Professional Documents
Culture Documents
Creep and Shrinkage Behavior of High-Strength Concrete and Minimum Reinforcement Ratio For Bridge Columns
Creep and Shrinkage Behavior of High-Strength Concrete and Minimum Reinforcement Ratio For Bridge Columns
Creep and Shrinkage Behavior of High-Strength Concrete and Minimum Reinforcement Ratio For Bridge Columns
and shrinkage
behavior of
high-strength
concrete
and minimum
reinforcement
ratio
for bridge
columns
Halit Cenan Mertol,
Sami Rizkalla, Paul Zia,
and Amir Mirmiran
Concrete Concrete
Target concrete Concrete age at Applied
Set Rack Curing type strength at 28 strength at
strength, ksi loading, days stress, ksi
days, ksi loading, ksi
10Rack3 28 12.1
1 10
10Rack4 7-day moist 12.1 8 8.3
10Rack6 28 12.1
14Rack3 28 15.7
2 14
14Rack4 7-day moist 15.7 7 11.4
14Rack6 28 15.7
18Rack3 28 16.7
3 18
18Rack4 7-day moist 16.7 7 12.0
18Rack6 28 16.7
The volume of hardened concrete reduces in time due to tions, and cracking of prestressed concrete structures.
the loss of moisture content known as shrinkage. There are Many current code equations for creep and shrinkage
three types of concrete shrinkage: predictions are based on normal-strength concrete. Due
to the lack of research data on the creep and shrinkage
• Drying shrinkage occurs because of the loss of mois- characteristics of HSC, many design codes limit its use for
ture content from hardened concrete under drying con- concrete structures.
ditions. This process is partially irreversible. Even if
the concrete is placed in a high-humidity environment, The creep and shrinkage prediction methods specified by
not all of the drying shrinkage will be prevented. the American Association of State Highway and Transpor-
tation Officials’ AASHTO LRFD Bridge Design Specifica-
• Autogenous (chemical) shrinkage occurs because of tions1 were based on the research conducted by Tadros et
the removal of internal water as a result of the hydra- al.2 AASHTO compared the equations used in the methods
tion of the cement. of Tadros et al. with the available domestic and foreign
literature, including methods currently used for creep and
• Carbonation shrinkage occurs because of the car- shrinkage predictions. The estimated results from Tadros
bonation of the hydration products in the presence of et al. were more accurate and realistic than those provided
carbon dioxide in a low–relative humidity RH environ- by the existing methods in the literature.
ment.
This paper summarizes the findings of an extensive re-
Information on creep and shrinkage of concrete is neces- search program to examine the shrinkage and creep behav-
sary to determine the prestress losses, long-term deforma- ior of HSC with strengths up to 18 ksi (124 MPa), extend-
PCI Journal | S u m m e r 2 0 1 0 3
Table 2. Test matrix for shrinkage
prismatic specimens measuring 3 in. × 3 in. × 11¼ in. (75
Target mm × 75 mm × 290 mm). Thirty-six cylindrical specimens
Specimen
Set Specimen Curing type concrete were used to determine the creep of HSC, of which two
type
strength, ksi specimens were used in each creep test. Six cylindrical
specimens and the eighteen prismatic specimens were used
10SP1
to evaluate the shrinkage of HSC. Tables 1 and 2 show the
10SP2 1-day heat test matrix for this program.
10SP3 Materials
Prismatic
10SP4
1 10 Logan3 developed mixture proportions (Table 3) for the
10SP5 7-day moist three target concrete compressive strengths of 10 ksi, 14
ksi, and 18 ksi (69 MPa, 97 MPa, and 124 MPa).
10SP6
The coarse aggregate used in all mixtures was crushed
10SC1 1-day heat stone with a nominal maximum size of 3/8 in. (10 mm).
Cylindrical
10SC2 7-day moist Depending on the target compressive strength, one of two
types of fine aggregate was used: natural sand or manu-
14SP1 factured sand. The cement was Type I/II and the mixture
included silica fume, fly ash, a high-range water-reducing
14SP2 1-day heat admixture (HRWRA), and a retarding admixture to reduce
14SP3
the water-cement ratio w/c and enhance workability.
Prismatic
14SP4 Three 4 in. × 8 in. (100 mm × 200 mm) cylinders were
2 14 tested for each specimen to determine the compressive
14SP5 7-day moist strength at the time of testing.
14SP6
Test method and setup
14SC1 1-day heat
Cylindrical Two different curing conditions were used in this inves-
14SC2 7-day moist tigation: 1-day heat curing and 7-day moist curing. The
1-day heat curing simulated the fabrication process in
18SP1
precast, prestressed concrete plants. Half an hour after
18SP2 1-day heat casting, specimens for 1-day heat curing were placed in an
environmental chamber for 24 hr, where the temperature
18SP3 was controlled to achieve internal concrete temperatures
Prismatic from 150 °F to 160 °F (66 °C to 71 °C). The cylindrical
18SP4
3 18 molds were covered with plastic lids and the prismatic
18SP5 7-day moist molds were wrapped with wet burlap and plastic sheets to
prevent moisture loss throughout the heat-curing process.
18SP6 At the end of 24 hr, the specimens were removed from the
molds and stored in the laboratory, where the temperature
18SC1 1-day heat was maintained at about 72 °F (22 °C) with 50% RH.
Cylindrical
18SC2 7-day moist
The 7-day moist curing represented typical curing proce-
Note: 1 ksi = 6.895 MPa. dures for reinforced concrete members. These specimens
were kept in molds at room temperature for 24 hr. The
cylindrical molds were covered with plastic lids, and the
ing the database of Tadros et al. The creep and shrinkage prismatic molds were covered with wet burlap and plastic
predictions derived from the current AASHTO LRFD sheets to prevent moisture loss. After 24 hr, the speci-
specifications and the predictions’ applicability to HSC for mens were removed from their molds and submerged in
concrete strengths up to 18 ksi (124 MPa) were examined. a water-curing tank. The water temperature in the curing
tank was maintained at 73.5 °F ± 3.5 °F (23 °C ± 2 °C)
Experimental investigation using specially designed heaters equipped with adjustable
thermostats. The water was saturated with lime to prevent
The test program consisted of 42 cylindrical specimens leaching of calcium hydroxide from the test specimens.
measuring 4 in. × 12 in. (100 mm × 300 mm) and 18 The curing tanks also contained pumps that circulated the
PCI Journal | S u m m e r 2 0 1 0 5
Creep test Shrinkage test
Figure 1. Creep tests were performed using the 4 in. × 12 in. cylindrical specimens, and shrinkage tests used 3 in. × 3 in. × 111/4 in. prismatic specimens.
Note: 1 in. = 25.4 mm.
Table 4 lists the creep and shrinkage prediction equations RH for comparison purposes. Mertol gives details of this
given by the AASHTO LRFD specifications. procedure.5
t
Time-development factor ktd ktd =
61− 4 × fci' +t
Humidity factor khs and khc k hs = 2.00 − 0.0143RH for shrinkage strain, k hc = 1.56 − 0.008RH for creep coefficient
1064 − 94V / S
Size factor ks kf =
735
5
Concrete strength factor kf kf =
1+ f ci'
Note: Ag = gross area of the section; Aps = area of prestressing steel; As = area of mild compression steel; f c' = concrete compressive strength in ksi;
f c' i = specified compressive strength at prestress transfer for prestressed members or 80% of the strength at service for nonprestressed members in
ksi, fpe = effective prestress after losses; fpu = specified tensile strength of prestressing steel; fy = yield strength of mild steel; K1 = correction factor
for source of aggregate (taken as 1.0); RH = relative humidity of the ambient air in percentage; t = age of concrete after loading in days; ti = age of
concrete when load is initially applied for accelerated curing or the age minus 6 days for moist curing in days; V/S = volume-to-surface ratio in inches;
wc = density of concrete in kip/ft3.
In general, the test results indicated that the creep behav- In addition, the relationships specified by the AASHTO
ior of HSC is similar to that of normal-strength concrete, LRFD specifications were found to be reasonable to
where the creep rate decreases as time increases. For the predict the creep behavior of HSC except for the time-
same concrete compressive strength, the creep of the development correction factor ktd (Table 4) that produced
1-day heat-cured cylinders was less than that of the 7-day negative values in the first few days after loading if the
moist-cured cylinders. As with normal-strength concrete, concrete compressive strengths were greater than 15 ksi
the creep for HSC is proportional to the applied stress, (103 MPa). For example, if f ci' is 16 ksi (110 MPa), the
provided that the applied stress is less than the proportional value of ktd would be negative for t less than three days.
limit. For t equal to three days, the value of ktd would become
infinity.
The creep coefficient predicted by the AASHTO LRFD
specifications was closer to the measured value for moist- The equation also gives rapidly increasing values of ktd
cured HSC specimens but overestimated the measured val- (more than one can reasonably expect) in the first few days
ue for heat-cured HSC specimens. However, it is noted that for concrete compressive strengths greater than 12 ksi
the predictions by the AASHTO LRFD specifications were (83 MPa). Tadros et al. developed this equation based on
consistently greater than the measured values, in some research data with concrete compressive strengths up to 12
cases by a significant amount. A review of the research ksi, and those data were extrapolated to include strengths
reported by Tadros et al.2 indicates that the predictive equa- up to 15 ksi (103 MPa). In terms of design, although con-
tions proposed by them (Table 4) also overestimated their crete compressive strength of more than 15 ksi is unlikely
own five sets of data for HSC by a substantial amount, to be used as a transfer strength for pretensioned concrete
with standard deviations ranging from 29% to 51%. members, it is possible that the strength could be achieved
PCI Journal | S u m m e r 2 0 1 0 7
1.2 1.2
1 LRFD Specifications 1
10Rack6
Creep coefficient
Creep coefficient
0.6 0.6
0.4 10Rack1
0.4
10Rack3
0.2 0.2
0 0
0 200 400 600 800 0 200 400 600 800
Time after loading, days Time after loading, days
Heat-cured, loaded on 1st day Moist-cured, loaded on 28th day
Set 1 specimens
1.2 1.2
1 LRFD Specifications 1
Creep coefficient
Creep coefficient
0.8 0.8 LRFD Specifications
0.6 0.6
0.4 14Rack1
0.4
0.2 14Rack2
0.2 14Rack5
0 0
0 200 400 600 800 0 200 400 600 800
Time after loading, days Time after loading, days
Set 2 specimens
1.2 1.2
LRFD Specifications
1 1
Creep coefficient
Creep coefficient
0.8 0.8
LRFD Specifications
0.6 0.6
0 0
0 200 400 600 800 0 200 400 600 800
Time after loading, days Time after loading, days
Heat-cured, loaded on 1st day Moist-cured, loaded on 28th day
Set 3 specimens
Figure 2. These graphs compare the average creep coefficients of the specimens to the creep coefficient predictions using the American Association of State Highway and
Transportation Officials’ AASHTO LRFD Bridge Design Specifications.
at the time of loading for cast-in-place concrete columns ciated with the current time-development correction factor
or post-tensioned concrete girders. Accordingly, Eq. (1) is ktd in the AASHTO LRFD specifications.
proposed as a replacement to overcome the anomaly asso-
k td
Time development factor
0.4 0.4
LRFD Specifications LRFD Specifications
Proposed Proposed
0 0
0 100 200 300 400 0 100 200 300 400
Time t, days Time t, days
1.2 1.2
k td
k td
0.8 0.8
f'ci = 12 ksi f'ci = 14 ksi
0.4 0.4
LRFD Specifications LRFD Specifications
Proposed Proposed
0 0
0 100 200 300 400 0 100 200 300 400
Time t, days Time t, days
1.2 1.2
k td
k td
0.8 0.8
f'ci = 16 ksi f'ci = 18 ksi
0.4 0.4
LRFD Specifications LRFD Specifications
Proposed Proposed
0 0
0 100 200 300 400 0 100 200 300 400
Time t, days Time t, days
Figure 3. These graphs compare the American Association of State Highway and Transportation Officials’ AASHTO LRFD Bridge Design Specifications equation with the
proposed equation for time-development correction factors for various concrete compressive strengths. Note: f'ci = specified concrete compressive strength at prestress
transfer. 1 ksi = 6.895 MPa.
t
ktd = (1) f ci' = specified concrete compressive strength at prestress
⎛ 100 − 4 f ' ⎞
12 ⎜ ' ci transfer for prestressed members or 80% of the
⎟ + t
⎝ f ci + 20 ⎠ strength at service for nonprestressed members
where Figure 3 compares the proposed time-development correc-
tion factor and the AASHTO LRFD specifications’ expres-
t = age of concrete after loading in days sion for different concrete compressive strengths up to 18
PCI Journal | S u m m e r 2 0 1 0 9
400 400
LRFD Specifications
10SP3 LRFD Specifications
Shrinkage strain x 10 -6
Shrinkage strain x 10 -6
300 300
100 100
0 0
0 200 400 600 0 200 400 600
Time after curing, days Time after curing, days
Heat-cured, prism Moist-cured, cylinder
Set 1 specimens
400 400
200 200
14SC2
100 14SP3 100
14SP1
0 0
0 200 400 600 0 200 400 600
Time after curing, days Time after curing, days
Heat-cured, prism Moist-cured, cylinder
Set 2 specimens
400 400
200 200
18SP6
0 0
0 200 400 600 0 200 400 600
Time after curing, days Time after curing, days
Figure 4. These graphs compare the adjusted shrinkage strains with the shrinkage strain prediction by the American Association of State Highway and Transportation Of-
ficials’ AASHTO LRFD Bridge Design Specifications.
0.08
0.06
Minimum limit for
0.05 fy = 60 ksi
0.02
Minimum limit for
0.01 fy = 90 ksi
0
6 8 10 12 14 16 18 20
Concrete compressive strength f'c , ksi
Figure 5. This graph shows the reinforcement limits for compression members with only mild steel according to the American Association of State Highway and Transporta-
tion Officials’ AASHTO LRFD Bridge Design Specifications. Note: fy = yield strength of mild steel. 1 ksi = 6.895 MPa.
ksi (124 MPa). For concrete compressive strengths greater shrinkage strains are higher than the measured values at an
than 12 ksi (83 MPa), the proposed time-development early age.
correction factor eliminates the unreasonable predictions
given by the current time-development correction factor, Minimum reinforcement ratio
especially for f ci' greater than 14 ksi (97 MPa). for compression members
PCI Journal | S u m m e r 2 0 1 0 11
However, Fig. 5 shows that the current AASHTO LRFD where
specifications would require a 4.05% minimum reinforce-
ment ratio for 18 ksi (124 MPa) concrete compressive P = applied axial load
strength using Grade 60 (60 ksi or 414 MPa) steel for a
reinforced concrete column section. Such a high level Ec = modulus of elasticity of concrete
of required minimum reinforcement ratio is unusual and
should be examined for HSC. ρl = longitudinal reinforcement ratio
For nonprestressed concrete sections, the required mini- Ag = gross area of concrete
mum longitudinal reinforcement in compression members
was established from early column tests by Richart and Es = modulus of elasticity of steel
Staehle.7–10 When a column is under sustained service
loads, the stress distribution between the steel and the εsh = shrinkage strain of concrete
concrete changes over time due to creep and shrinkage of
the concrete. With creep and shrinkage increasing progres- εcr = creep strain of concrete
sively, concrete relieves itself from its initial share of the
axial load. As a result, longitudinal steel reinforcement For Grade 60 (60 ksi or 414 MPa) steel reinforcement, the
gradually carries a larger portion of the sustained load over yield strain is assumed to be 0.002.
time. Therefore, it is theoretically possible that in columns
with small amounts of longitudinal reinforcement, the The procedure used to calculate the minimum longitu-
reinforcing steel could yield, resulting in creep rupture of dinal reinforcement ratio for compression members was
the column. an iterative procedure that was modeled using Microsoft
Excel. The amount of reinforcement was determined for
Tests by Richart and Staehle showed that the increase of a reinforced concrete column under sustained load, which
stress in the steel reinforcement is inversely proportional to would lead to a total strain of 0.002 after the specified
the percentage of the longitudinal steel. Results from their period of time. The following assumptions and steps were
tests conducted with concrete compressive strengths from used in the analysis:
2 ksi to 8 ksi (14 MPa to 55 MPa) suggested a minimum
reinforcement ratio of 1%. The application of this limit 1. The modulus of elasticity of steel was taken as 30,000
was later extended by the AASHTO LRFD specifications ksi (200,000 MPa) for Grade 60 (60 ksi or 414 MPa)
for concrete compressive strengths up to 10 ksi (69 MPa) steel. For the modulus of elasticity of concrete, the re-
without validation from tests or analysis. lationships proposed by Rizkalla et al.11 as well as the
current AASHTO LRFD specifications (Table 4) were
Three types of strain are developed in the longitudinal used for HSC. Most critical conditions were estab-
reinforcement due to the effect of sustained loading: initial lished using the one proposed by Rizkalla et al. The
elastic strain ε1, strain developed due to shrinkage of con- density of concrete wc used in the analysis was 0.150
crete ε2, and strain developed due to creep of concrete ε3. kip/ft3 (2400 kg/m3) because HSC is more compact
To prevent yielding of the longitudinal reinforcement, the and denser than normal-strength concrete. Equation
summation of the initial elastic strain and the strains due to (3) was proposed by Rizkalla et al. for modulus of
shrinkage and creep should not reach the yield strain of the elasticity Ec.
longitudinal reinforcement. Therefore
0.33
⎧P
⎪ 1 ⎫ ⎧
⎪ ⎪ ( )
1− ρl ε sh Ec ⎫
⎪
( )2.5 ( fc' )
310,000K1 wc (3)
ε1 + ε 2 + ε 3 = ⎨ ⎬+ ⎨ ⎬
⎪⎩ Ag ⎡⎣ Ec 1− ρl + Es ρl ⎤⎦ ⎪⎭ ⎪⎩ ⎡⎣ ρl Es + 1− ρl Ec ⎤⎦ ⎪⎭
( ) ( )
where
⎧ ( )
1− ρl ε cr Ec ⎫
⎪ ⎪
+⎨ ⎬≤
⎡ ρ E + 1− ρl Ec ⎤ ⎪
( ) K1 = correction factor for source of aggregate (taken
⎩⎪ ⎣ l s ⎦ ⎭ Yield strain of
as 1.0)
longitudinal
reinforcement
The analysis was repeated using the current equation
(2) specified by the AASHTO LRFD specifications.
RH= 10%
V/S= 3.0 in LRFD Specifications
Age of Loading= 28 days
0.04 Total Time= 10 years
Es= 30,000 ksi
Ec= 310,000K1(wc)2.5(f'c )0.33
proposed by Rizkalla et al.
0.03 Proposed Relationship
0.02
Prevention of Creep Rupture
(without Creep Stress Relief)
0.01
Prevention of Creep Rupture
ACI 318-08 (with Creep Stress Relief)
0
4 6 8 10 12 14 16 18 20
Concrete compressive strength f'c , ksi
Figure 6. This graph compares the minimum As /Ag ratio for P/f'c Ag = 0.5 with and without considering the stress relief due to creep. Note: Ag = gross area of the section of
a compression member; As = area of mild compression steel; Ec = modulus of elasticity of concrete; Es = modulus of elasticity of steel; f'c = target compressive strength of
concrete, P = applied axial load; RH = relative humidity; V /S = volume-to-surface ratio; wc = density of concrete in kip/ft3.
3. The RH used in the calculation of the creep and tions. By neglecting such effects, the results are more
shrinkage was 10% because a lower RH would pro- conservative, as shown in Fig. 6.
duce more-critical results.
9. First the initial value for the longitudinal reinforce-
4. The volume-to-surface ratio used in the calculation of ment ratio ρl for a reinforced concrete column was
creep and shrinkage was 3 in. (75 mm). The volume- assumed. Then the initial elastic strain and strains due
to-surface ratio for a circular column with a 12 in. to creep and shrinkage were calculated based on the
(300 mm) diameter is 3 in. (75 mm). It is the same for previous discussions in this section. The sum of all
a 12 in. × 12 in. (300 mm × 300 mm) square column. three strain values, the total strain εtotal, was calculated
and compared with the yield strain of steel reinforce-
5. The time considered in the calculation of the creep and ment. By changing the initial value of the longitudinal
shrinkage was 10 yr. reinforcement ratio, the reinforcement ratio for which
the total strain was equal to the yield strain of steel
6. The age of loading in the calculation of the creep coef- was determined. This reinforcement ratio would be the
ficient was 28 days. minimum amount of longitudinal reinforcement ratio
for compression members to prevent creep rupture.
7. The sustained load level on the reinforced concrete
column considered in this investigation was 50% (P/ 10. Step 9 was performed for all of the concrete compres-
f c' Ag = 0.5). The unfactored permanent load on col- sive strengths in the range of 6 ksi to 18 ksi (41 MPa
'
umns does not exceed 0.5 f c Ag, which is typically the and 124 MPa).
case encountered in design.
The most-critical conditions were evaluated in the calcu-
8. The effects associated with stress relief for both creep lation of the minimum longitudinal reinforcement ratio
and shrinkage due to creep of concrete in tension are for compression members. Based on the analysis using
neglected in the formulation of the equilibrium condi- the proposed equation for Ec and the current relationship
PCI Journal | S u m m e r 2 0 1 0 13
Table 5. Comparison of the minimum As /Ag ratio for P/f 'c Ag = 0.5
Minimum As /Ag
f 'c , ksi
AASHTO LRFD specifications ACI 318-08 Proposed Analytical results
Note: Ag = gross area of the section; As = area of mild steel; f c' = compressive strength of concrete; P = applied axial load. 1 ksi = 6.895 MPa.
specified by the AASHTO LRFD specifications, Eq. (4) is Table 5 and Fig. 6 show the minimum longitudinal
'
proposed as a new relationship for the minimum reinforce- reinforcement ratio for the stress level P/ f c Ag of 0.5 as re-
ment ratio for compression members. quired by the current AASHTO LRFD specifications, ACI
318-08,6 and the proposed Eq. (4) based on the discussed
As Aps f pu f' procedure considering the effects of creep and shrinkage.
+ ≥ 0.135 c (but not greater than 0.0225) (4) The figure clearly indicates that for concrete compres-
Ag Ag f y fy
sive strength greater than 10 ksi (69 MPa), the required
minimum longitudinal reinforcement ratio by the proposed
where equation is much less than that by the current AASHTO
LRFD specifications but still provides a substantial margin
As = area of mild-tension steel against what is needed to prevent creep rupture.
Aps = area of prestressing steel Table 6 tabulates the calculated values for minimum rein-
forcement ratio for compression members to prevent creep
'
fpu = specified tensile strength of prestressing steel rupture for P/ f c Ag of 0.5. The summation of the initial elas-
tic, shrinkage, and creep strains is equal to the yield strain of
fy = yield strength of mild-tension steel 0.002 for Grade 60 (60 ksi or 414 MPa) steel reinforcement.
The creep and shrinkage strains of concrete decrease as con-
For concrete compressive strengths up to 10 ksi (69 MPa), crete compressive strength increases. However, the initial
the proposed relationship for the minimum longitudinal elastic strain increases as concrete compressive strength
reinforcement ratio requires the same amount as that of the increases because the same stress level was applied on each
AASHTO LRFD specifications. For concrete compres- column with different concrete compressive strengths.
sive strengths greater than 10 ksi (69 MPa), the proposed
equation requires the same amount (0.0225) for concrete When columns with concrete compressive strengths of
compressive strengths up to 18 ksi (124 MPa). Further- 6 ksi and 18 ksi (41 MPa and 124 MPa) are compared
'
more, the proposed minimum reinforcement limitation is under P/ f c Ag of 0.5, the load applied on the column with a
similar in format to the maximum reinforcement limitation concrete compressive strength of 18 ksi (124 MPa) is three
specified by the AASHTO LRFD specifications. times that applied on the column with a concrete compres-
sive strength of 6 ksi (41 MPa). However, the modulus
f 'c , ksi ρl , % Ec , ksi Initial elastic strain ε1 Shrinkage strain ε2 Creep strain ε3
Note: Ag = gross area of the section; Ec = elastic modulus of concrete; f c' = compressive strength of concrete; P = applied axial load; ρl = longitudinal
reinforcement ratio. 1 ksi = 6.895 MPa.
of elasticity of the column with a concrete compressive • AASHTO LRFD specifications overestimate creep
strength of 18 ksi (124 MPa) is only 1.44 times that of the coefficients for heat-cured HSC specimens, but the
column with a concrete compressive strength of 6 ksi (41 AASHTO LRFD specifications produced closer pre-
MPa). Therefore, the minimum reinforcement ratio for dictions for moist-cured HSC specimens.
compression members cannot be reduced for HSC com-
pared with normal-strength concrete, though the creep and • The relationships specified by the AASHTO LRFD
shrinkage are less for HSC. specifications are reasonable for predicting creep of
HSC, except for the time-development correction fac-
Conclusion tor ktd , which produces negative values in the first few
days after loading if the concrete compressive strength
A total of 42 cylindrical specimens and 18 prismatic is greater than 15 ksi (103 MPa). Accordingly, a new
specimens were tested for up to two years to evaluate time-development correction factor (Eq. [1]) was de-
the creep and shrinkage behavior of HSC. The variables veloped to overcome the anomaly associated with the
considered in this investigation were concrete compres- current time-development correction factor.
sive strengths from 10 ksi to 18 ksi (69 MPa to 124 MPa),
specimen shape (cylinder or prism), curing type (moist or • Heat-cured specimens have less shrinkage compared
heat curing), age of concrete at loading (1 day, 7 days, 14 with moist-cured specimens.
' '
days, or 28 days), and loading stress level (0.2 f c or 0.4 f c
). The creep coefficient and shrinkage strain were obtained • The difference in the shrinkage for HSC specimens
for the range of concrete compressive strengths, evaluated, with concrete compressive strengths ranging from 10
and compared with the predictions by the AASHTO LRFD ksi to 18 ksi (69 MPa and 124 MPa) is small.
specifications. Several conclusions were made:
• AASHTO LRFD specifications predict the shrinkage
• The creep behavior of HSC is similar to that of of HSC specimens well.
normal-strength concrete, where creep rate decreases
as time increases. • For HSC, the current AASHTO LRFD specifications
would require unusually high amounts of minimum
• For the same concrete compressive strength, the creep longitudinal reinforcement for nonprestressed, non-
of the 1-day heat-cured cylinders is less than that of composite concrete compression members. Based on
the 7-day moist-cured cylinders. the analysis presented in this paper, a new relationship
PCI Journal | S u m m e r 2 0 1 0 15
(Eq. [4]) was proposed for the minimum reinforce- Illinois. Journal of the American Concrete Institute,
ment ratio for compression members. V. 27: pp. 761–790.
5. Mertol, H. C. 2006. Characteristics of High Strength fpu = specified tensile strength of prestressing steel
Concrete for Combined Flexure and Axial Compres-
sion Members. PhD thesis. Department of Civil, fy = yield strength of mild steel
Construction and Environmental Engineering, North
Carolina State University, Raleigh, NC. kf = concrete strength factor
6. American Concrete Institute (ACI) 318. 2008. Build- khc = humidity factor for creep coefficient
ing Code Requirements for Structural Concrete (ACI
318-08) and Commentary (ACI 318R-08). Farmington khs = humidity factor for shrinkage strain
Hills, MI: ACI.
kla = loading-age factor
7. Richart, F. E., and G. C. Staehle. 1931. Progress Report
on Column Tests at the University of Illinois. Journal ks = size factor
of the American Concrete Institute, V. 27: pp. 731–760.
ktd = time-development correction factor
8. Richart, F. E., and G. C. Staehle. 1931. Second
Progress Report on Column Tests at the University of
RH = relative humidity
wc = density of concrete
ψ = creep coefficient
PCI Journal | S u m m e r 2 0 1 0 17
About the authors size, curing type, age of concrete at loading, and load-
ing stress level.
Halit Cenan Mertol, PhD, is an
assistant professor for the Research findings indicate that the current American
Department of Civil Engineering Association of State Highway and Transportation
at Atilim University in Ankara, Officials’ AASHTO LRFD Bridge Design Specifica-
Turkey. tions could be used to estimate the creep coefficient
and shrinkage strain of HSC up to 15 ksi (103 MPa).
However, the current AASHTO LRFD specifications
Sami Rizkalla, PhD, P.Eng., do not provide appropriate predictions for concrete
FPCI, is a Distinguished Profes- compressive strength greater than 15 ksi (103 MPa). A
sor of Civil, Construction, and revised time-development correction factor is pro-
Environmental Engineering and posed to obtain better predictions for HSC up to 18 ksi
director of the Constructed (124 MPa).
Facilities Laboratory at North
Carolina State University in For HSC compression members, the current AASHTO
Raleigh, N.C. LRFD specifications require an excessive amount
of minimum longitudinal reinforcement to account
Paul Zia, PhD, P.E., FPCI, is a for the long-term effects due to shrinkage and creep.
Distinguished University Profes- Based on an analysis, a new relationship is proposed
sor Emeritus at North Carolina for the required minimum reinforcement ratio.
State University in Raleigh, N.C.
Keywords
This paper summarizes the findings of an extensive Please address any reader comments to PCI Journal
research program that examined the shrinkage and editor-in-chief Emily Lorenz at elorenz@pci.org
creep behavior of high-strength concrete (HSC) up to or Precast/Prestressed Concrete Institute, c/o PCI
a strength of 18 ksi (124 MPa). Creep and shrinkage Journal, 200 W. Adams St., Suite 2100, Chicago, IL
strains of 60 specimens were monitored for up to two 60606. J
years. The variables considered in this investigation
were the concrete compressive strength, specimen