damaged, the electric current may pass through the air, causing an electric arc. Arcs
generate heat which can cause fires and they also pose an electrocution risk to
those working near them. As PV systems age and connectors and cables degrade,
requiring the ability to detect and terminate an arc through inverter shut down.
The system has to remain shut down until an installer has checked the site and
replaced any components if needed. Only then can the system be manually
restarted.
In Europe, the IEC or EN product standard for arc fault detection is on the way.
Since the risk of arcs in PV systems exists everywhere, arc fault detection is
Growatt AFCI (arc fault circuit interruption) module is developed, tested and certified
AFCI function as default, for the EU model inverter, the AFCI function is optional for
When configure inverter on-site, you can use the local configure tool USB-WiFi and
Installer can use OSS account to do the AFCI function setting remotely if inverter is
monitored online. The AFCI function setting is from inverter setting page.
The inverter performs an automatic self-test of AFCI function each time the inverter
turn on, this is self-test, and during inverter operation, when there is arc happened,
inverter will stop working, and give error information on LCD and monitoring
platform. Below table is the error information and solution, if the DC cable, panels
connection with no problem, and restart inverter the error still there, please contact
inverter. inverter.