PV Elite 2019 Licensee

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

1

Element and Detail Weights:

| | Element | Element | Corroded | Corroded | Extra due |


From| To | Metal Wgt. | ID Volume |Metal Wgt. | ID Volume | Misc % |
| | lb. | In. | lb. | In. | lb. |
---------------------------------------------------------------------------
10| 20| 10769.2 | ... | 10769.2 | ... | ... |
20| 30| 1635.54 | 73287.1 | 1499.24 | 73626.9 | ... |
30| 40| 5530.14 | 464151 | 5073.65 | 465764 | ... |
40| 50| 4561.78 | 460243 | 4109.14 | 461842 | ... |
50| 60| 3643.14 | 460243 | 3190.5 | 461842 | ... |
60| 70| 3643.14 | 460243 | 3190.5 | 461842 | ... |
70| 80| 3643.14 | 460243 | 3190.5 | 461842 | ... |
80| 90| 3643.14 | 460243 | 3190.5 | 461842 | ... |
90| 100| 3643.14 | 460243 | 3190.5 | 461842 | ... |
100| 110| 3674.08 | 464151 | 3217.59 | 465764 | ... |
110| 120| 737.717 | 61072.6 | 614.764 | 61369.9 | ... |
---------------------------------------------------------------------------
Total | 45124 | 3824119 | 41236 | 3837579 | 0 |

Weight of Details:

| | Weight of | X Offset, | Y Offset, |


From|Type| Detail | Dtl. Cent. |Dtl. Cent. | Description
| | lb. | ft. | ft. |
-------------------------------------------------
10|Insl| 15639.8 | ... | 9.25 | SKIRT INS.
10|Forc| ... | ... | ... | FORCE ON SKIRT
20|Liqd| 2035.75 | ... | -0.75 | LIQUID
20|Insl| 55.167 | ... | -0.5 | BOT HEAD INS
20|Wght| 200 | ... | ... | WEIGHT HEAD
20|Forc| ... | ... | ... | HEAD FORCE
30|Liqd| 2712.92 | ... | 4.75 | LIQUID 2
30|Insl| 186.532 | ... | 4.75 | INSULATION
30|Wght| 2422.5 | ... | 4.75 | WEIGHT
30|Forc| ... | ... | 4.75 | FORCE 1
40|Insl| 184.345 | ... | 4.71 | INSULATION
40|Wght| 4568.7 | ... | 4.71 | WEIGHT 2
40|Forc| ... | ... | 4.71 | FORCE 2
50|Insl| 183.728 | ... | 4.71 | INSULATION
50|Ring| 136.917 | ... | 1.09 | RING FROM 50
50|Wght| 4239 | ... | 4.71 | FORCE 3
50|Forc| ... | ... | 4.71 | FORCE 3
60|Insl| 183.728 | ... | 4.71 | INSULATION
60|Ring| 136.917 | ... | 7.67 | RING FROM 60
60|Wght| 4945.5 | ... | 4.71 | WEIGHT 4
60|Forc| ... | ... | 4.71 | FORCE 4
70|Insl| 183.728 | ... | 4.71 | INSULATION
70|Wght| 4427.4 | ... | 4.71 | WEIGHT 5
70|Forc| ... | ... | 4.71 | FORCE 5
80|Insl| 183.728 | ... | 4.71 | INSULATION
80|Ring| 136.917 | ... | 8.84 | RING FROM 80
80|Wght| 4239 | ... | 4.71 | WEIGHT 6
80|Forc| ... | ... | 4.71 | FORCE 6
90|Insl| 183.728 | ... | 4.71 | INSULATION
90|Wght| 4239 | ... | 4.71 | WEIGHT 7
90|Forc| ... | ... | 4.71 | FORCE 7
2

100|Insl| 185.289 | ... | 4.75 | INSULATION


100|Wght| 4512.5 | ... | 4.75 | WEIGHT 8
100|Forc| ... | ... | 4.71 | FORCE 8
110|Insl| 49.5242 | ... | 0.875 | INSULATION
110|Wght| 200 | ... | 0.25 | WEIGHT TOP
-------------------------------------------------

Total Weight of Each Detail Type:

Liquid 4748.7
Insulation 17219.3
Stiffeners 410.8
Weights 33993.6
-------------------------------------------
Sum of the Detail Weights 56372.3 lb.

Weight Summation Results: (lb.)

| Fabricated | Shop Test | Shipping | Erected | Empty | Operating |


---------------------------------------------------------------------------------------------
Main Elements | 45124.2 | 45124.2 | 45124.2 | 45124.2 | 45124.2 | 45124.2 |
Stif. Rings | 410.8 | 410.8 | 410.8 | 410.8 | 410.8 | 410.8 |
Insulation | ... | ... | 17219.3 | 17219.3 | 17219.3 | 17219.3 |
Ope Weights | ... | ... | ... | ... | ... | 33993.6 |
Ope. Liquid | ... | ... | ... | ... | ... | 4748.7 |
Test Liquid | ... | 138093.2 | ... | ... | ... | ... |
---------------------------------------------------------------------------------------------
Totals | 45534.9 | 183628.1 | 62754.2 | 62754.2 | 62754.2 | 101496.5 |

Field Installation Options:

Weight Summary:

Fabricated Wt. - Bare Weight without Removable Internals 45534.9 lb.


Shop Test Wt. - Fabricated Weight + Water ( Full ) 183628.1 lb.
Shipping Wt. - Fab. Weight + removable Intls.+ Shipping App. 62754.2 lb.
Erected Wt. - Fab. Wt + or - loose items (trays,platforms etc.) 62754.2 lb.
Ope. Wt. no Liq - Fab. Weight + Internals. + Details + Weights 62754.2 lb.
Operating Wt. - Empty Weight + Operating Liq. Uncorroded 101496.5 lb.
Field Test Wt. - Empty Weight + Water (Full) 200847.4 lb.
Mass of the Upper 1/3 of the Vertical Vessel 25217.6 lb.

Outside Surface Areas of Elements:

| | Surface |
From| To | Area |
| | sq.in. |
----------------------------
10| 20| 51261.4 |
20| 30| 7241.4 |
30| 40| 26323.4 |
40| 50| 26013 |
50| 60| 25924.2 |
60| 70| 25924.2 |
70| 80| 25924.2 |
80| 90| 25924.2 |
90| 100| 25924.2 |
100| 110| 26144.3 |
110| 120| 6422.71 |
----------------------------
Total 273027.062 sq.in. [1896.0 Square Feet ]
3

Element and Detail Weights:

| To | Total Ele.| Total. Ele.|Total. Ele.| Total Dtl.| Oper. Wgt. |


From| To | Empty Wgt.| Oper. Wgt.|Hydro. Wgt.| Offset Mom.| No Liquid |
| | lbm | lbm | lbm | ft.lb. | lbm |
---------------------------------------------------------------------------
10| 20| 26409 | 26409 | 26409 | ... | 26409 |
20| 30| 1690.71 | 3926.46 | 4337.18 | ... | 1890.71 |
30| 40| 5716.67 | 10852.1 | 22477.7 | ... | 8139.17 |
40| 50| 4746.13 | 9314.83 | 21366 | ... | 9314.83 |
50| 60| 3963.78 | 8202.78 | 20583.7 | ... | 8202.78 |
60| 70| 3963.78 | 8909.28 | 20583.7 | ... | 8909.28 |
70| 80| 3826.87 | 8254.27 | 20446.7 | ... | 8254.27 |
80| 90| 3963.78 | 8202.78 | 20583.7 | ... | 8202.78 |
90| 100| 3826.87 | 8065.87 | 20446.7 | ... | 8065.87 |
100| 110| 3859.37 | 8371.87 | 20620.4 | ... | 8371.87 |
110| 120| 787.242 | 987.242 | 2992.64 | ... | 987.242 |
---------------------------------------------------------------------------

Empty Support Force + the Sum of the Y forces 76034.20 lb.


Operating Support Force + the Sum of the Y forces 114776.46 lb.
Hydro Support Force + the Sum of the Y forces 214127.38 lb.

Cumulative Vessel Weight

| | Cumulative Ope | Cumulative | Cumulative |


From| To | Wgt. No Liquid | Oper. Wgt. | Hydro. Wgt. |
| | lbm | lbm | lbm |
-------------------------------------------------------
10| 20| 96747.8 | 101496 | 200847 |
20| 30| 70338.8 | 75087.5 | 174438 |
30| 40| 68448.1 | 71161 | 170101 |
40| 50| 60308.9 | 60308.9 | 147624 |
50| 60| 50994.1 | 50994.1 | 126257 |
60| 70| 42791.3 | 42791.3 | 105674 |
70| 80| 33882 | 33882 | 85090.2 |
80| 90| 25627.8 | 25627.8 | 64643.4 |
90| 100| 17425 | 17425 | 44059.8 |
100| 110| 9359.11 | 9359.11 | 23613 |
110| 120| 987.242 | 987.242 | 2992.64 |
-------------------------------------------------------

Note: The cumulative operating weights no liquid in the column above


are the cumulative operating weights minus the operating liquid
weight minus any weights absent in the empty condition.

Cumulative Vessel Moment

| | Cumulative | Cumulative |Cumulative |


From| To | Empty Mom. | Oper. Mom. |Hydro. Mom.|
| | ft.lb. | ft.lb. | ft.lb. |
-------------------------------------------------
10| 20| ... | ... | ... |
20| 30| ... | ... | ... |
30| 40| ... | ... | ... |
40| 50| ... | ... | ... |
50| 60| ... | ... | ... |
60| 70| ... | ... | ... |
70| 80| ... | ... | ... |
80| 90| ... | ... | ... |
90| 100| ... | ... | ... |
100| 110| ... | ... | ... |
4

110| 120| ... | ... | ... |


-------------------------------------------------

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019