Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 4

PT.

HI-TECH MARINE INSPECTION


HT M a r i n e NDT SERVICE . MARINE CONSULTANT . ENGINEERING SERVICE

MAGNETIC PARTICLE INSPECTION Report No HTM/MT-JOSEPHPLATEAU/02/01/21/036


REPORT Page No 1 of 2
Client PT. Dok Warisan Pertama Date of Inspection 02/01/2020
Site Work PT. Dok Warisan Pertama Drawing No. -
Standard / Code IACS Recommendation No.20 Procedure No. HTM-NDT-02
Acceptance Criteria Table 3 of IACS No. 20 Surface Condition As Weld
Project Name JOSEPH PLATEAU Type of Weld Butt Weld
Brand MAGNATEST Thickness -
Model KY-2 Material Carbon Steel
EQUIPMENT
Serial No 220109 Surface Temperature Ambient
Flux Burmah Castrol Applying Current Continuous √ Residual
Current 110 VOLT Magnetic Current AC √ DC
Pole Spacing 4'' - 6'' Calibration 10 LBS / 4,5 KG
Amperage 5 Amp Chemical Brand NABAKEM
Demagnetization Yes No √ Medium SM-15 Magnetic Particle
Applicable Particle Wet √ Dry Background MP-35 White Paint
No. Weld Identification Quantity (Joint) Process Discontinuity Evaluation Result Remark

1 BRACKET 2419 x 496 x 15 1 SMAW NAD ACC 100%

NAD
2 BRACKET 2576 x 498 x 16 1 SMAW NAD ACC 100%

3 BRACKET 1447 x 481 x 17 1 SMAW NAD ACC 100%

4 BRACKET 445 x 450 x 15 1 SMAW NAD ACC 100%

5 BRACKET 199 x 187 x 15 1 SMAW NAD ACC 100%

6 PIPE 9391 Æ 254 x 16 3 SMAW NAD ACC 100%

Remark : MPI 20% ACC

Tested By QC Inspector Client Reviewed By Class


( ASNT MT/PT/UT Lev II )

NABIL AGA H
Name /Signature Name / Signature Name / Signature Name / Signature
Date : 02/01/2021 Date : Date : Date :
Legend :
P : Planar - Lack of Penetration/Lack of Fusion/Crack Acc : Accept
C : Cylindrical - Slag Inclusion Rej : Reject
S : Spherical - Porosity NAD : Not Appearance Discontinuity
Column1 Column2 Column3
PT.HI-TECH MARINE INSPECTION
HT M a r in e NDT SERVICE . MARINE CONSULTANT . ENGINEERING SERVICE

PAGE 2 of 2
CLIENT PT. Dok Warisan Pertama
MAGNETIC PARTICLE TEST REPORT JOB NO. -

REPORT NO 'HTM/MT-JOSEPHPLATEAU/02/01/21/036

MPI

UPPER SHEAVE SUPPORT CONTRUCTION

REMARK : MPI 20% ACC


Tested By QC Inspector Client Reviewed By Class
( ASNT MT/PT/UT Lev II )

ERIC EKA K
Name / Signature Name / Signature Name / Signature Name / Signature
Date :02/01/2021 Date : Date : Date :