Pump size & type / Stages : ZLND 080400 /1

Based on curve no. :-


Impeller diameter : 14.56 in

Customer : FLOWSERVE COLOMBIA SAS Capacity : 24,53


Item number :- Head : 70,44
Service :- Density / Specific gravity : - / 1.001
Flowserve reference : 2385440639 Pump speed : 1750 rpm
Date :- Ns / Nss : - / 10490 (US units)

Copyright © 2016 Flowserve. All rights reserved. -


Hydraulic Datasheet

Customer : FLOWSERVE COLOMBIA SAS Pump / Stages : ZLND 080400 /1


Customer reference : VARIAS 2020 Based on curve no. :-
Item number :- Flowserve reference : 2385440639
Service :- Date : May 14, 2020
Operating Conditions Materials / Specification
Capacity (rated/normal) : 24,53 / - Material column code : 0B
Water capacity (CQ=1.00) :- Pump specification :-
Total developed head : 70,44 Other Requirements
Water head (CH=1.00) :- Hydraulic selection : No specification
NPSHa/NPSHa less margin : 34.0 ft / - Construction : No specification
Maximum suction pressure : 0.0 psig Test tolerance : ANSI/HI 14.6 Grade 3B
Liquid Driver Sizing : Max Power(MCSF to EOC) not using SF
Liquid type : Other
Liquid description : Other
Temperature : 68 °F
Density / Specific gravity : - / 1.001
Solid Size - Actual / Limit :-/-
Viscosity / Vapor pressure : 1.00 cP / -
Performance
Hydraulic power : 4,708 Impeller diameter
Pump speed : 1750 rpm Rated : 14.56 in
Pump overall efficiency (CE=1.00) : 31,92 Maximum : 16.10 in
NPSH required (NPSH3) : 0,94 Minimum : 13.19 in
Rated brake power : 14,89 Ns / Nss : - / 10490 (US units)
Including magnet power losses of :- Minimum continuous flow : 41.8 USgpm
Maximum brake power : 31,86 Maximum head at rated diameter : 100.32 psi
Driver power rating : 20,24 hp / 14,89 kW Flow at BEP : 421.9 USgpm
Casing working pressure : 232.1 psig Flow as % of BEP : 25.6 %
(based on shut off @ cut dia/rated SG) Efficiency at normal flow :-
Maximum allowable : 232,06 Impeller diameter ratio (rated/max) : 90.4 %
Hydrostatic test pressure : 348,09 Head rise to shut off : 0.2 %
Estimated rated seal chamber pressure :- Total head ratio (rated / max) / (max / rated) : 99.8 % / -
CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY.

Copyright © 2016 Flowserve. All rights reserved. Affinity v2.17.1