DRAWING INDEX PROPOSED TOWNHOUSES & ALTERATION WORKS

4 HYTON CRES, KEW


S0 - DRAWING INDEX & GENERAL NOTES
S1 - BULK EXCAVATION AND SITE RETENTION PLAN
S2 - RETAINING WALL ELEVATIONS
S3 - RETAINING WALL SECTIONS
S4 - RETAINING WALL DETAILS
IMPORTANT NOTES
S5 - FOOTING PLAN GENERAL STRUCTURAL STEELWORK
MASONRY NOTES
S6 - BASEMENT FLOOR PLAN 1. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL 3. COVER (mm) TO ALL REINFORCEMENT, UNLESS OTHERWISE SHOWN, 1. ALL WORKMANSHIP AND MATERIALS SHALL COMPLY WITH AS4100, RELATED
ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND SHALL BE AS FOLLOWS: 1. ALL WORKMANSHIP & MATERIALS SHALL COMPLY
STANDARDS AND THE SPECIFICATION.
S7 - GROUND FLOOR PROFILE PLAN SPECIFICATIONS. DISCREPANCIES SHALL BE REFERRED TO THE WITH AS3700. MORTAR MIX SHALL BE 1:1:6
ENGINEER AND ARCHITECT FOR DECISION BEFORE PROCEEDING 2. COPIES OF ALL SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER
S8 - GROUND FLOOR REINFORCEMENT PLAN WITH THE WORK. ELEMENT
FORMED & NOT
EXPOSED TO
FORMED & EXPOSED
TO GROUND WATER
NOT FORMED
CAST AGAINST
FOR REVIEW PRIOR TO THE COMMENCEMENT OF FABRICATION. REVIEW
2. BRICKS SHALL HAVE A CHARACTERISTIC UNCONFINED
WEATHER OR WEATHER GROUND etc. COMPRESSIVE STRENGTH OF 40MPa IN ACCORDANCE
DOES NOT INCLUDE CHECKING OF DIMENSIONS. WITH AS4455 AND AS4456.
S9 - CONCRETE DETAILS - SHEET 1 2. ALL SET OUT DIMENSIONS AND LEVELS, INCLUDING ANY SHOWN ON FOOTINGS N.A. 50 65
STRUCTURAL DRAWINGS, SHALL BE IN ACCORDANCE WITH THE 3. THE CONTRACTOR SHALL PROVIDE AND LEAVE IN PLACE, UNTIL 3. VERTICAL ARTICULATION JOINTS ARE TO BE IN
S10 - CONCRETE DETAILS - SHEET 2 ARCHITECTS DRAWINGS AND VERIFIED BY THE CONTRACTOR RETAINING WALLS 40 40 65 PERMANENT STABILIZATION IS CONSTRUCTED, SUCH TEMPORARY BRACING ACCORDANCE WITH AS3700-2001 CLAUSE 12.6.4.2
BEFORE CONSTRUCTION OR FABRICATION COMMENCES. ANY ETC. AS IS NECESSARY TO STABILIZE THE STRUCTURE DURING ERECTION. 'ARTICULATION JOINTS'.
S11 - CONCRETE DETAILS - SHEET 3 DISCREPANCIES IN THE DOCUMENTS MUST BE RESOLVED BEFORE COLUMNS 40 40 N.A.
REFER GENERAL NOTES.
ORDERING OR PLACING ANY MATERIALS. THESE DRAWINGS ARE
WALLS 40 40 N.A.
S12 - CONCRETE DETAILS - SHEET 4 NOT TO BE SCALED. 4. THESE STRUCTURAL DRAWINGS PROVIDE DETAILS OF MAJOR STRUCTURAL
STEELWORK. MINOR ITEMS SUCH AS CLEATS, TRIMMERS ETC. FOR THE
SLABS 25 40 40
S13 - FORMWORK WALL CONNECTION DETAILS 3. DURING CONSTRUCTION, THE CONTRACTOR SHALL ENSURE THAT ATTACHMENT OF ARCHITECTURAL ELEMENTS IS THE RESPONSIBILITY OF TIMBER FRAMING NOTES
ALL PARTS OF THE STRUCTURE ARE MAINTAINED IN A STABLE BANDBEAMS 25 40 N.A. THE CONTRACTOR.
CONDITION AND THAT NO PART OF THE STRUCTURE IS ALL TIMBER FRAMING IS TO BE IN ACCORDANCE WITH AS1684,
S14 - LEVEL 1 FRAMING PLAN OVERSTRESSED AS A RESULT OF HIS CONSTRUCTION PROCEDURE 5. UNLESS OTHERWISE SHOWN: RESIDENTIAL TIMBER FRAMED CONSTRUCTION CODE AND AS1720,
BEAMS 40 40 N.A.
OR THE CONSTRUCTION LOADS WHICH ARE APPLIED. (a) ALL HOT ROLLED STEEL SECTIONS SHALL BE 300 PLUS BHP TIMBER STRUCTURES CODE.
S15 - ROOF FRAMING PLAN STRUCTURAL STEEL.
4. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE ALL REINFORCEMENT SHALL BE RIGIDLY SUPPORTED IN ITS CORRECT ALL TIMBER STRESS GRADES NOMINATED SHALL BE IN ACCORDANCE
S16 - FRAMING DETAILS WITH THE REQUIREMENTS OF THE SAA CODES, THE BUILDING CODE POSITION WITHIN THE SPECIFIED TOLERANCES DURING CONCRETING BY
(b) ALL TUBULAR SECTIONS SHALL BE C350 GRADE MINIMUM.
(c) ALL CLEATS SHALL BE 10mm THICK.
WITH THE RELEVANT CODES, AND MEANS THE STRUCTURAL QUALITY OF
OF AUSTRALIA, AND THE BY-LAWS AND ORDINANCES OF THE APPROVED BAR CHAIRS, SPACERS OR SUPPORT BARS. A TIMBER SECTION. REFER TO AS1720.
(d) ALL FILLET WELDS TO BE 6mm CONTINUOUS.
RELEVANT BUILDING AUTHORITY.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT THE (e) ALL WELDS SHALL BE CATEGORY SP. WELDS SHALL CONFORM TO TIMBER SHALL BE STORED AND HANDLED SO AS NOT TO BE
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT FORMWORK AND BACKPROPPING IS DESIGNED BY A QUALIFIED ENGINEER AS/NZS1554 AND ELECTRODES TO AS/NZS1553. DETRIMENTAL TO IT'S PERFORMANCE.
ALL TEMPORARY WORKS (I.E. FORMWORK, SCAFFOLDING, EXPERIENCED IN FORMWORK DESIGN, AND CONSTRUCTED IN (f) CONNECTIONS 2M20 8.8/S MINIMUM PER END OF MEMBER.
ACCORDANCE WITH AS3610. REFER TO ARCHITECTURAL DRAWINGS AND (g) ALL BOLTS SHALL BE 8.8/S GRADE. ALL TIMBER SHALL BE DRY, ie: LESS THAN 15% MOISTURE CONTENT AT
PROPPING, PLATFORMS, HOISTS, CRANEAGE, HOARDING, SIGNAGE THE TIME OF CONSTRUCTION AND SHALL BE PROTECTED AND/OR
ETC.) ARE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS FOR CLASSES OF SURFACE FINISH. (h) ALL DETAILS, GAUGE LINES, BOLT HOLE CLEARANCES ETC. SHALL TREATED AS NOTED.
THE REQUIREMENTS OF THE SAA CODES, THE BUILDING CODE OF BE IN ACCORDANCE WITH AISC STANDARDIZED STRUCTURAL
AUSTRALIA, AND THE BY-LAWS AND ORDINANCES OF THE 5. NO HOLES, REBATES etc. OTHER THAN THOSE SHOWN ON THE CONNECTIONS. ALL TIMBER BEAMS AND LINTELS ARE TO BEAR ON 2 No. 90x45 MGP10
RELEVANT BUILDING AUTHORITY. STRUCTURAL DRAWINGS SHALL BE MADE IN CONCRETE MEMBERS (i) BEAMS SHALL BE ERECTED WITH POSITIVE CAMBER. STUDS, U.N.O.
WITHOUT PRIOR APPROVAL OF THE ENGINEER.
6. THE CONTRACTOR SHALL ENSURE THAT THE LOCATIONS OF ALL 6. CORROSION PROTECTION OF STEELWORK SHALL BE IN ACCORDANCE WITH BEAMS/STUDS HAVING MORE THAN 1 MEMBER ARE TO BE NAIL
UNDERGROUND SERVICES ARE CONFIRMED PRIOR TO 6. CONSTRUCTION JOINTS SHALL BE PROPERLY FORMED AND USED ONLY THE SPECIFICATION. UNLESS NOTED OTHERWISE ON THESE DRAWINGS LAMINATED TOGETHER IN ACCORDANCE WITH AS1684.
COMMENCEMENT OF ANY EXCAVATIONS. WHERE SHOWN OR APPROVED BY THE ENGINEER. OR THE SPECIFICATION: ALL PROPRIETARY CONNECTORS AND FIXINGS TO BE INSTALLED IN
(a) INTERNAL STRUCTURAL STEELWORK SHALL RECEIVE A SINGLE SHOP ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
7. ALL CONTRACTORS SHALL COMPLY WITH ALL APPLICABLE 7. CURING SHALL BE CARRIED OUT ON ALL STRUCTURAL CONCRETE IN COAT OF INORGANIC ZINC SILICATE (75 MICRONS D.F.T.) ALL EXTERNAL TIMBER SHALL HAVE A SUITABLE DURABILITY FOR
OCCUPATIONAL HEALTH AND SAFETY ACTS, CODES OF PRACTICE, ACCORDANCE WITH THE SPECIFICATION UNLESS APPROVED OTHERWISE RELEVANT CLIMATE AND EXPECTED SERVICE LIFE, AND CONDITIONS.
(b) ALL EXTERNAL STEELWORK AND FASTENERS SHALL BE HOT DIPPED GUIDANCE ON DURABILITY IS GIVED IN AS1684, APPENDIX C.
GUIDANCE NOTES AND OTHER INFORMATION RELEVANT TO HEALTH BY THE ENGINEER.
GALVANIZED IN ACCORDANCE WITH AS4680.
AND SAFETY. (c) ALL STEELWORK BELOW GROUND SHALL BE ENCLOSED BY
8. ALL CONCRETE SUPPLIED ON THIS PROJECT WITH A CHARACTERISTIC
STRENGTH GREATER THAN 40 MPa SHALL BE SUBJECT TO PROJECT CONCRETE WITH 75mm MINIMUM COVER.
8. OUR "CONSTRUCTION ISSUE" SIGNIFIES DRAWINGS WHICH HAVE
RECEIVED BUILDING PERMIT APPROVAL EXCEPT FOR THOSE PARTS ASSESSMENT OF STRENGTH GRADE.
7. THE BOLTING PROCEDURE IS AS FOLLOWS:
WHICH ARE 'DESIGN & CONSTRUCT'. OTHER CONSULTANTS
THIS SHALL APPLY TO CONCRETE DELIVERED EITHER TO SITE OR THE (a) 4.6/S REFERS TO COMMERCIAL BOLTS OF STRENGTH GRADE 4.6
DRAWINGS SHALL BE FINALIZED FOR THOSE PARTS WHICH AFFECT
PRECAST MANUFACTURER. TO AS1111 TIGHTENED USING A STANDARD WRENCH TO A
STRUCTURE PRIOR TO US ISSUING CONSTRUCTION DRAWINGS. ANY
SNUG-TIGHT CONDITION.
MINOR CHANGES CAUSED BY OTHER CONSULTANTS, SITE
THE FREQUENCY OF SAMPLING AT THE POINT OF DELIVERY SHALL BE (b) 8.8/S REFERS TO HIGH STRENGTH BOLTS OF STRENGTH GRADE
CONDITIONS OR OURSELVES AFTER ISSUING CONSTRUCTION
AT LEAST ONE SAMPLE (3 CYLINDERS) FROM EACH 50 CUBIC METRES 8.8 TO AS1252 TIGHTENED USING A STANDARD WRENCH TO A
DRAWINGS SHALL BE ADDRESSED VIA SEPARATE SITE
OF CONCRETE USED IN THE PROJECT FOR EACH STRENGTH GRADE. SNUG-TIGHT CONDITION.
INSTRUCTIONS. ANY MAJOR CHANGES MAY BE RESUBMITTED FOR
BUILDING PERMIT. (c) 8.8/TF OR 8.8/TB REFERS TO HIGH STRENGTH BOLTS OF
THE SAMPLING AND COMPRESSIVE TESTS SHALL BE CARRIED OUT BY STRENGTH GRADE 8.8 TO AS1252 TENSIONED TO AS4100.
DESIGN LOAD DATA AN INDEPENDENT APPROVED N.A.T.A LABORATORY.
8. ALL BOLTS SHALL HAVE AT LEAST ONE FULL THREAD EXPOSED BEYOND
THE BUILDER SHALL COLLATE THESE TEST RESULTS AND ISSUE THEM THE NUT AFTER THE NUT HAS BEEN TIGHTENED.
THE FOLLOWING DESIGN LOADS HAVE BEEN ADOPTED FOR THIS PROJECT: TO HTD CONSULTANTS FOR THEIR VERIFICATION. PROVIDE MINIMUM OF ONE WASHER UNDER THE NUT AND BOLT HEAD IN
ALL SITUATIONS. FOR SLOTTED HOLES USE HARDENED WASHER UNDER
ADDITIONAL
FLOOR USE LIVE LOAD (kPa)
DEAD LOAD (kPa) WATER MAY ONLY BE ADDED TO CONCRETE IN THE TRUCK UNDER THE THE NUT AND BOLT HEAD.
STRICT GUIDELINES SPECIFIED BY THE CONCRETE SUPPLIER. UNDER NO
CARPARK 2.5 0.3 9. FOR TF AND TB BOLTS USE LOAD INDICATING WASHERS TO VERIFY
CIRCUMSTANCES CAN WATER BE ADDED AFTER TAKING TEST SAMPLES.
TIGHTENING AND A HARDENED WASHER UNDER THE ROTATED END.
APARTMENT 2 1.2
9. REINFORCEMENT SYMBOLS AND GRADES:
STARS LOBBIES, ETC.. 4 0.3 N- HOT ROLLED DEFORMED BARS (GRADE 500)
R- STRUCTURAL GRADE PLAIN ROUND BAR (GRADE 250)
BALCONIES 2 1.2 SL,RL - HARD DRAWN STEEL WIRE REINFORCING FABRIC (GRADE
500)
W- HARD DRAWN STEEL WIRE REINFORCING WIRE (GRADE 450)

BARS ARE DENOTED ON THE DRAWINGS IN THE FOLLOWING MANNER:


CONCRETE AND REINFORCEMENT eg... 10N20-200
DENOTES 10no. 500 N GRADE 20mm DIAMETER BARS AT 200mm
1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE CENTRES
WITH AS3600, RELATED STANDARDS, AND THE SPECIFICATION.
ALL REINFORCEMENT SHALL COMPLY WITH AS/NZS4671
2. UNLESS NOTED OTHERWISE BELOW OR ELSEWHERE ON THESE
DRAWINGS THE CHARACTERISTIC STRENGTH OF ALL CONCRETE 10. REINFORCEMENT IS REPRESENTED DIAGRAMATICALLY ONLY ON THESE
SHALL BE 32 MPa DRAWINGS

11. HOOKS, COGS AND SPLICES IN REINFORCEMENT SHALL COMPLY WITH


AS3600 UNLESS NOTED OTHERWISE.
ELEMENT F'c (MPa)
12. SPLICES IN REINFORCEMENT SHALL BE MADE ONLY IN THE POSITIONS
BLINDING CONCRETE 15 SHOWN OR AS OTHERWISE APPROVED BY THE ENGINEER.
FOOTINGS 40
13. PIPEWORK SHALL NOT BE CAST INTO CONCRETE UNLESS SHOWN
COLUMNS REFER SCHEDULE OTHERWISE ON THESE DRAWINGS OR APPROVED BY THE ENGINEER.

PRECAST WALLS REFER ELEVS. 14. ALL NON-LOADBEARING WALLS SHALL BE KEPT 20mm CLEAR OF THE
UNDERSIDE OF SLABS OR BEAMS. THE WALLS SHALL NOT BE
IN-SITU WALLS REFER ELEVS. CONSTRUCTED UNTIL REMOVAL OF ALL PROPS.

15. STRIPPING AND BACKPROPPING OF SLABS AND BEAMS SHALL NOT


OCCUR UNTIL FULL POST-TENSIONING HAS BEEN APPLIED AND THE
CONCRETE HAS REACHED 80% OF SPECIFIED STRENGTH. UNLESS
OTHERWISE CALCULATED, BACKPROPPING SHALL EXTEND DOWN SUCH
THAT EACH NEW FLOOR IS SUPPORTED BY AT LEAST TWO FINISHED
FLOORS.

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof GENERAL NOTES MR. D. LAND N/A
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni
& DRAWING INDEX nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S0 1
NOTES:

EXISTING SINGLE STORY 1. REFER NOTES ON DRG S1.


BRICK BUILDING
2. THE CONTRACTOR SHALL REFER TO THE GEOTECHNICAL REPORT BY J.R
ASSOCIATES PTY. LTD. (REPORT No. -)

1000 1000 3. SP1 - 450 DIA. AT 2250 MAX. CTS CAST-INSITU SOLDIER PILES.
BOUNDARY LINE SP2 - 450 DIA. AT 1500 MAX. CTS CAST-INSITU SOLDIER PILES.
1200 SP3 - 450 DIA. AT 1500 MAX. CTS CAST-INSITU SOLDIER PILES.

1
SP

SP

SP

SP

SP

SP
1000

1000
C REFER NOTES BELOW FOR DESIGN REQUIREMENTS TO CAST-INSITU

2
SP
1
SP

S2 SOLDIER PILES AND REFER TO DRG. S4 FOR OUR PROPOSED SOLDIER PILES
R.7 D DETAILS.

2
SP
S3 S2
1
SP

4. LEGENDS:

2
SP
1.83m WIDE R.1 190 REINFORCED BLOCKWORK RETAINING WALLS TO BE CONSTRUCTED LATER:
EASEMENT S3 REFER DRG. S2 FOR DETAILS.
LINE P2
S
1
SP

EQ EQ
A ELEVATION MARK
S2

3
REFRENCE DRAWING

3
SP

SP

SP

1000
B

3
E
1

EXISTING DOUBLE
SP

SP
BOUNDARY LINE

Y LINE
S2
S2
R.2 STORY, DOUBLE

3
SP

BOUNDAR
EXISTING SERVICES:
S3
F BRICK BUILDING
1
SP

3
SP
S2 BEFORE CARRYING OUT ANY OF THESE WORKS, IT IS THE
CONTRACTOR'S RESPONSIBILITY TO OBTAIN THE
LOCATION OF ANY EXISTING SERVICES FROM THE

3
SP
RELEVANT AUTHORITIES AND ENSURE THEY ARE NOT

1000
R.4 3 2 1 3 2 1 3 DAMAGED OR AFFECTED BY THE WORKS.
1
SP

S3 1 2
SP

3
1

SP
SP
1000
R.3 G
1

1.2M MAX. UNDERPINS


SP

HATCH DENOTES
S3 S2 SHALL BE CARRIED OUT RETAINING REINFORCED
RAMP UP BEFORE ANY EXCAVATION BLOCK WALL. REFER
WORKS (U.N.O) SECTIONS 5 & 6 ON DRG.
A S15 FOR DETAILS
1
SP

S2
1000

BOUNDARY LINE
2
2

1
SP
SP

SP

SP

SP

SP

SP

SP

SP

1000

LIGHTWEIGHT R.5
S3
EXISTING
SHED
SITE RETENTION AND BULK EXCAVATION PLAN

SITE RETENTION: CONSTRUCTION SEQUENCE: UNDERPINNING


1. THE CONTRACTOR SHALL AT ALL TIMES PROVIDE PROTECTION TO
TEMPORARY WORKS: EXISTING SERVICES: 1. CONSTRUCT ALL SOLDIER PILES.
THE BUILDING BEING UNDERPINNED TO ENSURE NO DAMAGE
2. CONSTRUCT CAPPING BEAM ALL ROUND. OCCURS DURING CONSTRUCTION OR AFTER COMPLETION OF THE
1. THE CONTRACTOR SHALL SATISFY HIMSELF THAT THE ADJOINING BUILDINGS 1. BEFORE CARRYING OUT ANY OF THESE WORKS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO UNDERPINNING.
AND AREAS OUTSIDE THE SITE BOUNDARY ARE ADEQUATELY PROTECTED AND OBTAIN THE LOCATION OF ANY EXISTING SERVICES FROM THE RELEVANT AUTHORITIES AND 3. BULK EXCAVATE DOWN 1.5 M MAXIMUM DEPTH. FOR THE SHOTCRETE WALL ADJACENT
PREVENTED FROM SUBSIDENCE AND SHALL PROVIDE ANY EXTRA MATERIAL OR ENSURE THEY ARE NOT DAMAGED OR AFFECTED BY THE WORKS. TO THE ADJOINING BUILDING, THE FIRST DEPTH OF SHOTCRETE WALL SHALL NOT 2. UNDERPINS SHALL BE EXCAVATED AND CONSTRUCTED IN THE
WORK REQUIRED TO ACHIEVE THIS. EXTEND BELOW EXISTING ADJOINING FOOTING. NUMBERED SEQUENCE SHOWN.

2. THE CONTRACTOR IS TO PROVIDE ANY PROPPING, SHORING ETC. NECESSARY TO


DESIGN AND CONSTRUCT: 3. THE FOOTING TO BE UNDERPINNED SHALL BE EXPOSED ONLY FOR
4. PROVIDE TEMPORARY SHORING TO ANY PORTIONS OF THE EXPOSED FACE WHICH MAY
SAFELY SUPPORT THE SIDES AND FACES OF ANY EXCAVATION SO AS TO NOT BE SELF-SUPPORTING DURING OPEN PERIOD. THE WIDTH OF THE UNDERPIN.
PREVENT MOVEMENT. 1. THE CONTRACTOR MAY SUBMIT AN ALTERNATIVE DESIGN FOR THE SOLDIER PILES AND
GROUND ANCHORS. 5. CONSTRUCT SHOTCRETE WALL TO ALL EXPOSED FACES, ALLOWING FOR LAPPING OF 4. SECTIONS SHALL BE POURED UP TO WITHIN 75mm OF THE
3. ANY VOIDS, LOCAL COLLAPSES ETC. OVER THE STREET ALIGNMENT ARE TO BE REINFORCEMENT. UNDERSIDE OF THE EXISTING FOOTING AND LEFT 24 HOURS (min.)
BACKFILLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE LOCAL 2. DESIGN SHALL COMPLY WITH THE REQUIREMENTS OF THE CURRENT CODES AS1170, AS2159 & BEFORE GROUTING COMMENCES. A FURTHER 24 HOURS (min.)
AUTHORITIES. AS2600. 6. REPEAT STEPS 3 TO 5 UNTIL THE FINAL EXCAVATION LEVEL IS REACHED. SHALL PASS BEFORE NEXT UNDERPINS ARE EXCAVATED.

4. THE BUILDER SHALL STRICTLY FOLLOW THE PROCEDURES ON THE DRAWINGS 3. PILES AND GROUND ANCHORS SHALL BE DESIGNED TO CARRY AT LEAST THE FOLLOWING 5. CAULKING SHALL CONSIST OF A HARD RAMMED NON-SHRINK
AND ANY VARIATIONS TO THE SHORING PROCEDURES SHALL BE TO THE LOADS: CAST IN-SITU SOLDIER PILES: GROUT SUITABLE FOR THIS PURPOSE UNIFORMLY SUPPORTING THE
ENGINEERS APPROVAL. WHOLE OF THE EXISTING FOOTING.
PILES AND GROUND ANCHORS: 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER SET-OUT OF THE PILES IN
5. ANY INTRUSIONS OVER THE STREET ALIGNMENT FOR A DEPTH OF 1500 mm ACCORDANCE WITH ENGINEERS AND ARCHITECTS DRAWINGS. 6. CONCRETE IN EACH UNDERPINNING SECTION IS TO BE PLACED
SHALL BE REMOVED ON COMPLETION OF TEMPORARY WORKS. a. EARTH PRESSURE & HYDROSTATIC PRESSURE (REFER GEOTECH. REPORT) AGAINST NATURAL GROUND EXCEPT FOR THE EXTERNAL FACE
b. ROADWAY SURCHARGE (REFER TO SECTION FOR DETAILS) 2. WORKS SHALL COMPLY WITH THE REQUIREMENTS OF THE CURRENT CODES AS2159 AND WHICH IS TO BE FORMED VERTICALLY.
6. ANY WATER IN THE EXCAVATION IS TO BE DRAINED TO A PIT WITH A SILT c. ADJOINING BUILDING SURCHARGE (REFER TO SECTION FOR DETAILS) AS2600.
TRAP. 7. FACES OF CONCRETE IN ADJACENT UNDERPINS SHALL BE
PILES: SHOTCRETE WALL: THOROUGHLY CLEANED BEFORE PLACING THE NEW SECTION.
7. ANY DISCHARGE INTO COUNCIL DRAINS MUST COMPLY WITH THE REQUIREMENTS PERMANENT VERTICAL LOADS IN ADDITION TO ABOVE (REFER ENGINEER)
OF THE COUNCIL AND THE E.P.A. 8. ANY VARIATION IN FOOTINGS OF ADJACENT BUILDINGS TO THOSE
1. ALL SHOTCRETE WORKS SHALL BE CARRIED OUT BY AN APPROVED, EXPERIENCED
4. THE CONTRACTORS DESIGN CALCULATIONS SHALL BE SUBMITTED FOR REVIEW TO THE SHOWN ON THE DRAWING IS TO BE IMMEDIATELY BROUGHT TO THE
OPERATOR.
DILAPIDATION SURVEY: ENGINEER. CERTIFICATION OF THE CONTRACTORS DESIGN SHALL BE THE RESPONSIBILITY OF ATTENTION OF THE ENGINEER.
THE BUILDING SURVEYOR'S CHECKING ENGINEER OR SELF-CERTIFICATION IF PERMITTED BY 2. ALL SHOTCRETE WORKS AND QUALITY CONTROL SHALL CONFORM TO RECOMMENDED
THE BUILDING SURVEYOR. 9. THE CONTRACTOR SHALL PROVIDE ANY PROPPING, SHORING etc.,
1. IT IS RECOMMENDED THAT THE BUILDER (OR CLIENT) ARRANGE FOR A PRACTICE BY THE CONCRETE INSTITUTE OF AUSTRALIA.
DEEMED BY HIM OR THE ARCHITECT TO BE NECESSARY TO SAFELY
THOROUGH DILAPIDATION SURVEY OF NEIGHBOURING BUILDINGS THAT MAY BE SUPPORT THE SIDES OF ANY EXCAVATION AND EXISTING WALLS
AFFECTED BY THE WORKS. SO AS TO PREVENT MOVEMENT AND ENSURE SAFETY OF
PERSONNEL.

10. IN WET CONDITIONS IT MAY BE NECESSARY TO PROVIDE 50mm


BLINDING CONCRETE IN THE BOTTOM OF UNDERPIN EXCAVATIONS.

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof SITE RETENTION AND BULK MR. D. LAND 1:100 U.N.O
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni
EXCAVATION PLAN nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S1 1
BOUNDARY LINE

BOUNDARY LINE

BOUNDARY LINE
R.6 R.5 R.3 R.4
S3 S3 S3 S3

N.G.L EXISTING SHED BEHIND


GROUND GROUND

N.G.L 150 THICK SHOTCRETE


WALL. 40 MPa.
150 THICK SHOTCRETE RL1018 M.W.H.
WALL. 40 MPa.
BASEMENT RL1018 M.W.H. BASEMENT

EMBEDMENT

EMBEDMENT
3.5M MIN.

3.5M MIN.
HATCH DENOTES 180 THICK INSITU DOWNTURN WALL.
N16-300 E.W CENTRAL 2
SP

1
2

SP

SP

SP

SP

SP

SP

SP

SP
1

1
SP

SP

SP

SP

SP

SP

SP

SP
HATCH DENOTES MAX. 1.2M HEIGHT 190 THICK
REINFORCED BLOCKWALL . REFER DRG. S12 FOR
REINFORCEMENT

ELEVATION A ELEVATION B
(SOUTH ELEVATION) (WEST ELEVATION)
HATCH DENOTES 180 THICK INSITU DOWNTURN WALL.
N16-300 E.W CENTRAL
BOUNDARY LINE

BOUNDARY LINE

BOUNDARY LINE
R.7 R.1
EXISTING
S3 S3
APARTMENT
BUILDING

EXISTING APARTMENT BEHIND


GROUND GROUND N.G.L GROUND
N.G.L N.G.L

150 THICK SHOTCRETE 150 THICK SHOTCRETE 150 THICK SHOTCRETE


WALL. 40 MPa. WALL. 40 MPa. WALL. 40 MPa.
RL1018 M.W.H. RL1018 M.W.H. RAMP SLAB RL1018 M.W.H.

BASEMENT BASEMENT BASEMENT


EMBEDMENT

EMBEDMENT

EMBEDMENT
3.5M MIN.

3.5M MIN.

3.5M MIN.

3
3

3
2

2
2
1

1
SP

SP

SP

SP
SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP
NOTES:

ELEVATION C ELEVATION D ELEVATION E 1. REFER NOTES ON DRG S0.

(NORTH ELEVATION) (EAST ELEVATION) 2. REFER SITE RETENTION PLAN ON


DRG S1.
HATCH DENOTES 190 THICK REINFORCED BLOCKWALL.
REFER DRG. S12 FOR REINFORCEMENT
3. REFER ARCHITECTS DRAWING
FOR ALL SLAB RL'S.
BOUNDARY LINE

BOUNDARY LINE

BOUNDARY LINE

BOUNDARY LINE
R.2 R.5
S3 S3

EXISTING APARTMENT BEHIND

EXISTING APARTMENT BEHIND N.G.L


GROUND N.G.L GROUND

150 THICK SHOTCRETE 150 THICK SHOTCRETE N.G.L


WALL. 40 MPa. RAMP SLAB WALL. 40 MPa. LINE OF SOFFIT OF
RL1018 M.W.H. RL1018 M.W.H. EXISTING FOOTING.
1 3 BUILDER TO VERIFY
3 2
BASEMENT BASEMENT ON SITE
3 2 1
EMBEDMENT

EMBEDMENT
3.5M MIN.

3.5M MIN.

DENOTES UNDERPINNING
SEQUENCE. REFER PLAN
3
3

1
SP
SP

SP

SP

SP

SP

SP

SP
FOR DETAILS

ELEVATION F ELEVATION G
(EAST ELEVATION) (NORTH ELEVATION)
HATCH DENOTES 190 THICK REINFORCED BLOCKWALL.
REFER DRG. S12 FOR REINFORCEMENT

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof RETAINING WALL ELEVATIONS MR. D. LAND 1:100 U.N.O
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S2 1
EXISTING EXISTING TILE ROOF
TILE ROOF
EXISTING TILE ROOF

EXISTING
LIGHTWEIGHT EXISTING
EXISTING FLOOR LIGHTWEIGHT
LIGHTWEIGHT FLOOR
FLOOR

EXISTING EXISTING
DOUBLE BRICK DOUBLE BRICK
EXISTING BUILDING BUILDING
DOUBLE BRICK
BUILDING

EXISTING
EXISTING
CONCRETE
EXISTING CONCRETE EXISTING
FLOOR
CONCRETE FLOOR SINGLE STORY
BUILDER TO BRICK BUILDING
FLOOR 1450
VERIFY ON SITE

TITLE BOUNDARY

TITLE BOUNDARY

TITLE BOUNDARY
1500
EXISTING
LIGHTWEIGHT GROUND LEVEL GROUND LEVEL

TITLE BOUNDARY
NSL
GROUND LEVEL GROUND LEVEL SHED

LOADS AT SOFFIT OF
LOADS AT SOFFIT OF EXISTING FOOTING
EXISTING FOOTING LOADS AT SOFFIT OF
EXISTING FOOTING F = 50 kN/m
F = 50 kN/m
F = 50 kN/m

LOADS AT SOFFIT OF
EXISTING FOOTING
BASEMENT LEVEL BASEMENT LEVEL BASEMENT LEVEL F = 10 kN/m BASEMENT LEVEL BASEMENT LEVEL
UNDERPIN. REFER
DRG. S1 FOR DETAILS

SECTION R.1 SECTION R.2 SECTION R.3 SECTION R.4 SECTION R.5 SECTION R.7
S1 S1 S1 S1 S1 S1

NOTES:

1. REFER NOTES ON DRG S0.

2. REFER SITE RETENTION PLAN ON DRG S1.

3. REFER ARCHITECTS DRAWING FOR ALL SLAB RL'S.

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof RETAINING WALL SECTIONS MR. D. LAND 1:50 (U.N.O)
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S3 1
1
SP
N12-300 x 600 LG
STARTER BARS.
CL 50 MIN.
SOLDIER PILE

4N28 (BARS AT CORNER)

300
500 MIN. 800 MIN. 500 MIN. N12-200 LIGS SCABBLED C.J.
REFER ADJACENT 30 CONCRETE COVER
2N20 SIDE 4N28 SIDE FOR REINFORCEMENT
REINFORCEMENT 35 REBATE FOR REINFORCEMENT 35 REBATE FOR 35 REBATE FOR
DETAILS
(900 LAPS) BAND BEAMS (900 LAPS). BAND BEAMS BAND BEAMS REFER WALL ELEVATION
GROUND SLAB GROUND SLAB GROUND SLAB
FOR REINFORCEMENT.
550 MIN.

550 MIN.
STRIP DRAIN - NOTE: DRAIN IS
NOT TO BE CAST INTO
SHOTCRETE WALL. (TO OCCUR TYPICAL HORIZONTAL
MIDSPAN BETWEEN SOLDIER WEEPHOLES
BAND BEAM
(WHERE APPLICABLE)
BAND BEAM
(WHERE APPLICABLE)
BAND BEAM
(WHERE APPLICABLE)
SOLDIER PILE LOCATIONS). CONSTRUCTION JOINT FOR
N16-300 BOTTOM N16-300 BOTTOM
N16-300 BOTTOM
STARTER BARS AT BAND
SHOTCRETE WALL
30 COVER
4N20 T&B 900 LAPS. STARTER BARS AT BAND 4N20 T&B 900 LAPS. STARTER BARS AT BAND
N12-300 x 800 LONG BEAM LOCATIONS.

200
N16-300 LIGS. BEAM LOCATIONS. N16-300 LIGS. BEAM LOCATIONS. 1200
200

200
U.N.O. ON RELEVANT 1200 U.N.O. ON RELEVANT 1200

SECTIONS. SECTIONS.
SHOTCRETE WALL.

3
SP
2/
SP
CL SAWCUT JOINT
SHOTCRETE WALL SHOTCRETE WALL
(BEHIND) (BEHIND) SOLDIER PILE (TYPICALLY EVERY
A A ALTERNATE PILE)
A A A A 4N32 (BARS AT CORNER)
HYDROPHYLIC WATERSTOP
N12-200 LIGS
ON CLEAN, SCABBLED
30 CONCRETE COVER
WEEP HOLE SURFACE ALL ROUND
1N12-200 CORNER BARS
HYDROPHYLIC WATERSTOP HYDROPHYLIC WATERSTOP N16-300 STARTER BARS 600
ON CLEAN, SCABBLED ON CLEAN, SCABBLED DRILLED AND EPOXY GROUTED

600
SURFACE ALL ROUND SURFACE ALL ROUND 300 MIN. INTO SOLDIER PILES.
STRIP DRAIN PINNED 45
0
BASEMENT SLAB BASEMENT SLAB TO EARTH BEHIND BASEMENT SLAB

300
SHOTCRETE WALL
SHOTCRETE WALL

A.G DRAIN IN SLAB SUB BASE.


REFER HYDRAULIC ENGINEERS
DRAWINGS. TYP.
TYPICAL SOLDIER PILE WITH TYPICAL SECTION AT
SHOTCRETE WALL DETAIL CORNER OF SHOTCRETE WALL
SECTION A-A
TYPICAL SECTION THROUGH
TYPICAL SOLDIER PILE SP1 TO TYPICAL SOLDIER PILE SP2/SP3 SHOTCRETE WALL & BASEMENT SLAB
CAPPING BEAM DETAIL TO CAPPING BEAM DETAIL

REFER TYPICAL CAPPING


600 TYP. COG BEAM FOR DETAILS
ALTERNATE BARS
4N24 E.F.
600

REFER TO CAPPING BEAM 600


DETAIL FOR REINFORCEMENT
SIZE AND NUMBER

500

REFER TYPICAL CAPPING


BEAM FOR DETAILS

TYPICAL SECTION AT TYPICAL CAPPING BEAM


CORNER OF CAPPING BEAM STEP DETAIL

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof RETAINING WALL DETAILS MR. D. LAND 1:20 U.N.O
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S4 1
NOTES:
1. REFER NOTES ON DRG. S0.
EXISTING SINGLE STORY
2. THE CONTRACTOR SHALL REFER TO THE GEOTECHNICAL REPORT
BRICK BUILDING BY SOUTHERN GEOTECHNICAL PTY. LTD (REPORT No. 16E085,
DATED 8 JUNE 2016)

3. ALL PAD FOOTINGS AND STRIP FOOTINGS SHALL BE FOUNDED ON


MEDIUM DENSE SAND WITH A MINIMUM BEARING CAPACITY OF 300
BOUNDARY LINE kPa (STRIP FOOTING) AND 300 kPa (PAD FOOTING). MASS
CONCRETE BLINDING SHALL BE PROVIDED TO EXTEND DOWN TO
THE FOUNDING LEVEL WHERE REQUIRED.

4. FOR MAXIMUM BATTER SLOPE REFER GEOTECHNICAL REPORT

7 5. REFER TO ARCHITECTURAL DRAWINGS FOR STRUCTURE SETOUT


S12 DIMENSIONS AND FINISHED FLOOR LEVELS.

1
PF
1 6. REFER BUILDING SERVICES DRAWINGS FOR CO-ORDINATION OF
S11 ALL UNDERGROUND SERVICES.

7. UNLESS NOTED OTHERWISE THE CENTRELINES OF COLUMNS AND


WALLS SHALL COINCIDE WITH THE CENTRELINES OF THE
FOOTINGS OR THE PAD FOOTINGS.

EXISTING DOUBLE
BOUNDARY LINE

Y LINE
1
PF
2 STORY, DOUBLE

BOUNDAR
S11
BRICK BUILDING PAD & STRIP FOOTING SCHEDULE

SF1

SF1
MARK SIZES DEPTH REINFORCEMENT
(mm) (mm)
4 3 2 1 3 2 1 3 PF1 1800 x 1800 700 N16-300 BTM E.W
S11 2

SF1 600 700 4N16 TOP & BTM. N12-300 LIGS

3 HATCH DENOTES
DENOTES UNDERPINS.
S11 RETAINING REINFORCED
REFER DRG. S1 FOR
RAMP UP BLOCK WALL. REFER
DETAILS
SECTIONS 5 & 6 ON DRG.
S12 FOR DETAILS

BOUNDARY LINE

LIGHTWEIGHT 5
S12
6
S12
EXISTING
SHED
FOOTING PLAN

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof FOOTING PLAN MR. D. LAND 1:100 U.N.O
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S5 1
SLAB ON GROUND NOTES:
1. REFER NOTES ON DRG. S0.
EXISTING SINGLE STORY 2. 120mm MIN. SLAB ON GROUND U.N.O.
BRICK BUILDING SL92 TOP THROUGHOUT.
C.J.
3. SLAB CONTROL JOINTS DEPICTED ON PLAN
SHALL BE EITHER CONSTRUCTION OR SAWCUT
JOINTS IN ACCORDANCE WITH DETAILS BELOW.

BOUNDARY LINE 4. BASEMENT SLAB SUB-BASE: 0.2 mm THICK POLYTHENE


MEMBRANE MOISTURE BARRIER ON 6mm SCREENINGS
LAID OVER 20mm SCREENINGS (75mm MIN. THICKNESS).

5. REFER GEOTECHNICAL REPORT FOR


SUBGRADE PREPARATION REQUIREMENTS

HATCH DENOTES 150 THICK 6. REFER TO ARCHITECTURAL DRAWINGS FOR:


FORMWORK WALL OVER. - DIMENSIONS AND FINISHED FLOOR LEVELS
40 MPa COCNRETE. N12-300
C.J CENTRAL E.W.
- LOCATION AND PROFILE OF UPSTANDS
REFER DRG. S13 FOR WALL - PITS ETC.
CONNECTION DETAILS (TYP.)

C1

C.J.
C.J

C.J
EXISTING DOUBLE 2N16 BARS TOP
BOUNDARY LINE

Y LINE
C.J x 1500 LONG.
STORY, DOUBLE
C1

BOUNDAR
C.J.

REFER DRG. S9
BRICK BUILDING
FOR COLUMN
DETAILS (TYP.)
UNJOINTED RE-ENTRANT CORNER

C.J.
2N16 BARS TOP
C.J x 1500 LONG.

TRENCH GRATE.
PROPOSED PIT/COLUMN.
REFER ADJACENT
DETAIL FOR RAMP UP
REINFORCEMENT C.J.

DRAINAGE PIT OR COLUMN WITHIN PAVEMENT


BOUNDARY LINE

C.J.
LIGHTWEIGHT
EXISTING C.J.

SHED 2N16 BARS TOP

BASEMENT FLOOR PLAN

C.J.
x 1500 LONG.

DISCONTINUOUS JOINTS

TYPICAL CORNER BAR DETAILS


SCALE = N/A
NOTE: ALL CORNER BARS NOT NECESSARILY SHOWN ON PLAN.

CUT-OUT 150mm LENGTH OF


TRANSVERSE WIRES LEAVING
STOP REINFORCEMENT WIRES AT 600 CTS.
25mm CLEAR OF JOINT.
DRAPE SLAB 30mm DEEP SAW CUT MADE WITHIN
200 MIN.

REINFORCEMENT 24 HOURS OF POURING SLAB


20 EQ UNLESS AGREED OTHERWISE WITH
TO 50mm REFER OTHERS FOR TRENCH
EQ BOTTOM THE ENGINEER. DIMENSIONS & GRATING
EQ COVER. DETAILS.
OR SAWCUT
300
300

150
BASEMENT SLAB SUB-BASE:
0.2mm THICK POLYTHENE MEMBRANE BASEMENT SLAB SUB-BASE:
4H:1V SLOPE TO 250 250 ON 6mm SCREENINGS LAID OVER 20mm 0.2mm THICK POLYTHENE MEMBRANE
SHOULDER OF KEY. SCREENINGS (75mm MIN. DEPTH). ON 6mm SCREENINGS LAID OVER 20mm

150
SCREENINGS (75mm MIN. DEPTH). N12-200 EACH WAY
3H:1V CENTRAL.
CONSTRUCTION JOINT SLOPE TO SAWCUT JOINT
BASE.

TYPICAL GRATED
CONTROL JOINT TRENCH DETAIL
SCALE = N/A SCALE = N.T.S

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof BASEMENT FLOOR PLAN MR. D. LAND 1:100 U.N.O
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S6 1
FLOOR SLAB NOTES:
1. REFER NOTES ON DRG. S0.
EXISTING SINGLE STORY
2. SLAB THICKNESSES SHALL BE 200mm UNLESS
BRICK BUILDING DEPICTED THUS: XXX

3. REFER TO ARCHITECTURAL DRAWINGS FOR:


- DIMENSIONS AND FINISHED FLOOR
LEVELS
400
BOUNDARY LINE - CHAMFERS TO CONCRETE EDGES
- LOCATION AND PROFILE OF UPSTANDS
ETC.

2
SC
STEEL COLUMN. REFER 4. ALL SERVICES PENETRATIONS THROUGH FLOOR
DRG. S16 FOR BASE

2
SLAB SHALL BE SLEEVED, NOT CORED.

2
SC

SC
3000 CONNECTION DETAILS
W1 (TYP.)
7
S12 600 5. LEGEND:
150
190 REINFORCED BLOCKWALL WALLS UNDER ONLY ARE

2
SC
STUD WALL
SHOWN THUS:
OVER (TYP.) 1 190 REINFORCED BLOCKWALL WALLS UNDER & OVER
S11 SHOWN THUS:
HATCH DENOTES 150 THICK
9
FORMWORK WALL OVER.
W2 S15 INSITU COLUMNS UNDER ONLY ARE SHOWN THUS:
40 MPa COCNRETE. N12-300 INSITU COLUMNS UNDER & OVER SHOWN THUS:
CENTRAL E.W. WALLS AND COLUMNS OVER ONLY SHOWN THUS:
REFER DRG. S13 FOR WALL DN

150
CONNECTION DETAILS 50 MAX. BATHROOM SETDOWN
(TYP.)
W3 EXISTING DOUBLE
BOUNDARY LINE

LINE
'BONDEK' SPANNING DIRECTION SHOWN THUS:

2 STORY, DOUBLE

Y
BOUNDAR
S11
BRICK BUILDING

W6
8
500

S15
350 150
TRANSFER LOAD SCHEDULE
4
MARK WORKING DEAD WORKING LIVE
S11 150 350 600
LOAD (G) LOAD (Q)
2

2
SC

SC

W5 W5 W5 W1 25 kN/m 10 kN/m
150

3
S11
RAMP DN W2 5 kN/m 5 kN/m
450
W3 35 kN/m 10 kN/m

BOUNDARY LINE

W5 25 kN/m 10 kN/m
SHADED AREA DENOTES
AREA IS NOT ALLOWED
LIGHTWEIGHT FOR BONDEK 5
S12
6
S12
HATCH DENOTES 190 THICK
REINFORCED CONCRETE
W6 5 kN/m 5 kN/m

EXISTING RETAINING BLOCK WALL. REFER


SITE RETENTION DRG. S12 FOR SC2 30 kN 20 kN
SHED DETAILS

GROUND FLOOR PROFILE PLAN

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof GROUND FLOOR PROFILE PLAN MR. D. LAND 1:100 U.N.O
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S7 1
FLOOR SLAB NOTES:
1. REFER NOTES ON DRG. S0.

2. FOR ANY SLAB AREAS WHERE SHOWN ON PLAN,


ADOPT 1.0mm BASE METAL THICKNESS 'BONDEK'.
DEVELOP MINIMUM 50mm BEARING INTO END
SUPPORTS AND MINIMUM 100mm BEARING AT
INTERMEDIATE SUPPORTS. BONDECK IS NOT ALLOWED
IN BAND BEAMS U.N.O.

3. WHERE REINFORCEMENT BARS ARE CALLED UP IN


ONE DIRECTION ON PLAN, DISTRIBUTION BARS ARE
REQUIRED IN THE TRANSVERSE DIRECTION. ALL
N16-300 N16-300 (3,000 + COG) +
DISTRIBUTION BARS SHALL BE N12-300 (300 LAPS) OR
(3,000 + COG) SL81 ADDITIONAL. REFER SL102 MESH (400 LAPS) UNLESS SHOWN OTHERWISE
BOUNDARY LINE SECTION 7 FOR DETAILS BOUNDARY LINE
ON PLAN OR SECTIONS.

4. REINFORCEMENT SHOWN ON PLAN ARE


DIAGRAMMATIC AND INDICATE THE SIZE AND NUMBER
ONLY. THEY MAY REPRESENT MORE THAN ONE
2N16-500 8N24
LIGS (5,000 +
LENGTH OR PROFILE.
SL92 + N16-400 COG)
(6,000) 5. MESH REINFORCEMENT SCHEDULE U.N.O.:
N16-300
- LENGTH: 6000mm. (U.N.O)
8N24 (8,000+COG) - BOTTOM: BUT UP AT CENTRE OF SUPPORT OR
(+ COG)
DEVELOP 200mm INTO SUPPORT. 60 COVER
- TOP: 400 LAP AT MINIMUM 2.5m FROM CENTRE
N16-300
2N16-300 (6,000 + COG)
OF SUPPORT OR AT MIDSPAN.
LIGS
6. REFER TO CONCRETE DETAIL DRAWINGS FOR
MINIMUM REINFORCEMENT TO BAND BEAMS AND
EXISTING DOUBLE EXISTING DOUBLE PENETRATION IN FLOOR SLAB ETC.
BOUNDARY LINE

BOUNDARY LINE
STORY, DOUBLE N16-300
STORY, DOUBLE 7. MAXIMUM TOTAL DEFLECTION FOR SLABS OR BEAMS
N16-300 SHALL BE THE LESSER OF Lef/300 OR 20mm.
SL92 +
N16-400
BRICK BUILDING (11,000+COG) (4,000 + BRICK BUILDING
COG)
(6,000) N16-300 N16-300 8. THE CONTRACTOR SHALL ALLOW FOR ADDITIONAL
EACH WAY EACH WAY REINFORCEMENT REQUIRED FOR ANY CONSTRUCTION
8N28
(10,000 + 3N20 JOINTS, TEMPORARY PENETRATIONS REQUIRED IN
2N16-500 COG) (5,000+COG) SLABS DURING CONSTRUCTION, ETC.
LIGS

9. LEGEND:

8N20 N16-300 (1000 + COG)


3N20-200 N16-300 3N20
(2,000+COG) (5,000+COG)
(7,000) (3,000) STANDARD COG AT END.
8N24 TOTAL LENGTH OF BAR IN MM.
(9,000 +
COG) BAR SPACING.

SIZE OR BAR.
BOUNDARY LINE BOUNDARY LINE
N16-300
(8,000+COG)
SHADED AREA DENOTES SHADED AREA DENOTES
AREA IS NOT ALLOWED AREA IS NOT ALLOWED
FOR BONDEK FOR BONDEK

GROUND FLOOR BOTTOM REINFORCEMENT PLAN GROUND FLOOR TOP REINFORCEMENT PLAN

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof GROUND FLOOR REINFORCEMENT MR. D. LAND 1:100 U.N.O
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni PLAN nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S8 1
N12-300 T
DISTRIBUTION BARS
TO PROTRUDE 500 INTO 500 500
40
0 ADJACENT FLOOR SLAB
(WHERE POSSIBLE) N12-300 T
N12-300
DISTRIBUTION BARS 400
TOP OF FLIGHT 40
0
N12-150 T&B BASE LEVEL

300 MIN.
N16-150 B SUPPORT WALL SUPPORT WALL
40 UNDER UNDER
0
180 THICK U.N.O.
ON FLOOR PLANS
C.J. SCABBLE

TYPICAL STAIR BASE DETAIL TYPICAL LANDING AT FLOOR LEVEL CROSS SECTION

AT
N12-300

RO
DISTRIBUTION BARS

TH
180
L
N12-300 T
DISTRIBUTION BARS
1.5 T L TO PROTRUDE 500 INTO
40 ADJACENT FLOOR SLAB
0
1.5 T (WHERE POSSIBLE)
N12-300
DISTRIBUTION BARS N12-300 T
S

S
N16-150 B BOTTOM OF FLIGHT
TYPICAL STAIR DETAIL 40
0
NOTE: 17 No. MAXIMUM RISERS PER FLIGHT
L CL
C.J. SCABBLED
1:6 MAX. CRANK (TYP.) COLUMN AND (OPTIONAL) N16-150 B
L PAD FOOTING U.N.O.
180 THICK U.N.O.
STANDARD COG. COG BARS IF SLAB/BEAM DEPTH ON FLOOR PLANS
IS LESS THAN 20 BAR DIA. +
S = LESS THAN 0.2 T S = LESS THAN 0.8 T 100.
GROUND SLAB

L L

100
S

L L 1.5 T
STARTER BARS SAME NUMBER,
TYPE, SIZE AND ARRANGEMENT
1.5 T AS FOR COLUMN BARS UNLESS
NOTED OTHERWISE IN COLUMN
SCHEDULE.
TOP REINFORCEMENT BOTTOM REINFORCEMENT

40 BAR DIA.
S = GREATER THAN 0.8 T AND LESS THAN 1.5 T

BOUNDARY LINE
C.J. CLEAN, ROUGHENED
SURFACE (TYP.)
L L
BASEMENT SLAB

190 THICK
S

'L' 300

FOOTING DEPTH
N16-200 EACH WAY
(CENTRAL WITHIN CORE)
N16-250 E.F. N16-250 E.F. 600 LAPS WHERE REQUIRED

300
4N24
L L 1.5 T N12-300 TIES FULL BEDDING, FLUSH
FILL ALL CORES WITH MORTAR JOINTING IN

1200 MAX.
20 MPa CONCRETE ACCORDANCE WITH
1.5 T
APPROVED (12mm MAX. AGGREGATE MASONRY CODE, AS3700.
FOUNDING CONCRETE GRADE SIZE, 230 SLUMP)
TOP REINFORCEMENT BOTTOM REINFORCEMENT LEVEL. F'c = 50 MPa RAMP SLAB
2 SETS OF R10 TIES FOR N.G.L (VARIES)
COLUMN C1

600
S = GREATER THAN 1.5 T SUPPORT OF STARTER BARS. STANDARD COG IF 'L' IS
LESS THAN 35 BAR DIA. SCALE = 1:20 A.G DRAIN BY
50mm BLINDING CONCRETE OTHERS
'L' NOTES: (GRADE 15MPa). EXTEND AND COG
BAR SIZE DEVELOPMENT LENGTH (mm) CORNER BARS ONLY. 200 MIN.
1 DETAILS APPLY UNLESS SHOWN OTHERWISE ON DRAWINGS.
NOTES:

500
2
SF
N12 400 2 'T' REFERS TO SLAB THICKNESS. N16-200
1. FOR REINFORCEMENT, DIMENSIONS ETC, REFER COLUMN SCHEDULE AND PAD STARTER 300
FOOTING SCHEDULE. BARS
3 SETDOWNS GREATER THAN 1.5T TO ENGINEERS DETAIL.
N16 600
4 MINIMUM INTERNAL DIAMETER OF ALL BAR BENDS 2. OVEREXCAVATION BELOW FOOTINGS TO BE FILLED TO UNDERSIDE OF FOOTING WITH
SHALL BE 10 BAR DIA. GRADE 15 MPa CONCRETE. 800
N20 800
5 SETDOWNS AND STEPS ARE DENOTED ON PLANS AS:XX 3. OVEREXCAVATION AROUND FOOTINGS TO BE FILLED WITH SAME GRADE CONCRETE SL81 T&B
50mm BLINDING CONCRETE
N24 1000 AS FOOTINGS OR CEMENT STABILIZED SAND. (7% CEMENT BY VOLUME) (f'c = 150 mPa )
4. DETAILS ABOVE APPLY UNLESS SHOWN OTHERWISE ON DRAWINGS.

SUSPENDED FLOOR SETDOWNS TYPICAL PAD FOOTING-CONCRETE COLUMN DETAIL TYPICAL RETAINING BLOCK WALL DETAIL
SCALE = N/A
(FOR NORMAL REINFORCEMENT)
N.T.S.

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof CONCRETE DETAILS - SHEET 1 MR. D. LAND 1:20 (U.N.O)
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S9 1
TOP SLAB COLUMN
BARS OR OR WALL.
FABRIC.
0.30 Ln1 0.30 Ln 0.30 Ln
500 500
STANDARD N16-500 U.N.O. SEE NOTE 7.
COG 0.20 Ln1 LAP ON PLAN LAP 0.20 Ln 0.20 Ln

BAND BEAM DEPTH.


U.N.O.

D
0.10 Ln1 0.10 Ln1 0.10 Ln2
SEE NOTE 7 MAX MAX SUPPORT BARS.
ALTERNATE
12 BAR DIA. BOTTOM BARS 150 MIN. U.N.O. 150 MIN. U.N.O.
Ln 1 STAGGERED. Ln 2

STANDARD COG SECTION A-A ALONG BAND BEAM


WHERE SHOWN ON
N16-1000 SUPPORT
PLAN. SEE NOTE 7.
0.30 Ls 1 0.30 Ls BARS (NOT REQ'D. 0.30 Ls
WHERE SHEAR
STANDARD 0.20 Ls 1 0.20 Ls A LIGS ARE 0.20 Ls DISTRIBUTION

SLAB THICKNESS.
COG SEE NOTE 7 BARS REFER
U.N.O. SPECIFIED).
NOTE 2.

T
INDICATIVE EDGE BEAM.
REFER OTHER DETAILS 150 150
0.10 Ls1
WHERE THE END ALTERNATE BTM.
SUPPORT IS A WALL. ALTERNATE BTM.
BARS STAGGERED.
BARS STAGGERED.
0.10 Ls1 A 0.10 Ls2
GREATER OF 12 BAR DIA.
AND "T" Ls1 BAND WIDTH Ls2
AS SHOWN ON PLAN.
TYPICAL SECTION THROUGH BAND BEAM (NORMAL SLAB REINFORCEMENT)

NOTES:
1. FOR REINFORCEMENT SIZE & NUMBER SEE PLANS. 7. LONG AND SHORT TOP BARS SHALL BE PLACED ALTERNATELY, WITH AT
LEAST 50% OF THESE BEING THE LONGER BAR.
2. WHEREVER SLAB REINFORCEMENT IS CALLED UP IN ONE DIRECTION, DISTRIBUTION
BARS ARE REQUIRED IN THE TRANSVERSE DIRECTION. ALL TOP AND BTM. 8. BARS MAY BE ADJUSTED SIDEWAYS TO AVOID COLUMN BARS.
DISTRIBUTION BARS NOT SHOWN ON PLAN TO BE N12-300 WITH 300 LAPS. NOT
REQUIRED WHERE FABRIC IS SPECIFIED. 9. REFER PLANS FOR LIGATURE REQUIREMENTS TO BAND BEAM.

3. DETAILS ABOVE APPLY UNLESS SHOWN OTHERWISE ON PLANS. 10. BUILDER IS TO PROVIDE ADEQUATE BAR CHAIRS OR SUPPORT CAGES TO
SUPPORT BAND BEAM TOP REINFORCEMENT.
4. THE ABOVE ARRANGEMENT ONLY APPLIES WHERE THE RATIO OF THE LONGER TO
SHORTER OF ANY TWO ADJACENT SPANS DOES NOT EXCEED 1.2. 11. BOTTOM FABRIC SHALL BE IN ONE PIECE IN THE SPAN DIRECTION, WITH
MAIN WIRES LOWERMOST. WHERE SPANS ARE GREATER THAN 6000 NOM.
5. FOR PRIMARY AND SECONDARY DIRECTIONS OF REINFORCEMENT SEE PLANS. A STANDARD FABRIC LAP (TO AS 3600) SHALL BE MADE WITHIN 0.30 Ln
OF A SUPPORT.
6. Ls OR Ln IS THE GREATER OF TWO CONSECUTIVE SPANS (EG. Ls1 & Ls2, Ln1 & 12.
Ln2). TOP FABRIC SHALL BE LAPPED WITHIN THE MIDDLE THIRD OF A SPAN.

TYPICAL BAND BEAM & SLAB DETAILS


(N.T.S.)

ARE SHOWN ADD 2N16 TOP & BTM. EACH SIDE


OF HOLE.

600
MINIMUM LAP SPLICES FOR BARS
SPLICE(mm)
600

LESS THAN 300mm MORE THAN 300mm


BAR CONCRETE BELOW BAR CONCRETE BELOW BAR
OR VERTICAL BAR
CONCRETE GRADE CONCRETE GRADE VO
SIZE 25 MPa > 32 MPa 25 MPa > 32 MPa
ID
IN
SL
AB
N12 300 300 400 400
N16 450 450 550 550
N20 600 550 750 700
N24 850 750 1050 950
N28 1050 900 1300 1150
N32 1250 1150 1600 1400
TYPICAL PENETRATION IN FLOOR SLAB DETAIL
N36 1550 1400 1950 1750
NOTE: 1. FOR HOLES LESS THAN 300 x 300mm, BARS TO BE RE-ARRANGED AROUND HOLE.
NOTES: 2. FOR HOLES GREATER THAN 300 x 300mm, BUT LESS THAN 1000 x 1000mm
1. THESE SPLICE LENGTHS APPLY FOR ALL BEAMS, SLABS AND WALLS U.N.O. USE ABOVE DETAIL.
2. THESE SPLICE LENGTHS ARE BASED ON THE FOLLOWING MINIMUM COVER
TO THE BAR: 3. FOR HOLES GREATER THAN 1000 x 1000mm REFER TO ENGINEERS PLANS.
SLABS, WALLS - GREATER OF 25mm OR BAR DIA.
BEAMS - 40mm

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof CONCRETE DETAILS - SHEET 2 MR. D. LAND 1:20
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S10 1
BUILDER TO CAPPING BEAM.
REFER PLAN FOR VERIFY ONSITE EXISTING APARTMENT REFER PLAN FOR EXISTING APARTMENT
REFER DRG. S4 FOR
REINFORCEMENT REINFORCEMENT
REINFORCEMENT
1480

GROUND SLAB GROUND SLAB

500 TYP.
EXISTING FOOTING.
BUILDER TO VERIFY
ONSITE DO NOT UNDERMINE
EXISTING FOOTING.
CLEAN SCABBLED BUILDER TO VERIFY
SURFACE ONSITE

CAPPING BEAM.
REFER DRG. S4 FOR
REINFORCEMENT

REFER DRG. S3 FOR REFER DRG. S3 FOR


BLOCK WALL DETAILS BLOCK WALL DETAILS SHOTCRETE WALL. REFER
DRG. S4 FOR DETAIL

SHOTCRETE WALL. REFER


REFER PLAN FOR DRG. S4 FOR DETAIL REFER PLAN FOR
REINFORCEMENT REINFORCEMENT

BASEMENT SLAB BASEMENT SLAB

0.2mm THICK POLYTHENE 1


SF

1
MEMBRANE ON 6mm

SF
SOLDIER PILE SOLDIER PILE
SCREENINGS LAID OVER
20mm SCREENINGS (75mm
MIN. DEPTH).
50mm BLINDING
REFER FOOTING PLAN CONCRETE.
FOR REINFORCEMENT

SECTION 1
S6 S7

SECTION 2
S6 S7

LINE OF EASEMENT
BOUNDARY LINE

BOUNDARY LINE
GROUND SLAB

GROUND SLAB
EXISTING LIGHTWEIGHT SHED
500 TYP. 500 TYP.

180 THICK INSITU DOWN 180 THICK INSITU DOWN


REFER PLAN FOR TURN WALL. REFER PLAN FOR TURN WALL.
REINFORCEMENT N16-200 E.W CENTRAL REINFORCEMENT N16-200 E.W CENTRAL

CLEAN SCABBLED CLEAN SCABBLED


SURFACE SURFACE

CAPPING BEAM. REFER DRG. EXISTING FOOTING.


S4 FOR REINFORCEMENT BUILDER TO VERIFY
ONSITE

PROVIDE VOID FORMER CAPPING BEAM. REFER DRG.


BETWEEN FOOTING S4 FOR REINFORCEMENT

SHOTCRETE WALL. REFER SHOTCRETE WALL. REFER


REFER PLAN FOR DRG. S4 FOR DETAIL REFER PLAN FOR DRG. S4 FOR DETAIL
REINFORCEMENT REINFORCEMENT

BASEMENT SLAB BASEMENT SLAB

SOLDIER PILE SOLDIER PILE

SECTION 3 SECTION 4
S6 S7
S6 S7

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof CONCRETE DETAILS - SHEET 3 MR. D. LAND 1:20 (U.N.O)
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S11 1
BOUNDARY LINE
BOUNDARY LINE
RETAINING BLOCKWALL.
RETAINING BLOCKWALL. REFER DRG. S12 FOR
REFER DRG. S12 FOR DETAILS
DETAILS

REFER PLAN FOR


REINFORCEMENT
100 MIN.
RAMP SLAB

A.G DRAIN BY
OTHERS

EXISTING FOOTING. RETAINING BLOCKWALL. RETAINING BLOCKWALL.


REFER DRG. S12 FOR REFER DRG. S12 FOR

2
2
BUILDER TO VERIFY

SF
SF
ONSITE DETAILS DETAILS EXISTING FOOTING.
BUILDER TO VERIFY
100 MIN. ONSITE
REFER PLAN FOR
REINFORCEMENT
A.G DRAIN BY
RAMP SLAB OTHERS

BUILDER TO ENSURE THAT 50mm BLINDING CONCRETE REFER PLAN FOR


DO NOT UNDERMINE (f'c = 150 mPa ) REINFORCEMENT.
EXISTING FOOTING
1
UNDERPIN TO EXISTING

2
SF

SF
FOOTING. REFER RETENTION
PLAN FOR DETAILS
SECTION 6
S6 S7

50mm BLINDING CONCRETE REFER PLAN FOR


(f'c = 150 mPa ) REINFORCEMENT.

SECTION 5
S6 S7

BOUNDARY LINE
REFER PLAN FOR
REINFORCEMENT REFER ARCHITECTS REFER PLAN FOR
GROUND SLAB DRG. FOR WALL DETAIL REINFORCEMENT
BOUNDARY LINE

EXISTING BUILDING 180 THICK INSITU DOWN


SL81 B
REFER PLAN FOR TURN WALL.
ADDITIONAL
REINFORCEMENT N16-200 E.W CENTRAL
NSL
GROUND SLAB REFER PLAN
N.G.L
FOR LIGS CLEAN SCABBLED
SURFACE
EXISTING FOOTING.
BUILDER TO VERIFY
ONSITE

SECTION 8
CAPPING BEAM. REFER DRG.
S4 FOR REINFORCEMENT
CLEAN SCABBLED S7
SURFACE

CAPPING BEAM. 50mm BLINDING


CONCRETE SITE RETETION.
REFER DRG. S4 FOR REFER DRG. S4
REINFORCEMENT (f'c = 150 mPa )
FOR DETAIL

REFER DRG. S13 FOR WALL


SHOTCRETE WALL. REFER CONNECTION DETAIL
REFER PLAN FOR DRG. S4 FOR DETAIL
REINFORCEMENT REFER PLAN FOR
REINFORCEMENT GROUND SLAB
BASEMENT SLAB

SOLDIER PILE

SECTION 9
S7

SECTION 7
S6 S7

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof CONCRETE DETAILS - SHEET 4 MR. D. LAND 1:20 (U.N.O)
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S12 1
REFER WALL ELEVATION REFER WALL ELEVATION REFER WALL ELEVATION
FOR REINFORCEMENT FOR REINFORCEMENT FOR REINFORCEMENT
(TYP.) (TYP.) (TYP.)
CONCRETE SLAB

300 COG
N16-300 STARTER BARS

LAP.

LAP.

LAP.
FLOOR TRACK.

500

500

500
600

300
REFER WALL ELEVATION
FOR REINFORCEMENT
(TYP.)
CONCRETE SLAB CONCRETE SLAB CONCRETE SLAB
LAP.

FLOOR TRACK.
500

REFER WALL ELEVATION


FOR REINFORCEMENT
MASONRY NAILS MASONRY NAILS MASONRY NAILS
(TYP.)
AT 600 CTS. AT 600 CTS. AT 600 CTS.

300 COG

MASONRY NAILS
AT 600 CTS.

TYPICAL WALL AT BASE DETAIL TYPICAL TOP OF TYPICAL SLAB TO TYPICAL SLAB TO TYPICAL SLAB TO
WALL END DETAIL INTERNAL WALL DETAIL EXTERNAL WALL DETAIL STAIR WALL DETAIL

CONCRETE SLAB

STUDS TEE JUNCTION STUD


FIXED TO WALL FLASHING IF REQUIRED.
FACE AT 450 CTS.

FIRE RATED SEALANT


& BACKING STRIPS..

STUDS
CONCRETE
COVER
N12-500 LIGS

REFER WALL REFER ELEVATION FOR


ELEVATION FOR REINFORCEMENT
REINFORCEMENT (TYP.) OTHERWISE USE 1N16 T&B
STUDS

'DINCEL' CLOSING
STUDS.

PROVIDE 300 HOOK


TO END OF ALL
HORIZONTAL BARS CLOSING STUD.

CONSTRUCTION
TYPICAL WALL TO WALL CONNECTION TYPICAL WALL CORNER DETAIL MOVEMENT JOINT DETAIL TYPICAL HEADER BEAM DETAIL

NOTE:
1. THE WALL SUPPLIERS SHALL SUBMIT FULL DETAILS AND/OR
COMPUTATIONS FOR REVIEW BY THE ENGINEER IF CONSTRUCTION
DETAILS DIFFER TO GIVEN DETAILS ON THIS DRAWING.
2. CONCRETE MIX SHALL BE REFER TO WALL MANUFACTURER'S
SPECIFICATION.

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof FORMWORK WALL CONNECTION MR. D. LAND 1:10
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni
DETAILS nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S13 1
Member Schedule
Mark Member Size MAX. SPAN MAX. CANTILEVER
3FB1 410UB54 7,400

3FB2 240x45 MGP10 1,400


D D
3FB3 2 No. 290x45 F17 KDHW 3,000

R1 3FB4 310UB40 6,300

G
2
L2

SC
4FB1 2 No. 290x45 MGP10 3,000
G
4FB2 240x45 MGP10 1,000

3FB1 4FB3 200PFC + 100x10 EA 3,300

2
SC

SC

SC
G
FJ1

L3
L1 240x45 MGP10 1,000

L2
UNIT 3 LINE OF UPPER 290x45 MGP10 2,000

L2
FLOOR (TYP.)
L3 300PFC + 100x8 EA 3,800

L4 300PFC + 100x8 EA 4,600

2
SC

3FB4
SHADE
DENOTES LOAD
DS DOUBLE 90x45 MGP10 -
BEARING WALL P1 100x100 CYPRESS -

L2
D
(TYP.)
P2 2 No. 90x45 F17 KDHW -

C1 89x89x5 SHS -
3FB3

DS

P2

P2
SC1/SC2 89x89x5 SHS -
3FB2 G 3FB3 3FB2

P2
FJ1

L1
PSW4530 POSI @ 450 CTS MAX. OR -
HYJOIT-TEC BEAM TO MAN. DESIGN & SPEC.

D
D

D
G
G WP1 WP1
BRACING
WP1 WP1

G
ALL WALLS TO BE BRACED IN ACCORDANCE WITH
G

G
FJ1 AS 1684 STANDARDS.

G
BRACING SHALL INITIALLY BE PLACED IN
P2

DS
P2

P2

L1
EXTERNAL WALLS AND WHERE POSSIBLE AT
4FB1 4FB1 4FB2 THE CORNER OF THE BUILDING. REMAINING
P1

L1 BRACING SHALL THEN BE EVENLY


DISTRIBUTED THROUHOUT THE INTERNAL
WALLS.

G
R1

G
UNIT 4
MINIMUM LENGTH OF PLYWOOD BRACING TO
G BE 900 MM.
4FB3

ALL FRAMING MEMBERS ARE TO BE ANCHORED


AGAINST UPLIFT IN ACCORDANCE WITH 1684.
SHADED REGION

L1
DENOTES
BALCONY AREAS G
L1
P2

4FB2 4FB2
P1

D
G

G
2 L4 2 L1 L1
FJ1 SC SC

G G G

LEVEL 1 FRAMING PLAN


G - DENOTES TYPE G PLYWOOD (UNIT TYPE A). REFER TO DRAWING S16 FOR DETAILS
D - DENOTES TYPE D METAL STRAP (UNIT TYPE B) REFER TIMBER FRAMING TO AS1684
AND DRAWING S16 FOR DETAILS

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof LEVEL 1 FRAMING PLAN MR. D. LAND 1:50 (A1)
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S14 1
ROOF TRUSS NOTES

1. ROOF TRUSSES SHALL BE DESIGNED, FABRICATED, HANDLED AND


ROOF TRUSS FOR TILE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS
ROOF BY OTHERS. REFER SPECIFICATIONS.
ADJACENT NOTES FOR
DETAILS 2. COMPUTATIONS AND COMPLETE SHOP DRAWINGS ARE TO BE
SUBMITTED TO THE ENGINEER FOR CHECKING PRIOR TO
FABRICATION OF TRUSSES.

3. TRUSSES SHOULD BE POSITIONED DIRECTLY OVER WALL STUDS,


WHERE LARGE CONCENTRATED LOADS FROM 'HEAVY TRUSSES'
SUCH AS GIRDER AND HIP TRUSSES OCCUR, THE TRUSS DRAWINGS
D D SHALL SPECIFY DOUBLE OR TRIPLE STUD SUPPORTS AS REQUIRED.

4. ROOF TRUSSES SHALL BE CONNECTED TO EXTERNAL LOAD


UL2

G
BEARING WALLS WITH. 1 No. 'TRIP-L-GRIP' EACH END.

G
5. ALL INTERNAL WALLS ARE TYPICALLY NON LOAD BEARING AND

UL2

D
SHALL BE CONNECTED TO TRUSSES USING INTERNAL WALL
BRACKETS.

UL2
UNIT 3
6. PERMANENT ROOF BRACING ('SPEEDBRACE' OR EQUIVALENT)
SHALL BE FIXED IN ACCORDANCE WITH THE TRUSS DRAWINGS AND

G
THE MANUFACTURERS SPECIFICATIONS.

UL2
G

D
STUD WALL BRACING
G

UNDER (TYP.) ALL WALLS TO BE BRACED IN ACCORDANCE WITH


AS 1684 STANDARDS.
BRACING SHALL INITIALLY BE PLACED IN
D EXTERNAL WALLS AND WHERE POSSIBLE AT

UL2
THE CORNER OF THE BUILDING. REMAINING
UL1

BRACING SHALL THEN BE EVENLY

D
DISTRIBUTED THROUHOUT THE INTERNAL
WALLS.

G
MINIMUM LENGTH OF PLYWOOD BRACING TO
BE 900 MM.

ALL FRAMING MEMBERS ARE TO BE ANCHORED


AGAINST UPLIFT IN ACCORDANCE WITH 1684.
G

UL2
G G
Member Schedule
UNIT 4

UL1
Mark Member Size MAX. SPAN MAX. CANTILEVER
UL3

G G UL1 190x45 MGP10 1,000

HATCH UL2 240x45 MGP10 2,000


DENOTES
D LIGHTWEIGHT UL3 290x45 (F17) KDHW 2,800
CLADDING
(TYP.)
D

D
G
UL1 UL2 UL2

G G G

ROOF FRAMING PLAN


G - DENOTES TYPE G PLYWOOD (UNIT TYPE A). REFER TO DRAWING S16 FOR DETAILS
D - DENOTES TYPE D METAL STRAP (UNIT TYPE B) REFER TIMBER FRAMING TO AS1684
AND DRAWING S16 FOR DETAILS

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof ROOF FRAMING PLAN MR. D. LAND 1:50 (A1)
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S15 1
WALL BRACING DETAILS - TYPE D WALL BRACING DETAILS - TYPE G WALL BRACING DETAILS - TYPE M
(Double Metal Strap): (Plywood): WHERE REQUIRED, ONE ROW OF (Hardboard):
TENSIONED GALVANISED METAL STRAPS NOGGING, STAGGERED OR SINGLE WHERE REQUIRED, ONE ROW OF
30 x 0.8mm (OR EQUIVALENT) NAILED TO 30 x 0.8mm METAL STRAP LOOPED FIXING TO TIMBER FRAME: 150mm LINE, AT HALF WALL HEIGHT. MINIMUM HARDBOARD THICKNESS 4.8mm NOGGING, STAGGERED OR SINGLE
PLATES WITH 4/ 30 x 2.8mmØ GALVANISED OVER PLATE AND FIXED TO STUD WITH 4/ 30 x 30 x 2.8mmØ FLATHEAD NAILS MINIMUM BRACING PANEL WIDTH 460mm LINE, AT HALF WALL HEIGHT.
2.8mmØ FLATHEAD NAILS TO EACH END. 40mm STAGGERED
FLATHEAD NAILS TO EACH END. OR
OR EQUIVALENT @ 150 CTS. FIXING TO TIMBER FRAME:
PROVIDE SINGLE STRAPS TO BOTH SIDES, WITH TO ALL PLYWOOD VERTICAL HORIZONTAL 30 x 2.8mmØ FLATHEAD
4 NAILS PER STRAP END, OR EQUIVALENT AND HORIZONTAL EDGES:- NAILS OR EQUIVALENT.
150mmBUTT JOINTS
ANCHORS OR OTHER FASTENERS. STUDS, TOP & BTM. PLATES

150mm
PERMITTED, NALIS SHALL BE LOCATED
TYPICAL FIXINGS FOR AND NOGGINGS. PROVIDED FIXED A MINIMUM OF 10mm FROM

150mm
METAL STRAPS TO PLATE TO NOGGING AT THE VERTICAL EDGES AND
150 CTS. 15mm FROM THE TOP AND
BOTTOM EDGES. 150mm
75mm HAND DRIVEN
MASONRY NAILS (WITH TECO TRIP-L-GRIP 1.2 x 30 WIDE HOOP IRON

35
WASHER) @ 900 CTS. STRAP x 1000 LG. PROVIDE 5
300mm SPACING PERMITTED
EAM
No. 2.8 mm DIAM. CLOUTS TO
FOR FASTENERS TO 460 MIN
300mm SPACING TIMBER BEAM & POST.
B
INTERMEDIATE STUDS WHERE PANEL WIDTH 40mm PERMITTED FOR EL
STE
CTR. OF PANEL WIDTH
APPLICABLE (900 WIDE PANEL
FASTENER 65mm FASTENERS TO BER

300mm
65
FROM SLAB WIDTH SHOWN) INTERMEDIATE STUDS
40mm TIM M
BEA
EDGE WHERE BEARING PLATE REFER TO
APPLICABLE MEMBER SCHEDULE
PLYWOOD BRACING BRACED SECTION LENGTH 200 6CFW TO STEEL BEAM
MIN
(BRACING CAPACITY - 3.4 kN/m) . 10mm LAYER 20 MPa NON
INTERMEDIATE FIXINGS FOR BOTTOM HARDBOARD BRACING BRACED SECTION LENGTH
°

TOP SHRINK LEVELLING GROUT


-60

(BRACING CAPACITY - 6.0 kN/m) DS, TS, P1, PLA


WALL PLATE TO CONCRETE SLAB P2, P3
TE

150mm
M10 BOLT @ EACH END END ANCHORING
30

(NOMINAL FIXING) MINIMUM PLYWOOD WHERE TOP AND BOTTOM PLATES AND 1200mm MAX. CTS REFER DETAIL
WP1
1-M8 ANKASCREW ANCHOR (WITH WASHER) THICKNESS (mm) IN BRACED SECTIONS ARE NOT IN BETWEEN ABOVE
BRACED SECTION LENGTH TYPE D - DOUBLE DIAGONAL TENSION OR METAL [Ramset Part No. AS08100H] CONTINUOUS THEY MUST BE = =
(65mm MIN. EMBEDMENT) Stress Stud Spacing (mm) SPLICED AS SHOWN IN THIS DETAIL
1800 TO 2700 STRAP BRACES (BRACING CAPACITY - 3.0 kN/m) TO EACH END OF BRACED SECTION Grade
1.2x30mm HOOP IRON STRAP

35
LENGTH 100mm FROM END. SPLICE PLATE MUST BE
CTR. OF FASTENER 65mm FROM SLAB 450 600 (PLAN VIEW) 6-75mm NAILS @ 1500 MAX CTS x 1000 LONG
1-M10 BOLT (AND 1-M10 BOLT (AND OF SAME SIZE AND
WASHERS) TO END UPPER LEVEL EDGE WHERE APPLICABLE
STRESS GRADE AS TOP EACH SIDE STAGGERED
WASHERS) TO BRACING No Nogging
OF BRACING PANEL BRACING WALL AND BOTTOM PLATES.
END OF BRACING WALL (except horizontal butt joints)
PANEL. 65 NOGGING @ 800 (ELEVATION)
F8 7 9
FLOOR F11 4.5 7 MAX. CTS.
550 OR 400 ROOF TRUSSES TO BRICKWALL PERSPECTIVE TIMBER BEAM TO PERSPECTIVE BEAM TO BRICK
SOLID TIMBER
JOISTS
BLOCKING HARD F14 4 6 SPLICE DETAIL CONNECTION DETAIL TIMBER POST CONNECTION DETAIL WALL CONNECTION DETAIL
AGAINST BOLT END FIXING OF BOTTOM WALL PLATE TO SLAB F27 3 4.5 FOR TOP & BOTTOM PLATES SECOND SKIN OF BRICKWORK NOT SHOWN FOR CLARITY
SOLID TIMBER BLOCKING
HARD AGAINST BOLT 1-M10 BOLT (AND One Row of Nogging END STUD
WASHERS) TO END OF
BRACING WALL PARALLEL TO JOISTS BRACING WALL AT BRACING PANEL UPPER LEVEL F8 7 7 BLOCKING @ 800
(INTERNAL BRACING WALL SHOWN) RIGHT ANGLES TO JOISTS BRACING WALL F11 4.5 4.5 END STUD MAX. CTS.
2 NAILS
F14 4 4
TO EACH
END FIXING OF BOTTOM WALL PLATE FLOOR
F27 3 3 NOG
TO TIMBER FRAME JOISTS
WHERE TOP AND BOTTOM PLATES IN
BRACED SECTIONS ARE NOT
INTERSECTING WALLS
TIMBER
SOLID TIMBER
CONTINUOUS THEY MUST BE SPLICED
BLOCKING
1-M10 BOLT (AND PACKER AS SHOWN IN DETAIL THIS PAGE.
WALL JUNCTION DETAIL TRUSS FRAMING TRUSS FRAMING
35

UPPER LEVEL 1-M8 ANKASCREW ANCHOR @ 800 MAX.


WASHERS) TO END OF BY OTHERS STUD WALL FIX TO STEEL BEAM BY OTHERS
BRACING PANEL BRACING WALL (WITH WASHER) END FIXING OF BOTTOM WALL PLATE TO TIMBER FRAME: (APPLIES TO ALL BRACING TYPES) CTS. USING M10 BOLTS @ 900 CTS
Ramset Part No.
2/ NAILING UPPER LEVEL BRICK PIER
FLOOR JOISTS AS08100H] WHERE "BRACED SECTION LENGTH" IS 900mm OR 1-M10 BOLT (AND
PLATES TO EACH 75mm HAND DRIVEN
35

BRACING WALL
END OF 65 (65mm MIN. EMBEDMENT)
MASONRY NAILS (WITH
LESS AND CONSISTS OF A SINGLE BRACING PANEL WASHERS) TO EACH END FJ FJ FJ FJ
TO EACH END OF BRACED INTERMEDIATE FIXING IS NOT REQUIRED. OF BRACING PANEL AND FLOOR
BRIDGING, WITH SECTION LENGTH. WASHER) @ 900 CTS.
@ 1200 CTS (MAX) JOISTS
6/2.8mmØ NAILS CTR. OF FASTENER 65mm
TO EACH FACE 120 x 45 F5 PINE BRIDGING FROM SLAB EDGE WHERE CTR. OF FOR EXTERNAL BRACING WALLS, WALLS 30x1.2 HOOP IRON STRAP BUILT TECO BRACKET TECO BRACKET
(TYPICAL) ON FLAT/EDGE @ 1200 CTS 65 FASTENER 65mm PERPENDICULAR TO JOISTS & INTERNAL 2/ NAILING PLATES 1000mm DOWN INTO BRICKWORK
APPLICABLE
FROM SLAB WALLS DIRECTLY OVER JOISTS/BEAMS: TO EACH END OF 120 x 45 F5 PINE CORNER TIMBER NAILING PLATE,
M12 BOLTS @900 CTS
BRACING WALL PARALLEL TO JOISTS END FIXING OF EDGE WHERE BRIDGING ON
(NO STUD WALL UNDER) BOTTOM PLATE TO SLAB APPLICABLE - NAIL/FIX TO JOISTS/BEAMS UNDER
BRIDGING, WITH
6/2.8mmØ NAILS TO FLAT/ EDGE @ LOCATIONS
INTERMEDIATE FIXINGS FOR
@ 600 MAX. CTS. EACH FACE (TYP) 1200 CTS
200 LONG EXTERNAL STUD FRAME TO EXTERNAL STUD FRAME TO
INTERMEDIATE FIXINGS FOR FOR INTERNAL BRACING WALLS WITH NO
BOTTOM WALL PLATE TO
BOTTOM WALL PLATE TO JOIST UNDER:
STUD SIZED
BLOCKING @
TIMBER BEAM TO BRICK PIER DETAIL STEEL BEAM DETAIL TIMBER BEAM DETAIL
CONCRETE SLAB - USE THIS DETAIL
(NOMINAL FIXING) TIMBER FRAME 800 MAX. CTS.

15mm MIN
10 CLEAT PL 6CFW TO STEEL BEAM
10 CLEAT PLATE WELD TO
2 M20 BOLTS THROUGH TIMBER BEAM
STEEL BEAM 2 M20 BOLTS TO
10 CAP PL WELDED TO SHS 10mm STIFFNER PLATE
TIM
TIMBER BEAM
4 M20 BOLTS TO TO EACH M
BEA
WELDED TO STEEL BEAM
B
L
BEA ER
SIDE OF STEEL BEAM
E
STE STEEL BEAM TIMBER BEAM M D MAX

EAM

D/2 MIN
10 PLATE WELDED
6 CFW 300 EACH END
L B TO STEEL BEAM
THEN HIT 150 MISS 150 SHS
TOP
PLA
TOP PLATE
STEE 10 CAP PL WELDED TO SHS
4 M20 BOLTS TO STEEL BEAM
ALTERNATING EACH SIDE T E 10 CLEAT PL OFF TOE OF BEAM TOP
BACKFILL CAVITY WITH 2 M10 BOLT THROUGH TOP PLATE PLA
1:1 MIX OF MORTAR TE STEEL BEAM

D
PFC SUPPORT
VERTICAL PLATE
REFER TO SCHEDULE (REFER MEMBER SCHEDULE)
6mm CFW TO HORIZONTAL
10 CLEAT PL
HORIZONTAL PLATE TIMBER TO STEEL BEAM TO 6CFW
(REFER MEMBER SCHEDULE) SHS 2 M20 BOLTS (TYP)
ANGLE 200mm MIN END BEARING WALL CONNECTION DETAIL
REFER TO SCHEDULE M12 BOLTS TOP & BOTTOM
AND AT 1 / 3 POINTS.
M12 BOLTS TOP & BOTTOM STEEL COLUMN

PFC AND ANGLE DETAIL T - LINTEL DETAIL PERSPECTIVE STEEL BEAM TO SHS AND AT 1 / 3 POINTS.
CONNECTION DETAIL PERSPECTIVE CANTILEVERING STEEL BEAM CHAMFER DETAIL
BEAM TO SHS CONNECTION DETAIL
25 WIDE GALVANIZED BASE PLATE PLAN
STEEL STRAP. CLOUT
FIX TO MULLION
BUILDER TO ENSURE 15mm CLEAR
DISTANCE BETWEEN TOP-BOTTOM 10 BASE PLATE
OF STEEL BEAM AND 6 CFW TO 'C1' ON
M
BEA FLOORING-PLASTER. 20 NOM. GROUT
E R M
BEA
B BUILDER TO ENSURE 15mm 4M20 CHEMSET
TIMBER BEAM
TIM CLEAR DISTANCE BETWEEN
AS SCHEDULE TOP & BOTTOM OF STEEL
E L REO502 ANCHORS

STE
M BEAM AND FLOORING/PLASTER. 150 EMBEDMENT.
R BEA M
POSI JOIST
BE 15mm MIN BEA
4d TIM EEL
150

2 M12 BOLTS ST

STE FJ1
5d TIM
BER
TIM
BER EL
BEA
BEA
M BEA
TIMBER POST
M M
P-
P-

BOTTOM CHORD SUPPORT


10 CLEAT PL 6CFW TO
STEEL BEAM
150x150x6 EA x DEPTH OF BEAM 2 M20 BOLTS THROUGH 10 CLEAT PL 6CFW TO STEEL BEAM
EACH SIDE OF CONNECTING BEAM TIMBER BEAM 2 M20 BOLTS THROUGH STEEL BEAM

DOUBLE BEAM TO TIMBER PERSPECTIVE TIMBER BEAM TO


POST CONNECTION DETAIL TIMBER POST CONNECTION DETAIL PERSPECTIVE TIMBER BEAM TO PERSPECTIVE TIMBER BEAM TO PERSPECTIVE STEEL BEAM TO FLOOR JOIST INTO WALL TYPICAL POST BASE DETAILS
TIMBER BEAM CONNECTION DETAIL STEEL BEAM CONNECTION DETAIL STEEL BEAM CONNECTION DETAIL
N.T.S

DRAWING Designed by CLIENT Scale @ A1 SIZE SHEET


HTD Consultants Pty Ltd ht
thsidrawnigsandthedesg
inshownhereonsithepropertyof FRAMING DETAILS MR. D. LAND 1:20
Structural & Civil Engineer Drawn by
htdconsultantspty.ltd.andshallnotbecopeidnorreproducedni nh Job No.

1 24/11/17 CONSTRUCTION ISSUE HT


partorni wholeni anyformwtihoutthewrtitenpermsisoinof 70 Victoria street, Carlton 3053
Checked by PROJECT
17039
No. Date Revision By No. Date Revision By
htdconsultantspty.ltd.andshallbeusedonlybythecleintof Mobile: 0412 086 282 ht Drawing No. Rev.
htdconsultantspty.ltd.fortheprojectforwhcihtiwasprovdied. Email: admin@htdconsultants.com.au PROPOSED TOWNHOUSES & ALTERATION
CONSTRUCTION ISSUE ABN : 96 166 634 644 DO NOT SCALE THIS DRAWING WORKS AT 4 HYTON CRESCENT, KEW S16 1