Ujian Akhir Semester

Semester Ganjil Tahun Ajaran 2020/2021


PROGRAM STUDI SISTEM PEMBANGKIT ENERGI
DEPARTEMEN TEKNIK MEKANIKA DAN ENERGI
POLITEKNIK ELEKTRONIKA NEGERI SURABAYA
Kampus PENS Raya ITS Keputih Sukolilo, Surabaya 60111
FM-VVS.01.Rev.01
Mata Kuliah : Penukar Kalor 2 Dosen : Rif’ah Amalia
Kelas : 3SPE-A/3SPE-B Sifat : Open Book
Durasi Waktu/Jam : 90 minutes/13.00-14.30 Hari / Tgl : Rabu, 6 January 2021
Pelaksanaan

Prayer before work….

20,000 lb/h of saturated cyclohexane vapor will be condensed at 182◦F and 16 psia using a tube bundle
containing 147 tubes arranged for a single pass. The tubes are 1.0-in. OD, 14 BWG with a length of 20
ft. Physical properties of cyclohexane at these conditions are given in the table below, and all properties
may be assumed constant at these values. For the purpose of this problem, the effects of condensate
subcooling and interfacial shear are to be neglected. Calculate the condensing-side heat-transfer
coefficient for the following cases:
(a) The tube bundle is vertical and condensation occurs inside the tubes.
(b) The tube bundle is horizontal and condensation occurs outside the tubes.
( c) If the condenser is oriented horizontally and the cyclohexane condenses inside the tubes. At a
position where the quality is 50%, determine the flow regime use the method of Breber et al.
Property Liquid Vapor
ρ (lbm/ft3) 45 0,2
μ (cp) 0,4 0,0086
Cp (Btu/lbm.0F) 0,45 -
K (Btu/h.ft.0F) 0,086 -
σ (lbf/ft) 0,00124 -
λ (Btu/lbm) 154 -
Pr 5,063 -

--Thank You--