Download as pdf
Download as pdf
You are on page 1of 15
STENTO warine Communication P Hospital and Refrigerator Alarm System Type SCAS Technical & User Manual ‘STEENHANS SCAT fi Fev WHOL OT DB doe VINGTOR SYSTEM seas ‘Table of contents 1 General Description, 2'Technical description. 3, Installation procedures 4. Installation documents, 5. Operation instructions. BRUNE STENTO Marine Communication assumes no responsibility for any errors that may appear in its documentation, or damages arising from the information in it. No information in this manual should be regarded as a warranty made by STENTO Marine Communication ‘This manual may be updated without notice, Product names mentioned in this manual may be trademarks, They are used only for identification, So 1670 200109 Foe SYSTEM SCAS 1 General Description ‘This Marine Hospital and Reffigerator Alarm System, SCAS, is an alarm system that enables a person trapped in a reftigeration room or lying in a hospital bed to call for help from the bridge and/or galley. The system is designed to meet the classification society requirements = em co yo og oserrat | smut Sam ‘SCAR ww vov.0 2001.03.28 doe SYSTEM SCAS 2 Technical description 2.1 SCAS-1 Bridge Unit + indication lamps for power availability, hospital alarm and reffigeration alarm, buzzer for audible alarm push button to switch of the sound (max. 3 minutes). 24V DC input with fuse protection connection for extra signal device console or bulkhead mounted. 2.2 SCAS-2 Galley Unit ‘+ same configuration as SCAS 1 except 24V DC input. bulkhead mounting weather proof, * connection for extra signal device console or bulkhead mounted. 2.3 SCAS-3 Hospital Us ‘+ indication lamps for power availability and hospital alarm ‘indication lamps for power availability and hospital alarm. connection for 2 alarm activating bed switches. alarm reset push - button, + bulkhead mounting. «connection for signalling device (to be placed outside the room ) * connection possibilty for additional hospital unit 2.4 SCAS-4 Refrigeration Unit ‘indication lamps for power availability and refrigeration alarm. + alarm on/off push-button, ‘* connection for signalling device (to be placed outside the room ) © connection possibility for additional refrigeration unit weather proof IP 65. SCAR tw yev0 2001.03 28doo 2 SYSTEM SCAS 3. Installation procedures. 3.1 General For proper installation and operation of the SCAS-system we recommend reading this section thoroughly together with installation documents in chapter 4 Make sure that all mounting and cabling are correct before switehing on. 3.2 Installation SCAS-1,2,3,4 ‘The SCAS-1 can be flush or bulkhead mounted. ‘The SCAS-2, 3 and 4 for bulkhead mounting only ‘The units is equipped with screw terminals for cables max.2,Smmn? Make sure that itis sufficient space for cables and maintenance. 3.3 Installation of extra lamp. Have to be installed outside refrigerator rooms 3.4 Cable requirements Cables have to be min. 2 x 0,75mm? It is not specially requirements for screens. 3.5 Power supply requirements System power supply should be wired and fused independently from other systems 24 — 32V DC Current consumption max. 2A Current consumption depending on number of extemal alarm device. SCAS_tu rev. 2001.03.28 doe 3 SYSTEM SCAS 4. Operation instructions. 4.1 General ‘The Power must always be on, indicated with steady green LED. When an alarm is activated, a light on the panel will indicate, An extra lamp (optional) outside the actual room will also jcate, At the same time the alarm light on the galley and/or bridge unit will flash and buzzer will sound, Buzzer can be muted for 3 minuets, however the alarm can only be reset on the hospital or reftigeration room unit depending on which alarm that has been activated 4.2 SCAS-4 Refrigerator unit Activate the alarm by pressing the “ALARM ON/OFF” switch Indicated with red light flashing in the LED marked “ALARM” and steady light in extemal lamp , if installed Switch off the alarm by 2°nd pressing on the “ALARM ON/OFF” switch Indicating in SCAS-I and SCAS-2. ‘Flashing red light in the LED marked “REFRIG” together with @ tone signal from the buzzer, and steady sound or light in external alarm device. if installed. By pressing the switch marked "SOUND OFF" the buzzer will be muted for approx 3 minute. Note! The alarm can only be Switch off from the SCAS-4. 4.3 SCAS-3 Hospital unit Activate the alarm by pressing on the “BED-SWITCHES” Indicated with red light flashing in the LED marked “ALARM” and steady light in extemal lamp, if installed, ‘Switch off the alarm by pressing the switch marked “RESET Indicating / operation on SCAS-1 and SCAS-2. Flashing red light tn the LED marked “HOSPITAL.” together with a tone signal from the buzzer, and steady sound or light in external alarm device, if installed. By pressing the switch marked “SOUND OFF" the buzzer will be muted for approx 3 minute, Note! The alarm can only be Switch off from the SCAS-3. 5. Installation documents SCAS-1 : Data sheet Docnno.SCAS-1_ds SCAS-2 Data sheet Doe no, SCAS~ Data sheet ..-Doe.no.SCAS- Data sheet. Doc.no.SCAS-4 ds Data sheet... .-Doeno SON-16_ds Data sheet Doc no.A-851_ds Data sheet ..-Doe.no.SPS-2_ds SCAS system... Cable connection diagram Doc.no.SCAS cc ‘3GAS_w Fev.0 2001 03.28.doe 4 SCAS Hospital and Refrigerator System = 136 64, Marine oe Article No: SCAS1 Description: ‘Technical data: BRIDGE UNIT ~SCAS 1 Operation voltage: av + Indication amps for power aalabiliy, spt star and convection Serow eins shige ale: Mateca: ABS plastic Boze fora arm a : * Push button to switch of the sound (max. 3 minutes). Ere ark grey + 24V DC input with fuse protection IPrating a + Comecton forexa signa devie Dimension seo dg, above Weis 035% STEENHANS SERVOTEKNIKK VINGTOR SCAS Hospital and Refrigerator System Peay i 136 64 Marine > < > i x ©rown 3 © poser af © aerme 7 ¥ Ee ¥ 3x PG13,5 Article No: SCAS2 Deseription: GALLEY UNIT-SCAS 2 + Indication lamps for power availability, hospital alarm and ‘efigeration alarm, Buzzer foradibleslarm Pash button fo switch ofthe sound! (max. 3 mines), 24V DC input with fuse protection Connection for extra signal device, Bulkhead mounted. Weatherproof STEENHANS ‘Technical data: ‘Operation voltage: Connections: Material Colour: P ating: Dimensions: Weight i Hl rave Screw terminals ABS plastic Dark grey e455 see dg, above 035ke -}+-Siemtuni Cam SEAS Comm 19 SCASH SERVOTEKNIKK Cae a SCASY VINGTOR SCAS Hospital and Refrigerator system mai wee BIS -Se K 64 >» Marine -SCAS9— a | © roves a | | © manos | Article No: SCAS3 Description: ‘Technical data: HOSPITAL UNIT-SCAS 3 ‘Connections: Serew tereninals ‘+ Indication lamps for power availability and hospital alarm Matera: ABS plastic ‘+ Indication lamps for power availability and hospital alarm, ie Duk gry + Conneton for 2 alae ativan bed swic, pa a + Connection possitilty for additional hospital unit + laren reset push-button einbuubaeteseebia Ascii + Bulkhead mounting Weight: 035k, STEENHANS SERVOTEKNIKK VINGTOR SCAS Hospital and Refrigerator System fees 64 Marine Kiem K > 1 Orowen : ) g | ssn | | | @ | | op SEES ete ee GDR OD ~ ED 3x PG13,5 Article No: SCAS4 Description: Technical data: REFRIGERATION UNIT—SCAS4 Connections: Screw terminals + Indeatonlanp focpoveravabity andreigerton slam, Maes ABS plastic Alam ont push-tuton toate + Comet sigan debe rnsone yg '* Connection possibility for additional refrigeration unit. Dimensions: see dwg, above & Weather poot Weigh: 038% + Bulkhead mounting STEENHANS SERVOTEKNIKK VINGTOR Signal Units Marine Article No: SON-16 Description: ‘Technical data: “The Combined Sounder & Flashalarm type SON 16 isa combined Manufactorr: Bs szudibleand visual warning device which is wel suited for fire and ‘Type/art.no SONFLIOL security purposes incorporating high sound output, low current Operation vot 24vDC consumption, high quality and simple installation, I offers many Curent 2agma features that makes the sounder unique including 10 Field Sound output: 954B(4), Im, 24VDC programmable tones one of which is ist in sounder technology Flash energy: 5 Joules (Ws) an lectrone simulated bel, reverse polarity protection and Flash frequency 60 fashes/nin automatic synchronisation. ‘Volume conto: 2508 Rating 100% * High sound output eae pete Pee erating temp. AS*Cr0455°C + Low curent consumption Humility: 0.90% 950 Protection: ss 10 Alarm tones including bell sound. + Atomic anchroniston Cac 220 Qoskow) +2 stage of aor Housing: “Tasalan FRABS * Complies with European norms for fre Mousing colour: ed Lense colours: yellow-red-amber-bhue- * Small and compact housing eee preen-clear and white Dimensions: see drawing, Weight 0.510kg TERMINALS STEENHANS SERVOTEKNIKK VINGTOR Signal Units Marine Mount.holes: 4mm Article No: A-851 Deseription: ‘Technical data A$s1 Manufacturer: Werma + signal light forall systems Typelart.n. asi = to be wall mounted in noisy areas ete Operation volt 2avDC Current 300mA Rating: 100% Operating temp. 30°C 140°C Humidity: max, 90% Protection: IPs Cable entry 5-7 mm rabber gland Housing: ABS. Housing colour Red Lense colours red-blue-orange green-clear Dimensions: see drawing Weight 80g STEENHANS SERVOTEKNIKK VINGTOR Power Supply stento Marine | | | Gel | | get gf || 1 th | pl | Zt 1 i | Heer eee eee Article No: SPS-2 Description: Technical data: SPS-2 Anput data: + Power supply 115/230 VAC to 24VDC 2A with autoswitch, Input voltage AC: 90-264 VAC relay when failure on main supply Frequency: 30-60Hz, " InpatvologeDC: 24D Powe es 2.8 tou 1_[}118/230 vAcin Fuse (located in module): 2 AT el 2F ome Inrash current <20A a Input current with : tutpu sho cei: <02A g| Ourpur ‘Ourput voltage: Voltage when failure ‘on main supply’ Max. output curent PuseF2: Loud regulation Ripple: Hold op time: Over current and short citeuit protection: STEENHANS SERVOTEKNIKK DADC Adj.45% 24vDe 2A 25AT 50msat230 VAC S10msat 115 VAC “ticeup” with automatic recovery VINGTOR 2, JUNSNSEEEEEEEETEET BRIDGE LAMP: PREP ly @ yy] t TTT [2x0.75 uvocw 200] [J LL TOTS SCASZ GALLEY LAMP LAMP / HOOTER 2x0,75 THIET | a] ee lepalaya VYPETEOTTTyyy a Jt 13 JI1) 2200.15 J J J 24240.75, 1 i Pete SWITCH 1 SWITCH? | LAMP OUTSIDE ROOM HOSPITAL \ ' \ 3 \ | Vit ' \ | aonitionar Jad 1 BOE Seas] nos} | 1 SST I REFRIGERATOR | LAMP OUTSIDE ROOM i TERT ! 1 Ty 1 I een NY FatiO75 NOTE! ' OPTION: EXTRA SIGNAL DEVICE A-851 ALARM LIGHT ORANGE 24V DC SON-16 COMBINED HOOTER/FLASH ALARM ORANGE 24V 0C SWITCH 1 - 2 FOR BED. STANOARD DELIVERY ‘SPS-2 RECOMMENDED POWERSUPPLY USE CABLE MIN 0,75¥M [DESIGN AND SPECICATION ARE SUBIECT TO CHANGE WITHOUT NOTICE] STENTO Marine Comerunteation |STEENHANS VINGTOR| HOSPITAL AND REFRIGATOR [DRAWNBY: 20010372 Sen, COMMUNICATION SYSTEM Type SCAS Cable connection diagram _ce rev.0 ney. [By [pate STENTO Marine Communication SPAREPART. For SCAS-1 SCAS-2 SCAS-3 SCAS-4 Recommended spare part kit, Part No. SCASS Parts No. ‘Description Parts Code ‘Switch for alarm reset LED, red LED, green Buzzer Switch bed t Fuse SAT Available Spare parts Part No. Deseription Parts Code, PSCAS-1 PCB for scas-1 PSCAS-2 PCB for seas-2, PSCAS-3 PCB for scas-3 PSCAS-4 PCB for scas-4 Dono. CTE pl Rev. O Date 2001.02.09 Prepared by Sen Page Tof 1

You might also like