Solenoid modular poppet valves VP-series

Shown: VP-12
Solenoid directional valves Pressure: 5000 psi
product line
Collet-Lok®

• Dual poppet valve design for zero Max. Flow: 915 in3/min
internal leakage
• Inlet check-valve standard E Válvulas de control
• High cycle switching F Electrodistributeurs
• Stackable to 8 valve stations high D Wegesitzventile
Swing clamps

• 250-5000 psi operational pressure


• Oil flow capacity 427 in3/min @ 5000 psi
• Oil flow capacity 915 in3/min @ 0 psi
• G1/4" oil connections and
integrated filtration
Options
Work supports

99_017

• 24 VDC and 110 VAC available


WM-10 series
manifolds
VP-series
Solenoid directional valves control VP series 139 ▸
the direction of the oil flow to each
cylinder port. Tie rod kits
Linear clamps

Application
5.59

With the use of a -12 manifold,


Pressure 139 ▸
switch ports at
these valves allow quick and both sides for
easy assembly of hydraulic control PSCK-8, 9 Oil flow vs pressure drop
valves on your Enerpac
ZW-series pump. For remote
1.57

131
Power sources

mounting of these valves use Flow control ports at


both sides for VFC-3
a WM-10 manifold. 102

Oil pressure (psi)


G1/4"
A B
1.10
1.57

73
VP-series
2.36
.47

43
3.62
0
Valves

0 100 200 300 400 500


Oil flow (in3/min)
Product selection
Voltage @ current Model Flow path Used with cylinder(s)
number

at 50/60 Hz
t 4/3 Closed center
24 VDC @ 1.13 A VP-11 A B 1x Dbl-act.
110 VAC @ 500 mA VP-12 1x Dbl-act.
P T
t 4/3 Float center
24 VDC @ 1.13 A VP-21 A B 1x Dbl-act.
z Enerpac VP-series valves
mounted on -12 manifold, 110 VAC @ 500 mA VP-22 1x Dbl-act.
mounted on a ZW-series P T
workholding pump. t 3/2 Normally closed
24 VDC @ 1.13 A VP-31 1x Dbl-act. / 2x Sgl-act.
110 VAC @ 500 mA VP-32 1x Dbl-act. / 2x Sgl-act.

t 3/2 Normally open


24 VDC @ 1.13 A VP-41 1x Dbl-act. / 2x Sgl-act.
110 VAC @ 500 mA VP-42 1x Dbl-act. / 2x Sgl-act.

t 3/2 1 port normally closed, 1 port normally open


24 VDC @ 1.13 A VP-51 1x Dbl-act. / 2x Sgl-act.
110 VAC @ 500 mA VP-52 1x Dbl-act. / 2x Sgl-act.
99_030

Note: DIN 43650 electrical connector included. Valve weight 6.5 lbs (3,0 kg.).

136 ®
2-position poppet valves VA, VS, VD-series
Shown: VST-1401D, VSS-2210D
Zero leakage poppet valves Pressure: 0-5000 psi
increase efficiency
product line
Collet-Lok®

Flow: 690 in3/min max.


• Poppet valve design for zero leakage Voltage: 115 VAC, 24 VDC
• 4-way, 2-position float offset or normally open
• D03 or CETOP3 mounting pattern E Electroválvulas
• DIN-standard rectifier plugs for easy connection F Electrodistributeurs
Swing clamps

to power source
D Elektromagnetische Ventile
• Air operated models eliminate need for electricity
• Including O-rings and mounting bolts A B A B PTBA
G
• SAE manifold ports simplify plumbing P T PTBA
P T
• Inline check valve provides positive load holding
Work supports

99_111

Options
D03 Manifolds
VSS, VST-series
MB-series
Solenoid and air piloted VAS/VAT
directional control valves. Poppet 144 ▸
5.25
design for zero leakage promote .25
Linear clamps

system efficiency. Increases the .81 2.25 Fittings


life of your workholding pump by

1.30
1.00
decreasing internal valve leakage.
194 ▸
Application

2.06
2.00
Advance and retract for single- Important
and double-acting cylinders.
2.00
Power sources

The valves require check valves For multiple circuit


VSS applications, the VD1P inline
for positive load holding and
can be installed for the same check valve is recommended
to prevent pressure drop on
independent operation with
3.04

the holding circuit.


single-acting cylinders by
2.00

blocking the B port. Order bolt kit BKD-71 to


mount VD1P with VAS/VSS/
T P MB-1 manifold. VST valves.
To be ordered
Valves

separately.
5.93
VST VD1P
3.04
2.00

MB-1 manifold.
1.58

To be ordered separately. B
Inline check valve
A

5.93
A B

Product selection
Valve flow path Solenoid Model Hydr. Pressure Pressure Max.
z VSS-2210D mounted directly voltage number symbol range drop 1) oil flow
@ current
on a Turbo II air pump for use on
positive clamping fixture. at 50/60 Hz psi psi in3/min
t Solenoid poppet valves – Normally open
4-way, 2 position 60-100 psi max. VAS-0710D A B 0-5000 180 690
4-way, 2 position 24VDC @ 1.60 A VSS-1410D 0-5000 180 690
P T
4-way, 2 position 115VAC @ .40 A VSS-2210D 0-5000 180 690
t Solenoid poppet valves – Normally closed
4-way, 2 position 60-100 psi max. VAT-0710D A B 0-5000 180 690
4-way, 2 position 24VDC @ 1.60 A VST-1410D 0-5000 180 690
P T
4-way, 2 position 115VAC @ .40 A VST-2210D 0-5000 180 690
t Inline check valve
PTBA
– – VD1P G 0-5000 0 690
99_121

PTBA
1)
Pressure drop from P-A or P-B at maximum oil flow of 690 in3/min.

140 ®
Solenoid spool valves, D03/CETOP3 VE-series
Shown: VEX-11 valve
D03 Direction Valve and Pressure: 0-5000 psi
accessories
product line
Collet-Lok®

Flow: 3-15 gpm


• D03 mounting pattern Voltage: 24 VDC
• Directional valves
E Electrovávulas
• Pilot operated check valve
• Dual flow control F Electrodistributeurs
Swing clamps

• Pressure reducing valve D Elektromagnetische Ventile

Options
VEW-11
D03 Manifolds
4.59 MB-series
Work supports

144 ▸
99_111

3.64
1.97

VE-series Fittings
Spool style solenoid valves and 3.02
control modules are used in 6.25 194 ▸
circuits that do not require zero
Important
Linear clamps

leakage. VET-11, VEX-11

Application 4.59 To hold the pressure in a


Used to control the advance clamping circuit, use the
and retract of single acting and VEX11 valve with the VD2P
3.64

double acting cylinders. The dual check module. Do not use D03
1.97

check valve can be used to lock spool valves with pressure


shutdown pumps.
Power sources

pressure in a group of cylinders. 3.23 3.02


The dual flow control offers 9.47
independent control of cylinder
advance and retract speeds. The
pressure reducing valve sets a VFC-4 VD2P PRV-6, PRV-7
circuit pressure lower than the
main pump pressure. 3.63 0.47
1.77 .33 1.18
1.67
Closed 0.64
Valves

4.88
Pin 8.00
2.02
0.05

Open 2.25
Spacer

Product selection
Valve flow path Solenoid Model Hydraulic Pressure Pressure Maximum
voltage number symbol range drop oil flow
50/60 hz

psi psi gpm


2-position/4 way 24 VDC VEW-11 A B
0-5000 125 8
1.32 Amps
z VEX-11 valve on ZW5020HG-
P T

FT21 pump.
3-position/4 way, 24 VDC VET-11 A B 0-5000 150 8
Closed center 1.32 Amps P T

3-position/4 way, 24 VDC VEX-11 A B 0-5000 165 8


Float center 1.32 Amps P P

Dual flow control – VFC-4 0-5000 – 10

A P T B

Dual pilot operated – VD2P 0-5000 200 15


check valve

A P T B
Pressure reducing valve – PRV-6 / 435-4350
– 3
PRV-7 75-2000

142 ®
VMM, VMT-serie Manual valves, D03/CETOP3
Shown: VMMD-001, VMTD-001
Pressure: 5000 psi Manual control of single and
double-acting cylinders
Flow: 1040 in3/min
• Near zero leakage pressure seal design
E Válvulas de control de 4 vias • 4-way, 3-position
F Distributeurs à 4 voies • Detented handle positions
D 4-Wege-Ventiler • Low handle effort 12 lbs, even at
full pressure

A B AB • Handle can be repositioned for side


by side valve mounting
P T PT • Compact size for directly mounting on fixture
for individual circuit control
• D03/CETOP 3 mounting pattern
Options

99_102
VD1P, Inline check valve
VMM and VMT-series
Manual directional control valves
◂ 140
for single- and double-acting
cylinder control. Lapped pressure
D03 Manifolds seal surface provide near
zero leakage.
144 ▸ The VMTD series has threaded
port connections and removable
Hoses and holding bracket for panel
couplers mounting.
192 ▸ Application
Panel mounting on fixtures for
Fittings control of individual circuits. The
blocked pressure port in the
center position allows demand
194 ▸ VMTD-001, 003 VMMD-001, -003 style pumps to stall out, saving
1.75
energy.
Important .28 1.59 The valves require check valves

Valves
for positive load holding.
For multiple circuit
applications, the VD1P inline
1.38

2.03

2.03

1.22

check valve is recommended


to prevent pressure drop on
2.00 .98 3.13
the holding circuit.

Pallet components
3.13 1.96
See page 145 for mounting
bolt information. 1.375-14UN
4.44

3.88
2.34

System components
Pressure on return side (tank)
.44

1.78

should not exceed 250 psi.


1.14

z Several VMTD-001 valves


.38

SAE #4
7/16"-20UN (4x) mounted on fixture waiting to be
#10-24UNC transferred to machine.
Product selection
Valve Mounting Oil Model Hydraulic Pressure Pressure Max.
Yellow pages

mounting bolts ports number symbol range drop 1) oil flow


pattern included

psi psi in3/min


t 4-way, 3-position control valves
AB
Panel mtg. – SAE #4 VMTD-001 0-5000 70 1040
D03/CETOP 3 #10-24un – VMMD-001 PT 0-5000 70 1040
A B
Panel mtg. - SAE #4 VMTD-003 0-5000 70 1040
99_122a

D03/CETOP 3 #10-24un – VMMD-003 P T 0-5000 70 1040


Pressure drop from P-A or P-B at maximum oil flow of 1040 in3/min.
1)

Seal material: Buna-N, Polyurethane.


www.enerpacwh.com ® 143
Solenoid modular valves Application & selection
Shown: VEC-15600D, VEC-15000B, VEK-15000B
Unmatched combination of possibilities
product line
Collet-Lok®

• Relief valve and pilot-operated check accessory valves are


stackable eliminating external plumbing
• Remote and pump mounting
• Mounting bolts included with each modular valve
Swing clamps
Work supports

Select the required valve flow path


Valve flow path For cylinder Valve Hydraulic
code symbol
99-137

VE-series
Linear clamps

Solenoid modular valves are especially well suited


for workholding and production applications. With t 2-way, 2-position (2/2)
11 possible flowpaths and 2 manifolds, for either Normally closed Unloading * VEH A

Enerpac’s submerged pump or a remote NPT P


mount, you can “custom build” a valve for B
Normally open Unloading * VEK
almost any application.
P

Application
Power sources

t 3-way, 2-position (3/2)


A
Ideal when mounted on remote manifold for Normally open Single-acting VEP
applications where independent control of P T
multiple cylinders is required. t 3-way, 3-position (3/3)
A
Tandem center Single-acting VEF
P T
A
Closed center Single-acting VEG
P T
Valves

t 4-way, 2-position (4/2)


A B
Crossover offset Double-acting VEE
P T
A B
Float offset Double-acting VEM
P T

t 4-way, 3-position (4/3)


A B
Open center Double-acting VEA
P T
A B
Closed center Double-acting VEB
P T
A B
Tandem center Double-acting VEC
P T
A B
Float center Double-acting VED
P T
* VEH and VEK valve models require the use of tank port for dump or unloading.

Product spefications
Pressure Maximum Voltage @ Hz Amperage draw
range oil flow

Amps
psi in3/min inrush holding
0-10,000 920 24 VDC @ 50/60 Hz – 2.5
0-10,000 920 115 VAC @ 60 Hz 3.6 1.0
0-10,000 920 220/240 VAC @ 50 Hz 1.3/1.4 .45/.53
0-10,000 920 230 VAC @ 60 Hz 1.8 .50 A
Note: Seal material: Buna-N, Polyurethane.
DIN43650 Valve plug included on remote mounted valves.
146 ®
Dimensions & options VE-series
Custom build your modular valves Pressure: 0-10,000 psi

▾ This is how a Solenoid Modular Valve Model Number is built up: Flow max.: 920 in3/min

Voltage: 24, 115, 230 V

VEA - 1 5 6 00 - D E Válvulas de control


F Electrodistributeurs
1 2 3 4 5
Valve Flow Flow Voltage Accessory Manifold
D Wegesitzventile
Path Capacity Valves

A AB

1 Modular valve code 4 Accessory valves PT PT

A = 4/3 Open center 000 = No accessory valves


B = 4/3 Closed center 100 = VS-11 Relief valve only
C = 4/3 Tandem center 150 = VS-11 Relief valve and Options
D = 4/3 Float center VS-51 3-way pilot operated
E = 4/2 Crossover offset check valve VEF/VEG only Gauges and
accessories
F = 3/3 Tandem center 160 = VS-11 Relief valve and
G = 3/3 Closed center VS-61 4-way pilot operated 190 ▸
H = 2/2 Normally closed check valve
K = 2/2 Normally open VEA/VEB/VEC/VED only Fittings
M = 4/2 Float offset 500 = VS-51 3-way pilot operated
P = 3/2 Normally open check valve VEF/VEG only 194 ▸
600 = VS-61 4-way pilot operated
2 Oil flow capacity
check valve
1 = 920 in3 per minute Accessory Valves
VEA/VEB/VEC/VED only
3 Solenoid voltage and Bolt Kits
5 Manifold
1 = 24 VDC, 50 / 60 Hz
A = No manifold Use VS-11 relief valve to add
2 = 230 V, 1 ph, 50 Hz
B = Remote mounted manifold system pressure control
5 = 115 V, 1 ph, 60 Hz
D = Pump mounted manifold to VE-series valves.
6 = 230 V, 1 ph, 60 Hz
VEA/VEC/VEF only
Use VS-51 3-way pilot

Valves
operated check valve to
convert 3-way VE-valve into
Example load-holding valve.

The VEA-15600-D is a modular valve Use VS-61 4-way pilot


with a 4-way, 3-position open center

Pallet components
operated check valve to
flowpath, 115 VAC, and an integrated convert 4-way VE-valve into
pilot-operated check valve, for load-holding valve.
mounting on an Enerpac pump.
To install accessory valves to
Bolt Kit BK-2 is included.
stack build modular valves
use bolt kits:

System components
BK-2 for 1 VS valve;
VE series Modular Valve Modular Valve BK-3 for 2 VS valves.
Pump Mounted Remote Mounted

Position 0 Relief Valve 3.50


Pressure drop vs oil flow
2.46 7.47 3.00
400
.279-.288 (4x)

T P
Diferential pressure drop (psi) u

P-A/B
Yellow pages

Tank port P-T


300
3/8"-18NPT
3.50
3.00

A/B-T
Gauge port
6.40 1)

1/4"-18NPT 2.09
200
A B
1.15

B A 1.12 T 3/8"-18NPT (4x) 100


.38 .75 3.50 1.98 .62
2.08 .38
1.75

3/8"-18NPT (2x)
1.00

3.48 5.39 0
0 1.0 2.0 3.0 4.0
1.75 Oil flow (gal/min) u
add 1.85 inch for each Accessory Valve.
1)

Note: BK-1 Bolt Kit is included with each modular valve.

www.enerpacwh.com ® 147
3-way directional manual control valves Application & selection
Shown: VM-2, VM-3
Reliable control of
single-acting cylinders
product line
Collet-Lok®

• Directional control valves provide advance/hold/retract


operation for use with single-acting cylinders
• Remote or pump mounting on most Enerpac pumps
• Return line kit included with remote valves
Swing clamps

• Available “locking” option on VC and VM-series


valves for load-holding applications
Work supports

Select the required center position


Non-locking Closed center
• Use in simple clamping • For multiple valve
99-138

circuits. Has interflow and cylinder operation.


V-series between ports All ports blocked in the
when shifted. center position.
Linear clamps

Manual operated 3-way, 2-position and 3-way,


3-position directional control valves for operation
of single-acting cylinders. Remote mount valves
Locking center Tandem center
include return line kit for connecting the valves
to pump reservoir. • For positive load holding • For one or multiple
without loss of pressure. cylinder operation. Pump
Application Cylinder travel can only flow is directed back to
Power sources

resume by shifting valve tank in the center position.


Pump mounted valves provide centralized control of
pump output for cylinder cycling. Remote mounted at from hold position.
any convenient point along the system where control
of cylinders is needed. Product selection
Valve type Valve Model Hydraulic
mounting number symbol
location
Valves

t Manual 3-way, 2-position (3/2)


– Pump VM-2
A

P T

t Manual 3-way, 3-position (3/3)


Tandem center Pump VM-3
z Four VC-15 Enerpac manual valves mounted A

on fixture to give independent control of several Tandem center Remote VC-3


hydraulic circuits. P T

t Manual 3-way, 3-position (3/3)


Tandem center, Pump VM-3L A

locking

Tandem center, Remote VC-3L


locking P T
Closed center Remote VC-15
A

P T

A
Closed center, Remote VC-15L
locking
99-123

P T

148 ®
Dimensions & options V-series
VM-2 Pressure: 0-10,000 psi
5.12 Flow max.: 1040 in3/min

E Vàlvulas de control
3/8"-18NPT
F Distributeurs à 3 voies
5.25

ø.34 (6x)
1.12 .62 D 3-Wege-Ventile

.81
1.44 1.88 1.12 A
.38 5.00 2.50 A
5.75 3.25
P T
PT

VM-3, VM-3L VC-3, VC-3L


VC-15, VC-15L
5.12 5.12

3/8"-

7.19 1)
7.25 1)

18NPT 5.69
5.75

1.58
1.50 1)
1)
1.50

.87

.75
Options
2.50 1.75 1.88 .69 1.38 Gauges and
3.00 3.00 accessories
3.56 5.00
.50 ø .34 (5x) 5.75 1/4"-20UN (2x) 4.49 1)
190 ▸
3/8"-18NPT
1)
VM-3L only 1)
VC-3L and VC-15L only
Hoses and
couplers
Product specifications 192 ▸
Model Pressure Used for Schematic flowpath
number range cylinder Fittings

Valves
Advance Hold Retract
psi lbs 194 ▸
t Manual 3-way, 2-position (3/2)
VM-2 0-10,000 Single-acting – 4.8
A A
Important

Pallet components
P P T

Locking Valves

t Manual 3-way, 3-position (3/3)


For applications that require
positive load holding, most
VM-3 0-10,000 Single-acting A 4.6
VM and VC valves are
P T available with pilot operated
VC-3 0-10,000 Single-acting 6.4 check valve. This option

System components
provides hydraulic locking of
t Manual 3-way, 3-position (3/3) the load until valve is shifted
VM-3L 0-10,000 Single-acting 8.6 into retract position.
A
To order this feature,
P T
place an “L” at the end
VC-3L 0-10,000 Single-acting 10.3 of the model number.
Yellow pages

VC-15 0-10,000 Single-acting A A A 6.4

P P P T

Valving help
VC-15L 0-10,000 Single-acting 10.3 See Basic System Set-up and
A A A
Valve information in
P P P T
our “Yellow Pages”.

197 ▸

www.enerpacwh.com ® 149
4-way directional manual control valves Application & selection
Shown: VC-20, VM-4
Reliable control of
double-acting cylinders
product line
Collet-Lok®

• Directional control valves provide advance/hold/


retract operation for use with double-acting or two
single-acting cylinders
• Remote or pump mounting on most Enerpac pumps
Swing clamps

• Return line kit included with remote valves


• Available “locking” option on VC and VM-series
valves for load-holding applications
Work supports

Select the required center position


Non-locking Closed center
99-139

• Use in simple clamping • For multiple valve and


V-series circuits. Has interflow cylinder operation. All
Linear clamps

Manual operated 4-way, 3-position directional control between ports when ports blocked in the
valves for operation of double-acting or two single-
shifted. center position.
acting cylinders. Remote mount valves include return
line kit for connecting the valves to pump reservoir.

Application Locking center Tandem center


Power sources

Pump mounted valves provide centralized control of • For positive load holding • For one or multiple cylinder
pump output for cylinder cycling. Remote mounted at without loss of pressure. operation. Pump flow is
any convenient point along the system where control Cylinder travel can only directed back to tank in
of cylinders is needed.
resume by shifting valve the center position.
from hold position.
Valves

Product selection
Valve type Valve Model Hydraulic
mounting number symbol
location

t Manual 4-way, 3-position (4/3)


Tandem center Pump VM-4
AB

z Enerpac VC-4 manual valves mounted to control Tandem center Remote VC-4 PT
hydraulic circuit on pallet fixture
Tandem center, Pump VM-4L A B

locking

Tandem center, Remote VC-4L


locking PT
Closed center Remote VC-20
A B

P T

Closed center, Remote VC-20L A B

locking
99-120

PT

150 ®
Dimensions & options V-series
Pressure: 0-10,000 psi

Flow max.: 1040 in3/min

E Vàlvulas de control
F Distributeurs à 4 voies
D 4-Wege-Ventile

A B
AB

PT
PT

VM-4, VM-4L VC-4, VC-3L


VC-20, VC-20L

5.12 3/8"-18NPT 5.12

Options
7.25 1)
5.75

Gauges and
7.19 1)

3/8"-
5.69

18NPT accessories
1.50 1)

1.50 1)

.87
190 ▸
1.58

.75 Hoses and


.50 2.50 1.75 1.88 .69 1.38 couplers
3.56 5.00 3.00 3.00
ø .34 (5x) 5.75 1/4"-20UNC (2x) 4.49 1) 192 ▸
1)
VM-4L only 1)
VC-4L and VC-20L only
Fittings

Valves
194 ▸

Product specifications
Important

Pallet components
Model Pressure Used for Schematic flowpath
number range cylinder
Locking Valves
For applications that require
psi Advance Hold Retract lbs positive load holding, most
t Manual 4-way, 3-position (4/3) VM and VC valves are
available with pilot operated
VM-4 0-10,000 Double-acting 4.6
check valve. This option

System components
provides hydraulic locking of
VC-4 0-10,000 Double-acting 6.4
the load until valve is shifted
into retract position.
VM-4L 0-10,000 Double-acting 8.6 To order this feature,
place an “L” at the end
of the model number.
VC-4L 0-10,000 Double-acting 10.3
Yellow pages

VC-20 0-10,000 Double-acting A A A 6.4


P T P T P T

B B
Valving help
B
See Basic System Set-up
VC-20L 0-10,000 Double-acting A A 10.3
A
and Valve information in
P T P T P T
our “Yellow Pages”.
B B B
197 ▸

www.enerpacwh.com ® 151
Accessory valves Application & selection
Shown: HV-1000A, V-17, V-10, V-12, V-152
Your hydraulic control solution
product line
Collet-Lok®

• Regulate oil flow or system pressure


• All valves feature NPT or SAE porting to
insure against leakage at rated pressure
• Can easily be installed in any system
• All valves are painted, coated or plated
Swing clamps

for corrosion resistance

Product selection
Valve type Maximum Model Oil
pressure number ports
Work supports

99-086

Accessory valves psi

Enerpac accessory valves are available in a wide Holding valve, air pilot 3000 HV-1000A 1/8" NPT
variety and many configurations to control hydraulic Holding valve, modular 3000 MHV-1 1/8" NPT
pressure or oil flow. These valves are used in Pressure limiting valve 3000 PLV-40013B 1/8" NPT
conjunction with other valves and system components
Linear clamps

Manual shut-off valve 5000 V-12 SAE #4


to provide full automation and control. Auto-damper valve 10,000 V-10 1/2" NPT

Application Safety check valve 10,000 V-17 3/8" NPT

Accessory valves are used to automate clamp cycles, Pressure relief valve 10,000 V-152 3/8" NPT
prevent pressure loss and provide additional operator
and component safety. Product specification
Power sources

HV-1000A
Air pilot holding valve P A
• Holds fluid under pressure
offering independent control
of different branches of the 4.34
same fixture 2.25
1/4"-18 NPT

• Valve can control the pilot


air and the booster in P
Valves

sequence
• Max. oil flow 305 in3/min 1/8"-
Air inlet
27NPT
• Works with the VA-42 four- .28
1.88
way air valve and a booster
A
2.00

1.00

MHV-1 P
Modular holding valve
A
z V-17 Safety check valve installed on a fixture. • Allows separate operation of clamping
fixtures with a single power source
• Ideal for applications
when fluid feed lines are 5.06
impractical. If system .75
.28
pressure is interrupted,
the MHV-1 will hold the
1.38
.92

pressure beyond the valve


1/8"-27NPT

• Max. oil flow 305 in3/min


• To release system pressure,
rotate valve handle in either
3.31

direction 90˚ to release and


A P
retract system pressure
1.38

1/8"- 27 NPT
1.38
99-122b

156 ®
Dimensions & options MHV, HV, PLV, V-series
Pressure: 0-10,000 psi
PLV-40013B 3.50 Flow max.: 305-1830 in3/min
Pressure limiting valve .68
A P
• Allows precise control of pressures E Válvulas de control
P
reaching specific clamps

1.50
F Valves de contrôle
• When pressure build-up reaches
a preset level, the valve closes, D Regelventile
stabilizing pressure to that section of the fixture Adjustable pressure screw

• Pressure adjustment between 200 to 1500 psi 1.63


P
• Max. oil flow 305 in3/min

.28
1.50
.75
P A

A
1/8"-27NPT (2x) 1.20

V-12
5.10
Manual shut-off valve
• Ball type valve can be used for the
master system shut-off or for isolating

2.31
separate circuits on a fixture
• Viton seals standard
• Straight through design for easy system
plumbing and installation 1.38
.49
.98 2.66
• Fully open allows high flow return of oil SAE #4 .437-20UNF
• Max. oil flow 732 in3/min

V-10 Auto-damper valve


1.50
• To protect gauge during high 1.12
cycle applications
• Creates a flow resistance when 1.12
load is released suddenly Options
No adjustments are necessary 4.69 VA-42
• Fits directly into GA-series gauge adaptor 1/2" -14NPT Air valve

Valves
158 ▸

Gauges
V-17 Safety check valve 4.00 and adaptors

Pallet components
• Ruggedly built to resist shock and
190 ▸
1.25

operate with low pressure drop


• Closes smoothly without 3/8" -18NPT
pounding Hoses
and couplers
• Max. oil flow 1830 in /min
3

192 ▸

System components
Fittings
V-152 Pressure relief valve
7.62 max
• Limits pressure developed by the ø 1.50 1.53 194 ▸
pump in hydraulic circuit, thus
3.12

limiting the force imposed on


other components
• 800-10,000 psi adjustment range;
Yellow pages

± 3% repeatability 4.53
3/8" -18NPT (3x)
Important
• Valve opens whenever preset
pressure is reached. To increase pressure setting, Valving help
turn handle clockwise
See Basic System Set-up
• Max. oil flow 1830 in3/min and Valve information in our
• Includes 3 ft. return line hose kit “Yellow Pages”.