Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

STANDARD ORIFICES MP

The law of continuity of flow reads:


If a process fliud flows through a piping, that flow is equal at every cross-section of the piping regardless of its diameter. If
there is a constriction in the piping, the velocity of flow at that point will increase because the same quality of fluid must flow
through in the unit of time as at the point of the larger cross-section. Further, in conformity with the law of conservation of energy
(Bernouille theorem), the energy consisting of the sum of the kinetic energy (velocity) and the static pressure must be constant
at such a point. The consequence is that if the velocity of flow is increased in the area of constriction (increase of the kinetic
energy), the static pressure energy must decrease in the same amount to obtain an equal sum of both these energies. A drop
of the static pressure is called the differential pressure. By mathematical derivation from these two theorems we arrive at an
expression for the flow in dependance on the differential pressure at the construction area (orifice):

q = c •. ∆p , where q - mass or volume (qm, qv) flow


∆ p - differenttial pressure
c - the constant depends on the orifice configuration
and the process fluid characteristic

STANDARD ORIFICES WITH ANNULAR CHAMBERS TO DIN STANDARDS

Basic construction characteristics and use:

- very accurate measurement is achived by an annu-


lar chamber with corner tapping at 6 points because
by this method is measured the mean value of dif-
ferential pressure:

- suitable for measurement of process fluid veloci-


ties below 40 m/s
,
- for 5 .10 3 Re 10 7 (Reynold s number)

- with orifices having rated pressure PN 64 and PN


100 expensive grooved packing for flanged connec-
tions are not required because gasket grooves en-
able the installation of It-gaskets

- very simple replacement of orifice plates in opera-


tion;

- calculation of orifice bore to DIN 1952 and ISO


5167.

Construction configuration to DIN 1952, DIN 19205


and ISO 5167, for liquids, vapors and gases. Use:
For non-corrosive service and temperatures: up to 400OC
Overall lengh: 65 mm Orifice plate material: W.-Nr.1.4541
Nominal pipes size: DN 50 to DN 500 Carrier ring material: W.-Nr.1.0402
Rated pressure: PN 16 to PN 100 Gasket material: It
Angle between pressure tappings: 0O, 90O, 180O
Pressure tappings connection: G 1/2 to DIN 19207 FORMV
ATM supplies orifices with 2 flange gasket. Flanges
and bolts are not in the delivery. Flanges to DIN 2633-DIN 2637
Gasket grooves to DIN 2512 (only for PN64 / PN100)

ATM Ltd.  +385 1 2499 410  +385 1 2499 420  info@atm.hr MP_ae2 61
STANDARD ORIFICE WITH ANNULAR
MP
CHAMBERS TO DIN STANDARDS

DIMENSIONS

PN 16
PN 64
PN 25
PN 100
PN 40

Pipe size DN 50 DN 65 DN 80 DN 100 DN 125 DN 150 DN 175 DN 200 DN 250 DN 300 DN 350 DN 400 DN 500
a 2 2 4 5 5 5 5 5 5 5 5 7 7
b 85 ‚104 116 140 166 195 224 248 304 357 411 462 575
NP 16 302 322 338 358 388 412 442 468 520 578 550 690 810
NP 25 - - - - - - 448 478 535 595 650 705 815
c NP 40 302 322 338 362 388 418 460 485 545 610 665 735 815
NP 64 302 322 338 362 388 418 460 485 545 610 665 735 -
NP 100 302 322 338 362 388 418 460 485 545 610 665 - -
NP 16 102 122 138 158 188 212 242 268 320 378 438 490 610
NP 25 - - - - - - 248 278 335 395 450 505 615
d NP 40 102 122 138 162 188 218 260 285 345 410 465 535 615
NP 64 102 122 138 162 188 218 260 285 345 410 465 535 -
NP 100 102 122 138 162 188 218 260 285 345 410 465 - -
e 72 94 105 128 154 182 212 238 291 342 394 446 548
h 89 110 121 150 176 204 234 260 313 364 422 474 576
f 2.5 2.5 2.5 3 3 3 3 3 3 3 3.5 3.5 3.5

ORDERING DATA

R ated pressure 16 R ated pressure 25 R ated pressure 40 R ated pressure 64 R ated pressure 100
P ip e P ip e P ipe P ipe P ipe
C ode-N o. C ode-N o. C ode-N o. C ode-N o. C ode-N o.
DN D DN D DN D DN D DN D
50 51.2 39.21.515 50 51.2 39.21.555 50 51.2 39.21.575 50 50.6 39.21.594
50 54.5 39.21.516 50 54.5 39.21.556 50 54.5 39.21.576 50 53.9 39.21.595
65 70.3 39.21.517 65 70.3 39.21.557 65 69.7 39.21.577 65 68.9 39.21.596
80 82.5 39.21.518 80 82.5 39.21.558 80 81.7 39.21.578 80 80.9 39.21.597
100 100.8 39.21.519 100 100.8 39.21.559 100 100 39.21.579 100 98 39.21.598
100 107.1 39.21.520 100 107.1 39.21.560 100 106.3 39.21.580 100 104.3 39.21.599
125 125 39.21.521 125 125 39.21.561 125 124 39.21.581 125 120.4 39.21.600
125 131.7 39.21.522 125 131.7 39.21.562 125 130.7 39.21.582 125 127.1 39.21.601
150 150 39.21.523 150 150 39.21.563 150 147.8 39.21.583 150 144.8 39.21.602
150 159.3 39.21.524 150 159.3 39.21.564 150 157.1 39.21.584 150 154.1 39.21.603
175 182.9 39.21.525 175 182.9 39.21.545 175 182.9 39.21.565 175 181.1 39.21.585 175 176.1 39.21.604
200 207.3 39.21.526 200 206.3 39.21.546 200 206.5 39.21.566 200 204.9 39.21.586 200 199.1 39.21.605
250 254.4 39.21.527 250 252.8 39.21.547 250 252.8 39.21.567 250 249.4 39.21.587 250 242 39.21.606
250 260.4 39.21.528 250 258.8 39.21.548 250 258.8 39.21.568 250 255.4 39.21.588 250 248 39.21.607
300 309.7 39.21.529 300 307.9 39.21.549 300 307.9 39.21.569 300 301.9 39.21.589 300 295.5 39.21.608
350 339.6 39.21.530 350 339.6 39.21.550 350 338 39.21.570 350 330.6 39.21.590
350 352 39.21.531 350 352 39.21.551 350 350.4 39.21.571 350 343 39.21.591
400 390.4 39.21.532 400 388.8 39.21.552 400 384.4 39.21.572 400 378 39.21.592
400 403 39.21.533 400 401.4 39.21.553 400 397 39.21.573 400 390.6 39.21.593
500 492 39.21.534 500 488 39.21.554 500 479.6 39.21.574

NOTE: Before placing an order for orifices or orifice plates kindly fill up
ATM Flow Measurement Questionnaire.

ATM Ltd. +385 1 2499 410 +385 1 2499 420 info@atm.hr MP_ae2 62
ORIFICE FLANGE UNIONS TO ASA STANDARDS TYPE RF MP

DIMENSIONS AND ORDERING DATA

Pipe DN
Code-No.
E G SCH 300 lb 600 lb
40.9 3.7 40 39.22.551 39.22.587
48.3 38.1 5.1 80 1 1/2" 39.22.552 39.22.588
34 7.15 160 39.22.553 39.22.589
52.5 3.95 40 39.22.554 39.22.590
60.4 49.2 5.6 80 2" 39.22.555 39.22.591
42.8 8.8 160 39.22.556 39.22.592
77.9 5.5 40 39.22.557 39.22.593
88.9 73.6 7.65 80 3" 39.22.558 39.22.594
66.6 11.15 160 39.22.559 39.22.595
102.3 6.0 40 39.22.560 39.22.596
114.3 97.2 8.55 80 4" 39.22.561 39.22.597
87.3 13.5 160 39.22.562 39.22.598
154 7.15 40 39.22.563 39.22.599
168.3 146.3 11.0 80 6" 39.22.564 39.22.600
131.7 18.3 160 39.22.565 39.22.601
A B C D
DN
mm mm mm mm 202.7 8.15 40 39.22.566 39.22.602
R a te d p re ss u re A N S I 3 0 0 lb R F F = 1 .6 m m
219.0 193.7 12.65 80 8" 39.22.567 39.22.603
1 1 /2 " 156 3 8 .1 86 70
2" 165 3 8 .1 86 84 173 23.0 160 39.22.568 39.22.604
3" 210 3 8 .1 89 118 254.5 9.25 40 39.22.569 39.22.605
4" 254 3 8 .1 92 146
6" 318 3 8 .1 102 206
273.0 242.9 15.05 80 10" 39.22.570 39.22.606
8" 381 4 1 .3 111 260 215.9 28.55 160 39.22.571 39.22.607
10" 444 4 7 .6 117 321
303.2 10.3 40 39.22.572 39.22.608
12" 521 5 0 .8 130 375
14" 584 54 143 425
323.8 289 17.4 80 12" 39.22.573 39.22.609
16" 647 57 146 482 257.2 33.3 160 39.22.574 39.22.610
18" 711 6 0 .5 159 533
333.3 11.15 40 39.22.575 39.22.611
20" 774 6 3 .5 162 587
355.6 317.5 19.05 80 14" 39.22.576 39.22.612
A B C D 284.2 35.7 160 39.22.577 39.22.613
DN
mm mm mm mm
381 12.7 40 39.22.578 39.22.614
Rated pressure ANSI 600lb RF F = 6.4 mm
406.4 363.5 21.45 80 16" 39.22.579 39.22.615
1 1/2" 156 38.1 86 70
325.4 40.5 160 39.22.580 39.22.616
2" 165 38.1 86 84
428.6 14.3 40 39.22.581 39.22.617
3" 210 38.1 89 118
457.2 409.5 23.85 80 18" 39.22.582 39.22.618
4" 273 44.5 108 152
366.7 45.25 160 39.22.583 39.22.619
6" 356 54 124 222
8" 419 62 140 273 477.8 15.1 40 39.22.584 39.22.620

10" 508 70 159 343 508.0 455.6 26.2 80 20" 39.22.585 39.22.621

12" 559 73 162 400 408 50 160 39.22.586 39.22.622

ATM Ltd. +385 1 2499 410 +385 1 2499 420 info@atm.hr MP_ae2 63
ORIFICE FLANGE UNION TO ASA STANDARDS TYPE RF MP

Type “Flange Taps” manufactured to ANSI B 16.5 and


A.G.A. Report No.3.
Flange type: “Welding Neck”
Nominal pipe size 1 1/2” to 20”
Rated pressure (class): 300 lb to 600 lb
Use: non-corrosive service and temperatures up to 400 0C
Flange material: W.Nr. 1.042
Stud material: W.Nr. 1.7225
Nut material: W.Nr. 1.0501
∆ = 1,5 mm) Tesnit unit
Gasket material (∆
Orifice plate material: W.Nr. 1.4541
Plug material: W.Nr. 1.0501
Pressure tapping: 1/2 - 14 NPT
Studs dimensions to ASA B1.1 with rolled thread
along the entire shank

ORIFICE PLATE

FOR ORIFICES - FLANGE UNIONS TO For flow measurement of liquids, gases and steam.
ASA STANDARDS - TYPE RF Manufactured to ASA standards:ISA RP3.2, ASME PTC 19.5
For orifice flange-unions to ANSI B 16.36 or ANSI B 16.5
RF, type “Welding Neck” and “Slip on”
Nominal width 1 1/2” to 20”
Rated pressure 300 lb and 600 lb
For non-corrosive and corrosive service:
Material: W.Nr. 1.4541
D - drain hole on request
V - vent hole on request
f - piping ID to be specified by buyer

Construction features:
- concentric orifice plate bore
- manifactured to A. G. A. Report No. 3
- stamped: bore diameter “d”, pipe ID “D”,
material, Tag No and “inlet”.

Also available:
- quarter circle orifice plate
- concial entrance orifice plate
- flow in both directions
- corrosive service
- other nominal sizes and rated pressures.

Pipe size 11/2" 2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20"
For temperaturs above 315 0C,
thickness “a” increasses
a( 350°C) 3 3 3 3 3 3 6 6 6 9 9 9 acording to ASME PTC 19.5
150 lb 85,7 104,8 136,5 174,6 222,3 279,4 339,7 409,6 450,8 513,4 549,3 606,4
a 300 lb 95,3 111,1 149,2 181,0 250,8 308,0 362,0 422,3 485,8 539,8 596,9 654,1 NOTE: Before placing an order
600 lb 95,3 111,1 149,2 193,7 266,7 320,7 400,1 457,2 492,1 565,2 612,8 682,6
for orifices or orifice plates kindly
fill up ATM Flow Measurement
150 lb 70 70 70 81 81 81 81 88 88 88 100 114 Questionnaire.
b 300 lb 88 88 88 100 100 100 100 114 114 114 127 127
600 lb 88 88 88 100 100 114 114 114 114 127 127 127
150 lb 30 30 30 30 40 40 40 40 40 40 40 40
c 300 lb 30 30 30 30 40 40 40 40 40 40 40 40
600 lb 30 30 30 30 40 40 40 40 50 50 50 50

ATM Ltd. +385 1 2499 410 +385 1 2499 420 info@atm.hr MP_ae2 64
ORIFICE FLANGE UNIONS TO ASA STANDARDS TYPE RJ MP

Type “Flange Taps” manufactured to


ANSI B 16.5 and A. G. A. Report No 3.
Flange type “Welding Neck”.
Nominal size 1 ½” to 20”.
Rated class: 300lb and 600lb (other classes on request).
Use: non-corrosive service and
temperatures up to 400°C.
Flange material: W.Nr.1.0402.
Stud material: W.Nr.1.7225.
Nut material: W.Nr.1.0501.
Orifice plate holder material: W.Nr.1.0501.
Orifice plate material: W.Nr.1.4541.
Plug material: W.Nr.1.0501.
Pressure tapping: ½ - 14 NPT F.
Studs dimensions to ASA B1.1 with
rolled thread along the entire shank.

A B C D F
DN
mm mm mm mm mm
Rated pressure ANSI 300 lb RJ
1 1/2" 156 42.9 90.7 70 6.4
2" 165 44.4 92.2 84 7.9
3" 210 44.4 95.2 117 7.9

A 4" 254 44.4 98.2 146 7.9


6" 318 44.4 106.4 206 7.9
D
8" 381 47.4 117.6 260 7.9
E
10" 444 54.1 123.6 320 7.9
G
12" 521 57.1 136.3 375 7.9
14" 584 60.1 149 425 7.9
16" 648 63.5 152.3 483 7.9
18" 711 66.8 165.1 533 7.9
20" 775 71.4 170 587 9.5
Rated pressure ANSI 600 lb RJ
1 1/2" 156 44.5 92.3 70 6.4
2" 165 46 93.8 84 7.9
3" 210 46 96.8 118 7.9
B

4" 273 46 109.5 152 7.9


C

6" 356 55.7 125.2 222 7.9


8" 419 63.5 141.3 273 7.9
10" 508 71.4 160.3 343 7.9
12" 559 74.4 163.3 400 7.9
14" 603 77.8 173 432 7.9
16" 686 84.1 185.7 495 7.9
18" 743 90.5 192.1 546 7.9
20" 813 98.4 200 610 9.5

ATM Ltd.  +385 1 2499 410  +385 1 2499 420  info@atm.hr MP_ae2 65
ORIFICE FLANGE UNION TO ASA STANDARDS TYPE RJ MP

DIMENSIONS AND ORDERING DATA

Pipe DN
Code No.
E G SCH 300 lb 600 lb
40.9 3.7 40 39.23.551 39.23.587
48.3 38.1 5.1 80 1 1/2" 39.23.552 39.23.588
34 7.15 160 39.23.553 39.23.589
52.5 3.95 40 39.23.554 39.23.590
60.4 49.2 5.6 80 2" 39.23.555 39.23.591
42.8 8.8 160 39.23.556 39.23.592
77.9 5.5 40 39.23.557 39.23.593
88.9 73.6 7.65 80 3" 39.23.558 39.23.594
66.6 11.15 160 39.23.559 39.23.595
102.3 6.0 40 39.23.560 39.23.596
114.3 97.2 8.55 80 4" 39.23.561 39.23.597
87.3 13.5 160 39.23.562 39.23.598
154 7.15 40 39.23.563 39.23.599
168.3 146.3 11.0 80 6" 39.23.564 39.23.600
131.7 18.3 160 39.23.565 39.23.601
202.7 8.15 40 39.23.566 39.23.602
219.0 193.7 12.65 80 8" 39.23.567 39.23.603
173 23.0 160 39.23.568 39.23.604
254.5 9.25 40 39.23.569 39.23.605
273.0 242.9 15.05 80 10" 39.23.570 39.23.606
215.9 28.55 160 39.23.571 39.23.607
303.2 10.3 40 39.23.572 39.23.608
323.8 289 17.4 80 12" 39.23.573 39.23.609
257.2 33.3 160 39.23.574 39.23.610
333.3 11.15 40 39.23.575 39.23.611
355.6 317.5 19.05 80 14" 39.23.576 39.23.612
284.2 35.7 160 39.23.577 39.23.613
381 12.7 40 39.23.578 39.23.614
406.4 363.5 21.45 80 16" 39.23.579 39.23.615
325.4 40.5 160 39.23.580 39.23.616
428.6 14.3 40 39.23.581 39.23.617
457.2 409.5 23.85 80 18" 39.23.582 39.23.618
366.7 45.25 160 39.23.583 39.23.619
477.8 15.1 40 39.23.584 39.23.620
508.0 455.6 26.2 80 20" 39.23.585 39.23.621
408 50 160 39.23.586 39.23.622

ATM Ltd.  +385 1 2499 410  +385 1 2499 420  info@atm.hr MP_ed2 66
ORIFICE FLANGE UNION TO ASA STANDARDS TYPE RJ MP

ORIFICE PLATE
For flow measurement of liquids, gases and steam.
Manufactured to ASA standards ISA RP3.2, ASME PTC 19.5.
For orifice flange unions to ANSI B 16.36 or ANSI B 16.5 RJ, type ''Welding Neck'' and ''Slip on''.
Nominal width 1 1/2" to 20", rated pressure 300 lb and 600 lb, material W.Nr.1.4541.
For non-aggressive and aggressive media.
Construction features of standard orifice plate:
- concentric orifice plate bore
- manufactured to A. G. A. Report No. 3.
- stamped bore diameter ''d'', pipe ID ''D u '', material, Tag No and ''inlet''.
FOR ORIFICE FLANGE UNIONS TO ASA STANDARDS – TYPE RJ
G

G
W=3.18 4.8
23° ± 3

23° ± 3

23° ± 3
V

0'

0'

0'
W 4.8 4.8
V

L L L
M
D0 - "Welding neck"

D0 - "Welding neck"
K - "Welding neck"
D1 - "Slip on"

D1 - "Slip on"
K1 - "Slip on"
BB

BB

B
P

P
d

T T T
D

D
D

W=6.4
H H H

a) b) c)
a) Orifice plate for flanges under 3" D u- inner pipe diameter
b) Orifice plate with holder for flanges from 4" to 6" S - pipe wall thickness
c) Orifice plate with holder for flanges over 8" D v - outer pipe diameter

For orifice plate code number – to the code number of orifice flange union the number – 801 will be added
(for example 3'' 600 SCH 80 - 39.23.594-801).
D / V - drain / vent hole on request
H L M G
BB B W T K K1 P
300 600
C
300 600 300 600
D0 D1
300 600
For temperatures above 315°C thickness
1 1/2 3.2 0.8 68.3 25.4 5.4 11.1 90 “a” increases according to ASME PTC 19.5
D 1=(D V-1%)-2(S+15%)+0.79
K 1 =(D V -1%)-2(S+15%)-1.59

2 3.2 0.8 82.6 27.0 7.8 11.9 90


3 3.2 0.8 123.8 27.0 7.8 11.9 90 Also available:
4 134.9 3.2 1.6 149.2 26.2 27.0 7.8 14.7 15.1 11.5 11.9 100 110 - “quarter circle” orifice plate
D 0 = D U+ 0.79
K = D U- 1.59

6 196.9 3.2 1.6 211.1 26.2 27.0 7.8 14.7 15.1 11.5 11.9 120 140 - for aggressive media;
8 253.6 255.6 3.2 3.2 269.9 26.2 27.0 7.8 14.7 15.1 11.5 11.9 120 140
10 307.6 309.6 3.2 3.2 323.9 26.2 27.0 7.8 14.7 15.1 11.5 11.9 125 185 - for other nominal sizes and
12 359.6 353.5 3.2 3.2 381.0 26.2 27.0 7.8 14.7 15.1 11.5 11.9 165 185 rated pressures.
14 379.7 401.6 3.2 3.2 419.1 26.2 27.0 7.8 14.7 15.1 11.5 11.9 180 185
16 448.5 452.4 6.4 6.4 469.9 27.8 28.6 7.8 16.3 16.7 11.5 11.9 180 200
18 512.0 515.9 6.4 6.4 533.4 27.8 28.6 7.8 16.3 16.7 11.5 11.9 180 200 NOTE: Before ordering kindly fill up
20 561.2 565.2 6.4 6.4 584.2 29.4 30.2 8.7 17.1 17.5 12.3 12.7 190 210 ATM Flow Measurement Questionnaire.

ATM Ltd.  +385 1 2499 410  +385 1 2499 420  info@atm.hr MP_ae2 67