Forum Vijaya Mall, Chennai: Live Case Study

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 82

FORUM VIJAYA

MALL,CHENNAI
LIVE CASE STUDY
FORUM VIJAYA MALL ,CHENNAI
CLIENT Prestige Group
TYPE Mixed use comercial
YEAR OF COMPLETION 2013
ARCHITECT Thomas Associates
Structural Engineering Potential Services Consultants
MEP Engineering Potential Services Consultants
Landscape Peridian Consultants
LOCATION Vadapalani,Chennai
RETAIL AREA 650,000 sq ft
PARKING 3000 vehicles (Basement & MLCP –2basements and 8
side levels)
NO OF ANCHOR STORES 8
NO OF SCREENS 8 + 1 IMAX
AVERAGE FOOTFALL
50000

45000

40000

35000

30000

25000

20000

15000

10000

5000

0
Weekdays Weekands
Pre covid Present
Location
• Vadapalani- busy and commercial area in chennai
• Has bustling residential localities
• The place is renowned for its film studios, 19th century murugan temple and
its 6 storey mall (forum vijaya mall).
CONTEXT
It has two main abutting roads towards the east
entrance it has the 100 feet road
The south entrance is by the arcot road (25 ft).
N

100 ft road
SIMS HOSPITAL AND CAMPUS

HOTEL GREEN PARK

residential VIJAYA HOSPITAL


hospitals
commercial
MALL CATCHMENT
Next to the SRM campus vadapalani (8 mins from the mall)
Presence of residential neighbourhoods
Need for branded retail stores
4 min from the vadaplani
metro which runs
Through all major areas of
chennai.

5 ,min from the


vadapalani bus
depot
This projection did not provide
Enough shade as it is visible

CLIMATE DATA In the picture

Climate does not play a


major role inside the mall
since the mall is fully
airconditioned
Expect the south facade is covered by
Panels to avoid the warm sun from
Entering the mall.
TRAFFIC AND PARKING
ANALYSIS
TRAFFIC ANALYSIS

8 AM 12 PM

4 PM 10 PM
TRAFFIC ANALYSIS

TIME 8 AM 12 PM 4 PM 10 PM

WEEK DAYS SLOW MEDIUM MEDIUM FAST

WEEK ENDS SLOW MEDIUM FAST FAST

HOWEVER THE TRAFFIC IS HEAVY ON HOLIDAYS AND IN THE TIME OF FESTIVALS


AS THE MALL IS LOCATED ADJACENT TO THE ARCOT ROAD, IT INCREASES
THE TRAFFIC INFRONT OF THE MALL WHEN PEOPLE MOVE IN OR OUT
THROUGH THAT ENTRANCE
ROAD

FORUM PARK

APARTMENTS

BACK PARKING

CAB DROP OFF POINT


GREEN PARK
( HOTEL )

MALL WAY TO JAWAHARLAL


NEHRU ROAD

APARTMENTS

AUTO STANDS AND CAB DROP OFF

TRANSISION SPACE

ROAD WIDTH = 25m PEDESTRIAN PATH


ARCOT ROAD
CAR PATH

ROAD ACCESS CAB PATH

ENTRANCES
BASEMENT PARKING 2

BASEMENT PARKING 1

MALL

TWO WHEELER PARKING

PARKING EXIT PARKING ENTRY

BASEMENT PARKING
MALL

ENTRY RAMP
TWO WHEELER PARKING MALL ( LOWER GROUND FLOOR )

BASEMENT PARKING 1

BASEMENT PARKING 2

BASEMENT PARKING SECTION


ONE WAY MOVEMENT OF VEHICHLES

TOP LEVEL
STAIRS FOR
THE
PEDESTRIANS
TO ACCESS
THE TOP LEVEL

UP DOWN

RAMPS

DOWN UP

LOWER
LEVEL

MALL ENTRY

BACK PARKING PLAN (CAR)


STAGGERED FLOOR FOR ACCESS RAMP FOR PHYSICALLY
ONE WAY CIRCULATION CHALLENGED PEOPLE IN THE
EAST ENTRANCE
MULTILEVEL PARKING – CONCEPTUAL SKETCH
2 LEVELS IN PARKING IS 1 FLOOR IN THE MALL

ENTRY TO THE MALL


( ON THIS SIDE )

BACK PARKING SECTION


SPATIAL ANALYSIS
THE USUAL ENRTY TO THE LOWER GROUND
TOO CONJESTED HERE DUE TO THE: 10 A.M. 12 P.M. 2 P.M. 6 P.M. 8 P.M. 10 P.M.
FLOOR IS FROM THE ESCALATOR EXITS OF THE SUPER MARKET LOW

CONNECTING FROM THE UPPER GROUND ESCALATORS AND LIFT ACCESS


MEDIUM
(WHICH IS NEAR THE MAIN ENTRANCE) AND ALWAYS MOVEMENT THERE HERE
FROM THE SIDE ENTRANCE (CAB DROP OFF DUE TO THE ENTRY OF THE SHOPS
HIGH

POINT). VERY HIGH

TROLLEY LIFTS
ESCALATOR CONNECTING NO.OF PEOPLE IN THIS FLOOR AT EACH TIME
TO THE UPPER GROUND FLOOR

NO PEOPLE
MOVEMENT HERE
ONLY ESCALATOR TO
THE BASEMENT ARE
PRESENT
(AND PEOPLE USE
LIFTS TO THE BASEMENT)

SIDE ENTRY TROLLEY PATH


(CAB ENTRANCE )

HIGH PEOPLE TRAFFIC


BASEMENT TWO WHEELER
PARKING VERY LOW PEOPLE TRAFFIC
SLIGHTLY CONJESTED DUE TO:
ENTRY FROM THE UPPER GROUND
RESTROOMS ALWAYS MOVEMENT PRESENT

MEDIUM PEOPLE TRAFFIC

CIRCULATION - LOWER GROUND FLOOR PEOPLE CIRCULATION PATH


10 A.M. 12 P.M. 2 P.M. 6 P.M. 8 P.M. 10 P.M.

LOW
THE MAIN ENTRANCE IS MOSTLY ACCESSED MOSTLY CONJESTED THROUGHOUT THE DAY
DUE TO THE ATRIUM BEING THE MAIN FOCUS
BY THE PEDESTRIANS ENTERING THE MALL POINT AND ALSO DUE TO THE EVENTS THAT TAKE PLACE
MEDIUM

AND THE PEOPLE WHO COME BY AUTOS HIGH

VERY HIGH

NO.OF PEOPLE IN THIS FLOOR AT EACH TIME


THERE IS ALWAYS MOVEMENT AROUND THE
ATRIUM (CORRIDOR SPACE), MAINLY TO
ACCESS THE SHOPS WEST SIDE ENTRANCE

MAIN
ENTRANCE
( ENTRANCE FROM THE
MAIN ROAD)

SINCE IT IS PRESENT ATTHE THE ATRIUM BEING THE MAIN HIGH PEOPLE TRAFFIC
MAIN ENTRANCE OF THE MALL SPOT THE LIFT NEAR IT,IS
THERE ARE TEMPORARY STALLS CROWDED MOST OF THE TIME
BUT THERE IS MOVEMENT . VERY LOW PEOPLE TRAFFIC
PRESENT ,PEOPLE STOP TO BUY OR
THE PROCESS OF CHECKING VIEW THOSE PRODUCTS
ALWAYS MOVEMENT PRESENT

MEDIUM PEOPLE TRAFFIC

CIRCULATION - UPPER GROUND FLOOR PEOPLE CIRCULATION PATH


10 A.M. 12 P.M. 2 P.M. 6 P.M. 8 P.M. 10 P.M.

LOW

MEDIUM

HIGH

THERE IS ALWAYS MOVEMENT HERE AS


THE PEOPLE ENTER INTO THE SHOPS VERY HIGH

NO.OF PEOPLE IN THIS FLOOR AT EACH TIME

THE CORRIDOR SURROUNDING THE HIGH PEOPLE TRAFFIC


ATRIUM IS ALSO USED AS A GALLERY
VIEW TO THE UPPER GROUND FLOOR VERY LOW PEOPLE TRAFFIC

ALWAYS MOVEMENT PRESENT

MEDIUM PEOPLE TRAFFIC

CIRCULATION - FIRST FLOOR


PEOPLE CIRCULATION PATH
10 A.M. 12 P.M. 2 P.M. 6 P.M. 8 P.M. 10 P.M.

LOW

MEDIUM

HIGH
THERE IS ALWAYS MOVEMENT HERE AS
THE PEOPLE ENTER INTO THE SHOPS VERY HIGH

NO.OF PEOPLE IN THIS FLOOR AT EACH TIME

THE CORRIDOR SURROUNDING THE


ATRIUM IS ALSO USED AS A GALLERY HIGH PEOPLE TRAFFIC
VIEW TO THE UPPER GROUND FLOOR
VERY LOW PEOPLE TRAFFIC

ALWAYS MOVEMENT PRESENT

MEDIUM PEOPLE TRAFFIC

CIRCULATION - SECOND FLOOR PEOPLE CIRCULATION PATH


10 A.M. 12 P.M. 2 P.M. 6 P.M. 8 P.M. 10 P.M.
THE CORRIDOR SPACE IS ALSO USED
LOW
AS A GALLERY HERE BUT THE NO.OF
PEOPLE IS COMPARITIVELY LESS MEDIUM
THE THEATRE IS CROWDED ALL THE TIME THAN THE PREVIOUS TWO FLOORS
( BEFORE COVID-19) ( DUE TO LARGER HEIGHT FROM THE HIGH

THE PLACE TO BUY TICKETS, FOOD ARE ALL UPPER GROUND FLOOR)
VERY HIGH
PRESENT HERE ,SO THERE IS CROWD ALL THE TIME

NO.OF PEOPLE IN THIS FLOOR AT EACH TIME

THE FOOD COURT IS ALWAYS CROWDED HIGH PEOPLE TRAFFIC


DUE TO THE GOOD AMBIENCE AND ALSO THE VARIETY
OF FOOD AVAILABLE IN ONE PLACE VERY LOW PEOPLE TRAFFIC

ALWAYS MOVEMENT PRESENT

MEDIUM PEOPLE TRAFFIC

CIRCULATION -THIRD FLOOR PEOPLE CIRCULATION PATH


10 A.M. 12 P.M. 2 P.M. 6 P.M. 8 P.M. 10 P.M.

LOW

MEDIUM

THIS IS THE LEAST USED FLOOR IN THE MALL HIGH


THE ONLY REASON PEOPLE COE TO THIS FLOOR
IS FOR THE FUN CITY VERY HIGH

NO.OF PEOPLE IN THIS FLOOR AT EACH TIME

HIGH PEOPLE TRAFFIC

VERY LOW PEOPLE TRAFFIC

ALWAYS MOVEMENT

PRESENT MEDIUM PEOPLE

CIRCULATION - FORTH FLOOR TRAFFIC


PEOPLE CIRCULATION PATH
ESCALATORS PLACED HERE DUE TO THE SPAR IS THE MAIN SUPER MARKET IN FORUM
MAIN ENTRANCE ,SO THE THE LOWER THERE ARE PEOPLE PRESENT HER MOST OF THE TIME
GROUND FLOOR IS ACCESSED

SIDE ENTRANCE PLACED IN THE


LOWER GROUND FLOOR BECAUSE
OF SHOPS PRESENT THERE
( OTHER TWO ENTRANCE ARE PRESENT
IN UPPER GROUND FLOOR )
THESE SHOPS ARE PLACED HERE BECAUSE OF SPAR
PEOPLE VISIT SPAR , HAVE TO PASS THROUGH
THESE SHOPS

ZONING - LOWER GROUND FLOOR


TEMPORARY STALLS PLACED HERE BECAUSE
PEOPLE MOVE TOWARDS THE ATRIUM SO
ANCHOR SHOPS PLACED NEAR THE THEY HAVE TO PASS THROUGH THESE SHOPS
ENTRANCE ANCHOR SHOPS PLACED NEAR THE
ATRIUM FOR MOE PEOPLE ACCESS

SHOPS PLACED HERE BECAUSE ITS ON THE CIRCULATORY SPACE AROUND THE ATRIUM
WAY TO THE ATRIUM

ZONING - UPPER GROUND FLOOR


ANCHOR SHOPS PLACED NEAR ATRIUM
THE ANCHOR SHOPS ARE PLACED ON THE ENDS OF THE PLAN ( ALSO ALL FLOORS CAN BE VIEWED FROM
SO THE THERE IS PEOPLE CIRCULATION AROUND THE MALL THE UPPER GROUND FLOOR )

ANCHOR STORES PLACED ATTHE CORNER


AS THE IT IS A FOUS POINT AND PEOPLE HAVE
PASS THROUGH VARIOUS SHOPS

SMALLER SHOPS PLACED BETWEEN THE


ATRUIM AND THE ANCHOR SHOPS THE CORRIDOR SURROUNDING THE ATRIUM
IS MAINLY FOR CIRCULATION AND ALSO AS A VIEWING
GALLERY TO THE ATRIUM

ZONING - FIRST FLOOR


THE ANCHOR SHOPS ARE PLACED ON THE ENDS OF THE PLAN
SO THE THERE IS PEOPLE CIRCULATION AROUND THE MALL

SMALLER SHOPS PLACED BETWEEN THE


ATRUIM AND THE ANCHOR SHOPS THE CORRIDOR SURROUNDING THE ATRIUM
IS MAINLY FOR CIRCULATION AND ALSO AS A VIEWING
GALLERY TO THE ATRIUM

ZONING - SECOND FLOOR


THEATRES AN FOOD COURT ARE THE MOST VISITED PLACES IN A MALL
SO THEY ARE PLACED IN THE THIRD FLOOR

THEATRE PLACED HERE AS IT IS DOUBLE STORY HIGH

ZONING -THIRD FLOOR


RESTROOMS PLACED
ON THE OUTER SIDE
OF THE BUILDING FOR
VENTILATION

RESTROOMS ARE PLACED


ALMOST AT EQUAL DISTANCE
FROM EVERY PLACE IN THE MALL

RESTROOMS
RESTROOMS PLACED INSIDE SO
THATTHE RESTROOMS ARE
NOT SEEN FROM THE INTERIOR
OF THE MALL SERVICE LIFTS

RESTROOMS AND SERVICE LIFTS LOADING BAY


THE SERVICE LIFTS ARE PLACED IN SPCES WHICH
HAS ROAD AND PARKING ACCESS
THEY ARE USED FOR THE LOADS FOR THE SHOPS

RESTROOMS

SERVICE LIFTS
RESTROOMS AND SERVICE LIFTS
LOADING BAY
THERE ARE NO RESTROOMS
IN THE 4th FLOOR

SPAR AND THE FOOD COURT


HAVE THE SAME LOADING
BAY

RESTROOMS

RESTROOMS AND SERVICE LIFTS


LOADING BAY
FOCUS AND FOCUS POINTS

PAUSE POINTS PAUSE POINTS


ATRIUM

Bow string truss to support the curved atrium roof

• This is the main focus point in the mall


• Many events and exhibitions happen in this space

Central atrium is bright Palazzo atrium is not as bright


as the central atrium
It might be because exiting
the dark theatres to a bright
place can strain the eye
THE SHOPPING PARTS ARE PLACED
IN THE BOTTOM FLOORS

THE THEATRE AND FOOD COURT


ARE ONE OF THE MOST MAIN
PLACES PEOPLE GATHER IN A
MALL SO IT IS PLACED AT A TOP
FLOOR SO PEOPLE PASS THROUGH FUNCITY
THE SHOPPING ZONE OF THE MALL

THEATREAND FOOD COURT

ELECTRONICS AND TOYS

CLOTHES AND ACCESSORIES


SHOPPING
AND RESTRAUNTS

ZONING - FLOOR WISE


SHOP ANALYSIS
STORE SIZES RENT
ANCHOR STORES ARE THE STORES WHICH DRIVE IN
THE CROWD .SO PER SQ FT RENT OF ANCHOR STORES
IS LESS THAN THE OTHER STORES AS THE OTHER
STORES BENEFIT FROM THE CUSTOMERS WHO COME
TO THE ANCHOR STORES.

20000-40000 sq ft 150- 300 sq ft


800-1500 sq ft 45-130 sq ft

ANCHOR STORES MEDIUM SIZE STORES LARGE STORES KIOSKS


ANCHOR STORES - 8
Has come instead of Auchan which
was present during the first years of
the mall .It was also Chennai’s Forum Mall's food court
largest hypermarket at the time of named as Via South indicat
completion with an area of 1 lakh es that most of the food
square feet stalls here have southern
blend into their food.
Seating capacity - 650
This mall distinguishes itself by
being local by housing Chennai-
based brands in the mall such
as RmKV, Nalli, and regional brands
like Lifestyle .

SPI CINEMAS
(Parent company
PVR Cinemas)
SHOP PLACEMENT SIMILAR SHOPS

➢ SIMILAR SHOPS ARE PLACED NEXT TO EACH OTHER


FOOD SHOPS
➢ FOOD OUTLETS AT THE CORNERS – SHOPS AT THE CORNER
ARE REMEMBERED EASILY THAN THE ONES IN THE MIDDLE SERVICE LIFT
THE MAJOR OUTLETS ALSO HAVE ACCESS TO LOADING BAY​ FROM LOADING
BAY
UPPER GROUND FLOOR
FIRST FLOOR
2ND FLOOR
VIA SOUTH DINING
TABLES
RMKV INTERIOR HAMLEYS RMKV KIDS
SECTION

SHOP INTERIORS - WERE PERSONALISED


ADVERTISEMENTS CAN BE SEEN IN
• Façade
• Pylons
• Dropdowns
• Elevator Underbellies
• Backlit signage
• LED Screens
• Entry Arches
• Cubes
FIRE SAFETY
FIRE EXITS

NUMBER OF FIRE EXITS IN LOWER GROUND - 8


NUMBER OF FIRE EXITS IN 1ST 2ND AND 3RD EACH - 9
NUMBER OF FIRE EXITS IN 4TH FLOOR - 5

STANDARDS
EXTERNAL STAIR CASE

THREAD - 2000 mm
RISER - 160 mm
SLOPE - AROUND 40

MATERIAL USED – GRANITE

COULD HAVE USED CONCRETE INSTEAD


LIFTS
THERE IS ONE LIFT JUST AFTER THE
ENTRANCE AND THERE ARE 2 LIFTS IN THE
ATRIUM

LIFT CAPACITY – 20 PEOPLE

THE LIFTS IN THE ATRIUM ARE MADE OF


TINTED GLASS WHICH ALLOWS VISUAL
CONNECTIVITY AND HELPS PEOPLE WITH
CLAUSTROPHOBIA
ESCALATORS
THERE ARE 4 ESCALATORS IN THE LOWER
GROUND FLOOR AND 6 IN THE GROUND
FLOOR AND THE NUMBER OF ESCALATORS
IS AGAIN REDUCED TO 4 IN THE ABOVE
FLOORS AND 4TH FLOOR HAS ONLY 2 OF
THEM
FIRE ESCAPE ROUTE PLAN- MAX
FIRE ESCAPE ROUTE PLAN- LIFESTYLE (GROUND FLOOR)
FIRE ESCAPE ROUTE PLAN- LIFESTYLE (FIRST FLOOR)
WESTSIDE EVACUATION PLAN (GROUND FLOOR)
WESTSIDE EVACUATION PLAN (FIRST FLOOR)
MATERIAL
• RCC FRAMED STRUCTURE • AEROCON PARTITION WALLS –
• DOUBLE GLAZING Partitions made according to the client’s
• GLASS STOREFRONTS needs. If two shops are to be combined the
partition walls can be easily taken down
• FLOORING
• COLUMNS – Are mostly clad
MARBLE – Due to its durability
and easy maintenance. Ceramic
tiles are brittle and break easily

Clad with granite till 1.7 m Steel clad walls


to prevent stains
• CEILING

GYSPUM BOARD SPAR FOODC OURT HAMLEYS


CEILING - In corridors COFFERED CEILING – In SPAR and food court – Due to its sound absorption feature and its
and shop interiors ability to create an illusion of height
Services are exposed in Spar , food court and parking. As these are places which provide the
essentials it might not be necessary for them to look as elegant as the other stores
AN EXAMPLE OF BOWSTRING TRUSS

VIEW OF THE ATRIUM

TYPE OF TRUSS: BOWSTRING TRUSS


MATERIAL USED: STEEL
TOP AND BOTTOM CHORDS : STEEL TUBES
WEB MEMBERS : STEEL I SECTION TRUSS PROFILE
OTHER FEATURES :

In the 3rd and 4th floor, the


height of the glass railing in
the corridor is higher than
those in the lower floors for
safety purpose.
LIGHTING
Lighting for a mall
• Shopping mall lighting is considered one of the most mature and rapid increase areas of LED
applications.
• The shopping mall is not only a place to buy goods, but also to create an environment suitable for
people relax. The lighting effect is so important there, and the LED lighting has good performance
to achieve above .
• However, whether the LED can be more important in the lighting market it needs to be based on
the specific lighting environment and the humanized needs of consumers, and refine the various
performance parameters and lighting effects of each product.
• Shopping mall lighting design should focus on the behavior of customers to purchase goods,
according to the customer’s visual requirements and the characteristics of various products, the
space in which each product is located, scientific design, and to make customers feel comfortable
Visual effects.
• At the same time, reasonable illumination (we also call it brightness), good color reproduction,
suitable brightness distribution, and comfortable visual environment; through reasonable lighting
design, customers can attract attention to the goods and stimulate customers’ desire to buy.
• Let’s explain the detail of the lighting needs and design points in different areas of the mall.
First, illuminance, color temperature can affect
people’s psychological feelings
• Lighting not only has the function of illuminating, but also affects people’s psychology: the higher
the color temperature, the more refreshing the feeling will be, and the lower the temperature,
the warmer you feel. For example, when you see red or yellow, you will think of apples and
oranges. Red, yellow, sour and sweet, and enhance appetite; but black green, blue-green make
you feel bitter, will reduce appetite.
• The effects of different illumination and color temperature on people’s psychological reactions
are very different.
• The purpose of store lighting is to attract consumers’ interest through “commodity visualization”
by providing appropriate lighting and illumination, color temperature, color rendering and
brightness changes for different areas , and to communicate with customers through silent
language.
• In order to properly display the products in front of the customer, it is very important to properly
use the corresponding light to attract the customer’s attention and trigger the customer’s desire
to purchase.
• The light in the store space can be considered from the two directions of “environment light”
which is an overall impression of the space and “light of goods” which effectively display the
effect of the product.
Second, the areas of the mall require the
different lighting
• Different types of shopping malls and different area of shopping malls have
different requirements for lighting effects, so the key of their
lighting design is also different.
• Now, is it the right opportunity for LEDs to enter the base lighting of the
market as a new generation of light sources?Most of the experts believe
that commercial lighting is the first general lighting application area
for LEDs.
• Improving luminous flux, reliability and cost performance is the key to its
rapid intervention. The lighting of the mall can be further refined
according to different occasions, and the requirements for lighting of
different commodities are also different.
Lighting in parking area/Basement
• The basement parking area was lit with half hanging 36 watts tube
lights all over.
• Where as the other levels also had light but it was lit during the
day time.

Day light in Hanging tube


The upper Lights in the
Levels. Basement.
THE ATRIUM
• The has a bright diffused day light which is enough for the whole atrium space
• During night it has led down lights focusing the atrium.
• The small atrium does not diffuse much life the corridors had artificial lights
turned on even during the day.

The smaller atrium


With palazzo title view

Atrium at 4 pm
Led down lights
The atrium
Lighting in clothing areas
• The high color rendering LED spotlights and LED downlights can
effectively solve these problems.

Lighting inside
Peter England Inside lifestyle
LED spot lights Ceiling recessed lights
Corridor lighting
• Corridors had warm white 22 watts light
• The lights in the corridors adjacent to the atrium area were used only in the evening as the corridors had
enough lighting coming through the atrium some had small lights turned on.
• The corridors surrounding the smaller atrium doesn’t have enough day light
• The artificial lights were lit during the day time also.

Corridors surounding
Corridors surrounding the atrium during day
Corridor near the exterior the outer atrium during day
Palazzo lighting
• Palazzo's had small {15watts} warm
white ceiling recessed lights as they
match the finishes of the surrounding
and also chandliers for aesthetics.
• The lighting was not too bright and not
too dull.
• Source of day light is the small atrium.
Other lighting
Surrounding the atrium it had
wall fixed box lights along the
corridor
• Food court in the place had fancy hanging lights with enough lighting
and with a illuminance of 150lux which creates a good ambience for
the users.
All other shops had their own false ceiling
patterns and fancy lights inside.

Lighting inside
A restaurant

Lighting inside RMKV


THEATRE
THEATRE – PALAZZO
CINEMAS
• 8 screens + 1 IMAX
• Capacity – 2200 approx.
• Renaissance themed
ENTRY/EXIT
SCRREN 9 THEATRE – BASIC ZONING
SEATING
PROJECTOR ROOM

SCREEN

EMERGENCY EXIT EMERGENCY EXIT


THEATRE SECTION
PROJECTOR ROOM

(14m FOR IMAX)


SCREEN
STAIR DIMENSIONS

Folding type stairs so place


for movement is more
Curtains give a vintage feel and also acts as sound absorbers
INTERNAL LOAD DISTRIBUTION

LATERAL
LOAD

INCREASED BEAM DEPTH

BASEMENT AREAS

FOOTING

COLUMN SIZES :
Square columns – 1m*1m
Circular columns in the atrium – 1.25 diamater
Views of the mall at night

Arcot road view The Atrium at night


View from JAWAHARLAL NEHRU road

You might also like