Lighting Calculation

initial
output No. of Lumens No. of
Rooms Area CU LLF Illumination Model (lumen) lamps/fix. produced Fixtures No of Fixtures
Maid's room 7.36 0.35 0.7 80 TCW097 2300 1 2403.27 1.0 1
Driver's room 7.084 0.35 0.7 80 TCW097 2300 1 2313.14 1.0 1
CR1 3.87 0.35 0.7 500 FBH031 2300 2 7897.96 1.7 2
Garage 20.0015 0.35 0.6 100 TCW097 3200 2 9524.52 1.5 2
Living room 27.685 0.45 0.7 100 FBH031 2300 2 8788.89 1.9 2
Kitchen 15.91 0.45 0.7 1200 TBS068 3200 3 60609.52 6.3 7
Hallway 4.95 0.35 0.7 100 MBS252 1200 2 2020.41 0.8 1
Laundry area 4.73 0.35 0.7 300 TCW097 3200 2 5791.84 0.9 1
Library 14.1968 0.45 0.7 500 TCW097 3200 2 22534.60 3.5 4
Open area 6.72 0.35 0.7 100 TCH086 2300 2 2742.86 0.6 1
Dining area 14.96 0.45 0.7 150 FBH031 2300 1 7123.81 3.1 4
Storage room 7.4 0.45 0.6 100 MBS252 3200 1 2740.74 0.9 1
                     
Master's
bedroom 19.2 0.45 0.7 100 TCW097 2300 2 6095.24 1.3 2
CR2 13.76 0.35 0.7 500 FBHO31 3200 2 28081.63 4.4 5
Girl's bedroom 12.87 0.35 0.7 100 TCW097 2300 2 5253.06 1.1 2
Boy's bedroom 10.88 0.35 0.7 100 TCW097 2300 2 4440.82 1.0 1
CR3 6.65 0.35 0.7 500 FBHO31 2300 2 13571.43 3.0 3
Guest room 10.44 0.35 0.7 100 TCW097 2300 2 4261.22 0.9 1
Playroom 4.64 0.35 0.7 100 FBHO31 2300 1 1893.88 0.8 1
Open space 5.6 0.35 0.7 100 FBHO31 2300 1 2285.71 1.0 1
Stairs 3.675 0.35 0.7 100 MBS252 1200 1 1500.00 1.3 2
WI1 1.35 0.35 0.7 300 FBH031 2300 1 1653.06 0.7 1
WI2 1.68 0.35 0.7 300 FBH031 2300 1 2057.14 0.9 1
WI3 1.68 0.35 0.7 300 FBH031 2300 1 2057.14 0.9 1
WI4 2.352 0.35 0.7 300 FBH031 2300 1 2880.00 1.3 2
WI5 0.9 0.35 0.7 300 FBH031 2300 1 1102.04 0.5 1