Professional Documents
Culture Documents
SCOUT140EX Vibration Data Collector Datasheet 323330 PDF
SCOUT140EX Vibration Data Collector Datasheet 323330 PDF
Description
The SCOUT140EX Vibration Data Collector, Analyzer and
Balancer is a portable hardware monitoring device that
supports four-channel vibration data collection, analysis,
and balancing. Use the device to collect data from sensors on
a route, for machine-side analysis and diagnosis, and on-site
dynamic balance correction.
The SCOUT140EX is ATEX Zone 2 and IECEx Zone 2 compliant
and safe for hazardous areas. It is both light and rugged. The
neck strap includes an integrated Sensor Keeper that
restrains your sensor while you walk or climb to reach other
machines.
The device includes a complete suite of advanced recording
and analysis capabilities, including tri-axial and 6Pack
recordings, coast-down, long time waveform, modal analysis
and cross channel spectrum (ODS).
The SCOUT140EX offers plenty of storage and long battery life.
The device comes with a five year warranty. It works with
System 1 software.
The SCOUT140EX Vibration Data Collector, Analyzer and
Balancer offers the following features:
2/9
SCOUT140EX Vibration Data Collector, Analyzer and Balancer
Datasheet 323330 Rev. T
Specifications Tachometer
Sensors Sensor
Laser sensor with reflective tape
Sensor triggers on beam reflection
Four Channels 10 cm to 2 m nominal
Sensor input Laser sensor
Simultaneous sampling Range depends on size of reflective
range
Accelerometer, velocity, tape
Compatible
displacement, current, voltage Other sensor Contact, TTL Pulse, Keyphasor
sensor types
output and 4 to 20 mA types Instrument has optically isolated
16 V peak-peak supported input
AC coupled
Allows for ± 8 V sensor output swing Power supply
range 5 V, 50 mA
(± 80 g) to sensor
0 to 20 V 3.5 V (4 mA) min
TTL pulse
DC coupled -10 to 10 V 28 V (5 mA) max
rating
ranges -20 to 0 V Off-state 0.8 V
E.g. for reading prox-probe gap 7.7 ± 0.5 V
Keyphasor 13.2 ± 0.8 V
1 x BNC (CH1) threshold 18.5 ± 1 V
1 x LEMO (CH2/CH3/CH4) Nominally 8 V, 13 V, 18 V
Connectors
10 RPM to 300,000 RPM
Safety feature: Break-free inline
Speed range (0.2 Hz to 5 kHz)
connector
Analog to Pulse width at least 0.1 ms
digital 24-bit ADC Accuracy ± 0.1 %
conversion
Up to 140 Hz (8400 CPM)
0 mA or 2.2 mA (configurable), Output to Typical
Sensor 24 V maximum drive strobe Depends on strobe type
excitation Special cable required
current 2.2 mA required power for IEPE/ICP-
type accelerometer
Logging & Analysis
Sensor Warns if short circuit or not
detection connected Instrument screen
Output
Transfer to Ascent, XML, UFF file export via
Waveform Display formats
USB, System 1 software
Dual 1 GB non-volatile flash memories
Number of Data
1024, 2048, 4096, 8192, 16,384, 32,768 Database mirror copy on second flash
samples storage
memory
10 ms to 512 seconds
Time scale Folders/machines/points/locations/route
or orders based from 1 to 999 revs Data s
Time 1, 2, 4, 8, 16, 32, 64, 128 storage
synchronous Only available when tachometer structure No limits are applied
50 character names
averages triggered
Max
Long time 25 Hz to 80 kHz folder 10,000 measurement locations
waveform size
Fmax 20 kHz dual channel
CH1 for hammer, up to 3 response
14.7 million samples (total over Modal channels, ≤ 10 kHz
Long time channels) analysis Coherence and FRF —
waveform E.g. for Fmax 1 kHz Accelerance/Mobility/Compliance
duration Fsample = 2.56 kHz and
Cross 1 Reference and up to 3 other sensors
Duration = 1.6 hrs
channel
spectru Coherence and FRF for importing into ODS
m software
3/9
SCOUT140EX Vibration Data Collector, Analyzer and Balancer
Datasheet 323330 Rev. T
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
Parameter Indication ≤ 0.1 dB 10 Hz to <100 Hz
≤ 1.5 dB 1 Hz to <10 Hz
> 1000 g (10,000 m/s2)
> 1000 in/sec (25,000 mm/s) Low frequency mode:
> 20 in (500 mm) When Coupling = DC and Fmax ≤ 100
Maximum Attenuation Hz
levels (peak) > 10,000 Amps
due to
Effective limit is sensor sensitivity and Normal mode is applicable in all
Integration
output voltage other cases.
4/9
SCOUT140EX Vibration Data Collector, Analyzer and Balancer
Datasheet 323330 Rev. T
Or equivalent CPM values Resolution and 480 x 320 (HVGA), 5.5” (140 mm)
Or orders-based from 1X to 999X size Readable in direct sunlight
0 to Fmax Supported English, French, Spanish,
Fmin possible
Instrument zeroes all spectral lines Languages Portuguese, Russian, Chinese
range
below Fmin.
USB and Ethernet
400, 800, 1600, 3200, 6400 and
Communication (optional USB dongle)
12,800 lines
with PC Use PROFLASH to upgrade
6400 lines max. for dual channel
Resolution instrument firmware
measurements
3200 lines max. for four-channel USB 2.0, supplying 5V, 250mA
measurements USB host port
Save folders to USB flash drive
Frequency Hz, CPM, Orders Spectra, Coherence, FRF
scale Linear scale with zooming magnitude and phase
Acceleration, velocity, displacement, UFF export
Universal File Format for Modal
current or user-defined
Amplitude and FRF data
scale
Linear or log scales, auto or manual
scaling Battery and Charger
Window Hanning Custom Lithium Ion pack, 7.4 V, 5000
shapes Rectangular Battery type
mAh
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) % Operating 10 hours
Overlap Depends on Fmax and number of time Backlight on — 60 second timeout
lines Internal charging, automatic control
1, 2, 4, 8, 16, 32, 64, 128 Charger type External power pack 12 V DC, 3 A
Number of output
Increases sampling time
averages
proportionally 3 A nominal
Charge rate
Averaging Linear, exponential, peak hold, 3 hours for complete charge
types synchronous
23 bandwidth options
Environmental Limits
Demodulation
bandwidths From 125 Hz to 1250 Hz Operating
14 °F to 122 °F (-10 to 50 °C)
Up to 16 kHz to 20 kHz temperature
Up to 40 kHz & 3200 lines (1 channel) Storage -4 °F to 140 °F (-20 to 60 °C), 95% RH
Up to 20 kHz & 1600 lines (3 temperature Up to 95 F (35 C), 85% RH if storage
channels) & humidity exceeds one month
6Pack
Spectrum and waveform for low- 4’ (1.2 m) drop onto concrete, IP65
frequency, Ruggedness Procedure: 26 drops following
high-frequency demodulation MIL-STD-810F-516.5-IV
5/9
SCOUT140EX Vibration Data Collector, Analyzer and Balancer
Datasheet 323330 Rev. T
EMC
EN 61000-6-2
EN 61000-6-4
EMC Directive 2014/30/EU
RoHS
RoHS Directive 2011/65/EU
LVD
EN 61010-1
LV Directive 2014/35/EU
ATEX
ATEX Directive 2014/34/EU
6/9
SCOUT140EX Vibration Data Collector, Analyzer and Balancer
Datasheet 323330 Rev. T
7/9
SCOUT140EX Vibration Data Collector, Analyzer and Balancer
Datasheet 323330 Rev. T
Part Number Description
CLK20399 Aditional L2 user activation
Zone 2 Laser Tach Kit - LASA0315 SUNW0401 Network upgrade
8/9
SCOUT140EX Vibration Data Collector, Analyzer and Balancer
Datasheet 323330 Rev. T
Bently Nevada, Keyphasor, System 1, SCOUT, 6Pack and Orbit Logo are registered trademarks of Bently Nevada, a
Baker Hughes Business, in the United States and other countries. The Baker Hughes logo is a trademark of Baker
Hughes Company. All other product and company names are trademarks of their respective holders. Use of the
trademarks does not imply any affiliation with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does
not make any representation as to the accuracy or completeness of the information and makes no warranties of
any kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and
fitness for a particular purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect,
consequential or special damages, claims for lost profits, or third party claims arising from the use of the
information, whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make
changes in specifications and features shown herein, or discontinue the product described at any time without
notice or obligation. Contact your Baker Hughes representative for the most current information.
The information contained in this document is the property of Baker Hughes and its affiliates; and is subject to
change without prior notice. It is being supplied as a service to our customers and may not be altered or its content
repackaged without the express written consent of Baker Hughes. This product or associated products may be
covered by one or more patents. See Bently.com/legal.
9/9