SPEED GOVERNORS 1

• SG-200andSG-300speedgovernorsaresafetydeviceswithmorethan
15options,coveringawiderangeofapplicationswiththesameproduct.

•Designedfor minimummaintenance,withinterchangeablespareparts.

•Speciallydesignedfor MRLapplication,butperfectlyadaptablefor MRwith


aprotectioncover.

•TrippingSwitchContactwithdifferentoptions.
•Encoder,forhighspeedapplications.
•Manualorremoteinterlocking.

Model SG-
SG-200 SG-
SG-300 SG-
SG-300B
TypeExamination
ATI/LD-VA/M156/06 ATI/LD-VA/M157/06
Certificate
PulleyDiameter 200mm 300mm
NominalSpeed Upto1.6m/s Upto1.75m/s 2,00
6,5mm 6,5mm / 8mm 6,5mm / 8mm
GovernorRope
6×19 6×19 / 8×19 6×19 / 8×19

ThyssenKrupp Elevator
Preliminary version Oct 2010 Manufacturing Spain
OPTIONS 2

TrippingSwitch:SafetySwitch,
safetycontactde-energizes
whenoverspeed governortrips.

ContactOptions:1NC+1NO,
2NC+1NO,2NC.

Technicalcharacteristics: ENCODER:extrainfoforexternaldevices,
• Voltage220VAC suchasrescuesystems.Theencoderhave
• I=1,5A. twosensorsformotiondirectiondetection.
• resolution: 36pulses/rev.
120pulses/rev.

Predisconnection Switch: Themachineisde-energized


beforethetrippingspeedwouldbereached.Mandatoryfor
speeds>1m/s,acctoEN81.1.
Thepre-disconnectionswitchmustberesetelectricallyby
meansofasolenoid(incaseofMRL).
Technicalcharacteristics:
• Voltage24VDC
• Máx.Current:0,4Amp
• ED40%.

RemoteTripping:Forcheckingthecorrectfunctioning
ofsafetygears.

Technicalcharacteristics:
• Voltage24VDC
• Máx.Current:2Amp
• ED40%

Blockingdevice:topreventunintendedmovements
ofthecar.Thissystemincludesautochecking function
viainductivesensor.
Technicalcharacteristics:
• Voltage12VDC
• Máx.Current:1,38Amp
• ED100%

ThyssenKrupp Elevator
Preliminary version Oct 2010 Manufacturing Spain
3

SpeedgovernorSelection

ThyssenKrupp Elevator
Preliminary version Oct 2010 Manufacturing Spain