PC Mate - Feature Benefit

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Feature Benefit

650VA / 390 Watts


Load/Rating 800VA / 480 Watts Adequate wattage rating to accommodate most common PC Load
1000VA / 600 Watts

3 IEC Connectors allow connection of PC, Monitor and a third device at the same time. CABLES
Connectors 3 x IEC load connectors with battery backup
INCLUDED

Laser Printer Surge protection available for laser printer connector which safeguards printers against damage
1x IEC Laser Printer connector without battery backup
Protection due to transient surge

Audible alarm for Fault-Overload / Replace battery /


Alarm Easily identifiable and recognisable alarms
Mains fail / Low battery

PC Interface & Advanced Power Monitoring Software Monitors and records Input/Output
Monitoring
Monitoring Software included Voltages, Battery Status on UPS through Email/Pager; RS232C Serial Port Interface. Supports
Software
Windows, Novell and LINUX OS.

Hassle Free Post Sales Service (alternatively, resellers get 1% advance warranty units plus
Warranty 2-Years Swap Out (Replacement) Warranty
1% PCB with every shipment on MOQ)

Ability to start UPS when the AC mains supply is unavailable. Useful when user needs to start PC
Cold Start Cold Start Capability
when power outage has already occurred.

No DIP Switches to set voltage range. Narrower voltage range will force load to switch to battery
Voltage Input
Automatic Wide Input Voltage Range: 160-280VAC mode more frequently resulting in excess usage of charge-discharge cycle thus reducing battery life
Range
as battery life is defined in terms of number of charge-discharge cycles.

Automatic Voltage Regulator provides regulated clean power for a wide input voltage window
AVR Built-In Automatic Voltage Regulator
regulating output voltage to 220V +/-10%

Compatible with generator thus extending backup time and enhancing battery life. UPS's
Generator
Generator Compatibility incompatible with generator will sense generator input as power failure and switch to battery mode
Compatible
thus unnecessarily using up battery and reducing its life.
Protects telephone, fax and modem connected to PC against dangerous lightning strikes and
Data Line
Telephone/Modem/Fax Line Surge Protection transient surges. Also protects computer against these disturbances when connected to Internet via
Protection
modem

Electromagnetic and Radio Frequency Interferences are one of the main causes of data corruption.
EMI/RFI Full Time EMI/RFI Suppression
PC Mate UPS's eliminate high frequency electrical noises

PC Mate UPS's use quality battery ensuring high quality, deep discharge characteristics suitable for
Battery Sealed Maintenance Free (SMF) Battery
UPS C25 Applications

No Load (Green On Power Failure, UPS checks if load is connected and in the absence of connected load prevents
No Load Protection
Feature) battery from being discharged. Extends Battery Life.

You might also like