Design Loading

ULS Ultimate Vertical load FEd 700 kN

Dimension / Sizes

Line of action from column face av 125 mm

Column / Beam b 400 mm

h 400 mm

Bearing Width bp 150 mm

Length Lp 300 mm

Gap 50 mm

Edge 50 mm

Corbel Width bc 250 mm

Depth hc 400 mm

Length Lc 400 mm

Eff. Depth d 363 mm

Concrete Cover c 30 mm

Bar Dia Main bar Φm 14 mm

Link ΦL 10 mm

Factors Reinforcement Concrete C35/40

αcc αct γc γs fyk fyd fck fcd

0.85 1.0 1.5 1.2 (N/mm2) (N/mm2) (N/mm2) (N/mm2)


450.0 391.3 35.0 19.83
Node Compression Strength σiRd, max = ki (v' /0.85) fcd v' = (1-fck/250) = 0.9

σ1Rd, max σ2Rd, max σ3Rd, max σ1Rd, max - Compressed Node

k1 = 1.00 k2 = 0.85 k3 = 0.75 σ2Rd, max - Node Tensioned (Compressed by anchor logs in a fixed dir)

20.07 17.06 15.05 σ3Rd, max - Node Tensioned (Compressed by anchor logs in diff dir)

Vertical Strut Width x1 = FEd / σ1Rd, max h 87 mm

Horz. Strut Width y1 = 0.2 d (z = 0.8 73 mm

Lever Arm z = 0.8 d 290 mm

∑M = 0 ==> FEd a = Fc z FT = Fc = FEd a / z a = av + x1/2 = 168.6 mm 406 kN

Node1 Verification σ1Ed = Fc / (h * 2y1) 7.00 N/mm2 < σ1Rd, max

OK!

As,req = FT / fyd 1039 2


Main Upper Reinf Required mm

Provided As,prov 8 H 14 1232 mm2 > OK!

Fdiag = Fc / cos θ = FEd / sin θ

Fwd =[{ 2 (z/a) - 1 } / { 3+ FEd / Fc }] Fc z= 290 mm a= 168.6 mm 210 kN

Secondary Upper Reinf. Required Asw,req = Fwd / fyd ≥ 0.25 As,prov = 307.88 mm2 538 mm2

Provided Asw,prov 5 H 10 2 Legs 785 mm2 > OK!

Node 2 Verification, Below the load plate σ2Ed = FEd / (bp * Lp) 15.6 mm2 < σ2Rd, max

OK!