UNIVERSAL INSPECTION CO. WILL.
EN 187 TAYE Soe
INSTRUMENT & EQUIPMENT CALIBRATION DIVISON
OF CALIBR
CERTIFICATE NO: UIC /QAT/4271
This certifies that the instrument below has been tested/calibrated using equipment traceable to
National / International standards or verified by Ratio type measurements using self-calibrating
techniques.
Information on the calibration process and the results are produced below and given in the
accompanying sheets of this document. All related traceable documents are on file at
UNIVERSAL INSPECTION CO. WILL, and may be examined on request
Customer FERNAS CONSTRUCTION CO
Address RAS LAFFAN, STATE OF QATAR
Description INVERTEC WELDING MACHINE
Manufacturer LINCOLN ELECTRIC
Model 300 TPX Report Date 24-Mar-21
Serial No. P1igosos614 Receipt Date 2 23-Mar-21
1D. No. N/A Calibration Date 2 23-Mar-21
Location RAS LAFFAN Calibration Due Date 22-Mar-22
‘The instrument was calibrated using the following reference, maintained at UIC Instrument &
Equipment Calibration division conforming to ISO 1702S requirements
Reference Standard Equipment Used
Description | _ Cert. No/Model Serial No
True RMS
ACD
111-20-42600018 42600018
Approved By
27,
Quality/ Lab Manager
‘The measurement results pertain only to the instrument calibrated. Page 1 of 2
‘This certificate andthe attached measurement result sheets shall not be reproduced except in full without the prior permission
Building No: 44, Unit No: A2, Zone : 86 OF Aikiaing 28
‘StNo: 205, Ain Khalid St, Salwa Road, Stato of Qatar i Uigiag she Sub ald oe ELE
TolFax : 4074 40300040 savecerteass ie
Esmail info@ui-ga.com UIC-QP-78-24 FO2, REVO ‘woneulga.comUNIVERSAL INSPECTION (0, WLL. Syd finial JLupaiigy Ast
CERTIFICATE NO: UIC /QAT/4271 Page Bote
customer. = FERNAS CONSTRUCTION CO
Address RAS LAFFAN, STATE OF QATAR
Description INVERTEC WELDING MACHINE Calibration Date 23-Mar-21]
Manufacturer LINCOLN ELECTRIC Calibration Due Date 22-Mar-22
Model 300 TPX Temperature 28.422°¢|
Serial No. P1180508614 Relative Humidi 47.8 25%
CALIBRATION TEST RESULTS FOR INVERTEC WELDING MACHINE
DC Current
Range UUT Setting ‘Master Reading Error % Error (FS)
(anc) a) (a) @ (a)
100.0 101.1 1.10 0.37
150.0 152.6 2.60 0.87
300.00
200.0 203.4 3.40 1.13
250.0 252.9 2.90 0.97
Power Source No-Load Voltage Accuracy Test:
“Measured Output Voltage (VDC)
Increasing Decreasing. Mean
57.0 56.2 56.60
Power Source Load Voltage Accuracy Test:
Function Tested UUT setting (V) Master Reading (V) Error % Error (FS)
24.00 24.04 0.044 0.138
Load Voltage
28.00 28.14 0.136 0.425)
General Information about the Calibration
The invertec Welding Machine has been Calibrated on the function of Voltage, and Current
Tolerance:
As per manufacturer's specification.
Reference Standards: [Other Tests:
1. BS 7570 Description Test Remarks
2. BS ENSO504 [Functional Checks:
Check Pass
Check Pass
calibrated By: e*)
Calibration Engineer
Approved by: 22,
Quality/ Lab Manager|