Pipe Size Calculation:

Flow Rate 1000 m3/day


41.66667 m3/hr
0.011574 m3/Sec
Assumed Pump Suction Velocity 0.8 m/Sec
Calculated Pipe Suction Diameter 0.135757 m
Provided Pipe Suction Diameter 0.15 m
150 mm
Assumed Pump discharge Velocity 1.8 m/Sec
Calculated Pipe discharge diameter 0.090505 m
Provided Pipe discharge diameter 0.1 m
100 mm
Atomospheric Tanks
Dimensions:
Width =
Length
Height
Flowing Medium
Density
Volume of the Tank
Weight(Mass) of the Medium
Force(F)

Pressure(P)
One Side Width Wall Area
Pressure(P)

Plate Thickeness(t)
Where
t
d
P

J
Hydraulic Radius rH
Hydraulic Diameter d
f

Plate Thickeness

Round figure Approximately


3
3.5
5
Water
1000
52.5
52500
m*a
514500
F/A
15
34300
34300
P*d/(2*f*J)

Thickness of Plate
Hydraulic Diameter of Plate
Internal Pressure on the Plate
Permissible tensile Stress on the Plate,770kg/cm^2 for CI Pipes,1260 kg/cm2 for steel
pipes,1400 kg/cm2 for MS Plates).

Joint efficiency 0.9 for Welded Pipes,0.75 for double revited,0.63 for Single revited.).
0.9375
3.75
1400
137200000
0.000520833333333
0.520833333333333
1
m
m
m

kg/m3
m3
kgs

kg-m/Sec^2

m2
kg-m/(Sec^2*m2)
kg/(m*Sec^2)
m

m
m
kg/cm^2
kg/(m*Sec^2)
m
mm
mm