Features: Deepseaelectronics J1939ENABLED Amfand Instrumentation
Features: Deepseaelectronics J1939ENABLED Amfand Instrumentation
Relay outputs Five DC positive outputs Crank/Crank rest timers Built in Governor Control
are provided, one for Fuel Solenoid and Engage attempt and manual crank Fully Isolated
one for Start output, the remaining three limit timers Minimum Load Impedance:
being user configurable. Additionally two 1000 Ω
volt free contacts for mains and Safety on delay timer
Gai nVol ts0–10VDC
generator switching device control are Warm-up timer Offset Volts + / - 10V DC
also provided. The configurable relay
functions can be selected from a range Cooling timer
of 100+ different functions, conditions or ‘
Ener
giset
ost
op’
hol
dti
mer Built in AVR Control
alarms. Additional output relays can be Fully Isolated
added by means of up to two 157 Relay Pre-heat timer / Pre-heat bypass Minimum Load Impedance:
Expansion Modules. A total of 21 timer 1000 Ω
outputs are available with full expansion Smoke limiting control timers Gai nVol ts0–10VDC
of the 5520 Module. This allows the Offset Volts + / - 10V DC
module system to be incorporated into Fail to stop timer
existing telemetry or Building
Over-speed overshoot timer
Management Schemes via volt-free
contacts. Breaker pulse control timers
Refer to appropriate manuals for details.
DC Battery alarm delay timers NOTE
Sync/Fail to Sync timer An Automatic Start multi set comms
version of the 5520 is also available:
Model 5510.
Please refer to Deep Sea Electronics
for details
SYNCHRONISING
T ELEMET RY AND LOAD CONTROL
Complex configurations can be saved
The 5520 module provides the user with
and loaded from disk or output to a
the option of full telemetry facilities via
printer for reference. Diagnostic facilities Synchroscope with auto sync
the optional communications software.
allow for fault finding and monitoring control.
The module can be either connected to
during test and installation. Volts and Frequency matching
the PC using the 810 interface or via a
Phase angle and Phase rotation
suitable modem. RS232 or RS485
indication.
available.
Dead bus sensing
TM
The PC software is MS-Windows Multi-set load demand operation
based, and allows the operator to control BUILT-IN FUNCTIONS KW and Kvar load sharing with
the module from a remote location. multiple generators.
Alternator Under/Over Volts Direct communication from the
The remote operator can also view the Warning/Shutdown module to the governor and
instrumentation, alarm and data log Alternator Under/Over Freq. AVR.
details, and the relay and input status. Warning/Shutdown KW export when in parallel with
All access is password controlled so Under/Over Speed the mains supply.
unauthorised operators cannot log onto Warning/Shutdown
the system. Low Oil Pressure
Warning/Shutdown
Additionally in the event of the module High Engine Temp
detecting an alarm condition, it will initiate Warning/Shutdown
a modem dial out to the host PC to High/Low Battery Volts Warning
inform the remote operator of the Over-current Warning/Electrical
problem, giving identification of the Trip/Shutdown
module followed by the alarm event and Reverse Power Electrical
the time and date of occurrence. Trip/Shutdown.
ENVIRONMENT AL
Phase sequence Electrical T EST ING ST ANDARDS
If using a GSM modem, the module is Trip/Shutdown.
also able to send text messages to a Earth Fault Shutdown. Electromagnetic Compatibility
GSM cell phone to indicate gen-set, site Short Circuit Fault Electrical BS EN 50081-2 EMC Emission
and alarm condition. Trip/Shutdown Standard for the Industrial Environment
Adjustable crank cycle/attempts
Maintenance due alarm function BS EN 50082-2 EMC Immunity
EVENT CAPTURE External remote start input (On Standard for the Industrial Environment
load/Off load/on load demand)
The standard module features event Built in Exercise Scheduler Vibration
capture facilities, this records the last Magnetic Pick-up or Alternator BS EN 60068-2-6 Ten sweeps (up and
25 shutdown alarms allowing the speed monitoring back down) at 1 octave/minute in each
operator to view the recent operating Event Logging of Shutdown of the three major axes.
history of the module to assist in fault Alarms 5Hz to 8 Hz @ +/-7.5mm constant
finding, etc. Full Remote Control and displacement.
Telemetry. 8Hz to 500 Hz @ 2gn constant
Graphic LCD Display for true acceleration
Event Log: Multi-lingual use
Multiple Language Display Temperature
options available. Cold:
Event Log 9 Digital inputs - Fully user
0
BS EN 60068-2-1-to -30 C
configurable Hot:
0
19 Jan 2005 16:12:44 5 Configurable relay outputs BS EN 60068-2-2 to 70 C
(100+ Control functions)
Low Water Level LCD Back-lighting for low light Humidity
level operation BS EN 2011 part 2.1 93% RH @ 400 C
System lock input for 48 hours
Load switching control push-
button inputs Shock
CONF IGURAT ION BS EN 60068-2-27 Three half sine
Security via PIN Number
restricted access shocks in each of the three major axes
Many settings can be adjusted by means SMS messaging capability with 15gn amplitude. 11mS duration.
of the module front panel configuration suitable GSM Modem
utility. Limited configuration from front Electrical Safety
panel - including user language BS EN 60950 Low Voltage
The PC based configuration software selection Directive/Safety of information
allows for fast, simple and secure technology equipment, including
configuration of module parameters. electrical business equipment.
Utilising the P810 interface to provide a
safe isolated link to the PC, changes can Deep Sea Electronics reserve the right to change
specification without prior notice.
easily be made to the system by
authorised personnel. Access is PIN
number protected.
CASE DIMENSIONS
172mm [6 3/4"]
57mm [2 1/4"] 240mm [9 1/2"]
Panelcut
-out220mm x160mm (
8.7”x6.
3”)