals per day, and refriger-
ated pass-throughs can be added when from
400 to 500 meals are served per day. A walk-in
5 to 6 ft wide does not permit storage on both
sides with adequate aisle space. Storage space
of 1 h to 2 ft should be allowed on either side
of the aisle. If crates or cases are stored, this
may have to be increased. Aisles of 30 in . are
usually too narrow ; 42 in . are desirable . If
mobile equipment is moved in and out, aisles
may have to be wider. Walk-ins that are 8 to 9
ft wide and about 10 ft long are minimum size .
This allows for two storage areas 30 in . wide
with a 3 to 4 ft aisle. If added width is desired
for storage space in the center, allowance for
storage areas of about 3 ft wide and 42 in . mini-
mum aisles should be provided . Large walk-ins
may be designed for lift truck operation, with
doors opening from the receiving dock on one
side and into the kitchen opposite . If this is
done and lift trucks are used, space must be
provided in storage aisles for their working
end turning around . Doors should be a mini-
mum of 42 in . wide to admit large crates and
containers or be sized to suit mobile equip-
ment . Doors to low-temperature areas are most
often planned to open into a refrigerated area .
If this is not done a heating device may have
to be installed on a door opening into a warm
area to prevent its freezing tight from conden-
sation . About 12 to 15 sq ft must be kept free
for every door opening . About 45 Ib of frozen
food, if stacked in cases, can be stored per
cubic foot. About 30 to 35 Ib of refrigerated
food can be stored per cubic foot .

Sanitation Areas
Dishwashing Area The space required for the
dishwashing operation depends on the meth-
ods and equipment used . In all instances there
must be adequate room to receive the volume
Fig. 1 Flow diagram showing functional relationships . of soiled dishes likely to arrive at any one time,
plus space for scraping, stacking, and placing
in baskets on a conveyor of a machine or into a
in . are preferred . Wider aisles may be required men is 84'/ in . and of women 81 in . Use of the prerinsing operation . The dimensions may be
if trucks are used . A 3-ft skid on a hydraulic top shelf for light, bulky packages, such as only 30 to 36 in . for a single tank machine,
jack needs maneuvering room . If rolling bins cereal, is recommended. 60 to 72 in . for sinks, or 7 to over 30 ft for a
or garbage cans on dollies are used for storage, conveyor-type machine. The requirements in
plan location for these. If cans or bins are Refrigerated and Low-Temperature Storage There the clean dish area will vary . It is important that
under shelves, adjust height of bottom shelf are many factors affecting space needs for there be enough space for dishes to be exposed
to clear and allow for work space for removing refrigerated and low-temperature foods. to air for sufficient time to air-dry before stack-
food from these containers . Fixed shelving Across-the-board figures generally should be ing . For a basket-type machine, it is well to
will be beat when planned to suit the sizes of used only in preliminary estimates . The quan- allow space equal to that required for three
items stored . Consider both interspace and tity stored at one time will dictate the storage baskets, a stack of trays, and three or four
depth suitable . Condiment bottles, cereal pack- needs . Variation in the type of storage also will stacks of dishes . For basket machines, it is
ages, and canned goods differ in package sizes be indicated by the types of items to be stored . usually recommended that the clean dish area
and in stacking quality. The depth of a shelf Allocation in preliminary planning may be as occupy 66 percent of the total table space
should accommodate either the width or length follows: 20 to 35 percent for meat (portion- and the soiled dish area, 40 percent.
of the case, and the interspace should be ade- ready meats require '/ to '/, less space than Methods used for transporting and storing
quate for the number to be stacked one on top carcass or wholesale cuts); 30 to 35 percent dishes will influence space needs. Where
of another. Allow 1'/ to 2 in . as free space for fruits and vegetables ; 20 to 25 percent for mobile storage equipment is used, more space
for ease of positioning . Add thickness of shelv- dairy products, including those in serving is needed for the several units than where
ing to interspace when stating measurements areas ; 10 to 25 percent for frozen foods ; and one cart is used for transporting and is repeat-
between centers . 5 to 10 percent for carry-over foods, salads, edly loaded and unloaded . A table surface is
Position heavy items to reduce lifting and sandwich material, and bakery products . A desirable for sorting, treating, or inspecting
facilitate dispensing . Drums of oil and vinegar requirement of 15 to 20 cu ft of refrigeration silver and other tableware. The installation of
should have spigots and be equipped with per 100 complete meals has also been used by e domestic washer and drier in the dishroom
pumps or located on cradles . Table surface some planners . Others state 1 to 1'/ cu ft of may require space.
and scales should be located for convenient usable refrigerator space should be provided
issuing of dry stores . Plan to have all products for every three meals served . Analysis of a Pot end Pan Section Provide a soiled utensil
at least 6 in . above the floor or movable to facil- number of award-winning installations indi- collection area adequate for the largest volume
itate cleaning of storage area . Limit height cated that approximately 0.25 to 0.50 cu ft of that normally arrives in the section at one time.
of top shelf for easy reach without aid of stool refrigerated walk-in space was provided per The busiest periods are likely to occur when
or stepladder . The average vertical reach of meal served, and frozen walk-in space approxi- preparation containers are emptied for service

758
Commercial

RESTAURANTS AND EATING PLACES


Restaurant Seating

Fig . 1 Seat groupings around rectangular and circular tables.

Fig. 2 Banquette seating arrangements and limiting


dimensions including space for access and service .

Fred Lawson, Restaurant Planning and Design, The


Architectural Press, Ltd ., London, 1973 .

759
Commercial

RESTAURANTS AND EATING PLACES


Restaurant Seating

Abs. i Des. Comfort-


Min . Min. able
3-0 3-6 3-9
Ap Public circ'n I to to to
4-6
3-6 - 5--0 5--0
4--0 4-0
As Service aisle to to to
4-6 5-0 5-6
I-8 2-0 2-0
B To wall to to to
2-0 2-6 3-0
0 -- 6
C Between units to to I-0
8 I-0
1-8
2-3 2-4
Length to to to
2-0 2-4 _ 2-6
I-8 2-2 2-4
Width to to to
2-0 2-3 2-6

all dimensions in feet and inches

Abs. Des. Comforf-


Min. Min. able
'I-10 2-3 3-0
Ap Public circ'n to to to
4-6 5-0 5-0
3-0 3-6 3-9
As Service aisle to to to
3-6 4-0 4-0
0 4
C Between units to to 6
3 6 _
I-8 2-3 2-4
Length to to to
2-0 _ 2--4 2-6
1-8 2-2 2-4
Width to to to
2-0 2-3 2-6
" Lower range only if chairs, etc., do not project into aisle
Fig . 4 Table and chair units .

760
Commercial

RESTAURANTS AND EATING PLACES


Restaurant Seating

_
Abs. Des. Comfort-
Min. Min. able
Public I
AP circ'n_ 3-0 to 3-6 3-6 to 4-b 3 6 to 4-6
2- _ _ -- 2
Service
As 3-0

_IIITo wall _ 6 to I-0 10 to _I-0 _I- 0 to I-3


C Between
1-6 I-10 2-0
units
_Diameter _ 2-8 _ 2-10 2-10
,L Perimeter
per seat
1-10 I 2-0 2-2

*For seating units for more than 4 persons.


round tables are usually recommended ; diam-
eter depending on perimeter necessary to seat
required number .

Abs. I Des. Comfort- hAbs .


Min.
Des.
Min.
Comfort-
able
Min . Min. able

Service or pub. Service or pub.


2-0 to 3-6 2-6 to 4-6 3-0 to 5-0 3 .6 to 4-6 4-6 to 5-0 5-0 to 5-6
ci rc'n circ'n

ô To Wall 2-0 2-0 to 2-6 2-0 to 3-0


C Between units 3-0 to 3-6 3-6 to 4-0 3-9 to 4-0
C Between units 0 to I-0 1-0 I-6
Length 3-6 3-10 to 4-0 4-0
Length 3-6 3-10 to 4-0 4-0
Width I-8 to 2-0 2-0 to 2-3 2-4 to 2-6 Width I-8 to 2-0 2-0 to 2-3 2-4 to 2-6

Fill. 4 (continued) Table and chair units.

76 1
Commercial
RESTAURANTS AND EATING PLACES
Restaurant Seating

2 PERSONS FACE TO FACE


__ _
Abs. Des. Comfort--
2 PERSONS SIDE BY SIDE Min . Min . able
Service 2-6 3-0 3-6
Abs. Des. ! Comfort- A and pub.l to to to
Min. Min. able circ'n 3-0 4-0 - 5-0 --
Service 2 2._
A and pub. 2-6 3-0 3-6 Length 2-0 to 2--6
circ'n _ _ j _10- 2-6 _
Lsngfh 3--6 3-9 4-0 - --4- 5_-2 5-8
Width 3-0 3-3 3-6 Width to to to
Note : This type not ordinarily recommended. 5-6 5-6 5-10

dimensions in feet and inches

BOOTH FURNITURE HEIGHTS


_
-A6s. Des. Comfort.
Min . Min, able
H 3-0 to 3-6 3-6 +---0
4 PERSONS
Des. Comfort- S 1-5 to 1-6 I-5 to 1-6 1--6
Alas .
Min. Min. able
Service 2-6 3-0 3--6 2- 5 2-5 to 2-6 2-6
A end pub., to to to
circ'n 3-0 4-0 5--0 W 1-8 to 2-0 2-0 to 2-2 2-4 to 2-6
3-9 4-0
Length 3-b to to
4-0 4-2 __ Seat I-4 to I-5 I-5 to I-6 1-6 fo I-8
4-10 5--2 5--8
Width to to to Splay 0 to 0-3 0-2 to 0-3 0-31/2 to 0--4
5-6 5- 6 5-10
Fig. S Booths.

762
Commercial

RESTAURANTS AND EATING PLACES


Food Bars

STANDARD (straight) TYPE

I
Abs . Desirable
Min . Min .

X No cooking equipment I- 6 2- 0
X With cooking equipt . 2- 0 _2 -6
Y I person 2- 0 2-3
Y 2 or more persons 2- 6 _ 2-9 _
z _ I-10 2-0 Variations in Shape
E 9 __I-2 Usual Minimum
Ap 3. 6 4-6 A 2-6 to 3-6
B I- 0 I-2 B 2-6 to 4-6
CC I-10 2-0
C _- -2-9 to 5-6 dimensions in feet and inches

HEIGHTS

LEVEL FLOOR DROPPED FLOOR

Ra ng e of D imensions Range of Dimensions


Range of Dimensions
_B _ 3 .0 to 3 . 6
B __ __2-_6_'.?_3=_6_ 2 to-.3__.3_-_
_.1-_ K _ 2-4 to 2-10
Bill 3-0 to 3- 6 Work 2-4 to 2- 7 S __ I-6 to 2- I
N 7 to 10 $ 1 - 6 to 2- 6 X j I-2 to I- 3
to 2- 8 Work 2 .4 to 2- 6

Fig. 6 Food bars .

763
Commercial

RESTAURANTS AND EATING PLACES


Serving Units

SERVING TABLE (& sideboard)


Alos . Des. Comfort-
Min. Min. able
As Service only --
- P u -bI- ic----
circ'n
I 2-6
2-0
3-0.-
2-6
-3-6
---
3-0
Clearance to ad- 2-6
C 20 2-3
jacentunits --
Length I
- 42" is a~erdge .
Width

Display tables (Mrs d'oeuvres, etc.) usually 5' 0" x 2' 0" ;
(wines) . V V round

SERVING CART
---
fibs . Des.
Min, Min.
_As__ Service on ly __2-0 2-6
urn radius 30 V
6 Door, opening width 2-0 2-6

Approx . area when stored : 38" x 21 ;s - x 35"

TRAY STAND
Abs . Des. Comfort-
Min . Min . able
As Service _only_ 2-6 3-0 3-6
Ap Public ci rc'n 2-0 2-b 3-0
Clearance to ad- 2-3 2-6
C 2-0
jacenf units
"I
_ (tray)t
-, Depends on type of restaurant .
Width (tray)

Approx . area of stand, stored : 5" x 20" x 34"

WATER COOLER

Z. I
Abs Des. Comfort-
Min . able
As Service only 3-0 1 3-6
Ap Public ci 'n 1 2- 2-6 1 3-0
Clearance to ad- Can arrange on top or front
C jacenf units
Length Depends o-i capacity and if glass storage
Width included .

PW 7 Siamwip units.

764

You might also like