Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Contruction joint waterstops,

internal
• Special types

PVC-P Total Width of Thickness Width of Height of


Standard Quality width expansion of expan- sealing anchoring
part sion part part part

a b c s f

Construction joint waterstops, externally reinforced with fixing loops:

SFA 20 200 75 3 62.5 15


SFA 24 240 70 3,5 85 15
SFA 32 320 110 4 105 15

Tricomer Total Width of Thickness Width of Height of


DIN 18541, part 2 width expansion of expan- sealing anchoring
part sion part part part

a b c s f

Construction joint waterstops, externally reinforced with fixing loops:

A 200 SF 200 75 3,5 62.5 15


A 240 SF 240 70 4 85 15
A 320 SF 320 110 5 105 15

Construction joint waterstops, thick sections:

A 260 TS 260 113 9 72.5 24


A 320 TS 320 165 10 77.5 26

Elastomer (rubber) Total Width of Thickness Width of Height of


DIN 7865 width expansion of expan- sealing anchoring
part sion part part part

a b c s f

Construction joint waterstops with steel plates:

FS 270 270 60 7 105 22


FS 310 310 80 8 115 22

9
Expansion joint waterstops,
external

PVC-P Total Width of Web Sealing ribs


Standard Quality width expansion thickness
part Height Number
a b c f N

DF 19 190 92 3,5 16 4

DF 24 240 90 4 20 4
DF 24/2 240 90 4 25 4
DF 24/3 240 104 4,5 34 4

DF 32 330 104 4 20 6
DF 32/2 330 104 4 25 6
DF 32/3 330 104 4,5 34 6

DF 50 500 124 4 20 8
DF 50/2 500 124 4 25 8
DF 50/3 500 124 4,5 34 8

Tricomer Total Width of Web Sealing ribs


DIN 18541 width expansion thickness
part Height Number
a b c f N

DA 240 240 90 4,5 20 4


DA 240/2 240 90 4,5 25 4
DA 240/3 240 104 5 35 4

DA 320 330 104 4,5 20 6


DA 320/2 330 104 4,5 25 6
DA 320/3 330 104 5 35 6

DA 500 500 124 4,5 20 8


DA 500/2 500 124 4,5 25 8
DA 500/3 500 124 5 35 8

Elastomer (rubber) Total Width of Web Sealing ribs


DIN 7865 width expansion thickness
part Height Number
a b c f N

AM 250 250 100 6 31 4


AM 350 350 100 6 31 6
AM 500 500 150 6 31 8

DIN 7865 part 2

AM 250-2 250 100 5.5 36 4


AM 350-2 350 100 5.5 36 6

10
Expansion joint waterstops, external
Angle type profiles

PVC-P Total Width of Web Sealing ribs


Standard Quality width expansion thickness
part Height Number
a1/a2 b1/b2 c f N

DF 24 edge A 146/131 71/55 4 20 4


DF 24 edge W 146/131 71/55 4 20 4

DF 32 edge A 192/176 79/63 4 20 6


DF 32 edge W 192/176 79/63 4 20 6

A = external anchors
W = internal/external anchors

Tricomer Total Width of Web Sealing ribs


DIN 18541 part 2 width expansion thickness
part Height Number
a1/a2 b1/b2 c f N

DA 240 edge A 146/131 71/55 4.5 20 4


DA 240 edge W 146/131 71/55 4.5 20 4

DA 320 edge A 192/176 79/63 4.5 20 6


DA 320 edge W 192/176 79/63 4.5 20 6

A = external anchors
W = internal/external anchors

11
Construction joint waterstops,
external

PVC-P Total Width of Web Sealing ribs


Standard Quality width expansion thickness
part Height Number
a b c f N

AF 19 190 92 3.5 16 4

AF 24 240 90 4 20 4
AF 24/2 240 85 4 25 4
AF 24/3 240 104 4.5 35 4

AF 32 330 104 4 20 6
AF 32/2 330 104 4 25 6
AF 32/3 330 104 4.5 35 6

AF 50 500 124 4 20 8
AF 50/2 500 124 4 25 8
AF 50/3 500 124 4.5 35 8

Tricomer Total Width of Web Sealing ribs


DIN 18541 width expansion thickness
part Height Number
a b c f N

AA 240 240 90 4.5 20 4


AA 240/2 240 90 4.5 25 4
AA 240/3 240 104 5 35 4

AA 320 330 104 4.5 20 6


AA 320/2 330 104 4.5 25 6
AA 320/3 330 104 5 35 6

AA 500 500 124 4.5 20 8


AA 500/2 500 124 4.5 25 8
AA 500/3 500 124 5 35 8

Elastomer (rubber) Total Width of Web Sealing ribs


DIN 7865 width expansion thickness
part Height Number
a b c f N

A 250 250 100 6 31 4


A 350 350 100 6 31 6
A 500 500 150 6 31 8

DIN 7865 part 2

A 250-2 250 100 5.5 36 4


A 350-2 350 100 5.5 36 6

12