Proposed Area Program and Project details

Parameters By-laws and Project Proposal Proposed Implications


12314.24 x 0.75 = 9235.65 sq.m. (2.28
75% of Total Area for EWS/LIG
acres)
Plot Area
12314.24 x 0.25 = 3078.59 sq.m. (0.76
25% of Total Area for MIG
acres)
Maximum up to 50% (for EWS/LIG 4617.83 sq.m. of ground available for
component) construction of EWS/LIG component
Ground
Coverage
As per by-laws 35% (for MIG 1077.51 sq.m. of ground available for
component) construction of MIG component
For EWS/LIG:
maximum up to 2.25 FAR shall be Area = 9235.65 sq.m.
constructed on EWS/LIG component. Total Floor area (max.) = 9235.65 *
2.25 = 20780.21 sq.m.
FAR
For MIG:
Area = 3078.59 sq.m.
maximum 3.25 for MIG component.
Total Floor area (max.) = 3078.59 *
3.25 = 10005.42 sq.m.
Built up area (including common
spaces)/DU
EWS floor area upto 27sq.m. EWS upto 36 sq.m.(approx.)
Size of Dwelling
LIG floor area upto 40 sq.m. LIG upto 52 sq.m.(approx.)
unit
MIG floor area upto 100 sq.m.
MIG floor area > 60 sq.m.
Built up area upto 130 sq.m. (approx.)
316 DU in EWS/LIG plot and
192 EWS and 124 LIG
No. of Dwelling minimum 140 units per acre
Units According to Ground coverage and
64 MIG
max. FAR
Front Setback 15m for both components 15m for EWS/LIG/MIG
Shall be minimum of 3m for building
height up to 15m and minimum 6m
3m for EWS & LIG blocks
Side & Rear for building height above 15m. (for
Setback EWS/LIG component)
Minimum setback is 9m as per by-
9m for MIG blocks
laws
Parameters By-laws and Project Proposal Proposed Implications
30m and 12m approach road to
EWS/LIG component
Approach road Minimum 9m
30m, 24m and 12m approach road to
MIG component
G+3 for EWS/LIG
As per by-laws [1.5 times width of
Building height G+7 for MIG flats {< (1.5x30+15) or
road + front setback] max
60m}
Green Area 15% on open area minimum 9235.65 x 0.15 = 1385.35 sq.m.

Community Hall: 120 sq.m.(<3% of


Total maximum 5%
Community total area)
= 1% commercial + 3% educational &
area Offices: 4 x 20 sq.m. each = 80
health + 1% Retail shops
sq.m.(<1%)
Shops: 8 x 11 sq.m. each = 88 (<1%)
Total 120 + 80 + 88 = 288 sq.m. (<5%)

For EWS: 192 x 1 = 192 two-wheelers


1 two wheeler for each unit of EWS
For LIG: 124 x 2 = 248 two-wheelers
and 2 two wheelers for each unit of
Visitor's parking = 25+20+15+14 =74
LIG
two wheelers
Visitor's Parking = 25% of first 100 +
Commercial parking: 288sqm./50 = 6
20% on second 100 + 15% on third
ECU (approx.)
Parking 100 + 10% on rest
Total = 192+248+74 = 514

For MIG flats: 64 x 1=64 car parking


Visitor's parking: 0.25 x 64 = 16 car
1 car/ MIG or 1 ECU/115 sq.m. built-
parking
up area whichever is max
Total = 64 + 16 = 80

In EWS: 192 x 5 = 960


Average household capacity- 5 In LIG: 124 x 5 = 620
persons per EWS/LIG flats staffs = 2
No. of Persons Total: 960 + 620 + 2 = 1582
In MIG flats: 64 x 5 = 320
5 persons/MIG flats staffs = 1
Grand Total = 1582+321 = 1903
Parameters By-laws and Project Proposal Proposed Implications

Total consumption in 1 day:


1903x135=2,56,905
135 lpcd consumption
U.G. water tank Total (adding reserve capacity)=
Also 1 day reserved capacity
256905x2=5,13,810 ~ 5.15 Lacs liters
Dimensions:
3.6m(Depth)x12m(L)x12m(B)
80% sewage generation of per day Tank capacity:
consumption or 108 lpcd as per 0.8 x 256905 = 2,05,524 liters
CPHEEO (Central Public Health and Environmental Dimensions:
STP Engineering Organisation) 3.0m(Depth)x9m(L)x7.6m(B)
1 unit of 2.4m x 2.5m
6 sq.m. on EWS/LIG side
Guard Room 1 at each entrance Another on MIG side of 6 sq.m.