Control Equipment
Management Software Manual
CSI-200E Numerical Measuring and
Control Equipment
Management Software Manual
Version:V1.00
Doc. Code:F0SF.455.064(ER)
Issued Date:2012.09
Copyright:
All rights reserved by Beijing Sifang Automation Co. Ltd.
Dissemination or reproduction of this document, or evaluation and communication of its
contents, is not authorized except where expressly permitted. Violations are liable for damages.
All rights reserved, particularly for the purposes of patent application or trademark registration.
Disclaimer of liability :
We have checked the text of this manual against the hardware and software described.
However, deviations from the description cannot be completely ruled out, so that no liability can
be accepted for any errors or omissions contained in the information given.
The information in this manual is checked periodically, and necessary corrections will be
included in future editions. We appreciate any suggested improvements.
We reserve the right to make technical improvements without notice. If there are differences
between the product and the manual, please refer to the product. We will be very pleased if you
contact with us.
Thank you for using the products of Beijing Sifang Automation Co.,Ltd. In order to
make use of this software safely, correctly and effectively, you must pay great attention
to the following important tips:
1) This manual is only applicable to CSI-200E Manage version V2.00 of the
Management Software of CSI-200E numerical measuring and control equipment.
2) Please read this manual carefully, and regulate, test and operate the software
according to the manual. If there is any random data, please conform to them.
3) Please use qualified test kits and equipments to test and check the software.
4) If anything goes wrong or the software needs maintenance, please contact us
immediately through the service hot line.
Contents
Chapter 1 Overview ..................................................................................................................... 1
1 Overview ................................................................................................................................... 2
Chapter 2 Introduction for software window ............................................................................... 5
1 Introduction ............................................................................................................................... 6
Chapter 3 New create/open project file........................................................................................ 7
1 LCD mode selection ................................................................................................................ 8
2 Save project file........................................................................................................................ 9
3 Open project file ..................................................................................................................... 10
Chapter 4 Main-line diagram drawing ....................................................................................... 11
1 Element drawing .................................................................................................................... 12
1.1 Draw and move element............................................................................................ 12
1.2 Copy, cut, paste and select all element...................................................................... 13
1.3 Backward movement................................................................................................. 13
1.4 Element attribute setting............................................................................................ 13
2 Download main-line diagram................................................................................................ 16
3 Export as bitmap .................................................................................................................... 17
Chapter 5 PLC edition ............................................................................................................... 19
1 Classification and using rules .............................................................................................. 20
1.1 Classification for PLC node ...................................................................................... 20
1.2 Classification for operation type ............................................................................... 21
1.3 Use rules .................................................................................................................... 21
2 Programing for programable logic....................................................................................... 23
2.1 Icons for PLC toolbar ................................................................................................ 23
2.2 Branch management .................................................................................................. 23
2.2.1 Adding branch ........................................................................................................... 23
2.2.2 Edit the branch name................................................................................................. 23
2.2.3 Adding branch behind the present branch ................................................................. 23
2.2.4 Copy and delete branch ............................................................................................. 24
2.2.5 Paste branch to present branch .................................................................................. 24
2.2.6 Move up and move down branch .............................................................................. 24
2.2.7 Move all output blocks to the last.............................................................................. 24
2.3 Node management..................................................................................................... 24
2.3.1 Adding node .............................................................................................................. 24
2.3.2 Adding parallel connection node............................................................................... 25
2.3.3 Copy, cut, delete, paste and select all ........................................................................ 25
2.3.4 Replace node ............................................................................................................. 26
2.3.5 Move forward and move back node .......................................................................... 26
2.3.6 Node attribute setting ................................................................................................ 26
2.3.7 Example for PLC edition........................................................................................... 26
3 Download, upload and verify the PLC ................................................................................ 29
4 Skill for PLC programming.................................................................................................... 30
5 Perform remote control function by PLC ............................................................................ 31
5.1 Common remote control............................................................................................ 31
5.2 Perform remote control by time relay ....................................................................... 31
5.3 Perform remote control by pulse relay ...................................................................... 32
6 Perform synchronization function by PLC.......................................................................... 33
7 Perform voltage regulation function by PLC ...................................................................... 38
8 Bay five protection blocking performed by PLC ................................................................ 39
9 Export as bitmap from latter diagram.................................................................................. 42
10 Export as text from PLC binary output logic............................................................... 43
Chapter 6 Device configuration ................................................................................................. 45
1 Device setting ......................................................................................................................... 46
2 Configuration module ............................................................................................................ 47
2.1 Configuration binary input module ........................................................................... 47
2.2 Configuration analog input module........................................................................... 47
2.3 Configuration the DC/temperature module ............................................................... 48
3 Configuration channel ........................................................................................................... 49
3.1 Attribute configuration for each channel in binary input module ............................. 49
3.2 Each channel attribute configuration for AI module ................................................. 50
3.3 Each channel attribute configuration for DC/temperature module ........................... 52
4 Cycle display configuration................................................................................................... 53
5 Blocking analog quantity configuration ............................................................................... 54
6 Download the device configuration setting ........................................................................ 55
Chapter 7 Wire connection mode of serial port ......................................................................... 57
Chapter 1 Overview
Chapter 1 Overview
1
Chapter 1 Overview
1 Overview
CSI-200EManage is used as auxiliary management software of PC
(hereinafter is referred as software or version 2.00) for CSI-200E series
comprehensive measurement and control device (hereinafter is referred as
device or bay).
The bay main-line can be drawn by software to be applied for display in HMI.
The required element (circuit breaker, disconnector, reactor, capacitor,
connection wiring) can be selected from element library by user to draw
main-line diagram and define the attribute of each element (controlled,
dynamic state, static state) according to different bay requirement. The
software converts to main-line diagram configuration table code which can be
identified by device, and input to device through RS-232 port in panel, the bay
main-line diagram will be display in HMI, local operation can be performed if
cooperate with local operation button.
Device “five protection” logic blocking, bays “five protection” logic blocking,
switch off/on, disconnector, closing with synchronization check, CB open
alarm function, etc., which can be performed by PLC programmable control
logic in device. It is not required to perform any program by user and engineer,
the ladder diagram can be edited according to requirement through software
graphic logic editor. The corresponding function can be performed after the
diagram downloaded to device via serial port.
z Device configuration
2
Chapter 1 Overview
z 61850 mapping
For version V2.50 and above, add the function of 61850 mapping, to perform
mapping relation of IEC61850 information and the corresponding device
configuration.
3
Chapter 1 Overview
4
Chapter 2 Introduction for software window
5
Chapter 2 Introduction for software window
1 Introduction
Three function modules included: main-line diagram drawing, PLC editor and
device configuration, each module is corresponding to a view window, the
function module can be switched by user through the button of “Device
management guide bar” at left side of software window or the corresponding
option of “View”.
Only one device can be configured by software once, the main-line diagram,
PLC and device configuration information will be saved to one file. In order to
discriminate from version V1.X file CSI, CSI2 is used from version V2.00.
6
Chapter 3 New create/open project file
7
Chapter 3 New create/open project file
Three types device for CSI-200E series, as shown in the following table:
8
Chapter 3 New create/open project file
Only one bay can be configured by software once, the main-line diagram,
PLC and device configuration will be saved to one file.
9
Chapter 3 New create/open project file
z CSI file for V1.22: main-line diagram and PLC are saved as CSI file,
device configuration is saved as dat file; select “File/Open” and prompt
information will appear when save file. If save file, the format will be
changed, and the software of V1.22 cannot be opened, before
transformation, it is better to backup the original file; operation method for
dat file is same as described above.
10
Chapter 4 Main-line diagram drawing
11
Chapter 4 Main-line diagram drawing
1 Element drawing
All of the required elements for main-line diagram drawing in “Draw” menu, in
order to be convenient for drawing, the corresponding button of these
elements are included in toolbar.
When drawing the busbar or dashed box, it is required to left-click mouse and
move mouse simultaneously to determine the element size; textbox size can
be adjusted automatically based on the length and height of text content,
which cannot be adjusted manually.
12
Chapter 4 Main-line diagram drawing
In the menu of “Edit”, operation of cut, copy and delete are used for selected
element; paste operation is used to paste element to main-line diagram from
clipboard, and copy selected element to clipboard; select all function is to
select all of the elements in main-line diagram. These operations are same as
most of other software, including shortcut key, so using these operations to
draw main-line diagram like writing WORD document. However, the “Cancel”
function is not supported in version V2.00, so, pay attention to the “Delete”
operation specially.
Special operation
If re-draw the main-line diagram instead of new create, “Select All” and
then “Delete”.
If two of the manage software are running at the same time, copy
elements of main-line diagram from one software and then paste to
another software, it is convenient to copy the existed main-line diagram
to new created main-line diagram.
When drawing elements, the latest drawn element is on the top of previous
drawn element generally, so, if the latest drawn element is not moved, the
previous drawn element cannot be selected. If the drawn transformer element
is surrounded by dashed box and the dashed box is drawn later, although the
transformer element is displayed normally, it cannot be selected. In order to
solve this problem, add the menu of “Draw/Move Back”, it is applied to move
back the top element, and the previous drawn element can be selected.
For version V2.00, busbar and dashed box without attribute setting, other
element attribute can be set. Double-click the selected element and pop up
the corresponding attribute setting box, confirm and exit after setting.
13
Chapter 4 Main-line diagram drawing
14
Chapter 4 Main-line diagram drawing
The position displayed in attribute box is the upper left position of element to
main-line diagram.
15
Chapter 4 Main-line diagram drawing
The default serial port is COM1, select other serial port through menu
“Tools/Config Serial Port”, but the other parameter of serial port are set by
software automatically.
The present view must be “Main-line diagram drawing” and the serial port is not opened,
select menu of “Tools/Download Outline Diagram” or click the button in toolbar to begin to
download the main-line diagram, the serial port will be closed automatically after
downloading finished. When downloading, various kinds of information during downloading
are displayed at information bar, including downloading element symbol, line drawing,
letter symbol, other drawings, element attribute, and downloading success or failure
information, and so on; sending or receiving report by serial port displayed in report
window, sending and receiving time displayed at the head of each frame of report,
accurate to the millisecond.
16
Chapter 4 Main-line diagram drawing
3 Export as bitmap
The present view must be main-line diagram, select menu of “File/Save As
Bmp File” to export main-line diagram as the bitmap file, browse or print the
file with other drawing software. The bitmap file is necessary when
exchanging information or document processing with user.
17
Chapter 4 Main-line diagram drawing
18
Chapter 5 PLC edition
19
Chapter 5 PLC edition
20
Chapter 5 PLC edition
Operation object include output relay, auxiliary relay, time relay, pulse
relay, relay command determination relay.
CJP operation Jump statements, screen some statements of latter diagram through
some external inputs. (skip the following logic branches).
z “And” logic for different input block in the same branch, “or” logic for
different nodes in the same branch.
z Many input blocks can be included in one branch, and many nodes can
be included in one input block; only one output block can be included in
21
Chapter 5 PLC edition
z If the input block is physical node, which can be selected as binary input
node, AC node and DC node; if the output block is physical node, it is
only can be selected as binary output node.
z For drawing mode PLC editor in version V2.00, the last node and the
parallel connection node of one branch is defined as output block.
22
Chapter 5 PLC edition
Switch the present window into PLC editor through the guide bar of device
management. If the file is new created, there is no branch and node in editor.
Complete the latter diagram visually through editor toolbar or the
corresponding item in PLC menu.
When edit the PLC, besides the “PLC” menu and the operation in above
toolbar, the operation of copy, paste, delete and cut for node can be
performed in “Edit” menu.
Add a new branch at the end of the present PLC drawing all the time. The
program adds two undefined nodes by default to this branch. The default
branch named as “Undefined branch”, double click the branch name, and pop
up the dialog box of attribute setting (only support to edit the branch currently).
Input the required branch name in dialog box, confirm and exit.
The software will perform sequence number from top to bottom to the added
branch.
When the mouse move across the branch name, the mouse arrow changes to
hand shape, single-click branch name at this time, the branch can be selected.
Only one branch can be selected at one time. Two grey line under the
selected branch name. Double-click the branch name, to open the name
edition box of branch, input the required branch name in the box, confirm and
exit.
23
Chapter 5 PLC edition
The present branch is the selected branch, the command is valid only after
one branch has been selected. Select the menu of “Add branch behind the
present branch” or click editor toolbar to add a new branch behind the
selected branch, the other branches behind the selected branch will move
down one branch position, the software will perform new sequence number to
all branches again, other attribute for all branches are not changed.
Copy and delete to the selected branch. After delete one branch, the software
will arrange all branches and new sequence number. The operation for delete
branch cannot be reversed.
Paste branch to the position behind present selected branch from clipboard.
The software will rearrange the sequence number again after pasting. The
precondition for this command is that the node number in clipboard must be
large than 1. That means, the branch number must be large than 1 when copy
branch, or the node must be large than 1 when copy node.
The operation of move up is to change the position with the branch above the
selected branch. The operation of move down is to change the position with
the branch under the selected branch. The software will rearrange all
branches and sequence number after moving.
Move the last output block of all branches to the last of the branch.
Add node to the selected branch. According to the rules, the last node and
parallel connection node are output blocks, considering the correctness of
24
Chapter 5 PLC edition
PLC edition, add new node behind the last node all the time. If require to
change output block, which can be performed by move left or move right.
Single-click node by mouse can select node. There is dotted box around the
selected node.
If need to add node behind a certain node, select the node first, and then add
node. The selected node must be in the present branch.
If the node in block is selected, the parallel node can be added for this block.
Node management
These are command in “Edit” menu, the first three commands are to operate
to selected node;
25
Chapter 5 PLC edition
If copy and paste node 1 to the behind of node 2, select node 1 first, copy and
then select node 2 and paste.
Move left or move right of the selected node. Only support to move the branch
node namely the node in branch main line.
Double-click node, pop up the node attribute setting box, setting the node
attribute according to requirement.
In the node attribute box, the restore button is used to set the attribute box as
saved attribute value of node; the original attribute value is saved attribute
value of node. After attribute setting, confirm and exit.
The name of first node is “(1G) disconnector remote control off 0”, the
attribute is set as common logic node, remote control relay, is remote control
tripping relay, operation type is output, normal open node, the node sequence
number is 1;
The name of second node is “(1G) disconnector remote control on 0”, the
attribute is set as common logic node, remote control relay, is remote control
closing relay, operation type is output, normal close node, the node sequence
number is 1;
The name of third node is “binary output”, set the attribute as physical node,
binary output module, node sequence number is 1, and displaying type is
switch.
z Switch the present window into PLC editor, select the menu “Edit/Select
All”, and select all the nodes;
z Delete all the nodes in PLC, prepare to edit a new PLC latter diagram;
z Add a new branch, double-click branch name, and change the branch
name as “1G disconnector”.
z Select the added disconnector, and add a node in the present branch.
z Double-click the first node and edit the node attribute. Input the node
name first, and then select node type, at the end set the node, after
setting finished, confirm and exit, the setting will be valid.
27
Chapter 5 PLC edition
28
Chapter 5 PLC edition
29
Chapter 5 PLC edition
z When require to output time delay contact, the time relay can be adopted
z Time parameter for time relay and pulse relay is set with step 10ms.
z Before downloading PLC logic, the control logic linker must be disabled.
30
Chapter 5 PLC edition
1) Receiving the remote control command, the binary outputs are driven by
remote control command relay;
2) The related remote signal return, drive the corresponding remote control
command determination relay;
If the remote signal is not returned within 15s, the remote control command
will return automatically. Applied for the condition for which the related remote
signal can be returned within 15s.
1) Receiving the remote control command, the binary outputs and time relay
are driven by remote control command relay;
31
Chapter 5 PLC edition
2) The setting time of time relay elapse, drive the corresponding remote
control command determination relay.
The time delay of time relay can be set, the setting range is 10ms~15ms,
applied for the condition for which the time of binary output is less than 15ms
fixedly or no corresponding remote signal return.
1) Receiving the remote control command, the pulse relay and the
corresponding remote control command determination relay are driven
by remote control command relay;
32
Chapter 5 PLC edition
The latching time can be set for pulse relay output, the setting range is
10ms~10min, applied for the condition for which the binary output time is
required for long. If the binary output is required for closing for long term, the
double position DOB module should be adopted.
Connection mode
c) Energizing-check linker;
33
Chapter 5 PLC edition
2) The voltage difference and angle difference of both sides should be less
than setting.
Under the condition that the condition described above are met, the device
will capture 0° closing angle automatically, issue the closing command at 0°
closing angle, the calculation equation for closing angle:
e), f), g), h), i), j), k) are selection linker for synchronization, only one can be
enabled, the others disabled automatically. If it is fixed voltage mode, the
34
Chapter 5 PLC edition
device is in linker status. If the near zone priority rule is adopted, the device
issue closing command after power on, disable all the linker that applied for
near zone priority rule.
Take into account of the external linker applied for synchronization mode
somewhere instead of logical linker and define the synchronization relay as
follows:
When the binary input and other input blocking satisfy with conditions, output
synchronization relay 0 first, and then drive binary output by synchronization
node, complete the operation of circuit breaker closing manually based on
synchronization-check.
c) Two closing operation for same circuit breaker, direct closing and closing
35
Chapter 5 PLC edition
In the above diagram, when the synchronization linker enabled and receiving
remote control command 4, output one synchronization relay according to
PLC, at this time, the MASTER module send synchronization command to AI
module, the AI module begin to distinguish the synchronization condition
based on setting after receiving synchronization command, if the condition
satisfied, output binary output. This mode equal to close with
synchronization-check. When the synchronization linker disabled and
receiving remote control command 4, it is not required to perform
synchronization-check operation, output binary output directly. This mode
equal to close directly.
g) Measured value of voltage and frequency of local side and opposite side
36
Chapter 5 PLC edition
37
Chapter 5 PLC edition
c) After the voltage regulation allowance position setting to 1, the first group
of first binary input module used as position input of transformer, the
present position can be got by monitoring system through the 4f report
sent by device.
d) The three states of Up, down and stop for voltage regulation are
corresponding to remote control object number 1, 2, 3, the binary output
object can be configured flexibly by PLC logic. In order to distinguish the
common binary output, add a pulse relay and reset command relay in
PLC logic. As the following diagram:
38
Chapter 5 PLC edition
Select the menu of “PLC/Config Interlock Device Address” to enter into the
window of configuring the blocking device.
39
Chapter 5 PLC edition
binary input quantity information from which device, binary input quantity
group number means that the configured binary input quantity group number
in the device of corresponding address, the binary input number is 4 when the
device is configured to 24 channels of binary input; the binary input number is
6 when the device is configured to 34 channels of binary input. One device
can receive the binary input quantity information from 16 devices at most.
40
Chapter 5 PLC edition
41
Chapter 5 PLC edition
42
Chapter 5 PLC edition
2. Open the measure and control device configuration file *.CSI2 of the
corresponding bay, the PLC latter diagram of this bay can be observed in
PLC editor;
If the measure and control device has been connected, select “Check PLC” in
the menu of “Tools”, the PLC will be uploaded to device, and check the
uploaded PLC with the opened PLC in the above procedure, the checking
result will prompt accordance or discordance.
43
Chapter 5 PLC edition
44
Chapter 6 Device configuration
45
Chapter 6 Device configuration
1 Device setting
Switch the present window into device setting through device management
guide bar. Only one device can be configured in version V2.00 at one time.
Device configuration
Device setting
46
Chapter 6 Device configuration
2 Configuration module
In configuration table, some items are dropdown list box, namely click the
table, the dropdown list will pop up, and select the required item, for example
the CPU address; some items need to be input; and some items read-only,
for example the Chinese ID. When configuring the “Binary input module”,
select the CPU address (note: the address only can be selected from small to
large according to CPU module number, AI module and DC module are
same), fill in the channel number of CPU module. At most two double binary
input modules can be configured for one device, and totally 96 channels of
binary input. The channel number means that the binary input number,
common binary input is 24, the channel number of double binary input (add a
extension module without CPU in common module) module is two times of
common binary input module (48).
After CPU address selected, and input the channel number, click “Refresh
record/Save”. And then switch into other zones through device configuration
guide bar.
47
Chapter 6 Device configuration
The configuration method is same as binary input module, and at most three
AI modules can be configured for one device.
The channel numbers of CPU module include the actual physical channel
(connected voltage and current with external terminal) and the virtual channel
(for example: line voltage calculated by phase voltage, active power P,
reactive power Q, power factor cosφ, frequency f and general node). The
ration of large CT and large PT is the transformation ration of primary side to
secondary side in primary equipment (i.e. 600/5, 200kV/100), the small CT
transformation ratio is the CT specification in device (5A or 1A).
Configuration AI module
The method is same as “Binary input module”, the channel number is actual
physical channel, including DC measurement and temperature measurement.
At most two DC modules can be configured for one device.
48
Chapter 6 Device configuration
3 Configuration channel
After the device setting and each function module configuration finished,
enter into channel configuration. Select the corresponding channel in the
channel configuration in device configuration guide bar, switch into the
configuration zone of the corresponding channel. If the function module
corresponding to the channel is not configured, switching fail. So, the function
module should be configured first, and then configure the corresponding
channel.
Binary input group attribute is the attribute definition of binary input terminal,
including transformer position, pulse power, single and double position
remote signal, and disable. The attribute must be whole group definition, a
basic binary input module includes 4 group of binary input without same
grounded of common terminal, and the binary input channel number is 8, 4, 8,
4 in proper sequence for each group of binary input, the basic binary input
module with extension module consist of eight group of channel that is shown
in figure 24.
Note: only the first group and third group binary input in first binary input
module can be set as transformer position. If the position input cannot use 8
binary inputs, the rest of binary input cannot be used for other purpose.
If the voltage regulation with separate phase, need to set the first group and
third group in first binary input module as transformer position, and at the
same time, need to set the control word D13 of voltage regulation as voltage
regulation with separate phase.
49
Chapter 6 Device configuration
Channel attribute is the physical meaning for the channel, need to fill in, the
power measurement point sequence number is power group sequence
number, beginning from 0, (power group sequence number for first AI module
is 0~3, the second module is 4~7 and the third module is 8~11). When the
channel is voltage or current, the basic node phase sequence must fill in, if
the channel is other content, don’t need to fill in. The Chinese ID don’t need to
be filled in manually, the software will fill in automatically when “Refresh
channel”.
The channel attribute: the first 12 channels are physical channel configuration
of AI module. Configuration based on the connected voltage or current. The
hardware version of 8U4I and 6U6I: 8U4I means that 1, 2, 3, 7, 8, 9, 11, 12
are voltage channel, the other channels are current channel; 6U6I means that
1, 2, 3, 7, 8, 9 are voltage, and the others are current. So, need to configure
as voltage/current or disable. But, when calculate the total channels, the
channels are involved whatever the channel enabled or disabled.
The typical configuration for two types of AI module, refer to the following
table. Select the menu of “Device/AC Unit Channel 8U4I” or click the toolbar
button to configure the AI module channel as typical configuration 8U4I.
Configure 6U6I with same method.
8U4I 6U6I
External Inter Channel Power External Inter Channel Power
terminal channel attribute sequence terminal channel attribute sequence
number number number number number number
U1A 1 Voltage/ 0 U1A 1 Voltage/ 0
disable disable
U1B 2 Voltage/ 0 U1B 2 Voltage/ 0
50
Chapter 6 Device configuration
disable disable
U1C 3 Voltage/ 0 U1C 3 Voltage/ 0
disable disable
I1A 4 Current/ 0 I1A 4 Current/ 0
disable disable
I1B 5 Current/ 0 I1B 5 Current/ 0
disable disable
I1C 6 Current/ 0 I1C 6 Current/ 0
disable disable
U2A 7 Voltage/ 1 U2A 7 Voltage/ 1
disable disable
U2B 8 Voltage/ 1 U2B 8 Voltage/ 1
disable disable
U2C 9 Voltage/ 1 U2C 9 Voltage/ 1
disable disable
I10 10 Current/ 0 I2A 10 Current/ 1
disable disable
U3 11 Voltage/ 2 I2B 11 Current/ 1
disable disable
U4 12 Voltage/ 3 I2C 12 Current/ 1
disable disable
U1AB 13 Voltage 0 U1AB 13 Voltage 0
U1BC 14 Voltage 0 U1BC 14 Voltage 0
U1CA 15 Voltage 0 U1CA 15 Voltage 0
U2AB 16 Voltage 1 U2AB 16 Voltage 1
U2BC 17 Voltage 1 U2BC 17 Voltage 1
U2CA 18 Voltage 1 U2CA 18 Voltage 1
P1 19 Active 0 P1 19 Active 0
power power
Q1 20 Reactive 0 Q1 20 Reactive 0
power power
cosφ 21 Power 0 F1 21 Frequency 0
factor
F1 22 Frequency 0 cosφ1 22 Power 0
factor
F2 23 Frequency 1 P2 23 Active 1
power
F3 24 Frequency 2 Q2 24 Reactive 1
power
F4 25 Frequency 3 F2 25 Frequency 1
26 cosφ2 26 Power 1
factor
51
Chapter 6 Device configuration
52
Chapter 6 Device configuration
Note: the “Channel name” in MMI cycle display only can be selected, the
Chinese ID is filled in automatically. At most 40 channels in MMI cycle
display can be configured.
53
Chapter 6 Device configuration
54
Chapter 6 Device configuration
The report of each item can be issued separately through the menu of
“Device”.
55
Chapter 6 Device configuration
56
Chapter 7 Wire connection mode of serial port
57
Chapter 7 Wire connection mode of serial port
58