Professional Documents
Culture Documents
Field Guide CCW
Field Guide CCW
WATERPROOFING
Field Guide
800.527.7092 | www.carlisleccw.com
in
1 2 3 4 5 6 7 8
Table of Contents
Waterproofing Membranes and Accessories ...............................................1
Frequently Asked Questions ...............................................................................9
CCW-500R ................................................................................................................11
Vapor-Lock .............................................................................................................. 34
MiraSEAL ................................................................................................................. 53
CCW-525................................................................................................................... 79
MiraDRI 860/861.................................................................................................. 107
MiraCLAY ............................................................................................................... 143
Barricoat-S/R ....................................................................................................... 186
MiraDRAIN .............................................................................................................206
Tie-Back Covers .................................................................................................. 240
Technical Bulletins ............................................................................................. 242
I
Waterproofing Membranes and Accessories
Product Name Description Packaging Coverage Rate
1
Farenheit; horizontal and vertical
applications
Waterproofing Membranes and Accessories
Product Name Description Packaging Coverage Rate
CCW Waterproofing Membranes (continued)
CCW MiraCLAY Standard sodium bentonite clay 5' x 14' roll 70 sq. ft./roll
formulation. A site specific water sample
is required to determine which specific
Miraclay Formulation will be required.
CCW MiraCLAY EF Enhanced Sodium Bentonite Formulation 5' x 14' roll 70 sq. ft./roll
for uses near saltwater, chemically
contaminated sites, or foreign
substances. A site water sample is
required to determine which specific
Miraclay Formulation will be required.
CCW MiraCLAY GM Enhanced Sodium Bentonite Formulation 5' x 14' roll 70 sq. ft./roll
sandwiched between a non-woven
geotextile and a slit film woven
geotextile; needle punched; HDPE Film
applied to woven surface. A site specific
water sample is required to determine
which specific Miraclay Formulation will
be required.
CCW Barricoat-R Roller Grade, Water-Based asphalt 5 gallon pails 60 mil - 16.75 sq. ft./gallon
emulsion for below grade vertical
surfaces
2
Waterproofing Membranes and Accessories
Product Name Description Packaging Coverage Rate
3
Waterproofing Membranes and Accessories
Product Name Description Packaging Coverage Rate
Auxilliary Membranes (continued)
CCW Liquideck Solvent-free, two-component 4 gallon kit 60-mil - 25 sq. ft./gallon
polyurethane compound for preparing
and leveling rough concrete surfaces
prior to CCW MiraDRI 860/861 horizontal
applications.
CCW Contact Adhesives
CCW-702 Use with all CCW Sheet Waterproofing & 5 gallon pails 300-350 sq. ft./gallon; varies with substrate
AVB Systems
CCW-702LV Use with all CCW Sheet Waterproofing & 5 gallon pails 300-350 sq. ft./gallon; varies with substrate
AVB Systems
CCW-702WB Use with all CCW Sheet Waterproofing & 5 gallon pails 200-350 sq. ft./gallon; varies with substrate
AVB Systems
CCW-715 Use with CCW MiraDRI 860/861 as 5 gallon pails 300-350 sq. ft./gallon; varies with substrate
Green Concrete Contact Adhesive
CCW-AWP Use with CCW MiraDRI 860/861, CCW 1 gallon pails; 5 gallon pails 400 sq. ft./gallon; varies with substrate
Vapor-Lock, and CCW-500R
CCW-550 Primer Use with CCW 500 System 5 gallon pails 500 sq. ft./gallon; varies with substrate
CCW CAV-GRIP Use with all CCW Sheet Waterproofing & # 40 Cylinder 2,000-2,200 sq. ft./cylinder
AVB Systems
4
Waterproofing Membranes and Accessories
Product Name Description Packaging Coverage Rate
5
40" x 200' 667 sq ft./roll
150" x 200' 2500 sq. ft./roll
Waterproofing Membranes and Accessories
Product Name Description Packaging Coverage Rate
CCW Drainage Composites
CCW MiraDRAIN 2000 Intermediate-flow, low compressive- 4' x 50' rolls 200 sq. ft. roll
strength, shallow depths not exceeding
10 feet of depth
CCW MiraDRAIN 6000 high-flow, high-compressive strength 4' x 50' rolls 200 sq. ft. roll
CCW MiraDRAIN 6200 high-flow, high-compressive strength, 4' x 50' rolls 200 sq. ft. roll
Polymeric Sheet - prevents die-cutting of
waterproofing membrane
CCW MiraDRAIN 8000-P chemical resistant, high-performance, 4' x 50' rolls 200 sq. ft. roll
high-strength
CCW MiraDRAIN 9000 high-performance, high-strength 4' x 50' rolls 200 sq. ft. roll
CCW MiraDRAIN 9800 high-performance, high-strength 4' x 50' rolls 200 sq. ft. roll
CCW MiraDRAIN 9900 high-performance, very high- 4' x 50' rolls 200 sq. ft. roll
compressive strength
CCW MiraDRAIN HC high-flow, foundation or edge drain 6" x 100' rolls 50 sq. ft. roll
12" x 100' rolls 100 sq. ft. roll
24" x 100' rolls 200 sq. ft. roll
48" x 100' rolls 400 sq. ft. roll
6
Waterproofing Membranes and Accessories
Product Name Description Packaging Coverage Rate
7
Waterproofing Membranes and Accessories
Product Name Description Packaging Coverage Rate
CCW Sheet Flashings
CCW 711-90 Flashing 90-mil, high-strength, heat resistant 12" x 45' (2 rolls/carton) 45 sq. ft./roll
woven polypropylene mesh, self- 18" x 45' (1 roll/carton) 67.5 sq. ft./roll
adhering sheet flashing for application 24" x 45' (1 roll/carton 90 sq. ft./roll
in the CCW 500R Hot Applied 36" x 45' (1 roll/carton) 135 sq. ft./roll
Waterproofing System
CCW Uncured Neoprene Uncured Neoprene Flashing for use 12" x 100' Roll (1 roll/carton) 100 sq. ft./roll
Flashing within CCW 500R Hot Applied 18" x 100' Roll (1 roll/carton) 150 sq. ft./roll
Waterprofing or CCW 525 Waterproofing
Systems.
Termination Bar
Sure-Seal Termination Bar Extruded Aluminum Termination Bar 1" x 10' (50 pcs; 500 lf per Carton)
CCW Tie-Back Cover
CCW Tie-Back Cover (Square) Preformed, high-impact resistant, ABS 6" x 14-½" x 9" rectangle
plastic Rectangle
8
Frequently Asked Questions
What is the best way to contact you?
CCW technical services professionals may be contacted by email:
technicalservices@carlisleccw.com or 888-229-2199
CCW customer service professionals may be contacted by email:
customerservice@carlisleccw.com or phone: 888-229-0199
9
Frequently Asked Questions
What is the allowed moisture content in specific substrates?
Use the material manufacturers’ recommendations for the specified allowable moisture
content for their products. Here are some general guidelines for specific substrates:
• Wood Based Sheathings (plywood, OSB)- shall be at a maximum 19% moisture
content
• Exterior Gypsum Sheathing- 1% or less
• Concrete and CMU- 5-12% or less
10
CCW-500R Hot-Applied Waterproofing System
Table of Contents
Description ...............................................................................................................12
Installation Guidelines .........................................................................................12
Limitations ................................................................................................................12
Accessories..............................................................................................................12
Coordination ............................................................................................................13
Substrate...................................................................................................................13
Delivery, Storage, and Handling.......................................................................13
Application ...............................................................................................................13
Crack Treatment Installation Instructions ...................................................15
500-1 – Crack Treatment ............................................................................. 15
Expansion Joint Installation Instructions ....................................................16
500-3A – Expansion Joints Less Than ½" ................................................... 16
500-3B – Perimeter Expansion Joint ........................................................... 17
500-3D – CCW-EJ-500 Expansion Joint...................................................... 18
500-3H – CCW-EJ-500 Perimeter Expansion Joint ...................................... 19
Curb & Parapet Flashing Installation Instructions................................... 20
500-4A.1 – Option 1: Exposed Curb & Parapet Flashing
with CCW-703V Liquiseal ............................................................................. 20
500-4A.2 – Option 2: Exposed Curb & Parapet Flashing with SecurTAPE .... 21
500-4B – Non-Exposed Curb & Parapet ...................................................... 22
Double Drain Installation Instructions ......................................................... 23
500-6 – Double Drain .................................................................................. 23
Pipe & Penetration Flashing Installation Instructions ............................ 24
500-8A – Pipe and Penetration Flashing ...................................................... 24
500-8C – Small Penetrations ....................................................................... 25
Vertical Termination Installation Instructions ........................................... 26
500-9D – Vertical Termination Mechanical .................................................. 26
Plaza Deck Installation Instructions ............................................................. 27
500-10A – Insulated Plaza Deck .................................................................. 27
500-10B – Paver Plaza Deck ....................................................................... 28
500-10E – Concrete Topping Slab ................................................................ 29
Corner Reinforcement Installation Instructions....................................... 30
500-15A – Inside/Outside Corner Reinforcement ......................................... 30
500-15B – Outside Corner Reinforcement.................................................... 30
500R to Existing 500R Lap Tie-in Installation Instructions ...................31
500-15C – 500R Lap onto Existing 500R ..................................................... 31
Overflow Metal Scupper Installation Instructions ................................... 32
500-18A – Option 1: Overflow Metal Scupper .............................................. 32
500-18B – Option 2: Overflow Metal Scupper .............................................. 33
11
CCW-500R Hot-Applied Waterproofing System
DESCRIPTION
CCW-500 Hot-Applied Waterproofing Membrane is a single-component, rubberized
asphalt compound that forms a tough, flexible, thick waterproofing membrane. CCW-
500 is comprised of 26% pre-consumer material and can contribute toward LEED®
credits in new construction. CCW-500 adheres tenaciously to virtually any sound
vertical or horizontal surface, to ensure water will not migrate beneath the membrane
in the event of physical damage. The fast setup time speeds the completion of the
waterproofing. CCW-500 Hot-Applied Liquid Membrane is applied in a thick, monolithic
coating utilizing CCW Reinforcing Fabric, which allows for a wide variety of substrate
conditions. CCW-500 is used for waterproofing split-slab construction projects and is
especially suited as the waterproofing membrane on roof decks using the inverted roof
membrane assemblies and green roof systems.
INSTALLATION GUIDELINES
This application guide has been assembled to assist in the application of CCW 500R
and is intended to offer guidance to the construction community. It is intended to be
used in conjunction with current CCW published literature. Other acceptable methods
of application may be incorporated during construction that are not depicted in this
guide provided all applications follow proven and sound construction techniques.
LIMITATIONS
• Do not use on exposed or wearing surfaces.
• Not recommended over lightweight insulated concrete.
• If metal pan is used for concrete form, the vented metal pan is preferred.
• Consult with Carlisle’s representative before using CCW-500 on any type of
lightweight concrete, concrete with curing compounds or additives or decks that
have existing waterproofing materials.
• Do not apply below 0°F or to damp, frosty or contaminated surfaces.
ACCESSORIES
• CCW-500 Reinforcing Fabric
• CCW 300HV
• CCW Protection Board H
• CCW Protection Board HS
• CCW 550 Primer
• CCW-AWP Contact Adhesive
• CCW-702LV Contact Adhesive
• CCW-702 Contact Adhesive
• CCW-EJ-500
• CCW-711-90
• CCW Uncured Neoprene Flashing
• CCW MiraDRAIN Drainage Composite
• CCW-201 Sealant
12
CCW-500R Hot-Applied Waterproofing System
COORDINATION
• Pre-construction meeting shall cover all decisions pertaining to design of
waterproofing membrane to achieve a continuous, water-tight building structure.
• Review submittals, surface preparation, installation procedures, special details,
sequence of construction, responsibilities, mock-up requirements, inspection,
testing, protection of membrane, and repair procedures.
• Mock-up shall establish procedures and workmanship that must be maintained
during installation.
• Review adjacent materials such as drains, doors, parapets, penetrations, and
other site conditions for conformance to manufacturer’s application instructions.
SUBSTRATE
• Ensure all surfaces are installed in accordance with manufacturer specifications.
For concrete, ensure the deck has a finish of an International Concrete
Restoration Institute (ICRI) Concrete Surface Preparation of a CSP 2-5.
• Substrate shall be dry, clean, sound, and free of dust, dirt, residue and all other
surface contaminants.
• Verify substrate is flat, free of fins and planar irregularities.
• Substrate systems and the structural performance thereof shall be engineered by
others.
• Prevent the accumulation of water infiltration behind the substrate.
• Unsatisfactory conditions shall be reported and corrected prior to application of
CCW materials.
• Please refer to the CCW Vapor Lock System for applications over light-weight
concrete or wood substrates.
DELIVERY, STORAGE AND HANDLING
• Deliver CCW materials in original unopened packages.
• Protect CCW materials during transportation, storage, and installation to avoid
physical damage.
• Store CCW materials in a cool dry area protected from direct sunlight and
extreme heat.
APPLICATION
Surface Preparation: New concrete shall be water cured, with a light, broom finish,
and in place for 14 days minimum, 21 days preferred. Surface shall be structurally
sound, dry, and free of dust, dirt, frost, laitance, non-approved curing agent and
other contamination that may affect adhesion of the membrane.
Remove splatters, fins, ridges or other projections to provide a level surface. Fill
holes, honeycombs, rock pockets, spalls or other voids and indentations with
approved concrete patching compound. Grind or fill surface at cold joints where each
pour is at a different plane to provide a smooth and level surface.
Detail Work: Mix CCW-201 Sealant and apply per Carlisle standard details. Allow
the sealant to cure overnight. Detail expansion joints and drains per manufacturer’s
recommendation.
13
CCW-500R Hot-Applied Waterproofing System
Apply a thin, even coat of any CCW recommended primer or contact adhesive, 6"
wide, centered over all non-moving cracks less than 1/16" wide and cold joints. Apply
primer at published coverage rate per gallon. Allow primer to dry. Apply a 125-mil-
thickness coat of CCW-500 Hot-Applied Liquid Membrane over the primed crack or
cold joint.
Apply a thin, even coat of any CCW recommended primer or contact adhesive,
16" wide, centered over all cracks greater than 1/16" wide, all moving cracks and all
previously sealed expansion joints. Allow primer to dry. Apply 90 mils of CCW-500
membrane to cover primed areas. Install a 12"-wide strip of CCW-711-90 Sheet
Membrane Flashing, centered over the cracks and control joints.
Application: Blocks of CCW-500 shall be melted in a twin wall kettle with
continuous agitation. (Air Jacketed or Oil Jacketed Kettle can be used).
Caution: Do not exceed maximum safe operating temperature of 375°F (for best
results, use at 350°F).
Apply a thin, even coat of any CCW recommended primer or contact adhesive to
the entire surface to receive waterproofing. At the juncture of all vertical sections
with the deck surface, such as parapet walls, columns and all projections through
the deck, apply a thin, even coat of CCW primer or contact adhesive on the vertical
section to the height indicated on the drawings (8" minimum recommended). Apply
primer at published coverage rate per gallon. Allow the primer or contact adhesive to
fully dry. Note: Membrane will not properly adhere to wet primer.
Penetrations and flashings shall be detailed per manufacturer’s published
drawings. Apply CCW-500 Hot-Applied Membrane to the primed/prepared vertical
and horizontal surfaces, including all previously detailed areas. For vertical wall
applications of 180 mils, install two coats of CCW-500 with each coat being applied
to achieve 90 mils per coat. While to first coat is still warm and tacky, install CCW-
500 Reinforcing Fabric and then apply second coat of CCW-500. For horizontal
applications of 215 mils, install two coats of CCW-500 with the first coating being
applied to achieve 90 mils and the second coat being applied to achieve 125 mils.
While the first coat is still warm and tacky, install CCW-500 Reinforcing Fabric and
then apply second coat of CCW-500.
14
CCW-500R Detail
Crack Treatment (500-1)
15
CCW-500R Detail
Expansion Joints Less Than ½" (500-3A)
16
CCW-500R Detail
Perimeter Expansion Joint (500-3B)
17
CCW-500R Detail
CCW-EJ-500 Expansion Joint (500-3D)
18
CCW-500R Detail
CCW-EJ-500 Perimeter Expansion Joint (500-3H)
19
CCW-500R Detail
Option 1: Exposed Curb & Parapet Flashing
with CCW-703V Liquiseal (500-4A.1)
20
CCW-500R Detail
Option 2: Exposed Curb & Parapet Flashing with SecurTAPE (500-4A.2)
21
CCW-500R Detail
Non-Exposed Curb & Parapet (500-4B)
22
CCW-500R Detail
Double Drain Detail (500-6)
23
CCW-500R Detail
Pipe and Penetration Flashing (500-8A)
24
CCW-500R Detail
Small Penetrations (500-8C)
25
CCW-500R Detail
Vertical Termination Mechanical (500-9D)
26
CCW-500R Detail
Insulated Plaza Deck (500-10A)
27
CCW-500R Detail
Paver Plaza Deck (500-10B)
28
CCW-500R Detail
Concrete Topping Slab (500-10E)
29
CCW-500R Detail
Inside/Outside Corner Reinforcement Details (500-15A, 500-15B )
30
CCW-500R Detail
500R Lap onto Existing 500R (500-15C)
31
CCW-500R Detail
Option 1: Overflow Metal Scupper (500-18A)
32
CCW-500R Detail
Option 2: Overflow Metal Scupper (500-18B)
33
Vapor-Lock Hot-Applied Waterproofing System
(For Applications over Light-Weight Concrete or Wood Substrates)
Table of Contents
Description .............................................................................................................. 35
Installation Guidelines ........................................................................................ 35
Limitations ............................................................................................................... 35
Accessories............................................................................................................. 35
Installation Guidelines ........................................................................................ 36
Coordination ........................................................................................................... 36
Substrate.................................................................................................................. 36
Delivery, Storage, and Handling...................................................................... 36
Application .............................................................................................................. 37
Crack Treatment Installation Instructions .................................................. 39
VL-500-1 – Crack Treatment ........................................................................ 39
Expansion Joint Installation Instructions ................................................... 40
VL-500-3A – Expansion Joints Less Than ½” .............................................. 40
VL-500-3B – Perimeter Expansion Joint ...................................................... 41
VL-500-3D – CCW-EJ-500 Expansion Joint................................................. 42
Curb & Parapet Flashing Installation Instructions................................... 43
VL-500-4A – Non-Exposed Curb & Parapet ................................................. 43
VL-500-4B – Exposed Curb & Parapet Flashing ........................................... 44
Double Drain Installation Instructions ......................................................... 45
VL-500-6 – Double Drain ............................................................................. 45
Pipe & Penetration Flashing Installation Instructions ............................ 46
VL-500-8 – Pipe & Penetration Flashing ...................................................... 46
Vertical Termination Installation Instructions ............................................47
VL-500-9AB – Options 1 & 2: Vertical Terminations ..................................... 47
VL-500-9CD – Options 3 & 4: Vertical Terminations ..................................... 48
VL-500-9EF – Options 5 & 6: Vertical Terminations ..................................... 49
Plaza Deck Installation Instructions ............................................................. 50
VL-500-10A – Insulated Plaza Deck ............................................................. 50
VL-500-10B – Paver Plaza Deck .................................................................. 51
VL-500-10C – Mortar Bed w/ Paver Plaza Deck ........................................... 52
34
Vapor-Lock Hot-Applied Waterproofing System
(For Applications over Light-Weight Concrete or Wood Substrates)
DESCRIPTION
Carlisle’s Vapor-Lock System utilizes the CCW-711-90 sheet membrane as a preformed
first course on difficult-to-waterproof substrates such as lightweight structural
concrete and wood. The CCW-711-90 sheet membrane is a 90-mil composite
consisting of a self-adhering rubberized asphalt membrane laminated to high-strength,
heat resistant woven polypropylene mesh. The woven mesh is designed to withstand
high temperatures, allowing the membrane to become an integral reinforcement part
of the CCW-500R Hot-Applied Membrane System.
The second course of the Carlisle Vapor-Lock System is the application of CCW-500.
The CCW-500 is a single-component rubberized asphalt compound that forms a tough,
flexible, monolithic membrane over the CCW-711 sheet membrane. The fast setup time
speeds the completion of the waterproofing system.
The Vapor-Lock System is used to waterproof lightweight structural decks, inverted
roof systems with steel decks covered by gypsum roof decking board or plywood. The
Vapor-Lock System is also ideal for conventional waterproofing of split slabs, tunnels,
and plaza decks.
INSTALLATION GUIDELINES
This application guide has been assembled to assist in the application of CCW Vapor
Lock and is intended to offer guidance to the construction community. It is intended
to be used in conjunction with current CCW published literature. Other acceptable
methods of application may be incorporated during construction that are not depicted
in this guide provided all applications follow proven and sound construction techniques.
LIMITATIONS
• Do not apply CCW-711-90 membrane if temperature is less than 25°F.
• Do not apply CCW-500 membrane if temperature is less than 0°F. Do not install
waterproofing to a damp, frosty or contaminated surface.
• Alternate Substrates: Adequate structural support and the number, type and
location of fasteners required to meet applicable codes should be determined and
verified by the project engineer.
• Steel decking shall be 22 gauge minimum covered with 5/8" minimum fire-rated
Type X gypsum board or approved equal.
• Wood decking shall be ½" minimum exterior grade tongue-and-groove plywood
installed with the long dimension perpendicular to joists. All butt joints shall be
supported by framing.
ACCESSORIES
• CCW 550 Primer
• CCW-AWP Contact Adhesive
• CCW-702LV Contact Adhesive
• CCW-702 Contact Adhesive
• CCW-EJ-500
• CCW-711-90
• CCW Protection Board H
35
Vapor-Lock Hot-Applied Waterproofing System
(For Applications over Light-Weight Concrete or Wood Substrates)
• CCW Protection Board HS
• CCW MiraDRAIN Drainage Composite
• CCW 300HV
• CCW-201 Sealant
INSTALLATION GUIDELINES
This application guide has been assembled to assist in the application of CCW Vapor
Lock and is intended to offer guidance to the construction community. It is intended
to be used in conjunction with current CCW published literature. Other acceptable
methods of application may be incorporated during construction that are not depicted
in this guide provided all applications follow proven and sound construction techniques.
COORDINATION
• Pre-construction meeting shall cover all decisions pertaining to design of
waterproofing membrane to achieve a continuous, water-tight building structure.
• Review submittals, surface preparation, installation procedures, special details,
sequence of construction, responsibilities, mock-up requirements, inspection,
testing, protection of membrane, and repair procedures.
• Mock-up shall establish procedures and workmanship that must be maintained
during installation.
• Review adjacent materials such as drains, doors, parapets, penetrations, and
other site conditions for conformance to manufacturer’s application instructions.
SUBSTRATE
• Ensure all surfaces are installed in accordance with manufacturer specifications.
• Substrate shall be dry, clean, sound, and free of dust, dirt, residue and all other
surface contaminants.
• Verify substrate is flat, free of fins and planar irregularities.
• Substrate systems and the structural performance thereof shall be engineered by
others.
• Prevent the accumulation of water infiltration behind the substrate.
• Unsatisfactory conditions shall be reported and corrected prior to application of
CCW materials.
DELIVERY, STORAGE AND HANDLING
• Deliver CCW materials in original unopened packages.
• Protect CCW materials during transportation, storage, and installation to avoid
physical damage.
• Store CCW materials in a cool dry area protected from direct sunlight and extreme
heat.
36
Vapor-Lock Hot-Applied Waterproofing System
(For Applications over Light-Weight Concrete or Wood Substrates)
APPLICATION
Surface Preparation: The substrate surface must be thoroughly clean, dry and free
from any surface contaminates or cleaning residue that may harmfully affect the
adhesion of the membrane.
Detailing and Flashing: Detail expansion joints per manufacturer’s recommendation.
Preferred Curb and Parapet Flashing Method (VL- 500-4A): Apply CCW Contact
Adhesive at the juncture of all horizontal surfaces and vertical surfaces to the height
indicated on the drawings (8" min. recommended), such as parapet walls, curbs,
columns and all penetrations through the deck. Avoid puddles. Allow primer to dry for
one hour minimum, eight hours maximum. Membrane will not properly adhere to wet
primer. Apply 90 mils of CCW-500 membrane to cover primed areas. Install CCW-711-
90 sheet membrane or uncured neoprene flashing into this first course of CCW-500 to
cover the vertical section and extend 6" onto deck surface. Flashing installation may be
done during crack and joint. Completely cover all flashing material during installation of
the subsequent layers of CCW-500 membrane.
At the juncture of all horizontal surfaces to vertical surfaces, such as parapet walls,
curbs, columns and all penetrations through the deck, apply CCW Contact Adhesive on
the vertical sections to the height indicated on the drawings 8" min. recommended).
Allow primer to dry. Apply the CCW-500 over the primed substrate. Install CCW-711-
90-mil or over the CCW-500 to cover the vertical section and extend 6" onto the deck
surface. Install CCW-500 Membrane over horizontal portion of flashing and onto the
vertical portion during the field membrane.
INSTALLATION
Terminate flashing on wall per Carlisle 500-9 Details. Install CCW-500 Membrane over
horizontal portion of flashing and onto the vertical portion during the field membrane
installation.
Install Sure-Seal® EPDM, Sure-Seal FleeceBACK® 115-mil EPDM or Sure-Seal
FleeceBACK 120-mil AFX TPO flashings in exposed areas per Carlisle recommendations.
Apply a thin film of CCW Contact Adhesive in a four foot square area around drains.
Allow primer to dry one hour minimum, eight hours maximum. Apply 90 mil of CCW-
500 membrane to cover primed areas. Install a three foot square section of CCW-
711-90 or uncured neoprene flashing over the drain and onto the deck. No splices
or seams are allowed within three inches of the drain flange. Terminate the flashing
under the clamping ring of the drain and cut away the inner portion of the flashing.
Use firm pressure to press the flashing against the CCW-500 surface and ensure good
adhesion. Do not interfere with weep holes.
Apply CCW Contact Adhesive to all surfaces to receive CCW-711-90 sheet membrane.
Avoid puddles. Allow primer to dry for one hour minimum, eight hours maximum.
Membrane will not properly adhere to wet primer.
Apply CCW-711-90 sheet membrane from low to high point, in a shingle fashion so that
laps will shed water.
Apply CCW-711-90 sheet membrane from low to high point, in a shingle fashion so
that laps will shed water. Begin installation at low edge of deck overlapping horizontal
portion of previously installed flashings.
37
Vapor-Lock Hot-Applied Waterproofing System
(For Applications over Light-Weight Concrete or Wood Substrates)
Overlap all edges at least 2-½". End laps shall be staggered. Place sheet membrane
carefully so as to avoid wrinkles and fishmouths. After installation, roll with a metal
roller wrapped with a resilient material. Roller should be 18"-24" wide and weigh at
least 100 lbs. Heat CCW-500 membrane blocks in a twin wall kettle with continuous
agitation (Caution: Do not exceed maximum safe operating temperatures of 375°F.)
Apply a coat of CCW-500 Hot-Applied Membrane at a rate of 13 sq. ft. per gallon or as
required to obtain an average thickness of 125 mils. Total thickness of the CCW Vapor-
Lock System shall be 215 mils.
Apply CCW-500 at 125 mils over the CCW-711-90 flashing or uncured neoprene
flashing.
Protection Course: The membrane must be protected from damage. Install CCW
Protection Board H or HS while CCW-500 is still warm and tacky. CCW Protection
Board shall be spliced together using CCW-500 for expanded warranties. Integrity
testing can be performed with the protection board installed. Install CCW MiraDRAIN
and CCW Root Barrier relative to the requirements of the designed overburden.
Testing: Test is required for all expanded warranties beyond the standard material
warranty of horizontal applications. The test can be done with Electronic Vector
Mapping or flood testing. Flood testing requires 2" minimum head of water for a period
of 24 hours.
38
Vapor-Lock Detail
Crack Treatment (VL-500-1)
39
Vapor-Lock Detail
Expansion Joints Less Than ½" (VL-500-3A)
40
Vapor-Lock Detail
Perimeter Expansion Joint (VL-500-3B)
41
Vapor-Lock Detail
CCW-EJ-500 Expansion Joint (VL-500-3D)
42
Vapor-Lock Detail
Non-Exposed Curb & Parapet (VL-500-4A)
43
Vapor-Lock Detail
Exposed Curb & Parapet Flashing (VL-500-4B)
44
Vapor-Lock Detail
Double Drain Detail (VL-500-6)
45
Vapor-Lock Detail
Pipe and Penetration Flashing (VL-500-8)
46
Vapor-Lock Detail
Options 1 & 2: Vertical Terminations (VL-500-9AB)
47
Vapor-Lock Detail
Options 2 & 3: Vertical Terminations (VL-500-9CD)
48
Vapor-Lock Detail
Options 4 & 5: Vertical Terminations (VL-500-9EF)
49
Vapor-Lock Detail
Insulated Plaza Deck (VL-500-10A)
50
Vapor-Lock Detail
Paver Plaza Deck (VL-500-10B)
51
Vapor-Lock Detail
Mortar Bed with Paver Plaza Deck (VL-500-10C)
52
MiraSEAL 100% Solids, Fluid-Applied Waterproofing System
Table of Contents
Description .............................................................................................................. 54
Limitations ............................................................................................................... 54
Accessories............................................................................................................. 54
Coordination ........................................................................................................... 55
Substrate.................................................................................................................. 55
Delivery, Storage, and Handling...................................................................... 55
Application .............................................................................................................. 55
60-mil Un-Reinforced MiraSEAL System (Typical Section) ................. 58
MS-1A.60 – 60-mil Insulated Plaza Deck ..................................................... 58
120-mil Reinforced Miraseal System ............................................................ 59
Crack Treatment Installation Instructions .................................................. 59
MS-1A – Crack Treatment ............................................................................ 59
MS-1B – Plywood Joint ................................................................................ 60
Foundation Wall Section Installation Instructions................................... 61
MS-2A – Option 1: Miraseal at Wall and Footing .......................................... 61
MS-2B – Option 2: Miraseal at Wall and Footing .......................................... 62
Expansion Joint Installation Instructions ................................................... 63
MS-3A – Expansion Joints Less Than ½” .................................................... 63
MS-3B – Perimeter Expansion Joint Less Than ½” ...................................... 64
MS-3C – CCW-EJ-500 Expansion Joint ....................................................... 65
MS-3D – CCW-EJ-500 Perimeter Deck to Wall Expansion Joint .................. 66
Curb & Parapet Flashing Installation Instructions................................... 67
MS-4A – Curb & Parapet ............................................................................. 67
MS-4B – Planter .......................................................................................... 68
Outside Corner Installation Instructions ..................................................... 69
MS-5A – Outside Corner .............................................................................. 69
Double Drain Installation Instructions ......................................................... 70
MS-6 – Double Drain ................................................................................... 70
Pipe & Penetration Flashing Installation Instructions .............................71
MS-8A – Pipe & Penetration Flashing .......................................................... 71
Vertical Termination Installation Instructions ........................................... 72
MS-9A – Miraseal Termination..................................................................... 72
Plaza Deck Installation Instructions ............................................................. 73
MS-10A – Insulated Plaza Deck ................................................................... 73
MS-10B – Paver Plaza Deck......................................................................... 74
MS-10C – Mortar Bed with Paver Plaza Deck .............................................. 75
MS-10D – Sand Bed with Paver Plaza Deck ................................................. 76
MS-10E – Concrete Topping Slab ................................................................. 77
MS-10F – Tunnel Roof ................................................................................. 78
53
MiraSEAL 100% Solids, Fluid-Applied Waterproofing System
DESCRIPTION
MiraSEAL is a 100%-solids, fluid-applied, single-component, moisture-reacted,
elastomeric, coal-tar and solvent-free, modified polymer that cures to form a flexible,
monolithic, waterproof membrane on vertical and horizontal surfaces. Due to the
moisture-reactive and non-gassing properties of the membrane, it provides tenacious
adhesion to concrete substrates above- and below-grade, preventing lateral water
migration, even with moisture present in the concrete. The inherent toughness and
resilience of MiraSEAL enables it to bridge structural or shrinkage cracks that may
develop in the substrate. MiraSEAL can be applied wet on wet in a horizontal application
resulting in reduced installation time.
MiraSEAL is available in a single viscosity for both horizontal and vertical surfaces.
Typical applications are between structural slab and wearing course on parking garages,
plaza decks, balconies, roof decks, terraces, mechanical equipment rooms, wetrooms,
malls, kitchens and shower stalls. MiraSEAL is ideally suited for waterproofing on
below-grade foundation walls, tunnels, planters and other areas where a seamless,
elastomeric waterproofing is required. MiraSEAL may also be used as a sealant.
Installation Guidelines
This application guide has been assembled to assist in the application of CCW Miraseal
and is intended to offer guidance to the construction community. It is intended to be
used in conjunction with current CCW published literature. Other acceptable methods
of application may be incorporated during construction that are not depicted in this
guide provided all applications follow proven and sound construction techniques.
LIMITATIONS
• Do not apply MiraSEAL to wet or contaminated surfaces.
• Not recommended for exposed or wearing surfaces.
• If metal pan is used for concrete form, the metal pan must be vented.
• Surface temperature must be above 40°F.
• Do not leave exposed for more than 14 days.
• Not compatible with rubberized asphalts. Contact CCW Representative if the
MiraSEAL is to come into contact with a rubberized asphalt.
ACCESSORIES
• CCW-500 Reinforcing Fabric
• CCW LiquiFiber
• CCW Protection Board H
• CCW Protection Board HS
• CCW-EJ-500
• CCW MiraDRAIN Drainage Composite
• CCW-201 Sealant
54
MiraSEAL 100% Solids, Fluid-Applied Waterproofing System
COORDINATION
• Pre-construction meeting shall cover all decisions pertaining to design of
waterproofing membrane to achieve a continuous, water-tight building structure.
• Review submittals, surface preparation, installation procedures, special details,
sequence of construction, responsibilities, mock-up requirements, inspection,
testing, protection of membrane, and repair procedures.
• Mock-up shall establish procedures and workmanship that must be maintained
during installation.
• Review adjacent materials such as drains, doors, parapets, penetrations, and
other site conditions for conformance to manufacturer’s application instructions.
SUBSTRATE
• Ensure all surfaces are installed in accordance with manufacturer specifications.
Concrete should cure for a minimum of 3 days and have a light broom finish.
• Substrate shall be dry to the touch, clean, sound, and free of dust, dirt, residue
and all other surface contaminants.
• Verify substrate is flat, free of fins and planar irregularities.
• Substrate systems and the structural performance thereof shall be engineered by
others.
• Prevent the accumulation of water infiltration behind the substrate.
• Unsatisfactory conditions shall be reported and corrected prior to application of
CCW materials.
DELIVERY, STORAGE AND HANDLING
• Deliver CCW materials in original unopened packages.
• Protect CCW materials during transportation, storage, and installation to avoid
physical damage.
• Store CCW materials in a cool dry area protected from direct sunlight and extreme
heat.
• When stored at temperatures below 80°F, shelf life is 6 months in the original,
unopened container.
APPLICATION
Surface Preparation: New concrete shall be water-cured, trowel-finished, followed by
a light, hair broom and in place for 3 days minimum. If curing compounds are required,
they shall be 100% Sodium Silicate and shall be approved by CCW. Surfaces shall be
structurally sound, dry, and free of oil, grease, dirt, laitance, curing or release agents
and other contamination that may harmfully affect the adhesion of the membrane.
Mortar joints on block walls shall be struck flush with the block surface.
Remove splatters, fins, ridges or other projections to provide a smooth, level surface.
Fill tie rod holes, honey combs, rock pockets, spalls or other voids and indentations
with non-shrink grout. Saw-cut moving cracks greater than 1/16" to ¼" wide x ¼" deep.
Grind or fill (as required) surface at cold joints where each pour is at a different plane,
to provide a smooth and level surface. Clean metal to expose a bright finish. A Concrete
Surface Profile (CSP) of 2 or 3 is recommended to promote a mechanical bond between
concrete substrate and MiraSEAL.
55
MiraSEAL 100% Solids, Fluid-Applied Waterproofing System
Detail Work: Clean joints and saw-cut cracks. All moving cracks over 1/16" wide and all
expansion joints less than 1" wide shall be cleaned, primed, fitted with a backing rod
and caulked with Carlisle Polyurethane Sealant as recommended by the data sheet. For
larger joints, contact CCW representative.
Apply a one inch, 45º angle cant of CCW-201 sealant at the juncture of all vertical and
horizontal surfaces and inside corners, at pipes, vents and other projections.
Priming: Primer is not required for adhesion to dry, non-porous concrete. However,
if pinhole and blister problems occur as a result of air and/or moisture vapors
being trapped or emitted from the concrete and/or environmental conditions, it is
recommended that a thin-mil coat application be applied to remove trapped air/vapor.
This is intended to promote and establish an intimate bond with the substrate.
Metal: Mechanically clean to bright finish. Remove dust and debris and solvent wipe
with clean cloth. Sawcut ¼" x ¼" between drain flange and substrate. Install CCW-201
sealant struck flush with surface.
Horizontal Application: Apply MiraSEAL over cleaned flange of drains, taking care
not to fill weep holes. Drain flange of 3" minimum width recommended. Using a roller,
trowel, or brush apply MiraSEAL at 26 sq. ft. per gallon or as required to obtain a 60-
mil thickness. Apply MiraSEAL in one coat using a roller, trowel, or squeegee at 26 sq.
ft. per gallon or as required to obtain a 60-mil thickness to the entire area to receive
waterproofing, including overall detail coats.
Vertical Application: Apply MiraSEAL in one coat using a roller, trowel, or squeegee
at 26 sq. ft. per gallon or as required to obtain a 60-mil thickness to the entire area to
receive waterproofing, including overall detail coats. Wait for material to film form and
become stable between each coat.
Reinforced Systems: Apply MiraSEAL in one coat using a roller, trowel, or squeegee
at 26 sq. ft. per gallon or as required to obtain a 60-mil thickness to the entire area
to receive waterproofing, including over all details coats. Immediately install CCW
Reinforcing Fabric into the wet MiraSEAL. Brush or roll the fabric into the wet MiraSEAL,
ensuring it is completely saturated into the wet MiraSEAL. Overlap adjoining fabric
sheets a minimum of ½". Ensure overlapping fabric is completely saturated in between
overlaps. Install carefully to avoid wrinkles. In the event of wrinkles or fishmouths,
cut the fabric and overlap the excess to avoid trapped air. Apply an additional coat of
MiraSEAL on top of the fabric at 26 sq. ft. per gallon or as required to obtain a 60-mil
thickness, extending past the edge of the fabric to completely encapsulate it. The first
coat, CCW-500 Reinforcing Fabric, and the second coat will need to all be completed in
the same day or working period. Do not apply the first coat and CCW-500 Reinforcing
Fabric in an area that can’t be coated with the second coat in the same day. Total
system dry film thickness shall be 120-mils. Do not leave Reinforcing Fabric exposed
overnight.
All fluid-applied product application rates are based on theoretical coverage relative
to the percentage of solids in the material. These are minimum application rates to
achieve the required dry film thickness for the system and do not account for substrate
condition or porosity. A thicker application of the product may be necessary to achieve
the required dry film thickness for system relative to the substrate.
56
MiraSEAL 100% Solids, Fluid-Applied Waterproofing System
57
60-mil Un-reinforced MiraSEAL System
(Typical Section):
MiraSEAL Detail
60-mil Insulated Plaza Deck (MS-1A.60)
Specific details for the CCW Miraseal 60-mil System can be found at
www.carlisleccw.com
58
120-mil Reinforced Miraseal System:
MiraSEAL Detail
Crack Treatment (MS-1A)
59
MiraSEAL Detail
Plywood Joint (MS-1B)
60
MiraSEAL Detail
Option 1: Miraseal at Wall and Footing (MS-2A)
61
MiraSEAL Detail
Option 2: Miraseal at Wall and Footing (MS-2B)
62
MiraSEAL Detail
Expansion Joints Less Than ½" (MS-3A)
63
MiraSEAL Detail
Perimeter Expansion Joint Less Than ½" (MS-3B)
64
MiraSEAL Detail
CCW-EJ-500 Expansion Joint (MS-3C)
65
MiraSEAL Detail
CCW-EJ-500 Deck to Wall Expansion Joint (MS-3D)
66
MiraSEAL Detail
Curb & Parapet (MS-4A)
67
MiraSEAL Detail
Planter (MS-4B)
68
MiraSEAL Detail
Outside Corner (MS-5A)
69
MiraSEAL Detail
Double Drain Detail (MS-6)
70
MiraSEAL Detail
Pipe and Penetration Flashing (MS-8A)
71
MiraSEAL Detail
Miraseal Termination (MS-9A)
72
MiraSEAL Detail
Insulated Plaza Deck (MS-10A)
73
MiraSEAL Detail
Paver Plaza Deck (MS-10B)
74
MiraSEAL Detail
Mortar Bed with Paver Plaza Deck (MS-10C)
75
MiraSEAL Detail
Sand Bed with Paver Plaza Deck (MS-10D)
76
MiraSEAL Detail
Concrete Topping Slab (MS-10E)
77
MiraSEAL Detail
Tunnel Roof (MS-10F)
78
Liquid-Applied, Single-Component,
CCW-525 Modified Polyurethane Waterproofing System
Table of Contents
Description .............................................................................................................. 80
Installation Guidelines ........................................................................................ 80
Limitations ............................................................................................................... 80
Accessories............................................................................................................. 80
Coordination ............................................................................................................81
Substrate...................................................................................................................81
Delivery, Storage, and Handling.......................................................................81
Application ...............................................................................................................81
60-mil Insulated Plaza Deck (Typical Section) .......................................... 84
525-10A.60 – 60-mil Insulated Plaza Deck .................................................. 84
120-mil Details ....................................................................................................... 85
Crack Treatment Installation Instructions .................................................. 85
525R-1A – Crack Treatment ......................................................................... 85
525R-1B – Plywood Joint ............................................................................. 86
525R-1C – Plywood Deck Edge .................................................................... 87
Foundation Wall Section Installation Instructions................................... 88
525R-2A – Foundation Footing .................................................................... 88
Expansion Joint Installation Instructions ................................................... 89
525R-3A – Expansion Joints Less Than ½" ................................................. 89
525R-3B – Perimeter Expansion Joint Less Than ½" ................................... 90
525R-3E – CCW-EJ-500 Expansion Joint .................................................... 91
525R-3F – CCW-EJ-500 Perimeter Deck to Wall Expansion Joint ................ 92
Curb & Parapet Flashing Installation Instructions................................... 93
525R-4A – Curb and Parapet ....................................................................... 93
525R-4B – Option 1: Plywood Curb and Parapet with Metal Flashing .......... 94
525R-4C – Option 2: Plywood Curb and Parapet ......................................... 95
Double Drain Installation Instructions ......................................................... 96
525R-6A – Double Drain .............................................................................. 96
Planter Installation Instructions ..................................................................... 97
525R-7A – Planter ....................................................................................... 97
Pipe & Penetration Flashing Installation Instructions ............................ 98
525R-8A – Deck Pipe and Penetration Flashing ........................................... 98
525R-8B – Wall Pipe and Penetration Flashing ............................................ 99
Vertical Termination Installation Instructions ......................................... 100
525R-9A – Foundation Wall Termination .................................................... 100
Plaza Deck Installation Instructions ........................................................... 101
525R-10A – Pavers on Sand Bed Plaza Deck ............................................. 101
525R-10B – Tile/Paver on Mortar Bed Plaza Deck ..................................... 102
525R-10D – Pavers on Pedestals Plaza Deck ............................................. 103
525R-10E – Concrete Topping Slab Plaza Deck.......................................... 104
525R-10F – Concrete Topping Slab with Insulation .................................... 105
Inside/Outside Corners and Angle Changes
Installation Instructions ................................................................................... 106
525R-15A – Inside/Outside Corners and Angle Changes ............................ 106
79
Liquid-Applied, Single-Component,
CCW-525 Modified Polyurethane Waterproofing System
DESCRIPTION
CCW-525 is a liquid-applied, single-component, moisture-cured, elastomeric, coal-
tar free, modified polyurethane that cures to form a flexible, monolithic, waterproof
membrane on vertical or horizontal surfaces, above or below grade. The membrane
has tenacious adhesion to concrete substrates preventing lateral water migration.
The inherent toughness and resilience of CCW-525 Membrane enables it to bridge
structural or shrinkage cracks which may develop in the substrate.
CCW-525 is available in two viscosities (H & V) for application to horizontal and vertical
surfaces. Typical applications are between structural slab and wearing course on
parking garages, plaza decks, balconies, roof decks, terraces, mechanical equipment
rooms, wetrooms, malls, kitchens and shower stalls. CCW-525 is ideally suited for
waterproofing on below-grade foundation walls, tunnels, planters and other areas
where a seamless, elastomeric waterproofing is required.
INSTALLATION GUIDELINES
This application guide has been assembled to assist in the application of CCW 525 and
is intended to offer guidance to the construction community. It is intended to be used
in conjunction with current CCW published literature. Other acceptable methods of
application may be incorporated during construction that are not depicted in this guide
provided all applications follow proven and sound construction techniques.
LIMITATIONS
• Do not apply CCW-525 to a wet, damp or contaminated surface
• Not recommended for exposed or wearing surfaces
• If metal pan is used for concrete form, the metal pan must be vented
• Surface temperature must be above 40°F
• Do not use around swimming pools or other areas where pool chemicals are used.
ACCESSORIES
• CCW DCH Reinforcing Fabric
• CCW LiquiFiber
• CCW Protection Board H
• CCW Protection Board HS
• CCW-EJ-500
• CCW MiraDRAIN Drainage Composite
• CCW-201 Sealant
80
Liquid-Applied, Single-Component,
CCW-525 Modified Polyurethane Waterproofing System
COORDINATION
• Pre-construction meeting shall cover all decisions pertaining to design of
waterproofing membrane to achieve a continuous, water-tight building structure.
• Review submittals, surface preparation, installation procedures, special details,
sequence of construction, responsibilities, mock-up requirements, inspection,
testing, protection of membrane, and repair procedures.
• Mock-up shall establish procedures and workmanship that must be maintained
during installation.
• Review adjacent materials such as drains, doors, parapets, penetrations, and
other site conditions for conformance to manufacturer’s application instructions.
SUBSTRATE
• Ensure all surfaces are installed in accordance with manufacturer specifications.
• Substrate shall be dry, clean, sound, and free of dust, dirt, residue and all other
surface contaminants.
• Verify substrate is flat, free of fins and planar irregularities.
• Substrate systems and the structural performance thereof shall be engineered by
others.
• Prevent the accumulation of water infiltration behind the substrate.
• Unsatisfactory conditions shall be reported and corrected prior to application of
CCW materials.
DELIVERY, STORAGE AND HANDLING
• Deliver CCW materials in original unopened packages.
• Protect CCW materials during transportation, storage, and installation to avoid
physical damage.
• Store CCW materials in a cool dry area protected from direct sunlight and extreme
heat.
• When stored at temperatures below 80°F, shelf life is 12 months in the original,
unopened container.
APPLICATION
Surface Preparation: New concrete shall be water-cured, trowel-finished, followed
by a light, hair broom and in place for 14 days minimum, 28 days preferred. If curing
compounds are required, they shall be 100% Sodium Silicate and shall be approved by
CCW. Surfaces shall be structurally sound, dry, and free of oil, grease, dirt, laitance,
curing or release agents and other contamination which may harmfully affect the
adhesion of the membrane. Mortar joints on block walls shall be struck flush with the
block surface.
Remove splatters, fins, ridges or other projections to provide a smooth, level surface.
Fill tie rod holes, honey combs, rock pockets, spalls or other voids and indentations
with non-shrink grout. Saw-cut moving cracks greater than 1/16" in width to ¼" wide
x ¼" deep.
Grind or fill (as required) surface at cold joints where each pour is at a different plane,
to provide a smooth and level surface. Clean metal to expose a bright finish.
81
Liquid-Applied, Single-Component,
CCW-525 Modified Polyurethane Waterproofing System
Detail Work: Clean joints and saw cut cracks. All moving cracks over 1/16" wide and
all expansion joints less than 1" wide shall be cleaned, primed, fitted with a backing
rod and caulked with CCW-201 non-sag polyurethane sealant. Refer to CCW-201
data sheet for information on the use of this product. For larger joints, contact CCW
representative.
Apply a 1", 45° angle cant of CCW-201 sealant at the juncture of all vertical and
horizontal surfaces including at pipes, vents and other projections.
Apply a bond breaker tape over the Sealant installed in expansion joints. Width of bond
breaker shall be three times joint width.
Priming: Primer is not required for adhesion to dry, non-porous concrete. However, if
pinhole and blister problems occur as a result of air and/or moisture vapors emitted
from the concrete and environmental conditions, it is recommended that the surface be
primed. Please contact CCW Technical Services regarding primer.
Apply 2 part epoxy Primer to metal surfaces immediately after sanding and cleaning.
Refer to manufacturer’s data sheet for information on the use of this product.
Horizontal Application: Apply CCW-525 over cleaned, primed flange of drains, taking
care not to fill weep holes. Using a notched squeegee, apply CCW-525-H at 22 sq.
ft. per gallon or as required to obtain a 60-mil thickness, to the entire area to receive
waterproofing, including overall detail coats.
Vertical Application: Using a roller, apply CCW-525 V in one coat at a rate of 22
square feet per gallon or as required to obtain a final dry film thickness of 60 mils. Wait
24 hours between each coat if subsequential coats are required.
CCW-525R Reinforced Systems: Apply CCW-525-H at 22 square feet per gallon or
as required to obtain a 60-mil thickness to the entire area to receive waterproofing,
including overall detail coats. Use a ¼" notched squeegee or flat squeegee with guide
pins to achieve a uniform thickness. Immediately install CCW LiquiFiber-W glass mat or
CCW DCH white polyester reinforcing fabric into the uncured CCW-525. Install carefully
to avoid wrinkles. In the event of wrinkles or fishmouths, cut the fabric and overlap the
excess to avoid trapped air. Once the coating has cured to a firm consistency, apply
an additional coat of CCW-525 at 22 sq. ft. per gallon or as required to obtain a 60
mil thickness, extending past the edge of the fabric to completely encapsulate it. Total
system dry film thickness is 120 mils. Wait 24 hours between each coat.
All fluid-applied product application rates are based on theoretical coverage relative
to the percentage of solids in the material. These are minimum application rates to
achieve the required dry film thickness for the system and do not account for substrate
condition or porosity. A thicker application of the product may be necessary to achieve
the required dry film thickness for system relative to the substrate.
Protection: The membrane must be protected from damage by future operations
and other trades. The applicator shall install protection material applicable to jobsite
conditions, to protect the membrane. Protection course must be CCW Protection Board
products that correspond to horizontal or vertical applications.
82
Liquid-Applied, Single-Component,
CCW-525 Modified Polyurethane Waterproofing System
Install protection course on vertical walls immediately after membrane has cured (36
hours at 75°F). Install protection course on horizontal application immediately following
successful flood testing. If flood test is delayed, install a temporary covering to protect
the membrane from other trades.
Flood Test: After membrane has cured 36 to 72 hours, plug drains and provide
necessary barriers to contain flood water. Flood deck with a 2" head of water and
allow to stand for 24 hours. Check for leaks and immediately make repairs if required.
Retest after any repairs have been made.
Clean Up: Before material cures, clean adjacent areas to remove stains or spills and
clean tools with toluene or xylene. Do not wash off skin with solvents.
Verify specified warranty requirements to determine which CCW 525 System
should be used on each project. CCW 525R (120-mil Reinforced) system is
required for all Ultra (Labor & Material) Warranties. Please verify CCW Specific
Waterproofing System requirements with your local CCW Sales Representative
prior to bidding or starting project in order for the project to be eligible for the
specified CCW 525 or CCW 525-R System Warranties.
83
60-mil Un-reinforced MiraSEAL System
(Typical Section):
CCW-525 Detail
60-mil Insulated Plaza Deck (525-10A.60)
84
120-mil Reinforced CCW 525R System:
CCW-525 Detail
Crack Treatment (525R-1A)
85
CCW-525 Detail
Plywood Joint (525R-1B)
86
CCW-525 Detail
Plywood Deck Edge (525R-1C)
87
CCW-525 Detail
Foundation Footing (525R-2A)
88
CCW-525 Detail
Expansion Joints Less Than ½" (525R-3A)
89
CCW-525 Detail
Perimeter Expansion Joint Less Than ½" (525R-3B)
90
CCW-525 Detail
CCW-EJ-500 Expansion Joint (525R-3E)
91
CCW-525 Detail
CCW-EJ-500 Deck to Wall Expansion Joint (52R-3F)
92
CCW-525 Detail
Curb & Parapet (525R-4A)
93
CCW-525 Detail
Option 1: Plywood Curb and Parapet with Metal Flashing (525R-4B)
94
CCW-525 Detail
Option 2: Plywood Curb and Parapet (525R-4C)
95
CCW-525 Detail
Double Drain Detail (525R-6A)
96
CCW-525 Detail
Planter (525R-7A)
97
CCW-525 Detail
Deck Pipe and Penetration Flashing (525R-8A)
98
CCW-525 Detail
Wall Pipe and Penetration Flashing (525R-8B)
99
CCW-525 Detail
Foundation Wall Termination (525R-9A)
100
CCW-525 Detail
Pavers on Sand Bed Plaza Deck (525R-10A)
101
CCW-525 Detail
Tile/Paver on Mortar Bed Plaza Deck (525R-10B)
102
CCW-525 Detail
Pavers on Pedestals Plaza Deck (525R-10D)
103
CCW-525 Detail
Concrete Topping Slab Plaza Deck (525R-10E)
104
CCW-525 Detail
Concrete Topping Slab with Insulation (MS-10F)
105
CCW-525 Detail
Inside/Outside Corners (525R-15A)
106
MiraDRI 860/861 Self-Adhering Sheet Waterproofing
Table of Contents
Description ............................................................................................................ 109
Installation Guidelines ...................................................................................... 109
Limitations ............................................................................................................. 109
Accessories........................................................................................................... 109
Coordination ..........................................................................................................110
Substrate.................................................................................................................110
Delivery, Storage, and Handling.....................................................................110
Application .............................................................................................................110
860-P System (LiquiDeck @ 60 mils and CCW MiraDRI 860/861
Concrete Plaza Deck (Typical Section) .......................................................113
860P-10A – Concrete Plaza Deck ...............................................................113
CCW MiraDRI 860/861 Details ........................................................................114
Crack Treatment Installation Instructions .................................................114
860-1A – Crack Treatment ..........................................................................114
Foundation Wall Section Installation Instructions..................................115
860-2A – Footing Cross Section .................................................................115
860-2B – Elevated Interior Slab Footing Cross Section ...............................116
860-2C – Footing Cross Section with Insulation..........................................117
Expansion Joint Installation Instructions ..................................................118
860-3A – 1" Expansion Joint (Deck or Wall) ...............................................118
860-3B – 1" Perimeter Expansion Joint at Deck to Wall ..............................119
860-3C – 2" Perimeter Expansion Joint ..................................................... 120
860-3D – 2" or Less Bellows Expansion Joint (Deck or Wall) .................... 121
860-3E – 2" Inside Corner Expansion Joint ............................................... 122
Curb & Parapet Flashing Installation Instructions................................. 123
860-4A – Option 1: Flashing at Deck to Curb or Parapet
with CCW MiraDRI 860/861....................................................................... 123
860-4B – Option 2: Flashing at Deck to Curb or Parapet
with CCW 703V Liquiseal ........................................................................... 124
Double Drain Installation Instructions ....................................................... 125
860-6 – Double Drain ................................................................................ 125
Pipe & Penetration Flashing Installation Instructions .......................... 126
860-8A – Option 1: Pipe and Penetration Flashing
with CCW MiraDRI 860/861....................................................................... 126
860-8B – Option 2: Pipe and Penetration Flashing
with CCW 703V Liquiseal ........................................................................... 127
860-8J – Small Penetration ....................................................................... 128
Vertical Termination Installation Instructions ......................................... 129
860-9A – Vertical Wall Termination............................................................ 129
860-9B – Vertical Wall Termination with Termination Bar .......................... 130
Plaza Deck Installation Instructions ........................................................... 131
860-10A – Split-Slab Plaza Deck ............................................................... 131
860-10B – Insulated Plaza Deck ................................................................ 132
860-10C – Paver Plaza Deck ..................................................................... 133
860-10D – Mortar Bed with Pavers Plaza Deck ......................................... 134
107
MiraDRI 860/861 Self-Adhering Sheet Waterproofing
Table of Contents
Brick Ledge Installation Instructions.......................................................... 135
860-11A – CCW MiraDRI 860/861 to AVB Tie-In at Brick Ledge ................ 135
Plywood Deck Installation Instructions ..................................................... 136
860-12A – Wood Decking Edge Condition .................................................. 136
860-12B – Wood Decking Wall Condition ................................................... 137
860-12D – Plywood Decks with Thinset Tile .............................................. 138
Inside/Outside Corners and Angle Changes
Installation Instructions ................................................................................... 139
860-15A – Wall/Footing/Outside Corner .................................................... 139
860-15B – Option 1: Vertical Wall Outside Corner ...................................... 140
860-15C – Option 2: Vertical Wall Outside Corner ...................................... 141
Overflow Metal Scupper Installation Instructions ................................. 142
860-18A – Overflow Metal Scupper ........................................................... 142
108
MiraDRI 860/861 Self-Adhering Sheet Waterproofing
DESCRIPTION
CCW MiraDRI 860/861 are self-adhering sheet membranes consisting of 56 mils (1.4
mm) of rubberized asphalt laminated to 4 mils (0.1 mm) of polyethylene to form a
minimum 60-mil (1.5 mm) membrane. CCW MiraDRI 860 membrane, suitable for
installations where the ambient temperature is 40°F (4.4°C) or above. CCW MiraDRI
861 should be used for applications between 25°F (-3.9°C) and 65°F (18°C).
CCW MiraDRI 860/861 membranes are used for vertical and horizontal waterproofing
on structural foundation walls and decks. Below-grade foundation walls, tunnels, split
slabs, plaza decks and parking decks are all areas where CCW MiraDRI 860/861
may be applied. CCW MiraDRI 860/861 also may be used in interior areas such as
mechanical rooms, laboratories, kitchens and bathrooms. CCW MiraDRI 860/861
should be covered with either CCW 200V/300HV Protection Course, CCW Protection
Board, or CCW MiraDRAIN drainage composites.
(City of Los Angeles Research Report Number 25094L)
INSTALLATION GUIDELINES
This application guide has been assembled to assist in the application of CCW MiraDRI
860/861 and is intended to offer guidance to the construction community. It is intended
to be used in conjunction with current CCW published literature. Other acceptable
methods of application may be incorporated during construction that are not depicted
in this guide provided all applications follow proven and sound construction techniques.
LIMITATIONS
• Do not apply where membrane will be subject to continuous exposure to sunlight.
• The membrane should not be left exposed to direct sunlight for longer than 14
days.
• Do not apply primer or membrane to a damp, frosty, frozen, or contaminated
surface.
• Not recommended as a pond or tank liner except for between-slab applications.
• Do not apply over sealants containing coal tar or polysulfides. In the event of
existing bitumen-modified materials, consult your CCW representative.
ACCESSORIES
• CCW 702, 702LV, 702WB, 715, AWP, or Cav-Grip Contact Adhesives
• CCW 703V Liquiseal
• CCW LiquiDeck
• CCW 200V/300HV Protection Fabrics
• CCW Protection Board V
• CCW Protection Board H or HS
• CCW MiraDRAIN Drainage Composite
• CCW-LM-800XL
• CCW GreenBond WB
• CCW 704 Mastic
• CCW-201 Sealant
109
MiraDRI 860/861 Self-Adhering Sheet Waterproofing
COORDINATION
• Pre-construction meeting shall cover all decisions pertaining to design of
waterproofing membrane to achieve a continuous, water-tight building structure.
• Review submittals, surface preparation, installation procedures, special details,
sequence of construction, responsibilities, mock-up requirements, inspection,
testing, protection of membrane, and repair procedures.
• Mock-up shall establish procedures and workmanship that must be maintained
during installation.
• Review adjacent materials such as drains, doors, parapets, penetrations, and
other site conditions for conformance to manufacturer’s application instructions.
SUBSTRATE
• Ensure all surfaces are installed in accordance with manufacturer specifications.
• Substrate shall be dry, clean, sound, and free of dust, dirt, residue and all other
surface contaminants.
• Verify substrate is flat, free of fins and planar irregularities.
• Substrate systems and the structural performance thereof shall be engineered by
others.
• Prevent the accumulation of water infiltration behind the substrate.
• Unsatisfactory conditions shall be reported and corrected prior to application of
CCW materials.
DELIVERY, STORAGE AND HANDLING
• Deliver CCW materials in original unopened packages.
• Protect CCW materials during transportation, storage, and installation to avoid
physical damage.
• Store CCW materials in a cool dry area protected from direct sunlight and extreme
heat.
• Shelf life is 12 months in the original, unopened container for CCW MiraDRI
860/861 and accessory products.
APPLICATION
Preparation: CCW MiraDRI 860/861 can be applied to concrete, metal, wood,
insulated wall systems, or masonry surfaces. All substrates must be clean, dry, and
free of surface irregularities.
Concrete Substrates: Structural concrete must be cured a minimum of 7 days and
lightweight structural concrete must cure a minimum of 14 days before the application
of CCW MiraDRI 860/861. Repair surfaces that are not structurally sound or have
voids, protrusions, rough spalled areas, loose aggregate or exposed course aggregate.
Any voids exceeding a ¼" in width should be filled with latex Portland cement, concrete
or epoxy concrete and troweled smooth to match the existing surface. Protrusions and
other rough areas should be ground off and patched as above. CCW LM 800XL, CCW
201, or CCW 703V may be used to fill small voids, honeycombs or bug holes.
110
MiraDRI 860/861 Self-Adhering Sheet Waterproofing
Masonry Substrate: Apply CCW MiraDRI 960/861 waterproofing over concrete block
with smooth trowel-cut mortar joints or rough surfaces prepared with a parge coat.
Allow the parge coat to dry before priming and installing the CCW MiraDRI 860/861
waterproofing membrane.
Chemical Additives: Concrete shall be cured by water curing method. Any curing
compounds must be of the pure sodium silicate type or clear resin-based materials
without waxes, oils or pigments and be approved by the Carlisle representative. Form
release agents must not transfer to the concrete. Remove forms as soon as possible
from below horizontal slabs to prevent entrapment of excess moisture. Excess moisture
may lead to blistering of the membrane. Curing compounds or form release agents that
adversely affect the adherence of the CCW MiraDRI 860/861 waterproofing membrane
must be removed from the substrate prior to application.
Priming: All concrete, metal, masonry, wood and sheathing substrates require a
CCW Contact Adhesive. Insulated concrete forms require a water-based CCW Contact
Adhesive. Carlisle Coatings & Waterproofing recommends an adhesion test of the CCW
MiraDRI 860/861 on any substrate to verify proper adhesion. Apply the appropriate
CCW Contact Adhesive at the specified coverage rate. Apply Contact Adhesive with
a lambswool roller, brush or spray apparatus. Allow Contact Adhesive to dry for a
minimum of 30 minutes.The CCW Contact Adhesive will dry to a tacky finish. Areas
primed with a CCW Contact Adhesve, but not covered with CCW MiraDRI 860/861
within the same day must be re-primed.
When installing CCW sheet membranes and sheet flashings over gyp-sheathing with
glass-mat facers, coverage rates for contact adhesives and primers will depend on
the porosity and texture of the sheathing and will vary substantially by gypsum-
sheathing brand and manufacturer. To achieve consistent contact adhesive and/or
primer coverage with adequate tack, it may be necessary to decrease the coverage
rate (i.e. increase the amount applied) of the contact adhesive and/or primer and/or
the application of multiple coats. CCW Contact adhesives and primers shall be allowed
to dry completely (lower temperatures will extend drying time) before additional coats
are applied or membranes installed. Caution should be taken as contact adhesives
and/or primers applied to gyp-sheathings with glass-mat facers will take longer to dry
than other substrates. Multiple adhesion tests should be performed randomly to verify
proper application of primer and ensure a successful application.
Detailing: All vertical-to-horizontal transitions must have a ¾" (19.05 mm) fillet of
CCW LM-800XL, CCW-201 Sealant, CCW 703V Liquiseal, or GreenBond WB. Allow
CCW-LM-800XL to cure 1 hour, CCW-703V to cure 4 hours, CCW-201 to cure 16
hours, and GreenBond WB to cure 12 hours before covering with the CCW MiraDRI
860/861 membrane. All inside and outside corners, as well as the vertical-to-horizontal
transitions, should have a minimum 9" strip of CCW MiraDRI 860/861 installed
centered over the transition prior to the field membrane of CCW MiraDRI 860/861. The
CCW MiraDRI 860/861 Membrane Strip should be centered on corners, joints, cracks
and transitions. After field membrane is installed, a sealant bead of CCW LM-800XL,
CCW-704, CCW-201, GreenBond WB, or CCW-703V Liquiseal should all be placed over
all laps at the footing/wall transition extending a minimum of 9" up the wall and 9" out
over the footing. Refer to the standard detail drawings for specific detail instructions.
111
MiraDRI 860/861 Self-Adhering Sheet Waterproofing
Vertical Installation: Start at the low point and work towards the high point. Remove
6-8” (150-200 mm) of the release paper, and then begin applying the membrane.
Press and smooth the membrane against the substrate while pulling the release paper
free. Roll entire membrane and laps with a hard rubber hand roller. Install membrane
with side laps overlapped a minimum of 2-½" (63 mm) and end laps a minimum of 5"
(127 mm). CCW recommends that the membrane be rolled in place immediately after
its placement to ensure full adhesion to the primed substrate. Apply a bead of CCW
704, CCW LM 800XL, GreenBond WB, or CCW 703V Liquiseal at terminations, cut
edges, joints, drains, and penetrations. CCW 704 Mastic should not be installed on the
underside of CCW Miradri 860/861. For walls over 8' (240 cm), the membrane should
be placed in lifts. Protect the CCW MiraDRI 860/861 membrane with the appropriate
CCW MiraDRAIN drainage composite, CCW 200V/300HV Protection Course, or CCW
Protection Board V.
Horizontal Installation: Start at the low point (establish a starting point with a chalk
line if necessary) and work towards the high point in shingle fashion. Remove 2'– 3'
(60-90 cm) of the release paper and apply the membrane to the substrate. Continue
pulling the release paper free while pressing and smoothing the membrane against
the substrate. Apply in a straight line avoiding wrinkles and over-correcting. Roll the
membrane with a minimum 75-lb. (34 kg) linoleum roller. Install membrane with side
laps overlapped a minimum of 2-½" (63 mm) and end laps a minimum of 5" (127 mm).
Apply a bead of CCW-704 Mastic at all terminations of the membrane and T-joints.
Apply a 3/4" (19.05 mm) fillet of CCW LM 800XL, CCW 201, GreenBond WB, or CCW
703V Liquiseal in all inside corners of planter boxes, shower stalls and shower pans.
Patch inadequately lapped seams and damaged areas with CCW MiraDRI 860/861
membrane covering the damaged area by a minimum of 6" (150 mm). “Fish-mouths”
and severe wrinkles should be slit, flaps overlapped and repaired as above. Protect
the CCW MiraDRI 860/861 membrane with the appropriate CCW MiraDRAIN drainage
composite or CCW 300HV Protection Course.
Protection: The membrane must be protected from damage by future operations
and other trades. The applicator shall install protection material applicable to jobsite
conditions, to protect the membrane. Protection course must be CCW Protection Board
products that correspond to horizontal or vertical applications.
Install protection course on vertical walls immediately after membrane has been
installed. Install protection course on horizontal application immediately following
successful flood testing. If flood test is delayed, install a temporary covering to protect
the membrane from damage by other trades.
Verify specified warranty requirements to determine which CCW MiraDRI 860/861
System should be used on each project. The CCW MiraDRI 860-P system is required
on all horizontal decks where a CCW Ultra Warranty (Labor & Material) is required.
Please verify CCW Specific Waterproofing System requirements with your local CCW
Sales Representative prior to bidding or starting project in order to be eligible for the
specified CCW MiraDRI 860/861 or CCW 860-P System Warranties.
The CCW MiraDRI 860-P System consists of an application of CCW LiquiDeck at 60-
wet mils and then a layer of CCW MiraDRI 860/861 on horizontal decks and is required
for CCW Ultra Warranties.
112
MiraDRI 860P Detail
Concrete Plaza Deck (860P-10A)
113
MiraDRI 860/861 Detail
Crack Treatment (860-1A)
114
MiraDRI 860/861 Detail
Footing Cross Section (860-2A)
115
MiraDRI 860/861 Detail
Elevated Interior Slab Footing Cross Section (860-2B)
116
MiraDRI 860/861 Detail
Footing Cross Section with Insulation (860-2C)
117
MiraDRI 860/861 Detail
1" Expansion Joint (Deck or Wall) (860-3A)
118
MiraDRI 860/861 Detail
1" Perimeter Expansion Joint at Deck to Wall (860-3B)
119
MiraDRI 860/861 Detail
2" Perimeter Expansion Joint (860-3C)
120
MiraDRI 860/861 Detail
2" or Less Bellows Expansion Joint (Deck or Wall) (860-3D)
121
MiraDRI 860/861 Detail
2" Inside Corner Expansion Joint (860-3E)
122
MiraDRI 860/861 Detail
Option 1: Flashing at Deck to Curb or Parapet
with CCW MiraDRI 860/861 (860-4A)
123
MiraDRI 860/861 Detail
Option 2: Flashing at Deck to Curb or Parapet
with CCW-703V Liquiseal (860-4B)
124
MiraDRI 860/861 Detail
Double Drain Detail (860-6)
125
MiraDRI 860/861 Detail
Option 1: Pipe and Penetration Flashing
with CCW MiraDRI 860/861 (860-8A)
126
MiraDRI 860/861 Detail
Option 2: Pipe and Penetration Flashing
with CCW 703V Liquiseal (860-8B)
127
MiraDRI 860/861 Detail
Small Penetration (860-8J)
128
MiraDRI 860/861 Detail
Vertical Wall Termination (860-9A)
129
MiraDRI 860/861 Detail
Vertical Wall Termination with Termination Bar (860-9B)
130
MiraDRI 860/861 Detail
Split-Slab Plaza Deck (860-10A)
131
MiraDRI 860/861 Detail
Insulated Plaza Deck (860-10B)
132
MiraDRI 860/861 Detail
Paver Plaza Deck (860-10C)
133
MiraDRI 860/861 Detail
Mortar Bed with Pavers Plaza Deck (860-10D)
134
MiraDRI 860/861 Detail
CCW MiraDRI 860/861 to AVB Tie-In at Brick Ledge (860-11A)
135
MiraDRI 860/861 Detail
Wood Decking Edge Condition (860-12A)
136
MiraDRI 860/861 Detail
Wood Decking Wall Condition (860-12B)
137
MiraDRI 860/861 Detail
Plywood Decks with Thinset Tile (860-12D)
138
MiraDRI 860/861 Detail
Wall/Footing/Outside Corner (860-15A)
139
MiraDRI 860/861 Detail
Option 1: Vertical Wall Outside Corner (860-15B)
140
MiraDRI 860/861 Detail
Option 2: Vertical Wall Outside Corner (860-15C)
141
MiraDRI 860/861 Detail
Overflow Metal Scupper (860-18A)
142
MiraCLAY Bentonite Clay Waterproofing System
Table of Contents
Description ............................................................................................................ 145
Installation Guidelines ...................................................................................... 145
Limitations ............................................................................................................. 145
Accessories........................................................................................................... 145
Coordination ......................................................................................................... 145
Substrate................................................................................................................ 146
Delivery, Storage, and Handling.................................................................... 146
Application ............................................................................................................ 146
Lap and Underslab Installation Instructions............................................ 149
C-1A – Lap Details Under Slab Application ................................................. 149
C-1B – Lap Details Wall Application ........................................................... 150
C-1C.1 – Installation over Gravel Base with MiraDRAIN .............................. 151
C-1C.2 – Installation over Gravel Base without MiraDRAIN......................... 152
Foundation Wall Section Installation Instructions................................. 153
C-2A – Foundation Wall Section................................................................. 153
C-2B – Foundation Wall with Elevated Slab ................................................ 154
C-2C – Foundation Wall with Mat Slab (No Footing) ................................... 155
C-2D – Foundation Wall Section with Insulation ......................................... 156
Construction & Expansion Joint Installation Instructions.................. 157
C-3A – Concrete Slab Pour Joint ................................................................ 157
C-3C – Expansion Joint Less Than ½" (Wall) ............................................. 158
C-3D – CCW MiraCLAY Blindside Expansion Joint...................................... 159
Blindside Application Instructions............................................................... 160
C-5A – Wood Lagging Wall with Soldier Beams ......................................... 160
C-5B – Sheet Piling with Sand Backfill....................................................... 161
C-5C – Sheet Piling with Plywood or MiraDRAIN........................................ 162
C-5D – Concrete Caissons ......................................................................... 163
C-5E – Sheet Piling Step by Step Installation Instructions .......................... 164
Below Grade Applications ............................................................................... 165
C-7A – Foundation Wall to Slab Tie-In ........................................................ 165
C-7C – Hydrostatic Footing/Wall/Floor Detail ............................................. 166
C-7D – Elevator Pit..................................................................................... 167
C-7E – Grade Beam ................................................................................... 168
C-7F – Footing/Wall/Floor ......................................................................... 169
C-7G – Tunnel Detail .................................................................................. 170
Pipe & Penetration Flashing Installation Instructions .......................... 171
C-8 – Positive Side Application Pipe Penetration ........................................ 171
C-8A – Wood Lagging Wall Penetration...................................................... 172
C-8C – Elevator Plunger Penetration .......................................................... 173
Vertical Termination Installation Instructions ..........................................174
C-9A – Sheet Piling Termination..................................................................174
C-9B – Wood Lagging Wall Termination ..................................................... 175
C-9C – Positive Side Application Termination ............................................. 176
143
MiraCLAY Bentonite Clay Waterproofing System
Table of Contents
Specialty Penetration Installation Instructions ...................................... 177
C-14A – Sub Grade Horizontal Penetration ................................................. 177
C-14B – Wall Penetration ........................................................................... 178
C-14C – Shotcrete Soil Nail Tie-Back ......................................................... 179
C-14D – Nelson Stud Condition .................................................................. 180
C-14E – Permanate Tie-Back ..................................................................... 181
C-14F – Pile Cap Detail .............................................................................. 182
C-14G – Sub Grade Horizontal Penetrations ½ Thru Wall ........................... 183
C-14H – Slab Penetrations ......................................................................... 184
Footing Outside Corner Installation Instructions .................................. 185
C-15 – Wall/Footing/Outside Corner Detail ................................................ 185
144
MiraCLAY Bentonite Clay Waterproofing System
DESCRIPTION
CCW MiraCLAY has a uniform layer of sodium bentonite clay that is sandwiched
between a durable puncture-resistant nonwoven polypropylene fabric and a high-
tensile strength woven polypropylene fabric and then needle punched together with
thousands of high-strength denier yarns. These fibers are then thermally fused to the
polypropylene in a proprietary Infrabond™ procedure that locks the sodium bentonite
into place.
CCW MiraCLAY is designed for waterproofing below-grade structural slabs as well as
construction methods incorporating lagging, concrete caisson or shotcrete retention
walls. CCW MiraCLAY is also very effective in rehab waterproofing and zero clearance
property line construction.
(City of Los Angeles Research Report Number 24783)
INSTALLATION GUIDELINES
This application guide has been assembled to assist in the application of CCW Miraclay
and is intended to offer guidance to the construction community. It is intended to be
used in conjunction with current CCW published literature. Other acceptable methods
of application may be incorporated during construction that are not depicted in this
guide provided all applications follow proven and sound construction techniques.
LIMITATIONS
• CCW MiraCLAY membranes should remain dry before and during installation.
• Improper storage could lead to product deterioration.
• Not for use on CMU foundations.
ACCESSORIES
• CCW MiraDRAIN Drainage Composite
• CCW Miraclay Sealant
• CCW Miraclay Granules
• Sure-Seal Termination Bar
COORDINATION
• Pre-construction meeting shall cover all decisions pertaining to design of
waterproofing membrane to achieve a continuous, water-tight building structure.
• Review submittals, surface preparation, installation procedures, special details,
sequence of construction, responsibilities, mock-up requirements, inspection,
testing, protection of membrane, and repair procedures.
• Mock-up shall establish procedures and workmanship that must be maintained
during installation.
• Review adjacent materials such as drains, doors, parapets, penetrations, and
other site conditions for conformance to manufacturer’s application instructions.
145
MiraCLAY Bentonite Clay Waterproofing System
SUBSTRATE
• Ensure all surfaces are installed in accordance with manufacturer specifications.
• Substrate shall be dry, clean, sound, and free of dust, dirt, residue and all other
surface contaminants.
• Verify substrate is flat, free of fins and planar irregularities.
• Substrate systems and the structural performance thereof shall be engineered by
others.
• Prevent the accumulation of water infiltration behind the substrate.
• Unsatisfactory conditions shall be reported and corrected prior to application of
CCW materials.
DELIVERY, STORAGE AND HANDLING
• Deliver CCW materials in original unopened packages.
• Protect CCW materials during transportation, storage, and installation to avoid
physical damage.
• Store CCW materials in a cool dry area protected from direct sunlight and extreme
heat.
• Shelf life is infinite as long as the material is properly stored and protected.
APPLICATION
Underslab Applications
CCW MiraCLAY is designed for use under reinforced concrete slabs 4" (100 mm) thick
or greater on a compacted earth/gravel substrate. If installed over a mud slab, CCW
MiraCLAY requires a minimum 5" (150 mm) thick reinforced concrete slab.
For contaminated site water conditions, as determined by a site water analysis, CCW
MiraCLAY EF should be used. When hydrostatic conditions exist, CCW MiraCLAY should
be installed under footings and grade beams as shown in CCW MiraCLAY details.
Substrate Preparation: NOTE: Do not begin construction in work areas where there
is standing water or in situations which may cause the CCW MiraCLAY to prematurely
hydrate.
Before installing CCW MiraCLAY, the substrate must be properly prepared. Substrate
may be concrete, earth, sand, pea gravel or crushed stone. Earth and sand substrates
should be compacted to a minimum 85% Modified Proctor density. Crushed stone
should not be larger than ¾" (18 mm) in size. Honeycombing, voids and aggregate
pockets exceeding 1" in diameter or have a depth greater than ¾ inch should be filled
with a non-shrink cementitious grout. Fill tie-rod holes with a non-shrink cementitious
grout. Substrate should be smooth and uniform without sharp projections or pockets.
Complete all required elevator pit, sump pit and grade beam and piling work before
installing CCW MiraCLAY under main slab area.
Installation: Install CCW MiraCLAY over the properly prepared substrate with the non-
woven geotextile side up. Overlap adjoining edges a minimum of 4" (100 mm); stagger
sheet ends a minimum of 24" (600 mm); and nail or staple edges together as required
to prevent any displacement during concrete placement. CCW MiraCLAY Granules may
also be placed in the seam for additional waterproofing performance.
146
MiraCLAY Bentonite Clay Waterproofing System
When the slab is poured in sections, CCW MiraCLAY should extend a minimum 12"
(300 mm) beyond the slab edge. When the installation reaches the outer edge of the
slab, continue CCW MiraCLAY up and out of the form a minimum of 12" (300 mm). At
the corner, CCW MiraCLAY should remain in contact with the substrate and inside the
surface of the concrete form. When the form is removed, the CCW MiraCLAY outside
the form should be positioned and fastened onto the footing or vertical wall. Overlay the
CCW MiraCLAY a minimum of 6" (150 mm) with the succeeding vertical waterproofing
membrane.
At property line retaining walls, such as soldier pile or lagging, continue the underslab
CCW MiraCLAY application up the retaining wall a minimum 12" (300 mm) above
the top edge of the slab or footing and secure. Overlap the vertical CCW MiraCLAY
waterproofing membrane by a minimum of 6" (150 mm) or a minimum of 12" (300
mm) under hydrostatic head conditions.
Property Line/ Lagging Application
Substrate Preparation: Gaps between the wood lagging greater than 1" (25 mm) must
be filled with cementitious grout. In areas with large gaps (1" to 5" / 25 mm to 125
mm) between lagging, install plywood to provide a uniform substrate. Where drainage
issues may arise, install CCW MiraDRAIN to provide a uniform substrate as well as to
facilitate drainage.
Installation: Install CCW MiraCLAY with the white non-woven side facing the installer.
Secure the CCW MiraCLAY into position with fasteners and 1" (25 mm) washers. Use
the appropriate fasteners for the type of substrate used to receive the CCW MiraCLAY.
Install succeeding courses of CCW MiraCLAY by overlapping the previous course a
minimum of 4" (100 mm). Stagger the seams a minimum of 24" (600 mm). Install
in shingle fashion so that the upper roll of CCW MiraCLAY overlaps the lower roll.
Fasten membrane once every 18" (45 cm) on seams or as required to prevent blousing.
Shotcrete installations require a seam fastening pattern not to exceed 12" O.C. or as
necessary to prevent seam blousing.
Extend waterproofing membrane to 6" below grade and fasten membrane to the
substrate to maintain constant compression using a 1/8" x 1" (3 x 25 mm) minimum
termination bar. Embed the top edge of CCW MiraCLAY and termination bar with a thick
bead of CCW MiraCLAY Sealant 2" (50 mm) wide by ½" (12 mm) thick.
Standard Foundation Walls
Substrate Preparation: The substrate must be properly prepared to receive the
CCW MiraCLAY waterproofing membrane. All honeycombs, form-tie cavities and
indentations should be filled with CCW MiraCLAY Sealant or filled with latex Portland
Cement. Substrate must be smooth and uniform removing any protrusions over ½"
(12 mm) from the surface. Footings must be free of soil, rocks or debris to provide a
suitable substrate to receive the CCW MiraCLAY waterproofing membrane.
147
MiraCLAY Bentonite Clay Waterproofing System
Installation: The CCW MiraCLAY waterproofing membrane should be installed with the
white non-woven side facing the applicator. Create a cant at any vertical to horizontal
transition by applying a 1-½" (39 mm) to 2" (50 mm) of CCW MiraCLAY Granules or
CCW MiraCLAY Sealant along that junction. At the base of the foundation wall where
the vertical wall meets the horizontal footing, install CCW MiraCLAY in a horizontal
manner extending out onto the footing a minimum of 12" (300 mm). Fasten the CCW
MiraCLAY in place with concrete fasteners and 1" (25 mm) washers. Install succeeding
courses of CCW MiraCLAY by overlapping the previous course a minimum of 4" (100
mm). Stagger the seams a minimum of 12" (300 mm). Install in shingle fashion so
that the upper roll of CCW MiraCLAY overlaps the lower roll. Fasten membrane once
every 18" (45 cm) to 3' (90 cm) on seams or as required to prevent blousing. At grade
line, terminate CCW MiraCLAY with a rigid termination bar or fasten 12" (300 mm) on
center. Embed the top edge of CCW MiraCLAY and termination bar with a thick bead
of CCW MiraCLAY sealant 2" (50 mm) wide by ½" (12 mm) thick. Backfill must be
compactible soils free of construction debris and must be uniformly compacted to a
minimum 85% Modified Proctor on each lift.
Protection: The membrane must be protected from damage by future operations,
other trades, and pre-hydration prior to backfill. The applicator shall install protection
material applicable to jobsite conditions, to protect the membrane. Protection course
must be CCW MiraDRAIN products that correspond to horizontal or vertical applications.
148
MiraCLAY Detail
Lap Details Under Slab Application (C-1A)
149
MiraCLAY Detail
Lap Details Wall Application (C-1B)
150
MiraCLAY Detail
Installation over Gravel Base with MiraDRAIN (C-1C.1)
151
MiraCLAY Detail
Installation over Gravel Base without MiraDRAIN (C-1C.2)
152
MiraCLAY Detail
Foundation Wall Section (C-2A)
153
MiraCLAY Detail
Foundation Wall with Elevated Slab (C-2B)
154
MiraCLAY Detail
Foundation Wall with Mat Slab (No Footing) (C-2C)
155
MiraCLAY Detail
Foundation Wall Section with Insulation (C-2D)
156
MiraCLAY Detail
Concrete Slab Pour Joint (C-3A)
157
MiraCLAY Detail
Expansion Joint Less Than ½" (Wall) (C-3C)
158
MiraCLAY Detail
CCW MiraCLAY Blindside Expansion Joint (C-3D)
159
MiraCLAY Detail
Wood Lagging Wall with Soldier Beams (C-5A)
160
MiraCLAY Detail
Sheet Piling (C-5B)
161
MiraCLAY Detail
Sheet Piling with Plywood or MiraDRAIN (C-5C)
162
MiraCLAY Detail
Concrete Caissons (C-5D)
163
MiraCLAY Detail
Sheet Piling Step By Step Installation Instructions (C-5E)
164
MiraCLAY Detail
Foundation Wall to Slab Tie-In (C-7A)
165
MiraCLAY Detail
Hydrostatic Footing/Wall/Floor Detail (C-7C)
166
MiraCLAY Detail
Elevator Pit (C-7D)
167
MiraCLAY Detail
Grade Beam (C-7E)
168
MiraCLAY Detail
Footing/Wall/Floor (C-7F)
169
MiraCLAY Detail
Tunnel Detail (C-7G)
170
MiraCLAY Detail
Positive Side Application Pipe Penetration (C-8)
171
MiraCLAY Detail
Wood Lagging Wall Penetration (C-8A)
172
MiraCLAY Detail
Elevator Plunger Penetration (C-8C)
173
MiraCLAY Detail
Sheet Piling Termination (C-9A)
174
MiraCLAY Detail
Wood Lagging Wall Termination (C-9B)
175
MiraCLAY Detail
Positive Side Application Termination (C-9C)
176
MiraCLAY Detail
Sub Grade Horizontal Penetration (C-14A)
177
MiraCLAY Detail
Wall Penetration (C-14B)
178
MiraCLAY Detail
Shotcrete Soil Nail Tie-Back (C-14C)
179
MiraCLAY Detail
Nelson Stud Condition (C-14D)
180
MiraCLAY Detail
Permanate Tie-Back (C-14E)
181
MiraCLAY Detail
Pile Cap Detail (C-14F)
182
MiraCLAY Detail
Sub Grade Horizontal Penetrations ½ Thru Wall (C-14G)
183
MiraCLAY Detail
Slab Penetrations (C-14H)
184
MiraCLAY Detail
Wall/Footing/Outside Corner Detail (C-15)
185
Water-Based Asphalt Emulsion
Barricoat-S/R Waterproofing System for Vertical Walls
Table of Contents
Description ............................................................................................................ 187
Installation Guidelines ...................................................................................... 187
Limitations ............................................................................................................. 187
Accessories........................................................................................................... 188
Coordination ......................................................................................................... 188
Substrate................................................................................................................ 188
Delivery, Storage, and Handling.................................................................... 188
Application ............................................................................................................ 189
Crack Treatment Installation Instructions ................................................ 193
BC-1A – Non-Moving Cracks Less Than 1/16" ............................................. 193
BC-1B – Construction Joints or Moving Cracks Greater Than 1/16".............. 194
Foundation Wall Section Installation Instructions................................. 195
BC-2A – Footing Cross Section .................................................................. 195
BC-2B – Elevated Floor Slab Footing Cross Section ................................... 196
BC-2C – Footing Cross Section with Insulation .......................................... 197
Expansion Joint Installation Instructions ................................................. 198
BC-3A – Option 1: Expansion Joints Less Than ½" with Barricoat-R......... 198
BC-3B – Option 2: Expansion Joint Less Than ½" with Sheet Membrane .. 199
BC-3C – Expansion Joints Over 2" with EJ-500 ........................................200
Pipe & Penetration Flashing Installation Instructions .......................... 201
BC-8A – Option 1: Pipe & Penetration with Barricoat-R............................. 201
BC-8B – Option 2: Pipe & Penetration with MiraDRI 860/861 ................... 202
Vertical Termination Installation Instructions .........................................203
BC-9A – Vertical Wall Termination ............................................................. 203
Inside/Outside Corners and Angle Changes
Installation Instructions ...................................................................................204
BC-15A – Option 1: Inside/Outside Corners
and Angle Changes with Barricoat-R..........................................................204
BC-15B – Option 2: Inside/Outside Corners
and Angle Changes with MiraDRI 860/861 ................................................ 205
186
Water-Based Asphalt Emulsion
Barricoat-S/R Waterproofing System for Vertical Walls
DESCRIPTION
Barricoat-S: A water-based asphalt emulsion modified with a blend of synthetic
polymers and special additives. Barricoat-S is dispensed in tandem with CCW
Barricure, a non-corrosive, chloride-free deliquescent salt solution. Barricoat-S and
Barricure are applied through specialized co-spray equipment, which is provided by
others and approved by CCW. During spray, Barricoat-S rapidly becomes firm, tack-
free and water-resistant. Product air dries to its final cured state, which is a rubber-like,
fully adhered membrane.
Barricoat-S is a waterproofing and vapor barrier membrane for use in below-grade
foundation wall assemblies. Barricoat-S is for use on primarily-vertical surfaces and
can be applied directly to concrete, concrete masonry, polystyrene foam insulation
board and many other common building materials. Barricoat-S waterproofing and
MiraDRAIN® drainage composite are combined for a complete, warranted foundation
waterproofing system by CCW.
Barricoat-R: A water-based asphalt emulsion modified with a blend of synthetic
rubbers and special additives. Barricoat-R is formulated to a thick consistency, so it
will hang easily on vertical surfaces at high thickness. Barricoat-R is applied by roller
or brush, and air-dries to a rubber-like consistency.
Barricoat-R is often used as an accessory product in the Barricoat-S Spray-Applied
Waterproofing system. Barricoat-R can also be used as the primary membrane, and
by itself performs as a waterproofing membrane and vapor barrier. Barricoat-R is
for use on below-grade, vertical surfaces and can be applied directly to concrete,
concrete masonry, polystyrene foam insulation board and many other common building
materials. Barricoat-R plus MiraDRAIN® drainage composite are combined to form a
complete, warranted foundation waterproofing system by CCW.
INSTALLATION GUIDELINES
This application guide has been assembled to assist in the application of CCW Barricoat
and is intended to offer guidance to the construction community. It is intended to be
used in conjunction with current CCW published literature. Other acceptable methods
of application may be incorporated during construction that are not depicted in this
guide provided all applications follow proven and sound construction techniques.
LIMITATIONS
• Do not apply during rain or snow, or if precipitation is expected in next 16 hours.
• Do not apply Barricoat-R if temperature is expected to drop below 32°F in the
next 16 hours.
• Protect from freezing during delivery, storage, and handling.
• Not intended for permanent exposure. Cover within 30 days of application.
• Not compatible with silicone, coal tar, polysulfide or plasticized PVC.
• Do not apply solvent-based products over Barricoat-S/R.
• Not for use in plaza deck, planter, pond liner or other horizontal waterproofing
applications.
• Not for use as a negative-side waterproofing membrane.
187
Water-Based Asphalt Emulsion
Barricoat-S/R Waterproofing System for Vertical Walls
ACCESSORIES
• CCW DCH Reinforcing Fabric
• CCW LiquiFiber
• CCW MiraDRI 860/861
• CCW Protection Board V
• CCW Protection Board H
• CCW Protection Board HS
• CCW 300HV Protection Fabric
• CCW MiraDRAIN Drainage Composite
• CCW-201 Sealant
COORDINATION
• Pre-construction meeting shall cover all decisions pertaining to design of
waterproofing membrane to achieve a continuous, water-tight building structure.
• Review submittals, surface preparation, installation procedures, special details,
sequence of construction, responsibilities, mock-up requirements, inspection,
testing, protection of membrane, and repair procedures.
• Mock-up shall establish procedures and workmanship that must be maintained
during installation.
• Review adjacent materials such as drains, doors, parapets, penetrations, and
other site conditions for conformance to manufacturer’s application instructions.
SUBSTRATE
• Ensure all surfaces are installed in accordance with manufacturer specifications.
• Substrate shall be dry, clean, sound, and free of dust, dirt, residue and all other
surface contaminants.
• Verify substrate is flat, free of fins and planar irregularities.
• Substrate systems and the structural performance thereof shall be engineered by
others.
• Prevent the accumulation of water infiltration behind the substrate.
• Unsatisfactory conditions shall be reported and corrected prior to application of
CCW materials.
DELIVERY, STORAGE AND HANDLING
• Deliver CCW materials in original unopened packages.
• Protect CCW materials during transportation, storage, and installation to avoid
physical damage.
• Store CCW materials in a cool dry area protected from direct sunlight and extreme
heat.
• Store product and accessories in area protected from direct sunlight and
precipitation, and away from open flames, sparks or welding. Store flammable
materials in compliance with federal, state and local regulations. Store pails of
Barricoat-S/R in an area maintained between 50°F and 90°F.
188
Water-Based Asphalt Emulsion
Barricoat-S/R Waterproofing System for Vertical Walls
APPLICATION
Surface Preparation: Concrete shall be cured in place for 3 days minimum. Verify
that surfaces are free of visible surface moisture, loose materials, release oils and
other contaminants. These shall be removed prior to application by power washing
or other suitable method. Fill form tie holes, honeycomb and voids with non-shrink
grout or CCW-703 V Liquiseal. Barricoat-R may be used to fill voids and irregularities
that do not exceed ¼" depth. Grind fins and similar protrusions flush. On concrete
masonry unit (CMU) construction, mortar joints shall be free of voids and struck flush
and mortar droppings shall be removed from surfaces.
Detail Work: Clean joints and saw cut cracks. All moving cracks over 1/16" wide and
all expansion joints less than 1" wide shall be cleaned, primed, fitted with a backing
rod and caulked with CCW-201 non-sag polyurethane sealant. Refer to CCW-201
data sheet for information on the use of this product. For larger joints, contact CCW
representative.
Apply a 1", 45° angle cant of CCW-201 sealant at the juncture of all vertical and
horizontal surfaces including at pipes, vents and other projections.
Apply a bond breaker tape over the Sealant installed in expansion joints. Width of bond
breaker shall be three times joint width.
Installing CCW-201 & CCW-703V Liquiseal
Apply according to instructions on product data sheet. Allow sealant to cure fully before
covering with Barricoat-R or MiraDRI 860/861 Strips.
Installing Barricoat-R & DCH Reinforcing Fabric
Apply approximately 30 wet mils of Barricoat-R to the substrate with a brush or roller.
Immediately set DCH Reinforcing Fabric into Barricoat-R, pressing the fabric into the
liquid while smoothing wrinkles with a brush or drywall knife. Lap neighboring pieces
of DCH Reinforcing Fabric 2" minimum, and apply Barricoat-R into laps. Immediately
cover fabric with a 2nd coat of Barricoat-R, encapsulating it. When the substrate
temperature is 32°F or lower, or the ambient temperature is below 50°F, spray the top
coat of Barricoat-R with Barricure solution, dispensed either from the co-spray gun
with Barricoat-S turned off, or from a garden sprayer. Allow the detail to dry firm before
spraying over with Barricoat-S.
Installation of MiraDRI 860/861 Strips
When the ambient or substrate temperature is below 40°F, use MiraDRI 861 and follow
the cold weather installation procedure indicated on the product data sheet. Prepare the
surface with CCW-702 WB or CCW-702/702 LV, following the instructions on product
data sheet. Apply CCW-715 to damp or green concrete surfaces. Apply the contact
adhesive over enough area that it extends 1" minimum beyond the edge of the installed
self-adhering membrane. Cut manageable-sized pieces of self-adhering membrane
from the roll using a sharp knife, making square, clean cuts. Lap neighboring pieces
5" minimum and sequence the installation to provide shingled laps. Press the self-
adhering membrane firmly to the substrate with a hand roller tool, especially at edges
and laps. Seal over laps and cuts and around penetrating hardware with LM-800XL
Mastic.
189
Water-Based Asphalt Emulsion
Barricoat-S/R Waterproofing System for Vertical Walls
190
Water-Based Asphalt Emulsion
Barricoat-S/R Waterproofing System for Vertical Walls
leakage and adhesion testing. Drying time varies with substrate, ambient temperature
and humidity. Membrane is dry when it appears black and rubber-like, and feels dry
when pressed. Install MiraDRAIN drainage composite, Protection Board V or insulation
board by others over the Barricoat-S membrane before backfill.
Spraying of Barricoat-S in Cold Weather
If the ambient or substrate temperature is 32°F or lower, incorporate these modifications
to the standard procedure: Spray Barricoat-S in two coats at 35–40 wet mils each,
allowing drying between coats. Keep drums of Barricoat-S and the spray equipment
in an area maintained at or above 50°F, and keep the hose and gun reeled in except
during spray.
Spraying of Barricoat-S on Aerated Concrete, Green Concrete, or Concrete Containing
Additives that Cause Out Gassing
If Barricoat-S tends to blister shortly after spray on the concrete substrate, incorporate
these modifications to the standard procedure: Spray the surface with approximately
10 mils wet of Barricoat-S, with the Barricure stream shut off. Allow this “primer coat”
of Barricoat-S to dry firm, then apply Barricoat-S co-sprayed with Barricure according
to the standard procedure or the cold weather procedure.
Spray Tip Recommendations:
Barricoat-S High Coverage GHD 635
Detail Coat GHD 419
Barricure Graco XHD 627 OR TP 6501-SS
Applying Barricoat-R
Obtain full, safe access to area, and mask adjacent surfaces to protect from droppings
or splatter. Use a medium/long nap roller to cover open surfaces and a brush or a detail
roller to cover details. With roller application, apply three coats at 30 mils wet thickness
each. Allow the previous coat to dry firm before applying the next. Total dry membrane
thickness after full cure shall measure a minimum of 60 mils. In areas treated with DCH
Reinforcing Fabric encapsulated in Barricoat-R, allow details to dry firm, and cover
with minimum 30 mils wet of Barricoat-R. Provide complete coverage over surfaces,
so that there are no voids, pinholes or similar passages through membrane. Allow
membrane to dry completely before subjecting to inspection for water leakage and
adhesion testing. Drying time varies with substrate, ambient temperature and humidity.
Membrane is dry when it appears black and rubber-like, and feels dry when pressed.
Install MiraDRAIN drainage composite, Protection Board V, H, HS, insulation board by
others, or Protection Fabric 200V or 300 HV over the Barricoat-R membrane before
backfill.
Protection Course
Installing MiraDRAIN over Barricoat-S/R
Allow Barricoat-S/R membrane to dry completely. Spray CAV-GRIP adhesive over the
surface of Barricoat-S/R, and press MiraDRAIN in place. Install MiraDRAIN, MiraDRAIN
– HC, and HC Connectors in accordance with the MiraDRAIN Installation Guide.
191
Water-Based Asphalt Emulsion
Barricoat-S/R Waterproofing System for Vertical Walls
192
Barricoat-S/R Detail
Non-Moving Cracks Less Than 1/16" (BC-1A)
193
Barricoat-S/R Detail
Construction Joints or Moving Cracks Greater Than 1/16" (BC-1B)
194
Barricoat-S/R Detail
Footing Cross Section (BC-2A)
195
Barricoat-S/R Detail
Elevated Floor Slab Footing Cross Section (BC-2B)
196
Barricoat-S/R Detail
Footing Cross Section with Insulation (BC-2C)
197
Barricoat-S/R Detail
Option 1: Expansion Joints Less Than ½" with Barricoat-R (BC-3A)
198
Barricoat-S/R Detail
Option 2: Expansion Joint Less Than ½" with Sheet Membrane (BC-3B)
199
Barricoat-S/R Detail
Expansion Joints Over 2” with EJ-500 (BC-3C)
200
Barricoat-S/R Detail
Option 1: Wall Pipe and Penetration with Barricoat-R (BC-8A)
201
Barricoat-S/R Detail
Option 2: Wall Pipe and Penetration with MiraDRI 860/861 (BC-8B)
202
Barricoat-S/R Detail
Vertical Wall Termination (BC-9A)
203
Barricoat-S/R Detail
Option 1: Inside/Outside Corners with Barricoat-R (BC-15A)
204
Barricoat-S/R Detail
Option 2: Inside/Outside Corners with MiraDRI 860/861 (BC-15B)
205
MiraDRAIN Drainage Composite
Table of Contents
CCW MiraDRAIN Application Guide ............................................................ 207
CCW MiraDRAIN Matrix ................................................................................... 224
Cut Soil Installation Instructions .................................................................. 227
MD-1B – Cut Soil Installation ..................................................................... 227
MD-1C – Retaining Wall Detail ................................................................... 228
Chimney Drain Installation Instructions ....................................................229
MD-2 – Chimney Drain ..............................................................................229
Cutoff Drain Installation Instructions ..........................................................230
MD-4 – Cutoff Drain .................................................................................. 230
Underslab Total Application Installation Instructions.......................... 231
MD-6 – Under Slab Total Application ......................................................... 231
MiraDRAIN HC Cutoff Drain/Road Edge
Installation Instructions ...................................................................................232
MD-7 – MiraDRAIN HC Cutoff Drain/Road Edge ......................................... 232
Panel Installation Instructions.......................................................................233
MS-8 – Panel Termination ......................................................................... 233
Wall Panel Connection Installation Instructions ....................................234
MS-9A – Wall Panel Connection.................................................................234
Vertical Termination Installation Instructions .........................................235
MS-10A – MiraDRAIN Splice ...................................................................... 235
MiraDRAIN HC Accessories ...........................................................................236
MiraDRAIN HC End-Out Connector.............................................................236
HC-5A – MiraDRAIN HC End-Out Connector .............................................. 236
MiraDRAIN HC Drainage Connector ........................................................... 237
HC-5B – MiraDRAIN HC Drainage Connector ............................................. 237
MiraDRAIN HC Sideout Connectors............................................................238
HC-5C – MiraDRAIN HC Sideout Connectors.............................................. 238
MiraDRAIN HC Sideout Connector Installation ......................................239
HC-7B – MiraDRAIN HC Sideout Connector Installation .............................. 239
206
MiraDRAIN Drainage Composite
APPLICATION GUIDE
CCW MiraDRAIN prefabricated drainage panels may be installed in a variety of
construction applications including: retaining walls, foundation walls (both waterproofed
and non-waterproofed), lagging systems, split slabs, plaza decks, planters, buttress/
landfills, interceptor/edge drains and greenroofs. MiraDRAIN can be cut with a utility
knife or scissors. Slurries, shotcrete or concrete may be placed directly to either side
of the panels. The panels should terminate at the top of the footing and are flexible
enough to form a right angle to cover the top of the footing. MiraDRAIN eliminates
the need for a protection course over most waterproofing systems. Native soils can
be used over MiraDRAIN. Contact your local MiraDRAIN representative for specific
guidelines.
FOUNDATION WALLS - VERTICAL APPLICATIONS
MiraDRAIN panels can be installed in rows or columns with the fabric side toward the
soil. Each method has its advantages depending on the criteria of the project.
Installing MiraDRAIN in Columns
1. Start at the low point of the wall and attach the panel to the wall with approved
CCW adhesive.
2. Attach adjacent panels together by:
207
MiraDRAIN Drainage Composite
208
MiraDRAIN Drainage Composite
209
MiraDRAIN Drainage Composite
Planter
1. Place the MiraDRAIN in the planter so that the fabric on the vertical and horizontal
surfaces face the soil.
2. Utilize the installation procedures and attachment method appropriate for the type
of substrate.
3. Overlap the fabric of the vertical panel onto the horizontal panel at the transition
point.
4. If the panels require cutting, exposed cuts must be covered with supplemental
pieces of filter fabric to prevent soil intrusion. A minimum 6" (150 mm) piece of
filter fabric will be required to cover cut sections.
210
MiraDRAIN Drainage Composite
Plaza
1. Place fabric side up over a properly waterproofed substrate.
2. The panels should be placed in shingle fashion so that water runs with the
overlap. Secure MiraDRAIN to the waterproofing membrane with ballast or
approved CCW adhesive to hold it in place. The first panels should be placed with
the flanged edge uphill.
3. Termination edges that have been cut will require a supplemental piece of filter
fabric to seal the panel from soil intrusion.
ATTACHMENT METHODS
No Waterproofing Membrane
MiraDRAIN should be attached to non-waterproofed walls with approved CCW
adhesive, concrete nails with 1" diameter washers. MiraDRAIN will be permanently
secured upon completion of backfill. Backfill within two weeks. Backfill to at least 6"
(150 mm) above the top edge of MiraDRAIN.
Using CCW MiraDRI 860/861, CCW 500R, CCW 525, Barricoat, MiraSEAL, MiraPLY,
Sure-Seal EPDM & CCW 703 Waterproofing Membranes
1. Place the MiraDRAIN in the planter so that the fabric on the vertical and horizontal
surfaces face the soil.
2. Utilize the installation procedures and attachment method appropriate for the type
of substrate.
3. Overlap the fabric of the vertical panel onto the horizontal panel at the transition
point.
4. If the panels require cutting, exposed cuts must be covered with supplemental
pieces of filter fabric to prevent soil intrusion. A minimum 6" (150 mm) piece of
filter fabric will be required to cover cut sections.
211
MiraDRAIN Drainage Composite
212
MiraDRAIN Drainage Composite
6" & 12" HC Endout Connectors 6" & 12" HC Sideout Connectors
213
MiraDRAIN Drainage Composite
A B
A B
A B
215
MiraDRAIN Drainage Composite
DRAINAGE SOLUTIONS
Plaza Decks
Problem: Water seeping into intermediate
levels of the building, damaging the structure
and contents below.
Solution: CCW MiraDRAIN 9000
Options: CCW MiraDRAIN 8000, 9800, 9900
216
MiraDRAIN Drainage Composite
Shoring/Lagging
Problem: Site water removal; consistent
drainage path at property line walls.
Solution: CCW MiraDRAIN 6000XL, 6200XL
Options: CCW MiraDRAIN 6000, 6200, 9800
217
MiraDRAIN Drainage Composite
Foundation Walls
Problem: Excessive pressure buildup from
saturated backfill may cause structural
damage; constant hydrostatic head pressure
may cause premature failure of waterproofing
membrane.
Solution: CCW MiraDRAIN 6000XL, 6200XL
Options: CCW MiraDRAIN 2000, 6000, 6200,
8000, 9800
218
MiraDRAIN Drainage Composite
Retaining Walls
Problem: Increased earth stresses created by
undrained backfill, resulting in unacceptable
movement of retaining walls.
Solution: CCW MiraDRAIN 6000XL, 6200XL
Options: CCW MiraDRAIN 2000,
6000, 6200, 9800
219
MiraDRAIN Drainage Composite
220
MiraDRAIN Drainage Composite
Underground Structures
Problem: Water seepage that could lead to
structural and interior tunnel damage.
Solution: CCW MiraDRAIN 6000XL, 6200XL
Options: CCW MiraDRAIN 6000, 6200, 9800
221
MiraDRAIN Drainage Composite
Trench Drains
Problem: Removing excessive storm water
in natural and artificial depressions; seeping
water that can cause erosion along slopes.
Solution: CCW MiraDRAIN HC
222
MiraDRAIN Drainage Composite
Planters
Problem: Specifying and designing an efficient
drainage system for a planter in which constant
irrigation requires a reliable drainage medium.
Solution: CCW MiraDRAIN 9800
Options: CCW MiraDRAIN 9000, 6000, 6200,
6000XL, 6200XL
223
MiraDRAIN Drainage Composite
Fabric
Fabric
Installed Installed Fabric Apparent Compressive
Product Description Core Fabric Water Thickness
Vertical Horizontal Description Opening Strength
Flow Rate
Size*
MiraDRAIN Intermediate-flow, 8.5 gpm/ft. X Polystyrene 140NC nonwoven filter 70 Sieve 140 gpm/ft2 0.25" 10,800 psi
2000 low compressive- fabric
strength, shallow
depths not
exceeding 10 feet
MiraDRAIN Intermediate-flow, 8.5 gpm/ft. X Polystyrene 160N nonwoven filter 70 Sieve 110 gpm/ft2 0.25" 10,800 psi
2000DT low compressive- fabric meeting
strength, shallow AASHTO
depths not M288-06
exceeding 10 feet;
DOT Projects
MiraDRAIN High-flow, high- 12.5 gpm/ft. X Polystyrene DCN04 nonwoven filter 40 Sieve 200 gpm/ft2 0.40" 15,000 psi
6000 compressive fabric
strength
MiraDRAIN High-flow, high- 12.5 gpm/ft. X Polystyrene 160N nonwoven filter 70 Sieve 110 gpm/ft2 0.40" 15,000 psi
6000DT compressive fabric meeting
strength, DOT AASHTO
Projects M288-06
*AOS (Apparent Opening Size) - A higher Percent Opening Area will be less susceptible to long-term clogging.
224
MiraDRAIN Drainage Composite
Fabric
Fabric
Installed Installed Fabric Apparent Compressive
Product Description Core Fabric Water Thickness
Vertical Horizontal Description Opening Strength
Flow Rate
Size*
MiraDRAIN High-flow, high- 14.5 gpm/ft. X Polystyrene 160N nonwoven filter 70 Sieve 110 gpm/ft2 0.40" 16,500 psi
6000XL compressive fabric meeting
strength, can AASHTO
be installed M288-06
Horizontally in
planters
MiraDRAIN High-flow, high- 12.5 gpm/ft. X Polystyrene DCN04 nonwoven filter 40 Sieve 200 gpm/ft2 0.40" 15,000 psi
6200 compressive fabric
strength, Polymeric
Sheet - prevents
die-cutting of
waterproofing
membrane
MiraDRAIN high-flow, high- 14.5 gpm/ft. X Polystyrene 160N nonwoven filter 70 Sieve 110 gpm/ft2 0.40" 16,500 psi
6200XL compressive fabric meeting
strength, can AASHTO
be installed M288-06
Horizontally in
planters, Polymeric
Sheet - prevents
die-cutting of
waterproofing
225
membrane
*AOS (Apparent Opening Size) - A higher Percent Opening Area will be less susceptible to long-term clogging.
MiraDRAIN Drainage Composite
Fabric
Fabric
Installed Installed Fabric Apparent Compressive
Product Description Core Fabric Water Thickness
Vertical Horizontal Description Opening Strength
Flow Rate
Size*
MiraDRAIN High-performance, X 21 gpm/ft. Polypropelene FW402 monofilament 40 Sieve 145 gpm/ft2 0.40" 21,000 psi
8000-P chemical resistant woven filter
fabric
MiraDRAIN High-performance, 21 gpm/ft. 3.8 gpm/ft. Polystyrene FW402 monofilament 40 Sieve 145 gpm/ft2 0.40" 18,000 psi
9000 high-strength woven filter
fabric
MiraDRAIN High-performance, 15.5 gpm/ft. 3.8 gpm/ft. Polystyrene 180N heavy-weight, 80 Sieve 95 gpm/ft2 0.40" 18,000 psi
9800 high-strength nonwoven filter
fabric
MiraDRAIN High- X 2.4 gpm/ft. Polystyrene FW402 monofilament 40 Sieve 365 gpm/ft2 0.25" 33,000 psi
9900 performance, very woven filter
high-compressive fabric
strength
MiraDRAIN High-flow, 21 gpm/ft. X Polystyrene 140NC nonwoven 70 Sieve 140 gpm/ft 2 1" 9,500 psi
HC foundation or filter fabric
edge drain
MiraDRAIN Horizontal green X 21 gpm/ft. Polystyrene GR300 moisture 100 Sieve 75 gpm/ft2 1" 9,500 psi
GR9400 roof applications retention filter
with moisture medium
226
retention mat
fabric
*AOS (Apparent Opening Size) - A higher Percent Opening Area will be less susceptible to long-term clogging.
MiraDRAIN Drainage Composite System Detail
Cut Soil Installation (MD-1B)
227
MiraDRAIN Drainage Composite System Detail
Retaining Wall Detail (MD-1C)
228
MiraDRAIN Drainage Composite System Detail
Chimney Drain (MD-2)
229
MiraDRAIN Drainage Composite System Detail
Cutoff Drain (MD-4)
230
MiraDRAIN Drainage Composite System Detail
Under Slab Total Application (MD-6)
231
MiraDRAIN Drainage Composite System Detail
MiraDRAIN HC Cutoff Drain/Road Edge Details (MD-7)
232
MiraDRAIN Drainage Composite System Detail
Panel Termination (MD-8)
233
MiraDRAIN Drainage Composite System Detail
Wall Panel Connection (MS-9A)
234
MiraDRAIN Drainage Composite System Detail
MiraDRAIN Splice (MS-10A)
235
MiraDRAIN HC Accessory Detail
MiraDRAIN HC End-Out Connector (HC-5A)
236
MiraDRAIN HC Accessory Detail
MiraDRAIN HC Drainage Connector (HC-5B)
237
MiraDRAIN HC Accessory Detail
MiraDRAIN HC Sideout Connectors (MD-5C)
238
MiraDRAIN HC Accessory Detail
MiraDRAIN HC Sideout Connector Installation (MD-7B)
239
Tie-Back Cover
Table of Contents
Tie-Back Cover Details ..................................................................................... 242
Square Tie-Back Cover .............................................................................. 242
240
Tie-Back Cover Detail
Square Tie-Back Cover
241
Technical Bulletins
Table of Contents
CCW Waterproofing Membranes Installed over Concrete Curing
Agents, Form Release Agents, and Concrete Hardeners ................... 243
CCW Product Line Shelf Life ..........................................................................244
Rubber Mat Test for Moisture Content of Concrete ............................. 246
CCW MiraDRI 860/861 Sheet Membrane Application
Guide For Use With EPS Forming Systems .............................................. 247
Application of CCW MiraDRI 860/861 on Plywood Decks ..................248
242
Technical Bulletins
CCW WATERPROOFING MEMBRANES INSTALLED OVER
CONCRETE CURING AGENTS, FORM RELEASE AGENTS,
AND CONCRETE HARDENERS
Carlisle Coatings & Waterproofing does not approve or disapprove of any specific
curing agents, form release agents, or concrete hardeners. However, we do have some
guidelines below that you can follow to aid in the selection of agents and the use of
them with a CCW-Membrane.
When the substrate is to receive a CCW Waterproofing System it is recommended that
chemical additives are not used. Where chemical additives are used, CCW recommends
a clear resin-based material without silicones, waxes, oils, or pigments. The majority
of agents will require removal including the ones mentioned and the self-dissipating
formulas. Prior to installing a CCW-Membrane the substrate must have no residues
from the agents. Any remaining residue left on the substrate must be removed by
using the directions of the agent’s manufacturer. These directions are commonly listed
on their Product Data Sheets or you can contact their Technical Service Department.
Typically the agents can be removed by mechanical abrasion or hydro-blasting (power-
washing) prior to the installation of a CCW Waterproofing Membrane. After the agent
has been removed a field adhesion test is always recommended to ensure that the
proper adhesion has been achieved which is standard industry practice regardless if
an agent was used or not.
Carlisle does not recommend using any type of concrete hardener prior to the
installation of a CCW-Membrane. The hardeners will seal the pores of the concrete too
tightly which will not allow for a mechanical bond of the CCW-Primer/Membrane. If a
hardener has been used on the substrate the surface will require mechanical abrasion
such as scarifying or mechanical abrasion. The surface must be rough and course
enough to allow for a mechanical bond of the CCW-Primer/Membrane.
243
Technical Bulletins
CCW PRODUCT LINE SHELF LIFE
The following is a list of the minimum shelf life for Carlisle Coatings & Waterproofing’s
product line. Shelf life is based on the date of manufacture and is referenced on batch
code that can be found on the label or a grocery sticker placed on the product. In many
cases, if properly handled and stored, product will remain usable for application for a
time period beyond the minimum shelf life. Since many batch codes are structured
differently, please contact either CCW Customer Service or Technical Service for
specific batch code interpretation.
All products must be stored in accordance with CCW requirements and improper
handling and storage will adversely affect product quality and workability.
6 Months:
• CCW Miraseal
• CCW Uncured Neoprene Flashing
9 Months:
• CCW Barricoat-S
• CCW Barriseal-S
244
Technical Bulletins
2 Years (24 Months):
• CCW 500
• CCW MiraDRAIN
• CCW MiraSTOP
• CCW 201
• CCW 550 Primer
• Clear Penetrating Sealer
• Simple Kleen Organic
• Simple Kleen Multi-Purpose
• Simple Kleen Heavy Duty
245
Technical Bulletins
RUBBER MAT TEST FOR MOISTURE CONTENT
OF CONCRETE
The moisture content of concrete is required to be a minimum of 5% Relative Humidity
or less. It is required to test for moisture content in a concrete substrate prior to the
installation of any CCW Waterproofing or Air and Vapor Barrier Membrane. This test
can be accomplished through a Rubber Mat Test. The rubber mat test will identify
the presence of excessive moisture in a concrete deck or wall. Capillary moisture in
concrete is detrimental to the adhesion and performance of many waterproofing or air
and vapor barrier system. The Rubber Mat Test procedure is as follows:
Materials:
• 18" x 18" min. 4 to 6 mil polyethylene sheeting or
• 18" x 18" min. 060” EPDM membrane
• 2" min wide duct tape
Test Conditions: Conduct the rubber mat test at a minimum of 40°F for application of
the waterproofing system. Test in direct sunlight or use a sun lamp over the mat (max.
distance 4 feet) in the absence of sunlight. The frequency of test shall be one test mat
every 500 SF.
Procedure: Tape the mat tightly to the concrete surface. Ensure all edges are sealed.
Allow the mat to remain in place for 4 to 24 hours (4 hours minimum). After 4 hours,
remove the mat and visually inspect the underside of the sheet and the corresponding
concrete surface for moisture.
Results: Some dampness may be present in the concrete, however, if visible droplets
of moisture are present beneath the mat; the substrate is too wet to proceed with
waterproofing. Allow the concrete another day or two to dry out and then retest before
applying a waterproofing or air and vapor barrier membrane.
246
Technical Bulletins
CCW MIRADRI 860/861 SHEET MEMBRANE APPLICATION
GUIDE FOR USE WITH EPS FORMING SYSTEMS
CCW MiraDRI 860/861 Self-Adhesive Sheet Membrane can be used in conjunction with
insulated wall forming (ICF) systems using expanded or extruded polystyrene (EPS).
These systems consist of interlocking preformed EPS blocks that create a form for
poured in place concrete. The EPS forms remain in place after the concrete is poured.
The general installation procedures covered in the CCW MiraDRI 860/861 Data Sheet
are to be observed except where this bulletin specifies alternative procedures to address
the special concerns present when working with EPS substrates. Joints or voids in the
surface over 1/4 inch should be filled with non-shrink grout or other EPS compatible
crack filler. Use a 12 inch wide strip of CCW MiraDRI 860/861 centered over inside and
outside corners and at brick ledges. The CCW MiraDRI 860/861 Membrane should be
rolled in place after installation to ensure good adhesion to the EPS and at laps.
Terminations and “T” joints should be sealed the same day with either CCW-201
Polyurethane Sealant or CCW-703V Liquiseal liquid-applied membrane. Solvent
containing products such as CCW-704 Mastic should not be used, since solvents will
soften or dissolve the EPS forming. Pipe and electrical penetrations should also be
sealed with CCW-201 or CCW-703V.
247
Technical Bulletins
APPLICATION OF CCW MIRADRI 860/861
ON PLYWOOD DECKS
The use of CCW MiraDRI 860/861 for waterproofing above grade plywood decks is
an accepted and recommended application for this product. The advantages of using
the CCW MiraDRI 860/861 System for plywood decks include excellent adhesion to
plywood without the use of bonding adhesives and easy to install splices, detailing and
terminations.
Carlisle’s published specifications and details should be followed, including these
additional surface preparation and detailing steps specific to plywood substrates (See
Carlisle detail 860-12):
1. Slope deck 1/8" per foot minimum. Install exterior plywood per American Plywood
Association (APA) recommendations. Use plywood with Grade B or better veneer
for the surface to receive the membrane to minimize surface preparation. Fill
knotholes, voids, or damaged areas with CCW-703 Liquiseal or CCW-201
Polyurethane Sealant.
2. All butt joints in the plywood should be flush and supported by framing or
blocking. The use of tongue and groove plywood is recommended to reduce the
need for extra blocking.
3. Fasten plywood per APA recommendations with non-backing fasteners such as
screws or screw-or ring-shank nails.
4. Plywood must be clean, dry, and free of projections. If plywood has become dusty
or dirty, sweep or wash off all contamination and allow to dry thoroughly. Prime
with CCW-702 at 300-350 sf/gal.
5. Joints in the plywood should be covered with an 8" minimum strip of CCW
MiraDRI 860/861.
6. Install the membrane working from the low point on the deck upwards so that the
laps shed water.
7. Terminate membrane per Carlisle published details. Apply CCW-704 Mastic or
CCW-703 V to all terminations and T-joints at the end of each day.
8. All exposed CCW MiraDRI 860/861 membrane and flashing must be covered
to prevent long term exposure to ultraviolet light. Vertical flashings should be
covered by a metal counterflashing or by the wall surfacing material.
9. Protect the CCW MiraDRI 860/861 membrane from damage from construction
traffic and overburden placement with CCW-Protection Board H.
248
cm
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Carlisle Coatings & Waterproofing
900 Hensley Lane | Wylie, TX 75098 | 800.527.7092 | www.carlisleccw.com
07.31.15 © 2015 Carlisle. Carlisle, Barricoat, Barricure, CAV-GRIP, Liqui-Deck, Liquiseal, MiraDRI, MiraCLAY,
REPRINT CODE: 605485 - “CCW-Waterproofing Field Guide” MiraDRAIN, QuickDRAIN, SecurTAPE, Sure-Seal and Travel-Tack