Notes:-: Timber Doors Key Plan

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

NOTES :-

A A

B B

6 7 8 9 10 11 12 12a 13 14 15 16 17 18 19 20 20a 21 LEGEND :-


7000 7000 3500 3500 3500 7000 3500 3500 7000 7000 7000 7000 3500 3500 7000 1000 2700

H
1200

Gb

C C
7000

Ga
2200

MJ MJ MJ

STR-02-04
4800

ADMINISTRATION AHU ROOM


D SECTION
3RD-02-02 O/R TOILET MALE O/R TOILET FEMALE
LFT-02-05 D
3RD-02-01
MJ +38.250(MSL) 3RD-02-04 3RD-02-05
+38.250(MSL) FFL.
FFL.
Fd

31-D01 LIFT LOBBY


3RD-02 JAN.ROOM DISABLE
DRAUGHT TOILET DRAUGHT 3RD-02-09
3500

LOBBY 3RD-02-08 3RD-02-07 LOBBY DN UP

3RD-02-03 3RD-02-06
09-D01
14-D09 10-D01
3RD-02 BLOCK 5C
14-D11 14-D10 3RD-02 3RD-02 3RD-02-10
3RD-02 3RD-02
Fc ZONE 4C ZONE 4D ZONE 6C ZONE 6D
MJ

BLOCK 5B
CORRIDOR
CORRIDOR 3RD-02-11
14-D08
4000

14-D12 3RD-02-14 3RD-02 +38.250(MSL) ZONE 4B ZONE 4A ZONE 6B ZONE 6A


3RD-02

+38.250(MSL) FFL.
FFL. BLOCK 5A

Fb PANTRY ZONE 9B
3RD-02-12 ZONE 3C ZONE 3D ZONE 7C ZONE 7D

E E
3500

ZONE 9A
ZONE 3B ZONE 3A ZONE 7B ZONE 7A
3RD-02-13
UP
STR-02-03
Fa ZONE 1B ZONE 1C

DN ZONE 2B ZONE 2A ZONE 8B ZONE 8A

ADMINISTRATION 13-D01
3500

3RD-02
SECTION
ADMINISTRATION 3RD-02-32
SECTION ZONE 1A
14-D13 14-D15 +38.250(MSL) 14-D07
3RD-02-31 3RD-02 3RD-02 FFL. 3RD-02
16-D02
F +38.250(MSL) 3RD-02
LIFT LOBBY ADMINISTRATION
FFL.
3RD-02-14a SECTION
3RD-02-16
+38.250(MSL)
KEY PLAN
3500

FFL.

CORRIDOR SPRINKLER
3RD-02-14 ROOM LFT-02-04
LFT-02-03
Ea 3RD-02-33
14-D06
3RD-02
3500

F IT ROOM F
3RD-02-15
+38.250(MSL)
14-D05 Rev. Date Desd. Description Drwn. Chk'd App'd
3RD-02
FFL.
E This drawing was prepared by CECB based on Architectural design drawings prepared by M/s Muditha Jayakody Associates Pvt.
17a-D01
3RD-02 Ltd, who was the Main Consultant/Architectural Consultant for Defence Headquarters Complex Project, Akuregoda till 30.09.2016.
CORRIDOR CORRIDOR TOILET REST ROOM Client DEMOCRATIC SOCIALIST REPUBLIC OF SRI LANKA
4000

14-D01 3RD-02-14 3RD-02-14 16-D01


3RD-02 3RD-02 3RD-02-17 3RD-02-17a
+38.250(MSL) MINISTRY OF DEFENCE
FFL.
MJ 25-D01
3RD-02
M
Project
Dd
DEFENCE HEADQUARTERS COMPLEX - AKUREGODA
14-D03
14-D02 3RD-02
29-D01 TOILET 3RD-02
3RD-02
1300

3RD-02-30 28-D01
3RD-02 DRAUGHT DRAUGHT
3RD-02-26 LOBBY LOBBY
VIP
Dc LIFT LOBBY
LFT-02-01 26-D01
3RD-02 3RD-02-22
3RD-02-20 Project Management & Procurement
LIFT
INVESTIGATION AREA
3RD-02-29
3RD-02-28 LOBBY DN
UP DISABLE PROJECT MANAGEMENT UNIT OF THE ARMED FORCES
2200

3RD-02-25 JAN.
TOILET
+38.250(MSL) ROOM OFFICER
FFL. OFFICER 3RD-02-21 3RD-02-21a TOILET MALE
TOILET FEMALE Architectural Consultant (with effect from 01-10-2016)
Db 3RD-02-19
MJ 3RD-02-23
1300

AHU ROOM
DEFENCE COORDINATING
SECTION
CENTRAL ENGINEERING CONSULTANCY BUREAU
Da ELECTRICAL
G PANEL ROOM 3RD-02-27 LFT-02-02 3RD-02-24
G
& +38.250(MSL)
+38.250(MSL) Engineering , Quantity Surveying & Construction Management
UPS ROOM FFL.
FFL.
3500

STR-02-02 ANCILLERY ROOM CENTRAL ENGINEERING CONSULTANCY BUREAU


3RD-02-18
415, Bauddhaloka Mawatha, Colombo 07.
D
MJ TEL : 0112668800 FAX: 0112687369

MJ MJ Construction by
CONSTRUCTION MANAGEMENT UNIT OF THE ARMED FORCES
3500

Drawing Title
MAIN BUILDING
Cb BLOCK 02 - THIRD FLOOR
TIMBER DOORS
KEY PLAN
Designed Recommended
YGAD ...............................................
CONSULTANT ARCHITECT / SENIOR ARCHITECT
Drawn KKD
H Approved H
........................................
Checked THA DGM (Architectural)
Submitted Scale Date Status
TGRS NTS 17.12.2020
CAD File P:\02_Bldgs\01_MB\MB_AR\ARPrint\TI\DETAILS\TIMBER DOORS\Block 2\LAYOUTS TEN
Sheet Size Drawing No. Rev. No.
This drawing is sole property of CECB. Data contained on this drawing shall not to be used, reproduced, duplicated in whole or part without the prior permission of CECB. CECB shall A1 DHQC-CECB-MB-TI-AR-DW-3F-02-80707 -
not be held responsible for the unauthorized use of this drawing on Projects other than for which it was used.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 23 December 2020

You might also like