SAUDI ARAMCO TEST REPORT
Calibration Test Report - Pressure Recorder SATR-A-2004 22-Jan-18 MECH
PROJECT TITLE WBS/BI/JO NUMBER CONTRACTOR/SUBCONTRACTOR

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION EQPT CODE SYSTEM P.O. NUMBER

LAYOUT DRAWING NUMBER REV. NO. S/U SYSTEM FACILITY

TASK COMPLETED DATE RFI No. REQUESTED INSPECTION DATE QUANTITY MANHOURS TRAVEL TIME
SPENT

SHADED AREAS FOR SAUDI ARAMCO USE ONLY

Pressure Recorder-Calibration Test Report (See Notes Below)


Tested Instrument:
Type / Description
(Available Calibration Options, User, Factory: zero point or Manufacturer/Specs
span, NIST traceable )

Model Serial No.

Pressure Range Calibration Range

Calibration Date Next Calibration Due

Calibration By

Applied Load, bar Pressure Recorder


Difference, Bar Error, % FSD
(standard Pressure) Graph (Division) Equivalent (Bar)

Master Instrument Used For Calibration


Description Dead Weight Tester/Test Gage Manufacturer/Specification

Model / Type Serial No.

Pressure Range Calibration Date

Certificate No Next Calibration Due:

Notes: 1) Calibrated at Ambient Temperature of 23 ºC (±2 ºC). 2) Calibration is required whenever pressure recorder is believed to be in error
regardless of last calibration date. Maximum calibration interval shall not exceed 12 months (Sch Q, Att IV, Section7). Apply legible sticker to
recorder. Pressure Recorders are very expensive and delicate instruments. As calibrated, they exhibit no evidence of mechanical damage or
mishandling. Safety Item: Damaged pressure recorders shall be sent for repair by manufacturer authorized personnel. Report damaged recorders to
Quality for entry into equipment log and investigation for root cause of damage.

Remarks:

REFERENCE DOCUMENTS:
1. SAES-A-004 - General Requirements of Pressure Testing (28 August 2016)
2. ASME/ANSI PTC 19.2, Pressure Measurement Instruments & Apparatus, (2010 Edition)
3. SCH. Q (JAZAN Feb 2008)

Contractor Saudi Aramco


Calibration Technician: PMT Representative:
Name, Signature, & Date: Verified ¨ Reviewed ¨

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU -22- Jan-2018 - REV. 2017.12.00 (Standards Cutoff -December 31, 2017) Rev. 2017.12.00 31-Dec-17
SATR NUMBER DATE APPROVED DISCIPLINE
SAUDI ARAMCO TEST REPORT
Calibration Test Report - Pressure Recorder SATR-A-2004 22-Jan-18 MECH
PROJECT TITLE WBS/BI/JO NUMBER CONTRACTOR/SUBCONTRACTOR

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION EQPT CODE SYSTEM P.O. NUMBER

LAYOUT DRAWING NUMBER REV. NO. S/U SYSTEM FACILITY

TASK COMPLETED DATE RFI No. REQUESTED INSPECTION DATE QUANTITY MANHOURS TRAVEL TIME
SPENT

SHADED AREAS FOR SAUDI ARAMCO USE ONLY

Pressure Recorder-Calibration Test Report (See Notes Below)


Tested Instrument:
Type / Description
(Available Calibration Options, User, Factory: zero point or Manufacturer/Specs
span, NIST traceable )

Model Serial No.

Pressure Range Calibration Range

Calibration Date Next Calibration Due


QC Inspector PID Representative:
Name, Initials & Date: Verified ¨ Reviewed ¨
QA/QC Supervisor Proponent and Others:
Name, Signature & Date: Verified ¨ Reviewed ¨
*Person Responsible for Implementation of Test and Analysis of Results Y = YES N = NO F = FAILED