Professional Documents
Culture Documents
You Got The Power.: Diesel Driven Ground Power Unit
You Got The Power.: Diesel Driven Ground Power Unit
You Got The Power.: Diesel Driven Ground Power Unit
DP_03_en_022020 Technical specifications and illustrations correspond with those at the time of printing. Subject to change.
HITZINGER Electric HITZINGER (UK) Ltd. HITZINGER Pte Ltd. HITZINGER USA
Power GmbH 50 Churchill Square 201 Joo Chiat Road #02-05 11764 Marco Beach Drive, Suite 4-6
AIRPORT TECHNOLOGIES
AVAILABLE APPLICATIONS OPTIONS Helmholtzstraße 56 Kings Hill, West Malling, 427472 Singapore Jacksonville, Florida, 32224
> Towable application > 28 VDC unit for single or 4020 Linz KENT, ME 19 4YU Singapore
> Motorised application simultaneous operation Austria United Kingdom
> Application for aircraft tow tractors - permanent load: 600 A Phone: +1 904 330 0267 Diesel Driven Ground Power Unit
- maximum load: 2500 A Phone: +43 732 381681-0 Phone: +44 1732 529 641 Phone: +65 31100042 Mobile: +1 904 518 9635
POWER RANGE > Modified protective separation (IT) Fax: +43 732 381681-4 Fax: +44 1732 529 642 Fax: +65 62141217 Fax: +1 904 575 4974
> D POWER 90 to 180 kVA according to DFS 400 Mail: office@hitzinger.at Mail: info@hitzinger.net Mail: singapore@hitzinger.at Mail: sales@hitzinger.us
> Individual customization on request Internet: www.hitzinger.at Internet: www.hitzinger.net Internet: www.hitzinger.at Internet: www.hitzinger.us
TECHNICAL DATA
> Voltage: 200/115 VAC STANDARDS VAT Identification No. ATU64944029
> Frequency: 400 Hz > ISO 6858 version 2 ARA License No. 22427
> SAE ARP 5015 Data Processing Registration No. 484121
ENVIRONMENT > DFS 400 Commercial Register No. 326415y
> Ambient temperature: > BS 2G 219
-30° C to +52° C > MIL-STD 704
> Relative humidity > EN 2282
up to 95 % > EN 61439
> Noise level: > EN 1915-1/-2
< 75 dB (A) @ 1m > EN 12312-20
> EN 61000-6-4
GUARANTEED POWER SIMPLY BRILLIANT TECHNICAL SPECIFICATIONS
The D POWER distinguishes itself through optimized economic and alternator efficiency. Minimized Economic efficiency, safety, and maximum flexibility are the main focus of our development strategy. We evalu-
maintenance costs, convenient serviceability and easy operation complete the product’s consistent ate the power of innovation according to the benefit it provides for our customer. “More power for less invest-
development strategy. We guarantee optimal power. ment and optimal handling” is our ethos.
GROUND POWER
Protection according to DIN 40050: IP 55 400 Hz control unit
the noise level is decreased as much as possible. Overload characteristics: 110 % for 60 min, 125 % for 5 min
TECHNICAL DATA DIESEL ENGINE
Make: DEUTZ TCD 2013, TCD 6.1, TCD 7.8, TCD 4.1, water-cooled
CUMMINS QSB5, QSB7, water-cooled
Exhaust emission level: EU COM IIIA / EU Stage V / US EPA Tier 4 final
INCREASED EFFICIENCY Engine speed: 1500 rpm / 1846 rpm / 2182 rpm
Engine electrics: 24 VDC
Due to the increased alternator efficiency and independent from the Diesel engine operation: 4-stroke in-line engine, common rail system
load profile, aircraft may also be powered as economically as possib- PERFORMANCE TORQUE CONSUMPTION
250 214
BEST SERVICEABILITY > lowest emissions > perfect access to maintenance-free to use operating data 50 800 206
> light-weight design absorbent glass mat batteries > user mode for operation & 00 600 204
1100 1300 1500 1700 1900 2200 n(min-1) 1100 1300 1500 1700 1900 2200 n(min-1) 1100 1300 1500 1700 1900 2200 n(min-1)
The modular design of the control unit simplifies all service works. > robust chassis > solid rubber tires service (user and expert mode)
> equal track width of the front > easy operation TECHNICAL DATA ALTERNATOR
Spaciously designed side panels enable optimized access.
and rear suspension results in: Make: HITZINGER SGE050C32K
- stabile driving conditions Efficiency: 92 % / 26 % / 22 %
- smallest turning radius/circle Model: 32 pole, self-controlled 3-phase internal pole synchronous alternator
WEIGHTS AND DIMENSIONS MEASUREMENTS
D POWER 90 ~2800 kg / 2600 kg 1792 x 1540 x 3970 mm (H x W x L)
D POWER 120 ~2800 kg 1792 x 1540 x 3970 mm (H x W x L) ~ 3970
~ 3508
~ 2209
D POWER 140 ~2900 kg 1792 x 1540 x 3970 mm (H x W x L)
USERFRIENDLY CONTROLS
2055
~ 1071
ECONOMIC EFFICIENCY SAFETY ERGONOMICS D POWER 180 ~2900 kg 1792 x 1540 x 3970 mm (H x W x L)
> lowest fuel consumption > lighting system enables diverse operating > The operating panel is well positioned as
The touch panel of the controller distinguishes itself via intuitive
> extended life cycle states to be indicated optically (LED) well as the aircraft supply cable for safe
~ 2223
user guidance. It is easily readable, even in direct sunlight, water and
~ 2010
~ 1170
~ 1752
~ 1477
> less wear and tear of major components > easy to read error log and swift handling.
dust proof, and suitable for adverse airfield conditions. Moreover, the
894
> drive-away lock if plug is not in the
769
> spaciously designed cable tray
13,7°
303
resistant touch screen can be operated conveniently with working
213
15°
defined position > defined position for aircraft supply cables ~ 1540
220 817 220
gloves.
1257
~ 879 ~ 2419
conditions